Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Https://Eproc.Cgstate.Gov.In-1 RADIAL CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 1 Guiding Catheter 1 2 Diagnostic Catheter 2 3 Drug eluting stent (Everolimus) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 1 7 Hydrophillic wire J tip* 0.32-0.38 2 8 Radial arterial introducer sheath set 6F 2 9 Three port manifold 2 10 Pressure line 150cm 4 11 Y connector 1 12 Long tube to connect Y Connector to manifold 1 13 Inflation device 1 14 TR Band 1 15 Syringe – 20 ml luer lock 1 16 Syringe – 10 ml luer lock 3 17 ACT Kit 2 18 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 2 FEMORAL 1 Guiding Catheter 1 13 CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 2 Diagnostic Catheter 2 3 Drug eluting stent (Everolimus) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 1 7 Guide wire J tip* 0.32 - 0.38 2 8 Femoral arterial introducer sheath set 7F 1 9 Radial arterial introducer sheath set 6F 1 10 Three port manifold 2 11 Pressure line 150cm 4 12 Y connector 1 13 Long tube to connect Y Connector to manifold 1 14 Inflation device 1 15 Hemostatic Device 1 16 Syringe – 20 ml luer lock 1 17 ACT Kit 2 18 Syringe – 10 ml luer lock 3 19 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 3 CORONARY ANGIOGRAPHY (FEMORAL ROUTE) 1 Diagnostic Catheter / JL & JR 2 2 Hydrophillic wire J tip* 0.32 -0.38 2 3 Radial arterial introducer sheath set 6F 2 4 Three port manifold 2 5 Pressure line 150cm 4 6 Y connector 1 7 Long tube to connect Y Connector to manifold 1 8 Hemostatic Device 1 9 Syringe – 20 ml luer lock 1 10 Syringe – 10 ml luer lock 3 11 STERILE DRAPE FOR RADIATION PROTECTION 4 CORONARY ANGIOGRAPHY (RADIAL ROUTE) 1 Diagnostic Catheter / JL & JR TIGER 3 2 Hydrophillic wire 0.32 - 0.38 2 3 Radial arterial introducer sheath set 6F 1 4 Three port manifold 2 5 Pressure line 150cm 4 6 Y connector 1 7 Long tube to connect Y Connector to manifold 1 9 TR Band 1 10 Syringe – 20 ml luer lock 1 11 Syringe – 10 ml luer lock 3 12 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 5 RIGHT HEART CATHETERISATION + 1 Guide wire J tip* 0.32 - 0.38 1 2 Femoral arterial introducer sheath set* 2 3 Two port manifold 1 4 Control syringe 12 cc 2 5 Catheter NIH*/ MULTIURPOSE CATHETER / SWAN GANZ CATHETER 1 6 Catheter GL/Angio Burman 1 7 Power Injector Syringe 1 8 I -STAT EG7+ KIT 12 9 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 6 LEFT HEART CATHETERISATION 1 Guide wire J tip* 0.32 - 0.38 1 2 Femoral arterial introducer sheath set* 2 3 Two port manifold 1 4 Pressure line 2 6 Catheter Pigtail* 1 15 7 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 7 ASD DEVICE CLOSURE 1 Pigtail Catheter * 1 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32 -0.38 X 260 1 4 Straight Tip Hydrophillic wire 0.32 X 260 1 5 Power Injector Syringe 1 6 Femoral arterial introducer sheath set* 2 7 Two port manifold 1 8 Pressure line 1 9 Closure Device set* (Closure Device + Delivery Systam) 1 10 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 8 VSD DEVICE CLOSURE 1 Pigtail Catheter * 1 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32 -0.38 X 260 1 4 Angled Tip Hydrophillic wire 0.32 X 260 1 5 Power Injector Syringe 1 6 Femoral arterial introducer sheath set* 2 7 Two port manifold 1 8 Pressure line 1 9 Closure Device set* (Closure Device + Delivery Systam) 1 10 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 9 PDA DEVICE CLOSURE 1 Pigtail Catheter * 1 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J 1 16 tip* 0.32 -0.38 X 260 4 Angled Tip Hydrophillic wire 0.32 X 260 1 5 Power Injector Syringe 1 6 Femoral arterial introducer sheath set* 2 7 Two port manifold 1 8 Pressure line 1 9 Closure Device set* (Closure Device + Delivery Systam) 1 10 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 10 RENAL ANGIOPLASTY 1 Guide wire J tip* 0.32 - 0.38 1 2 Femoral arterial introducer sheath set* 1 3 Two port manifold 1 4 Pressure line 1 5 Renal Angiography Catheter * 1 6 Renal Guiding Catheter * 1 7 Renal Angioplasty Guide wire* 1 8 Renal Angioplasty Balloon * 1 9 Renal Stent (DES) * 1 10 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 11 LAA DEVICE CLOSURE 1 Pigtail Catheter * 1 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32 -0.38 X 260 1 4 Angled Tip Hydrophillic wire 0.32 X 260 1 5 Power Injector Syringe 1 6 Femoral arterial introducer sheath set* 2 7 Two port manifold 1 8 Pressure line 1 17 9 Closure Device set* (Closure Device + Delivery Systam) 1 10 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 12 Pericardiocentesis 1 Femoral arterial introducer sheath set* + PUNCTURE NEEDLE 1 2 Pigtail Catheter * 1 13 BALLOON ATRIAL SEPTOSTOMY 1 Pigtail Catheter * 1 2 Guide wire J tip* 0.32- 0.38 X 260 1 3 Femoral arterial introducer sheath set* 1 4 Two port manifold 1 5 Pressure line 1 6 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 14 CORONARY ANGIOPLASTY with the Help of Drug Eluting Balloon Without Stent 1 Guiding Catheter 1 2 Diagnostic Catheter 2 3 Drug eluting Balloon 1 4 PTCA Wire 1 5 Hydrophillic wire J tip* 0.32-0.38 2 6 Radial arterial introducer sheath set 6F 2 7 Three port manifold 2 8 Pressure line 150cm 4 9 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 15 INTRODUCER SHEATH 8,9,10,F FEMORAL Atraumatic tapered tip, enhanced pushability and flexibility,Hemostatic valve maintains uncompromised haemostasis to avoid bleeding and air aspiration, enlarged inner diameter for ultra smooth transition between dilator and sheath, lubricant coating, Metallic puncture needle with mini J tipped PTFE guide wire. Length 11cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided 16 INTRODUCER SHEATH FEMORAL Atraumatic tapered tip, enhanced pushability and flexibility,Hemostatic valve maintains uncompromised haemostasis to avoid bleeding and air aspiration, enlarged inner diameter for ultra smooth transition between dilator and sheath, lubricant coating, Metallic puncture needle with mini J tipped PTFE guide wire. Length 23cm. All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 17 CONTROL SYRINGE Control syringes latex free specially designed for ease of use. The plunger tip and barrel are designed for consistent movement and smooth rotator action. The enhanced graduation markings increase legibility. The clear polycarbonate design allows for enhanced visual inspection and the enlarged reservoir stop is specially designed to decrease the possibility of air infusion. Create smooth feel during injection, Clear Barrel : Provides clarity and smooth as glass feel, Solid Plunger Body : Maintains stability and durability under pressure, Rotating luers. Intended to minimize the potential of air bubbles introduced into the catheter. 10 ml Dose control syringe, 12 ml Dose control syringe, 20 ml Dose control syringe. 18 PRESSURE MONITERING LINE 150-200CM ClearTubo Pressure Monitoring Line is made up of High quality medical grade pvc tubing, it helps to reduces the risk of kinking. It comes with a choice of either male to male or male to female luer locks . The pressure range of this line is more than or equal to 1000 psi. The Length ranges from 150 cm to 300 cm. Small bore pressure line helps to get accurate pressure transmission to the ClearCaths tip & ClearGuides tip, Kink resistant medical grade PVC tube, does not bulge even at high pressure, Male and female luer locks help to ensures secure connection, E.T.O. Sterile, High degree of safety and low toxicity, Multi end adapter option, compatible with different specifications. 19 Y CONNECTOR KIT Connector are easy, fast and accurate single handed intra vascular device for insertion of PTCA Guidewire. Perfect insertion device respecting the integrity of the coated surface with combination of a hemostatic valve and an integrated valve opener. It is a clean and safe product with a minimized backflow thus limiting blood loss during the procedure. Push Click Type Kit.. 20 Y CONNECTOR KIT Connector are easy, fast and accurate single handed intra vascular device for insertion of PTCA Guidewire. Perfect insertion device respecting the integrity of the coated surface with combination of a hemostatic valve and an integrated valve opener. It is a clean and safe product with a minimized backflow thus limiting blood loss during the procedure. Push Pull Type Kit.. 21 Y CONNECTOR KIT Connector are easy, fast and accurate single handed intra vascular device for insertion of PTCA Guidewire. Perfect insertion device respecting the integrity of the coated surface with combination of a hemostatic valve and an integrated valve opener. It is a clean and safe product with a minimized backflow thus limiting blood loss during the procedure. Screw Type Kit.. 22 Infusion Catheter 4F & 5F Valved Infusion Catheter with Multiple ports,135cm Catheter length, Available in infusion10cm and 20cm length. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 23 INFLATION DEVICE Maximum Pressure of 30 atm, 20ML clear syringe barrel with smooth moving plunger, self locking mechanism for easy locking as well as gradual and rapid pressure release,Ergonomic handle and Precision manometer, 24 RADIAL ARTERY COMPRESSION BAND RA BAND ClearBand R.A. Band is used to stop bleeding after Angiography procedure, PTCA procedure or PCI procedures. Adjustable soft silicon compression parts make the patient feel easy after procedure. Standard/Screw Type 20 ml, High Quality, Transparent material - So blood leakage can be visualized, Method of locking system (Velcro or other), Method of Puncture compression, Selective compression of Radial Artery which allows blood return and maintain the patency of the Artery, Easy to identify malfunction, Length of the band should properly fit with maximum patient comfort. 25 VASCULAR ACCESS CLOSURE DEVICE Vascular Closure Device For Femoral - Plug based, All Sizes. 26 Guiding Sheath Guiding sheath with soft tip and a hydrophilic coating, which enhance trackability while .018” and .038” compatible dilators provide choice in platform. The straight configuration of the sheath provides a platform able to meet your procedural needs. The Guiding sheath with 180˚ curve that anchors across the bifurcation to stabilize your contralateral access. Various designs available and All Sizes.. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 27 Y-connector designed for guiding, positioning, and locking guidewires or catheters into place. 2-way Adjustable Valve. 28 Y-connector designed for guiding, positioning, and locking guidewires or catheters into place. 3-way Adjustable Valve. 29 LONG SHEATH All Shape and All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 30 MULLINS SHEATH Various Sizes The sterile Mullins sheath/dilator set with recommended 0.032 wire.. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 31 MULLINS SHEATH Various Sizes The sterile Mullins sheath/dilator set with recommended 0.032 wire with Stopcock and Hemostasis Valve. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 32 PRESSURE INJECTOR SYRINGE Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. 33 INTRODUCER NEEDLE 16G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 16 G x near by 4, 7, 9 cm 34 NTRODUCER NEEDLE 17G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 17 G x near by 4, 7, 9 cm 35 INTRODUCER NEEDLE 19G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 19 G x near by 4, 7, 9 cm INTRODUCER NEEDLE 20G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 20 G x near by 4, 7, 9 cm 37 NTRODUCER NEEDLE 21G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 21 G x near by 4, 7, 9 cm 38 INTRODUCER NEEDLE 22G Clear Needle with smoother surface, which provide less friction. needle has enhanced sharpened tip with polymer coated cannula which provide better and smoother penetration during seldinger technique . Flawless metal surface of cannula made of Stainless steel. Introducer needle with thin outer wall which help get better Inner diameter of cannula to provide more space to introduce Clear Gwire. Needle in square hub , round Hub and Y shape. (This helps to provide the dual port for insertion from single penetration. Sizes: 22 G x near by 4, 7, 9 cm 39 Micropuncture Needle Set Needle, wire guide(With a Nitinol Wire Guide that has a Palladium Tip) and coaxial catheter pair. Available in Needle lenth 21G and & 7cm, Outer catheter 4F/5F 40 Micropuncture Needle Set Needle, wire guide(With a Nitinol Wire Guide that has a Palladium Tip) and coaxial catheter pair. Available in Needle lenth 21G and & 4cm, Outer catheter 4F/5F 41 Steerable Introducer Sheath Sheath with the Maximum 160 deg. Tip Deflation Technology. To have the easy and quick access to targets with the flexible tip. Available with rotary handle facility. 42 Hemo Intro 8F 60cm Introducer Sheath with Hemostasis Valve and Sideport, Dilator, and 145 cm Guidewire with 3 mm “J” 22 43 2CC Luer lock syringes for microcatheter tip injection 44 OKAY II Y Connector 45 Radial sheath with a thin wall structure where the outside diameter is reduced by one French size while the inner diameter equivalent is maintained; 5,6,7 Fr sheaths 46 Balkins Guiding sheath 47 CORONARY DIGNOSTIC CATHETER: JL 5 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 48 CORONARY DIGNOSTIC CATHETER: JL 6 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 49 CORONARY DIGNOSTIC CATHETER: JR 4.5 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 50 CORONARY DIGNOSTIC CATHETER: JR 5 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 51 CORONARY DIGNOSTIC CATHETER: JR 6 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 52 CORONARY DIGNOSTIC CATHETER: AL 0.75 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 53 CORONARY DIGNOSTIC CATHETER: AL 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 23 54 CORONARY DIGNOSTIC CATHETER: AL 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 55 CORONARY DIGNOSTIC CATHETER: AL 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 56 CORONARY DIGNOSTIC CATHETER: AR 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 57 CORONARY DIGNOSTIC CATHETER: AR 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 58 CORONARY DIGNOSTIC CATHETER: AR 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 59 CORONARY DIGNOSTIC CATHETER: Multipurpose A Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 60 CORONARY DIGNOSTIC CATHETER: Multipurpose B Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 61 CORONARY DIGNOSTIC CATHETER: IMA Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 24 62 CORONARY DIGNOSTIC CATHETER: NIH Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 63 CORONARY DIGNOSTIC CATHETER: Sones Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 64 CORONARY DIGNOSTIC CATHETER: Sones with side holes Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 65 CORONARY DIGNOSTIC CATHETER: Cobra 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr.Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 66 CORONARY DIGNOSTIC CATHETER: Cobra 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr.Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 67 CORONARY DIGNOSTIC CATHETER: Cobra 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 68 CORONARY DIGNOSTIC CATHETER: Simmons 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 69 CORONARY DIGNOSTIC CATHETER: Simmons 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 25 70 CORONARY DIGNOSTIC CATHETER: Simmons 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 71 CORONARY DIGNOSTIC CATHETER: Headhunter 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr . Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 72 CORONARY DIGNOSTIC CATHETER: Headhunter 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 73 CORONARY DIGNOSTIC CATHETER: Headhunter 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 74 CORONARY DIGNOSTIC CATHETER: Renal Double Curve Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 75 CORONARY DIGNOSTIC CATHETER: Vitek Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 76 CORONARY DIGNOSTIC CATHETER: Hockey Stick Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 77 CORONARY DIGNOSTIC CATHETER: Sidewinder Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 26 78 CORONARY DIGNOSTIC CATHETER: Cournand Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 79 CORONARY DIGNOSTIC CATHETER: Vertebral Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 80 CORONARY DIGNOSTIC CATHETER: RCB Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 81 CORONARY DIGNOSTIC CATHETER: LCB Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 82 CORONARY DIGNOSTIC CATHETER: SRC Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 83 CORONARY DIGNOSTIC CATHETER: Renal Diagnostic Catheter Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 84 TIGER SHAPE CATHETER (Radial) The high flow of the catheter allows for more contrast into the vessel that results in a clear, bright angiogram. Your diagnosis and treatment planning is enhanced. Quick, Safe Vessel Engagement: polymer material and full length double braiding provides excellent push ability and efficient torque transmission for outstanding handling. Soft atraumatic tip designed to reduce potential for vessel trauma. Wide variety of curve styles for all possible anatomies. Used in Angiography for Cardiac patients and are designed to deliver radiopaque cont ast medium to selected sites in the vascular system. Shape Retention property. Available in 5F and 6F. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 85 Guiding Catheter Specifications: JL 3 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 86 Guiding Catheter Specifications: JL 3 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 87 Guiding Catheter Specifications:JL 3.5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 88 Guiding Catheter Specifications:JL 3.5 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 28 89 Guiding Catheter Specifications:JL 4 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 90 Guiding Catheter Specifications:JL 4 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 91 Guiding Catheter Specifications: JL 4.5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 92 Guiding Catheter Specifications: JL 4.5 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 93 Guiding Catheter Specifications: JL 5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 29 94 Guiding Catheter Specifications: JL 5 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 95 Guiding Catheter Specifications: JL 6 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 96 Guiding Catheter Specifications: JL 6 with Sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 97 Guiding Catheter Specifications: JR 3 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 98 Guiding Catheter Specifications: JR 3 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 30 99 Guiding Catheter Specifications: JR 3.5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 100 Guiding Catheter Specifications: JR 3.5 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 101 Guiding Catheter Specifications: JR 4 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 102 Guiding Catheter Specifications: JR 4 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 103 Guiding Catheter Specifications: JR 4.5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 31 104 Guiding Catheter Specifications: JR 4.5 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 105 Guiding Catheter Specifications: JR 5 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 106 Guiding Catheter Specifications: JR 5 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 107 Guiding Catheter Specifications: JR 6 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 108 Guiding Catheter Specifications: JR 6 with sidehole Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 32 109 Guiding Catheter Specifications: AL 0.75 (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 110 Guiding Catheter Specifications: AL 0.75 with sidehole (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 111 Guiding Catheter Specifications: AL 1 (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 112 Guiding Catheter Specifications: AL 1 with sidehole (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 113 Guiding Catheter Specifications: AL 2 (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and 33 non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 114 Guiding Catheter Specifications: AL 2 with sidehole (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 115 Guiding Catheter Specifications: AR 1 (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 116 Guiding Catheter Specifications: AR 1 with sidehole (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 117 Guiding Catheter Specifications: AR 2 (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided Guiding Catheter Specifications: AR 2 with sidehole (Short tip and Standard tip) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 119 Guiding Catheter Specifications: Extra Backup 3 for Right & Left Coronary Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 120 Guiding Catheter Specifications: Extra Backup 3.5 for Right & Left Coronary Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 121 Guiding Catheter Specifications: Extra Backup 4 for Right & Left Coronary Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 122 Guiding Catheter Specifications: Extra Backup 5 for Right & Left Coronary Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and 35 non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 123 Guiding Catheter Specifications: Extra Backup 3 for Right & Left Coronary (With Sidehole) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 124 Extra Backup 3.5 for Right & Left Coronary (With Sidehole) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 125 Guiding Catheter Specifications: Extra Backup 4 for Right & Left Coronary (With Sidehole) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 126 Guiding Catheter Specifications: Extra Backup 5 for Right & Left Coronary (With Sidehole) Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 36 127 Guiding Catheter Specifications: Any Other Type Of Extra Backup Coronary Guide Catheter/ Specialized Shape Guiding Catheter Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 128 Guiding Catheter Specifications: IMA Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 129 Guiding Catheter Specifications: Hockey Stick Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 130 Guiding Catheter Specifications: Multipurpose 1 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 131 Guiding Catheter Specifications: Multipurpose 2 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic 37 procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 132 Guiding Catheter Specifications: Right Coronary Bypass Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 133 Guiding Catheter Specifications: Renal Guide Catheter Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 134 Guiding Catheter Specifications: Head Hunter Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 135 Guiding Catheter Specifications: Left Coronary Bypass Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 38 136 Guiding Catheter Specifications: Any Other Type Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 137 Femoral Guiding Catheter Specifications: Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: ≥ 120 cm, Sizes 4/5/6/7/8 Fr for all available curves. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 138 Femoral Guiding Catheter Specifications: Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: < 100 cm, Sizes 4/5/6/7/8 Fr for all available curves. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 139 Dedicated Radial Guiding Catheter Specifications: Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Hydrophilic coating, Sizes 4/5/6/7/8 Fr for all available curves, Single Radial Guiding catheter for left and right system. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 39 140 Guide catheter for Carotid Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 141 Pigtail Angled Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 142 Pigtail Straight Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 143 Pigtail Curved Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 144 Pigtail marker Catheter Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 145 NIH CATHETER Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 146 SWAN GANZ CATHETER Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 40 147 BERMAN CATHETER For balloon occlusion pulmonary angiography with high flow of dye injection (12-24cc/sec according to size) through side holes to optimize dye distribution and minimize the risk of arrhythmias, and myocardial staining by directing dye away from the myocardial wall. 5F Compatible 80 cm length, 6F compatible with 90 cm lenth and 7F compatible with 110 cm length. . Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 148 Guide catheter for CTO cases with guidewire port, torque device lock, ratcheting torque device, working length 135cm. 149 self orienting, flat balloon that automatically positions one exit port towards true lumen with Hydrophillic coating on the balloon shaft. Guidewire shaft diameter o.o14, angled tip. Cathter with guidewire port and balloon inflation port, working length 135 cm. 150 MICRO CATHETER Micro channel dilator tapered soft tip of 1.3 Fr with tungsten Braiding and hydrophilic polymer shaft with OD of 2.6Fr; Length 100-150 cm. 151 MICRO CATHETER Wire braded catheter works with rotation movements for CTO penetration catheter, length 135cms. 152 MICRO CATHETER Dedicated dual lumen micro catheter for side branch access. 153 Micro Catheter for Coronary Braided, Hydrophilic coated, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 1.8 Fr. 154 Micro Catheter for Coronary Braided, Hydrophilic coated, tapered tip, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 1.9 Fr. 155 Rotational Burrowing Microcatheter Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.1 Fr. 156 Rotational Burrowing Microcatheter Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.6 Fr. 157 Dual Lumen Micro Catheter Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.9 Fr. 158 PROGREAT MICROCATHETER 159 Guide Extension Catheter Hydrophillic Coating, Soft Polymer Tip, With Radiopaque marker. All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 41 160 GUIDE EXTENSION CATHETER Available in 6Fr and 7Fr, Catheter Length 150cm, Platinum iridium marker band, Positioning markers at 90 cm and 100 cm from distal tip, TruFlex soft polymer tip (2mm) can responsively bend and deflect, should smoothly channel interventional device, Entry port and unique 3-mm spade-shaped marker band, Tapered distal pushwire section transitions from solid, round proximal pushwire for flexibility, 4-cm polymer on-ramp to channel interventional devices, Hydrophilic coating, outer layer of distal 21 cm, 1-mm long distal marker 2 mm from end of tip, 2.5-cm proximal jacket made of rigid polymer selected to maintain luminal integrity, Distal extension length 25 cm. 161 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.021, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 162 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.021, Length: 120- 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 163 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 164 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 165 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.025, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 166 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.025, Length: 120- 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 42 167 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 168 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 169 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.032, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 170 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.032, Length: 120- 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 171 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 172 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 173 Angiographic Guide Wire ngiographic Guide Wire, PTFE coated, Straight tip, 0.035, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 174 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.035, Length: 120- 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 43 175 Angiographic Guide Wire Wire, PTFE coated, Straight tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 176 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 177 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.038, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 178 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.038, Length: 120- 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 179 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, Straight tip, 0.038, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 180 Angiographic Guide Wire Angiographic Guide Wire, PTFE coated, J tip, 0.038, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 181 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.021, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 182 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.021, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, 44 Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 183 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 184 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 185 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.025, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 186 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.025, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 187 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 45 188 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 189 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.032, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 190 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.032, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 191 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 192 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 193 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.035, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 46 194 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.035, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 195 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 196 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 197 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.038, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 198 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.038, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 199 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, Straight tip, 0.038, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 47 200 Hydrophillic Guide Wire Polyurethane outer layer, super elastic nickel-titanium alloy core, Hydrophilic coating that provides unmatched lubricity and superior lubricity retention, soft tip, J tip, 0.038, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 201 Transradial Hydrophillic Guide Wire Transradial Angiographic Guide Wire, Hydrophilic coated, 1.5 mm J tip, Size 0.035 x 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 202 Transradial Hydrophillic Guide Wire Transradial Angiographic Guide Wire, Hydrophilic coated, 1.5 mm J tip, Size 0.035 x 180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 203 AMPLATZER EXTRA STIFF WIRE Stainless steel wire with a flat-wire coil and PTFE coating, tip radioopacity 1 cm, various diameter 0.035 to 0.038mm, various length 150cm,180cm and 260cm, various tip flexibility floppy, intermediate and standard; both straight and j tip. 5 years shelf life. 10 years of experience of use in hospitals.. 204 PTCA wire 0.014 0.014 Stainless Steel core wire available in length of 180cm and 300 cm with St tip, Available with Hydrophillic coating, Distal coil segment for tactile feeling, Good torque transmission & Crossability Available in tip load of 1gm, Distal 3mm radiopaque. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 205 PTCA wire 0.014 0.014 Stainless Steel core wire available in length of 180cm and 300 cm with St tip, Available with Hydro Track coating, Distal coil segment for tactile feeling, Good torque transmission & Crossability, Available in tip load of 3,6,9,12,15g, 3 & 6g tip load wire available in straight tip(0.014”), 9,12 & 15g tip load wire available in tapered tip(0.009”),Distal 1mm hydrophobic in nature, Distal 3mm radiopaque. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 48 206 PTCA wire 0.014 0.014 coronary guidewire, 0.7 g Tip Stiffness, Elastinite Nitinol core, 4.5 cm radiopacity,Hydrophillic Coating, Soft shaping ribbon tip. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 207 PTCA wire 0.014 0.014 coronary guidewire, 0.7g Tip Stiffness, stainless steel core, 3 cm radiopacity, hydrophobic Coating, Core-to-tip design, Intermediate polymer sleeve, Jointless spring coil for excellent device interaction Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 208 PTCA wire 0.014 0.014 coronary guidewire, 0.8g Tip Stiffness, steel core, 4 cm radiopacity, hydrophobic Coating, Core-to-tip design, Extremely supportive for bulky device delivery. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 209 PTCA wire 0.014 0.014 coronary guidewire, 1.0g Tip Stiffness, stainless steel core, 3 cm radiopacity, hydrophobic Coating, Core-to-tip design Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 210 PTCA wire 0.014 0.014 coronary guidewire, Elastinite Nitinol core , Double coil tip, Tip style- shaping ribbon, Light support, Straight or J tipped, Hydrophillic/ Silicon coating, 3cm distal radioopaque marker. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 211 PTCA wire 0.014 0.014 coronary guidewire,Elastinite Nitinol core , Double coil tip, Tip style-shaping ribbon, medium support, Straight or J tipped, Hydrophillic/ Silicon coating, 3cm distal radioopaque marker. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 212 PTCA wire 0.014 0.014 coronary guidewire, stainless steel core, 1:1Torque performance and one-gram tip weight, Tip style: Core-to-tip, Hydrophillic coating, 3cm distal radioopaque marker, Proximal marker at 90cm & 100cm from distal tip Clinically used for 49 minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 213 PTCA wire 0.014 0.014 coronary guidewire, Elastinite Nitinol core material, Bare coil covering, Tip style: Core-to-tip, Hydrophillic coating, Tip Load 0.8 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 214 PTCA wire 0.014 0.014 coronary guidewire, Elastinite Nitinol core material, Bare coil covering, Tip style: Core-to-tip, Hydrophillic coating, Tip Load 0.6 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 215 PTCA wire 0.014 0.014 coronary guidewire, Elastinite Nitinol core material, Bare coil covering, Tip style: shaping ribbon, Hydrophillic/Hydrophobic coating, Tip Load 0.6 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 216 PTCA wire 0.014 0.014 coronary guidewire, Elastinite Nitinol core material, Intermediate polymer sleeve, Tip style: shaping ribbon, Hydrophillic coating, Tip Load 0.6 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 217 0.014 coronary guidewire, Elastinite Nitinol core material, Intermediate polymer sleeve, Tip style: shaping ribbon, Hydrophillic coating, Tip Load 0.7 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 218 PTCA wire 0.014 0.014 coronary guidewire, Stainless steel core material,Bare coil covering, Tip style: shaping ribbon, Hydrophillic/Hydrophobic coating, Tip Load 0.4 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 50 219 PTCA wire 0.014 0.014 coronary guidewire, Durasteel Stainless steel core material, Bare coil covering, Tip style: Core-to-tip, Hydrophillic coating, Tip Load 0.9 gm.(Support-Light/Moderate/Extra). Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 220 PTCA wire 0.014 0.014 coronary guidewire, Durasteel Stainless steel core material, Bare coil covering, Tip style: Core-to-tip, Hydrophillic coating, Tip Load 1.0 gm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 221 PTCA wire 0.014 .014 One Piece core workhorse wire with jointless Spring coil with slip coat coating over the sprig coil, tip load .8g ,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 222 PTCA wire 0.014 .014 One Piece core workhorse wire with jointless Spring coil, with Sion Tech, having composite core with ACTONE Inside, length 28cm with, tip load .7g ,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 223 PTCA wire 0.014 .014 One Piece core workhorse wire with jointless Spring coil with Sion Tech, having composite core with ACTONE Inside, length 20cm with, tip load .5g ,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 224 PTCA wire 0.014 014 One Piece core workhorse wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 0.8g ,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 225 PTCA wire 0.014 .014 One Piece core workhorse wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 1g,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or 51 therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 226 PTCA wire 0.014 .014 One Piece core Extra-support wire with jointless spring coil, PTFE coating over the shaft, tip load .7g,180cm length with tip radiopacity 4cm.Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 227 PTCA wire 0.014 014 One Piece core workhorse wire with jointless Spring coil, with Polymer Jacket with Sion Tech, having composite core with ACTONE Inside, length 28cm, with tip load .8g ,180cm length tip radiopacity 3cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 228 PTCA wire 0.014 .014 Extra support One Piece core extra-support wire with jointless Spring coil with Sion Tech, having composite core with ACTONE Inside, tip load .5g, length tip radiopacity 3cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 229 PTCA wire 0.014 .014 One Piece core specialty wire with jointless spring coil tapering to .009; 0.8gf of tip load; 16cm polymer sleeve length with slip coat coating over the polymer sleeve, 190cm length; tip radiopacity 16cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 230 PTCA wire 0.014 .014 One Piece core specialty wire with jointless spring coil tapering to .010; 1gf of tip load; 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length; tip radiopacity 16cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 231 PTCA wire 0.014 .014 One Piece core specialty wire with jointless spring coil tapering to .010; 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length; tip radiopacity 16cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 52 232 PTCA wire 0.014 .014 One Piece core CTO wire with jointless spring coil PTFE coating over the shaft, tip load 3g, 4.5g, 6g and 12g ,180cm length with tip radiopacity 11cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 233 PTCA wire 0.014 .014 One Piece core wire with jointless spring coil and slip coat on the spring coil, PTFE coating over the shaft, tip load 3g, ,180cm length with tip radiopacity 11cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 234 PTCA wire 0.014 Dedicated guidewire for externalization with tip load of 3g length 330cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 235 PTCA wire 0.014 One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to .009, tip load 9g ,180cm length tip radiopacity 20cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 236 PTCA wire 0.014 One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to .009, tip load 12g ,180cm length tip radiopacity 20cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 237 PTCA wire 0.014 One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to .008, tip load 20g ,180cm length tip radiopacity 17cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 238 PTCA wire 0.014 .0.014 coronary guidewire, Tip Flexibility Intermediate/Polymer, Tip Radiopacity 35 cm, Rail Support Light, Core Material Unibody stainless steel, Coating Hydrophilic, Extension Exchange Device. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 239 PTCA wire 0.014 .010 One Piece core wire with joint less Spring coil length 15cm, cone tip with a tip load of 1.7gm .190cm length tip radiopacity 15cm, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 240 PTCA wire 0.014 .012 One Piece core wire with joint less Spring coil length 15cm, cone tip with a tip load of 3.5gm190cm length tip radiopacity 15cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 53 241 PTCA wire 0.014 .010 One Piece core wire with joint less Spring coil length 15cm, cone tip with a tip load of 4.5 gm 190cm length tip radiopacity 15cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 242 PTCA wire 0.014 0.014 guidewire for exchange of microcatheters and other over-thewire devices; length 165 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 243 PTCA wire 0.014 0.014, Steel core, Spring coil tip, Core to tip design, Hydrophillic tip coating, 2.8 cm radiopaque, Light support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 244 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 0.8 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Light support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 245 PTCA wire 0.014 0.014, Steel core, Spring coil tip, Shaping ribbon design, 3.0g, 6.0g, 9.0g tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 246 PTCA wire 0.014 0.014, Steel core, Spring coil tip, Shaping ribbon design, 12.0g, 15.0g tip load, Hydrophillic tip coating, 3cm radiopaque, Extra support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 247 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 1.5 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 248 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 2.7 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 249 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 4.5 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 250 PTCA wire 0.014 0.010, Steel core, Spring coil tip, Core to tip design, 1.7 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque 54 strength, pyrogenicity and shelf life should be provided. 251 PTCA wire 0.014 0.010, Steel core, Spring coil tip, Core to tip design, 4.7 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 252 PTCA wire 0.014 0.010, Steel core, Coil tip, Core to tip design, 6.2g, 8.7g tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 253 PTCA wire 0.014 0.012, Steel core, Spring coil tip, Core to tip design, 4.8 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 254 PTCA wire 0.014 0.012, Steel core, Coil tip, Core to tip design, 9.7 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 255 PTCA wire 0.014 0.010, Steel core, Coil tip, Core to tip design, 13.9 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 256 PTCA wire 0.014 0.010, Steel core, Coil tip, Core to tip design, 12.5 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 257 PTCA wire 0.014 0.009, Steel core, Coil tip, Core to tip design, 13.3 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 258 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 1.0 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Moderate support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 259 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 1.2 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Extra support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 55 260 PTCA wire 0.014 0.014, Steel core, Spring coil tip, Core to tip design, 0.8 gm tip load, Hydrophillic tip coating, 3cm radiopaque, Light support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 261 PTCA wire 0.014 0.014, Steel core, Spring coil tip, Core to tip design, 0.9 gm tip load, Hybrid tip coating, 2.8 cm radiopaque, Extra support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 262 PTCA wire 0.014 0.014, Steel core, Polymer tip, Core to tip design, 1.2 gm tip load, Hydrophillic tip coating, 35 cm radiopaque, Extra support, Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 263 PTCA wire 0.014 014 Extra support One Piece core wire with jointless Spring coil with Sion Tech, having composite core with ACTONE Inside, lowest tip load .3g, length tip radiopacity 3cm, pre-shaped tip, 52 cm hydrophilic coating, available in 190 and 300cm lengths. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 264 PTCA wire 0.014 Extra Floppy wire with Polymer Sleeve Cover, All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 265 PTCA wire 0.014 Extra Floppy wire without Polymer Sleeve Cover for Retrograde purpose (Tip load ≤ 0.4 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 266 PTCA wire 0.014 Extra Floppy wire without Polymer Sleeve Cover (Tip load ≤ 0.4 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 267 PTCA wire 0.014 Floppy wire with extra support and Polymer Sleeve Cover (Tip load: 0.5 - 0.6 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 268 PTCA wire 0.014 Floppy wire with extra support and without Polymer Sleeve Cover (Tip load: 0.5 - 0.6 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 269 PTCA wire 0.014 Floppy wire without extra support and with Polymer Sleeve cover (Tip load: 0.5 - 0.6 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, 56 pyrogenicity and shelf life should be provided. 270 PTCA wire 0.014 Floppy wire without extra support and without Polymer Sleeve cover (Tip load: 0.5 - 0.6 gm), All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 271 PTCA wire 0.014 Special Exchange Wire, All Sizes, Straight / J tip. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. . 272 PTCA wire 0.014 Doc Extension wire, All Sizes, Straight / J tip Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 273 THROMBUS ASPIRATION CATHETERS Forward facing tip for effective thrombus aspiration. Hub to tip variable braiding, aspiration rate >50cc/min, Extended hydrophilic coating >35cm, 6 Fr compatible, Provided with a kit of 2 aspiration syringes, Extension tubing with stop cock and filter baskets, minimum 140 cm device length.. 274 SEMICOMPLIANT BALLOON CATHETER Small 1.0 and1.25 size Zero fold – Ideal for crossing complex and CTO lesions, Tip entry profile of .016’, Radioopaque marker bands, 6 Fr compatible for Kissing Ballon technique, balloon made of supple fulcrum material for better navigation, Flexible tip for better crossability, Diameters available 1.5, 2.0, 2.25, 2.5, 2.75, 3.0 3.5 4.0 mm, Lengths available in 6, 8, 10, 12, 15, 20, 22, 25 & 30 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 275 Non Compliant Balloon Catheter Low-Profile along with 0.41 mm (0.016”) lesion entry profile with Flexible Tip, Optimal Trackability with optimal lubricity with Minimum Edge Effect and Protecting Healthy Tissue, Low longitudinal growth (Less than 5% longitudinal growth at RBP) for more exact sizing, High-Pressure Capabilities Available in RX system, Available diameter 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5 , 4.0 mm, Lengths available 6, 9, 12, 15, 21 & 27 mm, entry profile of .016 and crossing profile of .026 for > 3mm balloon, Standard shaft length. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 276 High Pressure Balloon Non compliant, Multilayer Peripheral Balloon with Ultra high Pressure of 40 atm. Shaft lengths of 75 and 120 cm Sizes: Diameter (5mm to 12mm) Lengths (2, 4&6cm). 57 277 Coronary Ditation Catheter, Blloon (US FDA Approved) Specification - High Pressure Semi-Compliant PTCA Balloon. Must have Low Entry Tip Profile Equal to or less than 0.016”. Should have Nominal Pressure 6atm or above and RBP above 14atm. Balloon must have P-Tech Coating & Stainless Steel Hypotube for Kink Resistant & Superior Deliverability. Should have available in Diameter from1.0mm & smallest length 5mm onwards only. Quote both Monorail (Rapid Exchange) or OTW balloons. USFDA Approved. 278 Coronary Ditation Catheter, Blloon (CE Approved) Specification - Special PTCA Balloon for CTO Lesions starting diameter 0.85mm with RBP 16 atm or above. Must have Low Entry Tip Profile Equal to or less than 0.015”. Balloon Hypotube must be Stainless Steel along with having Spiral-Cut design for excellent force transmission from proximal shaft to distal tip. Should have Extended Guide wire lumen 30cm for better pushability in the CTO lesions. Quote both Monorail (Rapid Exchange) or OTW balloons. CE Approved. 279 Coronary Ditation Catheter, Blloon (CE Approved) Specification - Special PTCA Balloon (Non-Compliant) for Post Dilation. Must have diameter starting from 1.75mm-5.0mm. Balloon material must be Nylon for controlled compliance. Distal Tip must be Z-Tip for Zero Transition with conventional steerable guidewires. Quote both Monorail (Rapid Exchange) or OTW balloons. CE Approved. 280 Coronary Ditation Catheter, Blloon (US FDA Approved) Specification - High Pressure (Non-Compliant) PTCA Balloon made up of dual layer of Nylon & Pebax material for controlled Expansion & Apposition. Balloon must available in longest length of 22mm & 26mm. Should have High RBP of 24 atm. Available from smallest diameter 1.5mm-5.0mm. Quote both Monorail (Rapid Exchange) or OTW balloons. US FDA Approved. 281 Dedicated Trapping Balloon-TRAPPER 282 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent, Cobaltchromium platform with biodegradable polymer, Strut Thickness of 65-100microns, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 283 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent, Cobaltchromium platform with uniform small strut thickness of <65 µm in all diameters, 5F guide catheter compatible with diameter available from 2.25 mm to 4.0 mm and length available up to ≥48 mm in all diameters. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 58 year clinical follow up data should be available and provided. 284 Everolimus coated drug eluting coronary stent, Cobaltchromium platform with strut thickness <65µm, 5F guide catheter compatible with variable diameter and length available up to ≥48 mm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 285 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent with biostable polymer. Cobalt-chromium platform, strut thickness 65µm100µm, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 286 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent with abluminal coating and biodegradable polymer. Cobalt-chromium platform, strut thickness 65µm-100µm, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 287 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent, stainless steel platform, and biodegradable polymer, strut thickness 65µm100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 288 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent, stainless steel and biostable polymer, strut thickness 65µm-100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 59 289 Drug Eluting Stent (All Sizes) Everolimus coated drug eluting coronary stent, Open cell design Cobalt-chromium platform, biostable polymer, variable strut thickness of 65 to 100 µm depending on stent diameter for better radial strength, 5F guide compatible. Diameter available between 2.0 mm to 4.5 mm in different lengths. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 290 Drug Eluting Stent (All Sizes) Everolimus drug eluting coronary stent. Cobalt-chromium platform with strut thickness 65µm-100µm, with sizes available in 4.0, 4.5 and 5.0 mm for large vessel/left main angioplasty, minimum length from 8 – 10 mm and longer lengths of 10/12 mm, 15/18mm, 22/24 mm and longer. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 291 Drug Eluting Stent (All Sizes) Everolimus drug eluting coronary stent. Cobalt-chromium platform, Strut thickness 65µm-100µm with sizes available in 2.0 mm for small vessel angioplasty, minimum length from 10 – 12 mm and longer lengths of ≥32 mm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 292 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent. Cobalt-chromium platform with biodegradable polymer, Strut thickness 65µm100µm, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 293 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent, Cobalt-chromium platform with strut thickness of <65 µm, 5F guide catheter compatible with variable diameter and length available up to ≥48 mm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 60 294 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent with biostable polymer. Cobalt-chromium platform, Strut thickness 65µm100µm, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 295 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent with abluminal coating and biodegradable polymer. Cobalt-chromium platform, Strut thickness 65µm-100µm, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 296 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent, stainless steel platform, and biodegradable polymer, Strut thickness 65µm100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 297 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent, stainless steel platform, and biostable polymer, Strut thickness 65µm-100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 298 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting Tapered coronary stent with 0.5 mm difference of diameter between proximal and distal end. Cobaltchromium platform with biodegradable polymer, Strut thickness 65µm-100µm, different diameter of upto 4.5 mm (proximal end) and length available upto ≥50 mm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 299 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent with no polymer (polymer free stent), Strut thickness 65µm-100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and 61 diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 300 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent, micro-porous surface of metal platform for drug stability with thin layer of polymer, Strut thickness 65µm-100µm, with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 301 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent, Open cell design Cobalt-chromium platform, biostable polymer, Strut thickness 65µm-100µm, depending on stent diameter for better radial strength, 5F guide compatible. Diameter available from 2.0 mm to ≥4.5 mm in different lengths. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 302 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent dual drug with no polymer. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 303 Drug Eluting Stent (All Sizes) Sirolimus Eluting Coronary Stent, Bio degradable polymer, Hybrid open cell ,double - helix design, sine wave 3-3-3 link , strut thickness less than 100 µm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 304 Drug Eluting Stent (All Sizes) Sirolimus Eluting Coronary Stent Bio degradable polymer,Hybrid open cell, Double - helix design, sine wave 3- 3-3 link ,Strut thickness 65µm-100µm. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 62 305 Drug Eluting Stent (All Sizes) Sirolimus coated drug eluting coronary stent. Cobalt-chromium platform with Strut thickness 65µm-100µm, biodegradable polymer, entry profile 0.017” or less with lowest shaft profile, 5F guide compatible, different length and diameter. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 306 Bare Metallic Stent All Sizes. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. 307 COVER STENT (CORONARY) Made of Stainless Steel, Expandable Polytetrafluoroethylene (ePTFE) sandwiched between two identical stents, 0.52 mm double wall thickness, Semi Compliant balloon, Shaft size (2.0 - 2.7)F, 6F to 7F compatible guide catheter, 0.024 entry profile.. 308 Graft Master Covered Stent 309 PK Papyrus Stent 310 Drug Eluting Balloon (All Sizes) Sirolimus drug coated/eluting coronary balloon. Diameter (mm) 2.0, 2.5, 2.75, 3.0, 3.5, 4.0. Length (mm) 12 mm to 40 mm in various lengths.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 311 Drug Eluting Balloon (All Sizes) Paclitaxel drug coated/eluting coronary balloon. Diameter (mm) 2.0, 2.5, 2.75, 3.0, 3.5, 4.0. Length (mm) 12mm to 40 mm in various lengths.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 312 CTO Re-Entry Devices Needle based CTO devices (Re-Entry Devices) for Coronary - Needle based, All Sizes. 313 CTO Re-Entry Devices Balloon based CTO devices (Re-Entry Devices) for Coronary - Balloon based, All Sizes. 314 OPTICAL COHERENCE TOMOGRAPHY (OCT) CATHETER Guide catheter for intracoronary OCT, 0.014 guidewire and 6 F guide catheter compatibility. Lubricous hydrophilic coating and low tip entry profile for crossing tight, distal lesions.2.7 F crossing profile and supportive proximal shaft provide superb deliverability to the area of interest. Two radiopaque marker bands 20 cm apart allow segment length assessment and make it easy to position.. . 315 ROTA ASSEMBLY KIT (ALL SIZE) All Sizes. 63 316 CORONARY SNARE Made of a Nitinol shaft and a loop connected together on the tapered section of the nitinol shaft by shrinking compression force of PTFE heat shrink tubing. The loop is made of braided Nitinol wires coiled with Titanium Nitride coated tungsten wire to enhance radiopaque. Goose neck micro snare with size 4mm and 7 mm.. 317 Microsnare Single loop Micro-Snare with Retrieval Catheter, Loop Dia. 2 to 7 mm, Catheter size: 2.3-3 Fr. 318 Snare Coronary Single loop Snare with Retrieval Catheter, Loop Dia. 5 to 35 mm, Catheter size: 4 Fr. 319 Snare Coronary Single loop Snare with Retrieval Catheter, Loop Dia. 5 to 35 mm, Catheter size: 5 Fr. 320 Snare Coronary Single loop Snare with Retrieval Catheter, Loop Dia. 5 to 35 mm, Catheter size: 6 Fr. 321 Snare Coronary Single loop Snare with Retrieval Catheter, Loop Dia. 5 to 35 mm, Catheter size:7 Fr. 322 Snare Coronary Multi-loop Snare with Retrieval Catheter, Loop Dia. 2 to 45 mm, Catheter size: 3 Fr. 323 Snare Coronary Multi-loop Snare with Retrieval Catheter, Loop Dia. 2 to 45 mm, Catheter size: 4 Fr. 324 Snare Coronary Multi-loop Snare with Retrieval Catheter, Loop Dia. 2 to 45 mm, Catheter size: 5 Fr. 325 Snare Coronary Multi-loop Snare with Retrieval Catheter, Loop Dia. 2 to 45 mm, Catheter size: 6 Fr. 326 Snare Coronary Multi-loop Snare with Retrieval Catheter, Loop Dia. 2 to 45 mm, Catheter size: 7 Fr. 327 PERIPHERAL SNARE Made of a Nitinol shaft and a loop connected together on the tapered section of the nitinol shaft by shrinking compression force of PTFE heat shrink tubing. The loop is made of braided Nitinol wires coiled with Titanium Nitride coated tungsten wire to enhance radiopaque. Goose neck macro snare with size 5 mm to 35 mm.. 328 Bioptome with Delivery Set All Sizes. Clinically used for minimum 10 years . Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 329 IABP BALLOON KIT Size 25 Compatible with Getinge CS300, Fibre Optic pressure Transmission and Intellisense Technology. 64 330 IABP BALLOON KIT Size 30 Compatible with Getinge CS300, Fibre Optic pressure Transmission and Intellisense Technology. 331 IABP BALLOON KIT Size 34 Compatible with Getinge CS300, Fibre Optic pressure Transmission and Intellisense Technology. 332 IABP BALLOON KIT Size 40 Compatible with Getinge CS300, Fibre Optic pressure Transmission and Intellisense Technology. 333 Renal Cobalt Chromium Balloon Mounted Stent Monorail System, 6 Fr / 7 Fr Guide Catheter compatible, Wire Diameter: 0.014 compatible Nominal Pressure: 10 to 12 atm, RBP : 12 to 14 atm. 334 RENAL STENT Balloon mounted renal stent, 0.018” compatible, various diameters of 5mm, 6mm, 7mm, 8mm and various length of 10-12 mm to 18-20 mm.. 335 Embolisation Particles Embolization Particles, sealed in bottle, colour coded, 90 to 2000 micron. 336 Embolisation Coils Detachable coils , Platinum coils with Nylon & PGLA Helical fibres with LatticeFX technology, For embolizing peripheral arteries , 0.018 thickness, 0.0165 and 0.021 Microcatheter compatible. 337 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.018 Microcatheter compatible. 338 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.021 Microcatheter compatible. 339 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.032 Microcatheter compatible. 340 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.035 Microcatheter compatible. 341 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.038 Microcatheter compatible. 342 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.018 Microcatheter compatible. 65 343 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.021 Microcatheter compatible. 344 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.032 Microcatheter compatible. 345 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.035 Microcatheter compatible. 346 Embolisation Coils Embolization Coil, Non - Detachable / Pushable Loop Dia.: 2 mm and above Coil Length: 3 cm and above, 0.038, Microcatheter compatible. 347 Perforation coils 348 Perforation Injectable materials 349 VT Ablation 1 1 Fixd Quadripolar Catheter 2 2 Fixd Quadripolar Catheter 1 3 Deflectable Decapolar Catheter 1 4 Therapy Ablation Catheter 1 5 Fixd Quadripolar Cable 3 6 Deflectable Decapar Cable 1 7 Therapy Ablation Cable 1 8 Femoral Sheath 6F 3 9 Femoral Sheath 8F 1 TOT AL 350 VT Ablation 2 1 Fixd Quadripolar Catheter 1 2 Deflectable Decapolar Catheter 1 3 Therapy Ablation Catheter 1 4 Fixd Quadripolar Cable 3 5 Deflectable Decapar Cable 1 6 Therapy Ablation Cable 1 7 Femoral Sheath 6F 3 8 Femoral Sheath 8F 1 TOT AL 66 351 PSVT 1 3D Navix Patch 1 2 HD Grid Catheter 1 3 HD Grid Cable 1 4 Flexability AblationCathetetr 1 5 Flexability AblationCable 1 6 Cool Point Tubing Set 1 7 Femoral Sheath 6F 3 8 Femoral Sheath 8F 1 TOT AL 352 AF Ablation 1 3D Navix Patch 1 2 Viewflex ICE Catheter 1 3 Afocus/Optima AF Mapping 1 4 Afocus/Optima AF Cable 1 5 Duodecapolar Catheter 1 6 Duodecapolar Cable 1 7 Tacticath Catheter 1 8 Cool Point Tubing Set 1 9 Swartz SL1 Sheath 2 10 Agiis Sheath 1 11 BRK Transseptal Needle 1 12 Femoral Sheath 6F 3 13 Femoral Sheath 8F 1 TOT AL 353 PACEMAKER VVIR MRI 1 Vicryl cutting 3.0 2 Silk Cutting Body 2.0 3 Femoral arterial introducer sheath set* 4 Temporary Pacemaker Lead 5 Device with all accessories TOTAL 354 PACEMAKER DDDR MRI 1 Vicryl cutting 3.0 2 Silk Cutting Body 2.0 3 Femoral arterial introducer sheath set* 4 Temporary Pacemaker Lead 5 Device with all accessories TOTAL 67 355 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI )/ (Dual Chamber MRI ) 1 Vicryl cutting 3.0 2 Silk Cutting Body 2.0 3 Femoral arterial introducer sheath set* 4 Temporary Pacemaker Lead 5 Device with all accessories TOTAL 356 CARDIAC RESYNCHRONISATI ON THERAPY - Pacing BIPOLAR MRI/ QUADRIPOLAR MRI 1 Vicryl cutting 3.0 2 Silk Cutting Body 2.0 3 Femoral arterial introducer sheath set* 4 Temporary Pacemaker Lead 5 Device with all accessories TOTAL 357 CARDIAC RESYNCHRONISATI ON THERAPY DEFIBRILATOR BIPLOAR MRI/ QUADRIPOLAR MRI 1 Vicryl cutting 3.0 2 2 Silk Cutting Body 2.0 2 3 Femoral arterial introducer sheath set* 1 4 Temporary Pacemaker Lead 1 5 Device with all accessories 1 TOTAL 358 Physiological pacing (Left bundle branch pacing) kit with VVIR MRI 1 Vicryl cutting 3.0 2 2 Silk Cutting Body 2.0 2 3 Femoral arterial introducer sheath set* 1 4 Temporary Pacemaker Lead 1 5 Device with all accessories 1 TOTAL 359 Physiological pacing (Left bundle branch pacing) kit with DDR MRI 1 Vicryl cutting 3.0 2 2 Silk Cutting Body 2.0 2 3 Femoral arterial introducer sheath set* 1 4 Temporary Pacemaker Lead 1 5 Device with all accessories 1 TOTAL 68 360 TEMPORARY PACING LEAD 4F, 5F, 6F, and 7F Sizes. 361 Balloon Tipped Pacing Leads Balloon Tipped Temporary pacing leads are sterile, disposable, non toxic, pyrogene free medical devices made of biocompatible material visible under fluoroscopy. It must have design to work with all avaible pacemakers including pacemakers having sockets for shrouded pin. For this purpose, the electrode is equipped with special adapter, which may be fastened on the standard plug for connecting the lead with pacemaker accepting shrouded pins. It should hve Atraumatic Tip, Colour coding for sizes, Shrouded pin 5Fr, 1250mm Total Length,1120 Usable Length, 4-10 Electrode Spacing, Resistance 12 Distal & 34 Proximal. Colour of Hub: - White 6Fr, 1250mm Total Length,1120 Usable Length, 4-10 Electrode Spacing, Resistance 8 Distal & 22 Proximal. Colour of Hub: -Blue 7Fr, 1250mm Total Length,1120 Usable Length, 4-10 Electrode Spacing, Resistance 8 Distal & 22 Proximal. Colour of Hub: - Yellow. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 362 PACEMAKER DDDR MRI Double Chamber Pacemaker DDDR MRI-3T Compatible, Lung impedence monitoring,RF, Radiofrequency immunity, Small weight and size. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 363 PACEMAKER DDDR MRI MR-Conditional models available with MRI Unlimited with no exclusion zones, pacemakers with both 3T and 1.5T conditionality, no scan time limits, automatic MRI timeout, high SAR limits, and no patient restrictions •Autothreshold in RA/RV, respiration-based therapy and diagnostics. Conducted AF response, PMOP(post mode switch overdrive pacing). Small Size and Low Weight, Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 69 364 PACEMAKER DDDR MRI MR-Conditional models available with MRI Unlimited with no exclusion zones, pacemakers with both 3T and 1.5T conditionality, no scan time limits, automatic MRI timeout, high SAR limits, and no patient restrictions •Autothreshold in RA/RV. Continuous remote montoring via smart phone. Small Size and Low Weight. Over 12 years of longevity.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 365 PACEMAKER VVIR MRI Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. Mass<25gm, Automatic Pacing, Sensing, and Lead Monitor Implant Detection and Initialization At the completion of the 30-minute Implant Detection period, Rate Profile Optimization is enabled; the appropriate pacing and sensing polarities are automatically selected by the device; Ventricular Output Management is enabled and Amplitude and Pulse Width become adaptive. Sensing enabled and Sensitivity becomes adaptive. Conducted AF response, Approved for 1.5T and 3T MRI uses, full body Mri, No exclusion zone. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 366 Remote Monitoring Device Compatible with the pacemaker implanted. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE MPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI ) Multiple programmable options to reduce inappropriate and unnecessary shocks, including a choice of rhythm discriminators, antitachycardia pacing (ATP) therapy in all rates zones, and advanced sensing and filtering. Technology is intended to provide lifesaving shock therapy and basic pacing functionality in the event of an unrecoverable fault. DF4 COMPATIBLE, RAMP THERAPY PARAMETERS, RATE RESPONSE PACING PARAMETERS, Approved for 1.5T and 3T MRI uses, full body Mri, No exclusion zone, No Height N weight Restrictions. Small Size and low Weight. Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 368 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI ) Multiple programmable options to reduce inappropriate and unnecessary shocks, including a choice of rhythm discriminators, antitachycardia pacing (ATP) therapy in all rates zones, and advanced sensing and filtering. Technology is intended to provide lifesaving shock therapy and basic pacing functionality in the event of an unrecoverable fault. DF4 COMPATIBLE, RAMP THERAPY PARAMETERS, RATE RESPONSE PACING PARAMETERS, AF Diagnostic ability, Approved for 1.5T and 3T MRI uses, full body Mri, No exclusion zone, No Height N weight Restrictions. Small Size and low Weight. Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 369 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI ) ICD single chamber, MRI-1.5T or3T Compatible, Remote monitoring through bluetooth,36J energy delivery, feature intended to identify occurrences of polymorphic VT or VF that are at risk of under-detection and/or undertreatment at the current , Small weight and size, . Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 71 370 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI )I CD single chamber, MRI Compatible,Automatic senstivity,along with programing algorithm to discriminates between complex rhythms that require defibrillation therapy and those that do not, advance sensing to avoid sensing unwanted signals, Small weight and size. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 371 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (DUAL CHAMBER MRI ) Complete Capture Management , RAMP & Burst therapy, Reactive ATP, ATRIAL & Rv capture management, rate drop response. Small Size and low Weight. Approved for 1.5T and 3T MRI uses, full body Mri, No exclusion zone. Fluid status monitoring. Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 372 IMPLANTABLE CARDIOVERTER DEFIBRILATOR (DUAL CHAMBER MRI ) ICD Double chamber,MRI-3T compatible, Remote Monitoring through Bluetooth, feature intended to identify occurrences of polymorphic VT or VF that are at risk of under-detection and/or undertreatment at the current programmed settings, Small weight and size. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 373 CARDIAC RESYNCHRONISATION THERAPY - Pacing BIPOLAR MRI Small Size and low Weight., IS 1 compatible, 3T MR Conditional WITH no exclusion zone, no height n weight n time restrictions, Bluetooth Wireless Telemetry, CardioSync Optimisation, fluid status monitoring, Complete Capture Management Diagnostic (ACM, RVCM, LVCM). Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity 72 and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 374 CARDIAC RESYNCHRONISATION THERAPY - Pacing QUADRIPOLAR MRI Small Size and low Weight., DF4 compatible, 3T MR Conditional WITH no exclusion zone, no height n weight n time restrictions, Bluetooth Wireless Telemetry, LV AUTOMATED TEST, CardioSync Optimisation, fluid status monitoring, Complete Capture Management Diagnostic (ACM, RVCM, LVCM), Conducted AF response influenced pacing. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 375 CARDIAC RESYNCHRONISATION THERAPY - Pacing QUADRIPOLAR MRI Biventricular Pacing CRT-P,Quadripolar, Multiple point pacing,MRI compatible, Synchronised AV algorithm, small weight and size.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 376 CARDIAC RESYNCHRONISATION THERAPY DEFIBRILATOR BIPLOAR MRI 1.5 Tesla MRI conditional Cardiac Re synchronization Therapy Defibrillator with Quadripolar LV Lead a .Ture LV sensing with more than 5 Lv sensing configurations. Respiration and activity based rate modulation . Respiratory Rate trending . .Daily trend forlast 365 day for Heart rate variability , Lead impedances, Amplitudes , Activity Levels.At least 17 LV pacing vectors. Automatic recommendation of LV pacing sequence which automatically recommends pacing sequence, pacing vectors, and pacing characteristics (amplitude and pulse width) based on RVSLVS delay and electrode separation distance. Maximum labled Longevity of 8-9 years at 100% Bi V Pacing . In built safety mechanism intended to provide lifesaving shock therapy and basic pacing functionality in the event of an unrecoverable fault. Autonomic Balance Monitor diagnostic for Heart Failure . Bluetooth 73 Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 377 CARDIAC RESYNCHRONISATION THERAPY DEFIBRILATOR QUAD MRI 1.5 Tesla MRI conditional Cardiac Re synchronization Therapy Defibrillator with Quadripolar LV Lead a .Ture LV sensing with more than 5 Lv sensing configurations. Respiration and activity based rate modulation . Respiratory Rate trending . .Daily trend forlast 365 day for Heart rate variability , Lead impedances, Amplitudes , Activity Levels.At least 17 LV pacing vectors. Automatic recommendation of LV pacing sequence which automatically recommends pacing sequence, pacing vectors, and pacing characteristics (amplitude and pulse width) based on RVSLVS delay and electrode separation distance. Maximum labled Longevity of 8-9 years at 100% Bi V Pacing . In built safety mechanism intended to provide lifesaving shock therapy and basic pacing functionality in the event of an unrecoverable fault. Autonomic Balance Monitor diagnostic for Heart Failure .. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 378 CARDIAC RESYNCHRONISATION THERAPY DEFIBRILATOR QUAD MRI Biventricular Pacing CRT-D,1.5T or 3T MRI compatible, Multiple point pacing, 40J energy delivery, Remote Monitoring thorugh Blutooth, LV capture to descriminate various rhythm, Algorithm to Synchronise and dynamically adjusts AV delays based on the patients intrinsic conduction, MRI timeout, feature intended to identify occurrences of polymorphic VT or VF that are at risk of under-detection and/or undertreatment at the current programmed settings, small weight and size. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and 74 provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 379 CARDIAC RESYNCHRONISATION THERAPY DEFIBRILATOR MRI Approved for 1.5T and 3T MRI uses, full body Mri, No exclusion zone, No Height N weight Restrictions, Adaptive CRT Algorithm, CardioSync Optimisation, Fluid Status Monitoring, MVP Mode with Complete Capture Management Diagnostic (ACM, RVCM, LVCM), Multiple Point Pacing, Volume ≤ 35 cm3. Bluetooth Wireless Telemetry.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 380 Permanent pacing lead Active fixation . 381 Permanent defibrillation lead 382 LV LEADS, ALL TYPES BIPOLAR, QUADRIPOLAR, MULTISITE, ETC. . 383 LV LEAD DELIVERY SYSTEM DEDICATED CATHETER FOR ENGAGING/HOOKING CORONARY SINUS, CS SUBSELECTOR, ETC.. 384 Dilator Sheath Set All sizes. 385 Mechanical Rotating Dilator Sheath All sizes. 386 Subcutaneous ICD Provide ability to implant subcutaneous defibrillation device. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 387 Physiological pacing (Left bundle branch pacing) kit with VVIR MRI With all accessories 388 Physiological pacing (Left bundle branch pacing) kit with DDDR MRI With all accessories. APPLICABLE ONLY FOR PARTICIPANTS 75 WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 389 TRANS SEPTAL PUNCTURE NEEDLE ADULT The stainless steel Brockenbrough needle with tapered tip and base dial used to make the transseptal puncture. 18G Shaft, 21 G Tip with 71 cm length.. 390 TRANS SEPTAL PUNCTURE NEEDLE PED. The stainless steel Brockenbrough needle with tapered tip and base dial used to make the transseptal puncture. 19G Shaft, 22 G Tip with 56 cm length.. 391 LEFT ATRIAL WIRE Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 392 ASD CLOSURE DEVICE ASD Occluders are a percutaneous, transcatheter closure device for the non-surgical closure of atrial septal defect. The ASD Occluders are self-expandable double disc devices, which are made of a nitinol wire mesh that is shaped into two flat discs and a waist between the two discs. PET membranes sewn into each disc and the waist which helps to seal the hole and provide a foundation for tissue growth over the occluder after it is implanted in the heart. Introducer System for ASD/VSD/PDA delivery kit containing i) delivery sheath with back bleed prevention hemostatic valve and side port, ii) dilator, iii) delivery cable, iv) loader. 5/6/7/8/9/10/11/12/13/14F.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 393 PDA CLOSURE DEVICE The PDA Occluder is a percutaneous, transcatheter occluding device for the non-surgical closure of patent ductus arteriosus defects. The device consists of a knitted nitinol wire mesh, which has been heated and set to expand into a T-shape. The disc on the aorta side is designed to hold the plug at the orifice of the ductus arteriosus, while the waist expands to fill and occlude it. Two PTFE membranes are sewn inside the waist to help block the abnormal blood flow from the aorta into the pulmonary artery. Introducer System for ASD/VSD/PDA delivery kit containing i) delivery sheath with back bleed prevention hemostatic valve and side port, ii) dilator, iii) delivery cable, iv) loader. 5/6/7/8/9/10/11/12/13/14F.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE 76 WHOLE PACKAGE. 394 PDA COILS Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 395 VSD CLOSURE DEVICE The VSD Occluder is a percutaneous, transcatheter closure device for the non-surgical closure of a ventricular septal defect in patients. The occluder is a self-expandable, double discs device made from a nitinol wire mesh. The two discs are linked together by a short cylindrical waist matching with the size of the VSD., The discs and waist are filled with PTFE membranes securely sewn to the device by nylon threads to increase closing ability of the occluder and reduce the residual shunts. Introducer System for ASD/VSD/PDA delivery kit containing i) delivery sheath with back bleed prevention hemostatic valve and side port, ii) dilator, iii) delivery cable, iv) loader. 5/6/7/8/9/10/11/12/13/14F.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 396 Multi Funtional Occluder (MFO) DEVICEs with PTFE/without PTFE Elongatable waist designed for a variety of VSDs, Paravalvur Leak, AP Windows, AV Fistulas & RSOV cases. Soft woven nitinol mesh that provides high conformability to septal defects. Having Low Delivery Profile as low as 4F and maximum to 7F. It is equipped with double-sided retention screw for retrograde & antegrade approach. Introducer System for ASD/VSD/PDA delivery kit containing i) delivery sheath with back bleed prevention hemostatic valve and side port, ii) dilator, iii) delivery cable, iv) loader. 5/6/7/8/9/10/11/12/13/14F.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 77 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. APPLICABLE ONLY FOR PARTICIPANTS WHO HAVE QUOTED FOR THE WHOLE PACKAGE. 397 LEFT ATRIAL APPENDAGE CLOSURE (LAA-CLOSURE) LEFT ATRIAL APPANDAGE CLOSURE DEVICE having an umbrella design, which is fully retrievable and repositionable. Round U-Shaped Ends to trap trabeculations. Low Profile 8F-10F. It comes in differenet lobes, Single and Multiple. . Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. 398 PARAVALVULAR LEAK CLOSURE DEVICE Paravalvular leak closure device with all standard accessories. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. 399 PFO CLOSURE DEVICE Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for pyrogenicity and shelf life should be provided. 400 Vascular Plug a self-expandable, cylindrical device made of a Ni-Ti wire mesh with Membrane. The device is fixed on the both ends with a stainless steel sleeve. One stainless steel micro screw (nut) is welded to one end of the device. A 110cm long delivery cable is allowed to connect with stainless steel micro screw in order to access or retrieve. A PTFE membrane, designed to help seal the hole and to obstruct blood flow after plug placement, is sewn into the device. . Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 401 COARCTATION DILATATION BALLOON 402 AORTIC ANEURISM STENT GRAFT Endovascular stent graft device for the treatment abdominal aortic aneurysm or dissection. Device should be without proximal barbs with distal and or proximal bare spring configuration and tapered available in any or more of the following sizes OD 20-44mm, 78 Length 8-20cm. It should be able to be advanced up to 24 shaft. Sheath should be Hydrophilic Coating. . 403 AORTIC ANEURISM STENT GRAFT Endovascular stent graft device for the treatment iliac aneurysm or dissection. Device should be without proximal barbs with distal or proximal bare spring configuration. It is an extension to AAA Graft System. And, can be used for the Iliac Artery Aneursym or Dissections. . 404 AORTIC ANEURISM STENT GRAFT Endovascular stent graft device for EVAR of Abdominal Aortic Aneurysm or Dissection with tapered system. Device should be without proximal barbs with distal and or proximal bare spring configuration and tapered available in any or more of the following sizes OD 20-44mm, Length 8-20cm. It should be able to be advanced up to 24 shaft. Sheath should be Hydrophilic Coating. . 405 Graft Stent For Aneurysm Of Aorta a. For Thoracic Aorta - Covered (For Aneurysm / Dissection), - With Barbs, Straight / Tapered, Good Conformability, Flexible, With markers - Proximal & Distal, Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 406 Graft Stent For Aneurysm Of Aorta b. For Thoracic Aorta - Covered (For Aneurysm / Dissection), - Without Barbs, Straight / Tapered, Good Conformability, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 407 Graft Stent For Aneurysm Of Aorta c. For Thoracic Aorta - Bare (For Dissection), Straight / Tapered, Good Conformability, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 79 408 Graft Stent For Aneurysm Of Aorta d. For Abdominal Aorta (Bifurcated) - With Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 409 Graft Stent For Aneurysm Of Aorta g. For Abdominal Aorta (Uni-Iliac) - Without Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 410 Graft Stent For Aneurysm Of Aorta h. For Abdominal Aorta (Tube Graft) - With Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 411 Graft Stent For Aneurysm Of Aorta i. For Abdominal Aorta (Tube Graft) - Without Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal, Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 412 Graft Stent For Aneurysm Of Aorta j. For Abdominal Aorta (Iliac Extension) - With Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 80 413 Graft Stent For Aneurysm Of Aorta k. For Abdominal Aorta (Iliac Extension) - Without Barbs, Good Conformability, Self-expanding, Flexible, With markers - Proximal & Distal Note: Following accessories must be supplied as Complimentary along with Graft Stent; - Marker Pigtail (1 No.), - Compliant balloon for post dilatation (1 No.), - Super stiff / extra stiff 0.035 wire with exchange length (1 No.), - up to 24 Fr sheath (1 No.). 414 Thoracic Stent Graft Delivery System Thoracic Stent Graft Delivery System, 22mm – 46mm diameter. Length available 100mm, 150mm and 200mm, Starting from 22 Fr, 0.035 Wire Compatible, Varied options available - Contralateral, Limb extensions, Abdominal tubes and Bifurcations., Designs - Free flow straight, freeflow tapered, Closed web straight, Closed web tapered, Distal Bare. Spring Straight, High flexibility and conformability, Low profile, hydrophilic delivery system, Distinct Radiopaque Markers. 415 COARCTATION STENT Self-Expandable Platinum Iridium Aortic stent Diameter 8-24 mm, length 30-80mm.. 416 COARCTATION STENT Covered Self-Expandable covered Aortic stent Diameter 8-24 mm, length 30- 80mm.. 417 AAA Balloon OTW balloon, Low pressure balloon, Used in AAA indication . 418 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) 1 With all accessories 1 419 2 Balloon Expanding TAVI Valve/ Self Expanding TAVI Valve 1 420 3 ACT Kit 4 421 TOTAL 422 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For horizontal aorta(angulation > 48 degree and the centreline of the ascending aorta on the pre procedural CT)- incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath; incorporates an additional outer PET sealing cuff intended to reduce paravalvular regurgitation (COMPLETE PACKAGE) 423 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For horizontal aorta(angulation > 48 degree and the centreline of the ascending aorta on the pre procedural CT)- incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath; 81 incorporates an additional outer PET sealing cuff intended to reduce paravalvular regurgitation. axial self alignment of valve within the native annulus , extra large open cells to facilitate coronary access; porcine pericardium leaflets with biofix anti calcification process (COMPLETE PACKAGE) 424 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For small native femoral vessel size (-5mm)- features a supraannular, self-expanding nitinol frame with a low delivery profile.elfexpanding nitinol frame enhances the ability to conform and seal to the native annulus. The supra-annular leaflet position keeps the working portion of the valve above and unconstrained by the native annulus.Supra-annular valve design maximizes leaflet coaptation and promotes single digit gradients and large EOA’s. (COMPLETE PACKAGE) 425 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For BAV- self-expanding transcatheter aortic valve features a unique valve design with an outer wrap that adds surface area contact between the valve and the native aortic annulus to further advance valve sealing performance. with added external porcine; with pericardial wrap- External wrap covers first 1½ inflow cells and extended skirt (COMPLETE PACKAGE) 426 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For native valve AR- transapical system consists of a full porcine root valve mounted on a low-profile self-expanding nitinol stent, relies on an active clip fixation of the native aortic valve leaflets, thereby eliminating great radial forces on cardiac and aortic structures. manufactured in three different sizes (23 mm, 25 mm, and 27 mm) for implantation in native aortic annuli ranging from 21 mm to 27 mm in diameter. A sheathless 32 Fr delivery catheter is utilised for the three-step deployment procedure (COMPLETE PACKAGE) 427 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For native valve AR- ranscatheter Aortic Valve with U-shaped “anchor rings” facilitate accurate self-positioning of the replacement aortic valve, With five different valve sizes, Low profile design minimizes risk of coronary blockage. composed of a bioprosthetic valve and a transapical delivery catheter. The bioprosthetic valve is a porcine valve supported by a self-expanding nitinol structure of different sizes: external diameters of 21, 23, 25, 27, and 29 mm. (COMPLETE PACKAGE) 428 TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) For ViV TAVR-transcatheter heart valve (THV) is comprised of a balloon-expandable, radiopaque, cobalt- chromium frame, trileaflet bovine pericardial tissue valve, and a polyethylene terephthalate (PET) fabric skirt. The leaflets are treated according to the Carpentier-Edwards ThermaFix process. available in the 23, 26, and 29 mm sizes. (COMPLETE PACKAGE) 82 429 BALLOON MITRAL VALVOTOMY 1 GL Catheter with guide wire * 1 2 Pigtail Catheter * 2 3 Guide wire J tip* 0.32 - 0.38 1 4 Femoral arterial introducer sheath set* 1 5 Venous sheath set * 1 6 Three port manifold 1 7 Pressure line 1 8 Inj. Iohexol 350 100ml vial 1 9 MITRAL BALLON VALVOTOMY SET * 1 a · Mitral Balloon * 1 b · Mullin’s sheath * 1 c · Balloon stretching tube * 1 d · Stylet * 1 e · Dilator * 1 f LA Wire 1 g · Septum puncture needle * 1 TOTAL 430 PULMONARY BALLOON VALVOTOMY 1 Femoral arterial introducer sheath set* 1 2 Three port manifold 1 3 Pressure line 1 4 Pulmonary Balloon Catheter 1 5 Rapid HBsAg Rapid Screen Test + AMPLATZ WIRE 1 TOTAL 431 Mitra Clip Procedure 1 Pigtail Catheter * 1 2 Guide wire J tip* 0.32 - 0.38 X 260 1 3 Femoral arterial introducer sheath set* 1 4 Two port manifold 1 5 Pressure line 1 6 BTK Needle 1 7 Septal Dilator * 1 8 Septum puncture needle * 1 9 Mitra Clip Device set with all accessories 1 83 TOTAL 432 Paravalvular Leak Closure 1 Pigtail Catheter * 1 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32-0.38 X 260 1 4 Angled Tip Hydrophillic wire 0.32 X 260 1 5 Power Injector Syringe 1 6 Femoral arterial introducer sheath set* 2 7 Two port manifold 1 8 Pressure line 1 9 Closure Device set* (Closure Device + Delivery Systam) 1 10 ACT Kit 2 TOTAL 433 BMV KIT (Balloon with vent tube, shaper, Strightner, Pigtail wire, Calliper, Sizing Syringe, Septal Dilator) Double lumen PTMC balloon with vent tube and hole in the outer layer of the balloon, different sizes, with all accessories.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 434 BMV KIT (Balloon without vent tube, shaper, Strightner, Pigtail wire, Calliper, Sizing Syringe, Septal Dilator Mitral Valvuloplasty double lumen balloon with no hole on the balloon wall, no vent tube, different sizes, with all accessories.. Gone through 4 phase of trials. Safety profile assessed over large and diverse patient population. Primary endpoint data after 12 month should be available and provided. 5 year clinical follow up data should be available and provided. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. 435 BMV SEPTAL DILATOR Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 436 BAV/BPV Balloon Pulmonary / Aortic Valvuloplasty Balloon Catheter, 0.014 Wire, Size Dia: 4 to 10 mm; Length: 1 to 6 cm. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided 437 BAV/BPV Balloon Pulmonary / Aortic Valvuloplasty Balloon Catheter, 0.021 / 0.025 / 0.035 Wire, Size Dia: 4 to 30 mm; Length: 2 to 10 cm. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 438 BAV/BPV Balloon Pulmonary / Aortic Valvuloplasty Balloon Catheter for difficult balloon positioning (Dumbbell Shape), 0.035 wire, All Sizes. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 439 PERIPHERAL ANGIOPLASTY (BALLOON MOUNTED STENT) 1 Percutaneous Suture 2 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32-0.38 X 260 1 4 Straight Tip Hydrophillic wire 0.32 X 260 1 5 Long Sheath (8 French) 1 6 Pigtail Catheter 6 French 2 7 Femoral arterial introducer sheath set* 1 8 Three port manifold 1 9 Pressure line 2 10 Power Injector Syringe 1 11 Balloon mounted stent - SIZE / QUALITY 1 12 ACT Kit 2 TOTAL 440 PERIPHERAL ANGIOPLASTY (SELF EXPANDING STENT) 1 Percutaneous Suture 2 2 Diagnostic Catheter (MPA/JR/AL1) 1 3 Extrastriff Guide wire J tip* 0.32-0.38 X 260 1 4 Straight Tip Hydrophillic wire 0.32 X 260 1 5 Long Sheath (8 French) 1 6 Pigtail Catheter 6 French 2 7 Femoral arterial introducer sheath set* 1 8 Three port manifold 1 9 Pressure line 2 10 Power Injector Syringe 1 11 Self Expanding stent 1 12 ACT Kit 2 TOTAL 85 441 Peripheral Guide Catheter Multiple Curves Renal Curve, Renal Double Curve, Sheperds Crook, Champ etc and Various Sizes. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 442 PERPHERAL DIAGNOSTIC CATHTER ALL SIZES SHAPE 4F, 5F and 6 F 65,100 & 125 cm length 1200PSI (Shapes – H1, SIM, Cobra, VER, MPA, STR, BER, RDC) . Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 443 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.014, Length: 120-180 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 444 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.014, Length: 260-300 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 445 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.018, Length: 120-180 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 446 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.035, Length: 120-180 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 447 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.018, Length: 260-300 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 448 Peripheral Guide Wire Guide wire for Peripheral, Straight & J tip, Size 0.035, Length: 260-300 cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 449 PERIPHERAL Wire 0.035 Flexible guidewire, Soft atraumatic straight or J tipped, and provide enough support to deliver diagnostic devices, spring coil tip. Moderate rail support, Low lubricity, made of stainless steel, PTFE coated, Length 100-300cm.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 86 450 PERIPHERAL Wire 0.035 Flexible guidewire, steerable and navigate tortuous anatomy, Soft atraumatic straight tipped. Moderate rail support, High lubricity, spring coil tip, made of stainless steel, Hydrophillic. Used for Moderate access wire for catheter placement and exchange, Length 180-260cm.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 451 PERIPHERAL Wire 0.035 Flexible guidewire, Designed to provide increasing tip stiffness and excellent torque response to successfully cross lesions, Soft atraumatic straight/angled/J tipped. Moderate rail support, High lubricity, made of nitinol, Hydrophillic. Used for access and crossing. , Length 80-260cm.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 452 PERIPHERAL Wire 0.035 Flexible guidewire, Soft atraumatic J tipped. Super rail support, Low lubricity, spring coil tip, made of stainless steel, PTFE coated, Length 185-300cm, Designed to provide additional support for delivery of large devices and may aid in vessel straightening. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 453 PERIPHERAL Wire 0.018 Flexible guidewire, Tip load of 2-4 gm, Soft atraumatic straight or J tipped, spring coil tip. Extrasupport rail support, Moderate lubricity, made of stainless steel, silicon coated, Length 130-300cm. Designed to access and crossing lesions within acutely angled vessels. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 454 PERIPHERAL Wire 0.018 Flexible guidewire, Tip load of 6-8 gm, Soft atraumatic straight tipped, polymer sleeve tip. Moderate rail support, High lubricity, made of stainless steel, Hydrophillic, Length 110-300cm. Designed to cross lesions as step up strategy.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 455 PERIPHERAL Wire 0.018 Flexible guidewire, Tip load of 8 gm, Soft atraumatic straight/angled tipped, nitinol tip. Moderate rail support, High lubricity, made of nitinol, Hydrophillic, Length 150-180cm. Designed to cross lesions as step up strategy.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 456 PERIPHERAL Wire 0.018 Flexible guidewire, Tip load of 12-30 gm, Soft atraumatic straight tipped, polymer sleeve tip. Moderate rail support, High lubricity, made of stainless steel, Hydrophillic, Length 195-300cm. Dedicated guidewires for crossing calcified lesions or tight lesions 87 or chronic total occlusions. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 457 PERIPHERAL Wire 0.018 Flexible guidewire, Tip load of 4-5 gm, short/long taper, Soft atraumatic straight tipped, spring coil tip. Extrasupport rail support, Moderate lubricity, made of stainless steel, silicon coated, Length 145-260cm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 458 Superficial Femoral Artery Balloon Drug coated balloon for SFA & Fem pop lesions, 0.035 balloon, Diameter from 4mm – 12mm balloon, Lengths from 40 – 150 mm, Carrier molecure : urea . 459 Peripheral Balloon Below the Knee (BTK) Used in Below the knee , 0.014 balloon, OTW balloon, Tapered balloon available in long lengths, Proprietary balloon polymer compounding that enables high flexibility and conformability. 460 Peripheral Compliant / Semi-Compliant Balloon (Monorail) 0.014 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATMDiameter: 1.5 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 461 Peripheral Compliant / Semi-Compliant Balloon (Monorail) 0.018 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATM Diameter: 1.5 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 462 Peripheral Compliant / Semi-Compliant Balloon (Monorail) 0.035 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATM Diameter: 1.5 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 463 Peripheral Compliant / Semi-Compliant Balloon (OTW) 0.014 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATM Diameter: 1.2 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 464 Peripheral Compliant / Semi-Compliant Balloon (OTW) 0.018 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATM Diameter: 1.2 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 465 Peripheral Compliant / Semi-Compliant Balloon (OTW) 0.035 wire compatible, Shaft length: 70 cm to 170 cm, RBP: 8 to 24 ATM Diameter: 1.2 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 88 466 Peripheral Non Compliant Balloon (OTW) 0.018 wire compatible, Shaft length: 40 cm to 150 cm, RBP: 8 to 20 ATM Diameter: 3 to 10 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 467 Peripheral Non Compliant Balloon (OTW) 0.018 wire compatible, Shaft length: 40 cm to 150 cm, RBP: 8 to 20 ATM Diameter: 11 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 468 Peripheral Non Compliant Balloon (OTW) 0.035 wire compatible, Shaft length: 40 cm to 150 cm, RBP: 8 to 20 ATM Diameter: 3 to 10 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 469 Peripheral Non Compliant Balloon (OTW) 0.035 wire compatible, Shaft length: 40 cm to 150 cm, RBP: 8 to 20 ATM Diameter: 11 to 26 mm, Length: 20 to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 470 Peripheral Non Compliant Balloon (OTW) 0.018 wire compatible, Shaft length: 40 cm to 150 cm, RBP > 20 ATM Diameter: 4 to 26 mm, Length: 20 to 200 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 471 Peripheral Non Compliant Balloon (OTW) 0.035 wire compatible, Shaft length: 40 cm to 150 cm, RBP > 20 ATM Diameter: 4 to 26 mm, Length: 20 to 200 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 472 Peripheral Drug Coated / Eluting Balloon Below the knee (OTW), 0.014 or 0.018 wire compatible, Diameter: 1.5 mm to 4 mm, Length: 30 mm to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 473 Peripheral Drug Coated / Eluting Balloon Above the knee (OTW), 0.018 or 0.035 wire compatible, Diameter: 4 mm to 10 mm, Length: 30 mm to 220 mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 474 Peripheral Drug Delivery / Infusion Balloon Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 475 Peripheral Drug Delivery / Infusion Catheter Valved Infusion Catheter 4 or 5 F single-lumen catheter with a proprietary valved tip, which gives the option to infuse without a guidewire in place. It can be used coaxially with wire to maximize treatment area and treat two areas simultaneously below the knee.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 89 476 Balloon in Balloon (BIB) catheter The BIB catheter is designed for controlled and incremental expansion of the CP Stent.. Inner balloon acts as a tool to hold the stent in place while outer balloon is inflated. Four image bands to define the working length of the inner and outer balloon. 12mm30mm balloon diameters. 0.035 guidewire compatibility. 110cm usable length. All Sizes. 477 Peripheral Cutting Balloon (OTW) 0.014 to 0.035 wire compatible, Shaft length: 40 cm to 150 cm. 478 Peripheral Percutaneous Transluminal Angioplasty Balloon PTA balloon, the only nitinol-caged balloon with Controlled Dilatation, was designed for 1:1 vessel sizing to minimize flowlimiting dissections and reduce recoil. As the balloon inflates, the cage causes the balloon to form a series of segmented pillows and grooves along the entire lesion. The pillows apply force to create small dissections that are necessary for effective dilatation. The grooves relieve the stress and stop dissections from propagating.. 479 Peripheral CTO Re-Entry Devices Wire based CTO devices (Re-Entry Devices) for Peripheral - Wire based, All Sizes. 480 Peripheral CTO Re-Entry Devices Needle based CTO devices (Re-Entry Devices) for Peripheral - Needle based, All Sizes. 481 Peripheral CTO Re-Entry Devices Balloon based CTO devices (Re-Entry Devices) for Peripheral - Balloon based, All Sizes. 482 Micro Catheter for small Peripheral vessels Hydrophilic coated, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.0 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 483 Micro Catheter for Peripheral Braided, Hydrophilic coated, soft tip, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 484 Micro Catheter for Peripheral Hydrophilic coated, Kink resistant, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.4 Fr 485 Micro Catheter for Peripheral Braided, Hydrophilic coated, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.5 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 486 Micro Catheter for Peripheral Braided, Hydrophilic coated, soft tip, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.6 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 90 487 Micro Catheter for Peripheral Hydrophilic coated, Kink resistant, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.7 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 488 Micro Catheter for Peripheral Hydrophilic coated, Kink resistant, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.8 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 489 Micro Catheter for Peripheral Braided, Hydrophilic coated, Length: 100-150 cm, Guide wire compatibility: 0.014 - 0.027, Distal outer diameter 2.9 Fr. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 490 PERIPHERAL STENT SELF EXPANDABLE Self-expanding Nitinol peripheral stent 4 mm to 10 mm diameter, Various length of upto ≥120 mm, OTW, 0.035”wire compatibility.. 491 PERIPHERAL STENT SELF EXPANDABLE Self-expanding Nitinol peripheral stent 4 to 7 mm diameter, Various length of upto ≥200 mm, 6F guide compatible and guide wire compatibility of 0.018”.. 492 PERIPHERAL STENT SELF EXPANDABLE Self-expanding Nitinol peripheral stent 4 to 7 mm diameter, Various length of upto ≥200 mm, 6F guide compatible, 0.035” guidewire compatible, OTW.. 493 Peripheral Self Expandable Stent Over The Wire System, Nitinol Stent, Open / Closed cell design, 0.014-0.035 Wire compatible with distal & proximal marker, Selfexpanding with good confirmability & Flexibility, 6 - 8 Fr Sheath Compatible. 494 Peripheral Self Expandable Stent Over The Wire System, Nitinol Stent, Open / Closed cell design, 0.014-0.035 Wire compatible with distal & proximal marker, Selfexpanding with good confirmability & Flexibility, 6 - 12 Fr Sheath Compatible. 495 Peripheral Balloon Mounted Stent - Bare Over The Wire System, Stainless Steel / Cobalt Chromium Stent, Open / Closed cell design, 6 Fr to 10 Fr Sheath Compatible, Wire Diameter: 0.014-0.035 compatible, 2 marker. 496 Peripheral Balloon Mounted Stent - Bare Over The Wire System, Stainless Steel / Cobalt Chromium Stent, Open / Closed cell design, 6Fr to 14 Fr Sheath Compatible, Wire Diameter: 0.014-0.035 compatible, 2 marker. 497 Peripheral Balloon mounted stent which can be over expanded up to the large size balloon more than its original diameter Nitinol / Stainless Steel / Cobalt Chromium Stent, Open / Closed cell design, Wire Diameter: 0.035 Compatible. 91 498 Peripheral Balloon mounted stent which can be over expanded up to the large size balloon more than its original diameter Particular use for Branch PA Stenting Nitinol / Stainless Steel / Cobalt Chromium Stent, Open / Closed cell design, Wire Diameter: 0.014/0.018/0.035 Compatible. 499 Peripheral unmounted bare metal stent Wire Diameter: 0.035 Compatible. 500 Vascular Mimetic Implant Across the Joint Self Expandable, Nitinol / Stainless Steel / Cobalt Chromium Stent, Wire Diameter: 0.014-0.035 wire compatible, 2 marker. 501 Drug eluting stent for Peripheral Artery Disease Self Expandable, 2 markers, Shaft Length: 50-150 Cms, Wire Diameter: 0.014 to 0.035 wire compatible. 502 Peripheral Nitinol / Stainless Steel Self Expandable Covered Stent OTW, Flexible with good conformability with 2 markers (Distal & Proximal), 8Fr to 12Fr Sheath compatibility, Wire Diameter: 0.014 to 0.035 compatible. 503 Peripheral Balloon Mounted Covered Stent (OTW)` Sheath Compatibility: 6 Fr - 12 Fr, Wire Diameter: 0.014 to 0.035 compatible. 504 Peripheral Balloon Mounted Covered Stent (OTW) Sheath Compatibility: 6 Fr - 24 Fr, Wire Diameter: 0.018 or 0.035 compatible. 505 Peripheral unmounted covered stent (OTW) Wire Diameter: 0.035 compatible. 506 Superficial Femoral Artery Stent Self Expanding Nitinol Stent with helical structure for SFA arteries, Available in 5 - 7mm dia in varying length, Triaxial delivery system with thumbwheel for accurate stent deployment with minimum foreshortening. 507 Balloon Mounted Stent graft Balloon Expandable Vascular Covered Stent with stainless steel stent fully covered by ultrathin layers of two e-PTFE Grafts & Covered stent is mounted non- compliant balloon with RX Markets., Available in dia 5mm to 12mm in varying lengths, Micro porous ePTFE: 10- 40 Micron, Catheter working length: 135 cm. 508 Self Expanding Stentgraft Self Expanding Nitinol Stent encapsulated between two ultrathin layers of e PTFE Graft with Carbon coating Inside Grafts, Multifunctional tip-less braided catheter with Stent Loc Mechanism Dia: 5mm to 13.5mm Diameter Lengths: 20mm, 30mm, 40mm, 60mm, 80 mm,100mm, 120mm. 509 Venous Stents Should be self expanding, nitnol based Should be available from 10mm to 20mm diameter in various lengths upto 160mm, Tri axial catheter and dual speed thumbwheel deliver system for smooth and controlled stent deployment. 92 510 Drug Coated Balloon Drug Coated Balloon with 2 μg/mm2 dose of paclitaxel with polysorbate & Sorbitol as Carrier Available in 035 and 014 Platforms 035 guidewire compatible 120cm shaft length for Dia 4mm to 6mm length upto 150cm for SFA / Popliteal arteries 035 with 75cm shaft, Diameter 5-12mm length 60mm For Fistulaplasty cases 014 with shaft 150cm. Diameter 2mm to 3.5 mm lengths upto 120mm for tibial arteries. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 511 Peripheral 035 Balloons Dia from 3mm to 12mm Length 40mm to 300mm. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 512 Large Dia Balloon Ultra non compliant High working pressure range of >5 atm Large diameters 12mm - 26mm in varying lengths. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 513 Carotid Stent 1 Percutaneous Suture 1 2 Superstiff Wire (J Tip) 0.32 X 260 1 3 Long Sheath (8 French) 1 4 Pigtail Catheter 6 French 1 5 Femoral arterial introducer sheath set* 1 6 Three port manifold 1 7 Pressure line 1 8 Power Injector Syringe 1 9 Carotid Stent 1 10 H1 Catheter 1 11 Workhorse wire 1 12 Distal Embolic Protection Device 1 13 ACT Kit + STERILE DRAPE FOR RADIATION PROTECTION DEVICE 2 TOTAL 514 CEREBRAL STENT 515 CAROTID STENT Self-expanding Nitinol carotid stent, monorail, 0.014” Guide wire compatible, tapered end, various length and diameters. . 93 516 CAROTID STENT Self-expanding Nitinol carotid stent, monorail, 0.014” Guide wire compatible, tapered end, Closed cell design in the middle part and open cell design in the edges, various length and diameters. . 517 CAROTID STENT Self-expanding Nitinol carotid stent, monorail, 0.014” Guide wire compatible, cylindrical, various length and diameters.. 518 Carotid Self Expandable Straight Nitinol Stent Monorail System, 2 marker, Wire Diameter: 0.014 Compatible, Design: Closed cell. 519 Carotid Self Expandable Straight Stainless Steel Stent Monorail System, 2 marker, Wire Diameter: 0.014 Compatible, Design: Closed cell. 520 Carotid Self Expandable Straight Nitinol Stent Monorail System, 2 marker, Wire Diameter: 0.014 Compatible, Design: Open cell. 521 Carotid Tapered Nitinol Stent Monorail System, 2 marker, Wire Diameter: 0.014 Compatible, Design: Closed cell. 522 Carotid Tapered Nitinol Stent Monorail System, 2 marker, Wire Diameter: 0.014 Compatible, Design: Open cell. 523 Carotid Distal Embolic Protection Device All Sizes. 524 Near infrared spectroscopy & intravascular imaging catheterUSFDA approved, for detection of lipid core placques and assessment of vessel structure with an automatically adjustablefrequency bandwidth of 35-65 Mhz depending on the need of the calcium with a pullback speed upto 2mm/s and a pullback length of 150mm. catheter working length of 160cm. 525 Pulmonary Thrombus Aspiration System- Complete system comprising of Mechanical thrombectomy catheter (all sizes); seperator; aspiration tubing; aspiration source; canister and other accessories. 526 Support Catheter This catheter is an over-the-wire, single-lumen, seamless catheter with three embedded radiopaque markers, an atraumatic tapered tip, and a 40 cm hydrophilic distal tip coating. It should be designed for high visibility, optimal wire support, and ease of lesion entry for difficult-to-cross lesions.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 527 Angled Support Catheter The catheter is an over-the-wire, single-lumen, seamless catheter with three embedded radiopaque markers, an atraumatic tapered tip, and a 40 cm hydrophilic distal tip coating. It should be designed for high visibility, optimal wire support, and ease of lesion entry for difficult-to-cross lesions.. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. 94 528 DISTAL EMBOLIC PROTECTION DEVICE Filter type Rapid Exchange Cerebral protection device compatible with 0.014” wire, 4-8 mm diameter.. 529 DISTAL EMBOLIC PROTECTION DEVICE Basket type Rapid Exchange Cerebral protection device compatible with 0.014” wire, 4-8 mm diameter.. 530 DISTAL EMBOLIC PROTECTION DEVICE Myocardial Embolic Protection device for SVG. 3-7mm diameter.. 531 Thrombectomy Catheter set for Small vessel (≥ 1.5mm vessel) Sheath Compatibility: 4 Fr, Guide Compatibility: 6 Fr, Wire Compatibility: 0.014, All Sizes. . 532 Thrombectomy Catheter set for Pulmonary artery Sheath Compatibility: 6 Fr, Guide Compatibility: 8 Fr, Wire Compatibility: 0.035, All Sizes. . 533 Thrombectomy Catheter set for DVT in lower limb veins Sheath Compatibility: 8 Fr, Guide Compatibility: 10 Fr, Wire Compatibility: 0.035, All Sizes. 534 Thrombestomy Support Catheter Supporting connector for Thrombectomy Catheter (SN. O.9, O.10, O.11). 535 Support Catheter 0.014 wire Compatible, All Sizes. 536 Support Catheter 0.018 wire Compatible, All Sizes. 537 Support Catheter 0.035 wire Compatible, All Sizes. 538 Sheathless Guide All Sizes. 539 VARICOSE VEIN ABLATION Radiofrequency ablation. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 540 Atrial Septostomy Blade All Sizes. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 541 Balloon Atrial Septostomy Catheter All Sizes. Clinically used for minimum 10 years . Detailed data for pyrogenicity and shelf life should be provided. 542 STEERABLE GUIDE CATHETER Atraumatic access to areas of the vasculature that are otherwise difficult to access, using steerable guide catheters constructed with components that are selected to provide optimal navigability, torque transfer, true bi-directional tip deflections of 180˚and push ability for a variety of typical percutaneous access routes. The catheter wall thickness in the deflecting segment of the guide catheter should be about 1 French (⅓ mm) or less, and includes a slotted deflection tube, and allows a very tight turning radius which in turn enables guide catheter access to regions of the vasculature that are otherwise 95 inaccessible. 8.5F 543 STEERABLE GUIDE CATHETER Atraumatic access to areas of the vasculature that are otherwise difficult to access, using steerable guide catheters constructed with components that are selected to provide optimal navigability, torque transfer, true bi-directional tip deflections of 180˚and push ability for a variety of typical percutaneous access routes. The catheter wall thickness in the deflecting segment of the guide catheter should be about 1 French (⅓ mm) or less, and includes a slotted deflection tube, and allows a very tight turning radius which in turn enables guide catheter access to regions of the vasculature that are otherwise inaccessible. 10 F 544 STEERABLE GUIDE CATHETER Atraumatic access to areas of the vasculature that are otherwise difficult to access, using steerable guide catheters constructed with components that are selected to provide optimal navigability, torque transfer, true bi-directional tip deflections of 180˚and push ability for a variety of typical percutaneous access routes. The catheter wall thickness in the deflecting segment of the guide catheter should be about 1 French (⅓ mm) or less, and includes a slotted deflection tube, and allows a very tight turning radius which in turn enables guide catheter access to regions of the vasculature that are otherwise inaccessible. 12 F 545 Steerable Introducer Steerable introducer is designed to replace a fixed curve introducer. Dual-Reach bi-directional 180˚/90˚ deflection allowing asymmetric deflection — for more mobility with less shaft torque. Curl options include small (16.8 mm), medium (22.4 mm) and large (50.0 mm). Auto-lock capability is designed to reduce curve movements during complex procedures. Braided shaft provides exceptional torquability, pushability and kink resistance. Radiopaque tip marker enhances fluoro visibility. Hhemostasis valve provides effective hemostasis, and seals down to a 0.014 inch guidewire. Accommodates a 98 cm transseptal needle and transseptal needle. Ergonomic handle provides user comfort. 546 Guiding Catheter 1 Extra backup (EBU) 2 XBU 3 Voda left & CLS Curve 4 LCR 5 Hockey Stick 6 Leya Catheter 547 Guide wire 1 Sion Blue 2 Sion Black 96 3 Gaia First 4 Gaia Second 5 Gaia Third 6 Whisper MS 7 Pilot 150 8 Pilot 200 9 Fielder FC 10 Fielder XT 11 Fielder XTR 12 Fielder XTA 13 Cross wire NT 14 Choice PT 15 PT Graphix 16 Cross IT 100 17 Cross IT 200 18 Cross IT 300 19 Cross IT 400 20 Miracle Brothers 3.0 21 Miracle Brothers 4.5 22 Miracle Brothers 6.0 23 Miracle Brothers 12.0 24 Conquest 9 25 Conquest 12 26 Conquest Pro 9 27 Conquest Pro 12 28 Conquest Pro 8 -12 29 RG 3 30 GAIA NEXT 548 Sheath less guiding catheter system 1 Railway - Cordis 2 Eaucath - Asahi 549 Guide Extension Catheter 1 Heart rail 2 Guide liner 3 Guide zilla 4 Telescope 5 Guide Plus 6 Trap liner 550 Peripheral vascular sheath 1 Glide slide slender (Terumo) 551 Micro catheter 1 Fine Cross 2 Sting Ray- OTW 3 Cross Boss 4 Corsair 5 Dual lumen catheter 97 552 CTO Balloon 1 Across CTO Balloon 2 NIC nano 3 Clear line CTO balloon 4 Mozee 5 Alvevo HP 0.75mm CTO balloon 553 Guide Wire 1 Suoh 3 2 RBSO (Telefax) 554 Micro Catheter - Single Lumen 1 Fine Cross MG 2 Caravel 3 Tornus 4 Corsair 5 Super cross 6 Corsair Pro 7 Turopilee 8 Mamba flex 9 Teleport 10 Micro Cross 11 Mcath 12 TORNUS Micro Catheter 13 Bridge point CTO System 555 Microcatheter Dual lumen 1 Twin pass 2 Sasuke 3 Crusade 4 NH aneer Rx 5 Fineduo 6 Re Cross 556 Angulated tip microcatheter 1 45º degree 2 90º degree 3 120º degree 557 Steerable Angulated tip microcatheter 1 Swift Ninja 2 Venture Deflectable catheter 558 Radial sheath with a thin wall structure where the outside diameter is reduced by one French size while the inner diameter equivalent is maintained; 5,6,7 Fr sheaths 559 Guide catheter for CTO cases with guidewire port, torque device lock, ratcheting torque device, working length 135cm. 560 self orienting, flat balloon that automatically positions one exit port towards true lumen with Hydrophillic coating on the balloon shaft. Guidewire shaft diameter o.o14, angled tip. Cathter with guidewire port and balloon inflation port, working length 135 cm. 98 561 Bioabsorbable Vascular Closure Device- composed of an absorbable collagen sponge and absorbable polymer anchor that are connected by an absorbable self-tightening suture (STS). The device should seal and sandwich the arteriotomy between its two primary members, the anchor and collagen sponge. . 562 Guidewire with ICE hydrophilic coating, supportive Scitanium™ stainless steel core, tip design- 35 cm polymer sleeve,3,6,8 g tip load 563 Guidewire with Supportive .035 wire, Core-to-tip design,Hydrophobic coating, available in guide wire lengths of 145 cm, 190 cm and 300 cm 564 Hybrid Cobalt-Chromium Abluminal Biodegradable Polymer with Biolimus A9 Drug Eluting Stent having Mid Section S-Shape connectors & Thin strut cobalt chromium (assorted sizes) 565 Polymer and carrier free Drug Coated Stent with Biolimus A9 (BA9) & micro-structured abluminal surface, having Lower peak force for better tracebility, Higher pushability & Large cell opening diameter (assorted sizes) 566 Guide Extension System Kit with FLEX ZONE and Unique 3 Zone Transition for smooth trackability and highest coiling density for extra pushability 567 INJ. TENECTEPLASE 40MG 568 INJ. TENECTEPLASE 20MG 569 INJ. STREPTOKINASE 1.5 MILLION IU 570 INJ. EVOLOCUMAB 140MG 571 INJ. INCLISIRAN 284MG 572 INJ. PROCAINAMIDE HYDROCHLORIDE 1G/10ML 573 INJ. TIROFIBAN 5MG/100ML 574 INJ. CANGRELOR 50MG 575 INJ. SELEXIPAG 18000 MCG 576 TAB. MACITENTAN 10MG 577 CAP. MAVACAMTEN 2.5MG 578 TAB. BEMPEDOIC ACID 180MG 579 TAB. TAFAMIDIS 61MG 580 CAP. MEXILETINE HYDROCLORIDE 150MG 581 RADIAL CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 1 Guiding Catheter 1 2 Diagnostic Catheter 2 3 Drug eluting stent (Sirolimus) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 2 7 Hydrophillic wire J tip* 0.32-0.38 2 8 Radial arterial introducer sheath set 6F 2 99 9 Three port manifold 2 10 Pressure line 150cm 4 11 Y connector 1 12 Long tube to connect Y Connector to manifold 1 13 Inflation device 1 14 TR Band 1 15 Syringe – 20 ml luer lock 1 16 Syringe – 10 ml luer lock 3 17 ACT Kit 2 18 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 582 FEMORAL CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 1 Guiding Catheter 1 2 Diagnostic Catheter 2 3 Drug eluting stent (Sirolimus) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 2 7 Guide wire J tip* 0.32 - 0.38 2 8 Femoral arterial introducer sheath set 7F 1 9 Radial arterial introducer sheath set 6F 1 10 Three port manifold 2 11 Pressure line 150cm 4 12 Y connector 1 13 Long tube to connect Y Connector to manifold 1 14 Inflation device 1 15 Hemostatic Device 1 16 Syringe – 20 ml luer lock 1 17 ACT Kit 2 18 Syringe – 10 ml luer lock 3 19 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 583 RADIAL 1 Guiding Catheter 1 100 CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 2 Diagnostic Catheter 2 3 Drug eluting stent (Paclitaxel) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 2 7 Hydrophillic wire J tip* 0.32 -0.38 2 8 Radial arterial introducer sheath set 6F 2 9 Three port manifold 2 10 Pressure line 150cm 4 11 Y connector 1 12 Long tube to connect Y Connector to manifold 1 13 Inflation device 1 14 TR Band 1 15 Syringe – 20 ml luer lock 1 16 Syringe – 10 ml luer lock 3 17 ACT Kit 2 18 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 584 FEMORAL CORONARY ANGIOPLASTY(PTC A) WITH (SINGLE) DRUG ELUTING STENT (DES) 1 Guiding Catheter 1 2 Diagnostic Catheter 2 3 Drug eluting stent (Paclitaxel) 1 4 Balloon Catheter Non Compliant* 1 5 Balloon Catheter Semi Compliant* 1 6 PTCA Wire 2 7 Guide wire J tip* 0.32 - 0.38 2 8 Femoral arterial introducer sheath set 7F 1 9 Radial arterial introducer sheath set 6F 1 10 Three port manifold 2 11 Pressure line 150cm 4 12 Y connector 1 13 Long tube to connect Y Connector to manifold 1 101 14 Inflation device 1 15 Hemostatic Device 1 16 Syringe – 20 ml luer lock 1 17 ACT Kit 2 18 Syringe – 10 ml luer lock 3 19 STERILE DRAPE FOR RADIATION PROTECTION SYSTEM 1 TOTAL 585 A drug-eluting balloon (DEB) featuring a three-layer matrix for sustained drug release, primarily paclitaxel, at the treatment site. It is designed for use in various vascular territories, both arterial and venous, peripheral and central, including supra-aortic areas. Paclitaxel is the active substance, coated on the balloon surface at a dosage of 2.2 µg/mm², with dextran (0.7 µg/mm²) as an excipient to support drug uptake. Matrix: The balloon features a three-layer matrix: an elastic base to adhere paclitaxel to the balloon, a drug layer of paclitaxel crystals, and an outer layer of dextran for protection during delivery. Balloon Material:The balloon is made of a semi-compliant material, likely Pebax/Nylon, and can be coated on different catheter platform