Construction Of Minor Bridge On S.H.-282 To Ramgaon Dhamangaon Chavsala Road At Ch:-5/200 Tq:- Darwha Dist:- Yavatmal Under Package No Adb-Yav(Ii)-Br-04
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Oct 2025
0 days left
EMD
1.79 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
darwha → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction of Minor Bridge on S.H.-282 to Ramgaon Dhamangaon Chavsala Road at ch:-5/200 Tq:- Darwha Dist:- Yavatmal Under Package No ADB-YAV(II)-BR-04
BOQ
| Sl. No. | Item Description |
| 1 | Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.( Rate as per S.O.R. It No. 2.2 (II) A ) Page No.-----) |
| 2 | Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.By Mechanical Means ( Rate as per S.O.R. It No. 2.5 II ( A ) Page No.-----) A)PlainCement Conc |
| 3 | Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. B)Reinforced Cement Conc ( Rate as per S.O.R. It No. 2.5 (II) B )Page No .-----) |
| 4 | Removing all types of Hume pipes Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. (C) Above 900 mm dia Hume pipe( Rate as per S.O.R. It No. 2.13C ) Page No.-) |
| 5 | Excavation for Structures Earthwork Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil4A) Upto 3 m depth ( Rate as per S.O.R. It No. 11.1 I )i ) Page No.-----) |
| 6 | Excavation for Structures Earthwork Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary rock (not requiring blasting)Upto 3 m depth [Rate as per S.O.R. It No. 11.1 (II) Page No.-----] |
| 7 | Excavation for Structures Earthwork Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.Hard rock ( Blasting Prohibited)Upto 3 m depth[ Rate as per S.O.R. Item no. 11.1 IVPage No.-----] |
| 8 | Dewatering Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) Rate as PerP.W.SSR.22-23 Sr No. 417 |
| 9 | Providing selected hard murum filling including laying in layers of 15 to 20cmwith watering and compacting etc. complete.I)MurumFilling (RATE AS PER P.W.S.S.R.2022-23 Item no. 11.24 Sr no.399) |
| 10 | Providing concrete for plain/reinforced concrete Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15Nominal Mix 1:2.5:5 [[RATE AS PER S.O.R Item no. 11.4 II ( i ) Page No.-----] |
| 11 | Filling annular Filling annular space around footing in rock as per technical specification Clause 1203.4.3.P.C.C grade M 15[RATE AS PER S.O.R. Item no. 11.3Page No.-----] |
| 12 | Providing and laying filter media Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 [RATE AS PER S.O.R. Item no. 12.11Page No.-----] |
| 13 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C grade M 25Abutment Bed Block [RATE AS PER S.O.R. Item no. 11.4 III (iii)Page No.-----] |
| 14 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203R.C.C grade M 30PierBed Block [RATE AS PER S.O.R. Item no. 11.4 VIPage No.-----] |
| 15 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 [RATE AS PER S.O.R. Item no. 12.5 II .(iii) Page No.-----] [ P.C.C grade M 25 ] |
| 16 | For Substructure[ R.C.C grade M 30 ] For Pier Reinforced cement concrete of M30 Grade in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(Excluding reinforcement) RATE AS PER SORIt No.12.15)Page no ------------ |
| 17 | Abutment , Pier Cap &SLAB Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 M30 RATE AS PER S.O.R13.1)III Page No.-----) |
| 18 | STEEL ( Foundation) Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 (RATE AS PERMRRDA S.O.R 23-24 It No.11.7) |
| 19 | STEEL ( Sub Structure ) Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (RATE AS PER MRRDA S.O.R 23-24 It No.12.6) |
| 20 | STEEL ( Super Structure ) Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (RATE AS PERMRRDA S.O.R 23-24 It No.13.2) |
| 21 | Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete.. (RATE AS PER P.W.SSR.22-23 Sr No. 471) |
| 22 | TAR PAPER BEARING Providing tar paper bearing including laying in proper position etc. complete. (Rate as PerP.W.SSR.22-23 Sr No. 450) |
| 23 | FLEXIBLE STONE MAT Providingand laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. [RATE AS PER S.O.R. 13.28Page No.---------] |
| 24 | WEEP HOLES Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7[RATE AS PER S.O.R12.9 Page No.-----] |
| 25 | WEARING COAT Providing and laying cement concrete wearing course M 30 grade including reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3M30 [RATE AS PER S.O.R 13.5 Page No.-----] |
| 26 | Providing and fixing in position pipe Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 (RATE AS PER S.O.R13.8 Page No.-----) |
| 27 | Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701(RATE AS PER S.O.R It No. 10.5 Page No.-----) |
| 28 | Gabion Stracture Providing & fixing G.I. wire Gabions coated with Zinc+PVC of required size, section including boxes made of mechanicallyhexagonal shaped double twisted steel woven as per ASTM A975-9wire mesh 10x12cm. edges mechanically selvedged made of heavily (Zinc+ PVC) coated G.I. wires as per BS: 443, mesh wire 3.00 mm Ø edge wire 3.9 mm Ø and filled with 20 to 50 kilogram weight trap stones including conveying with all the leads & lifts and placing at required places in required line, level, slope as per drawing, section as directed etc.complete. (Size- 2m X 1m X 1m)RATE AS PER S.O.R It No. 14.19Pg No.-------- |
| 29 | Pitching Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302Stone / Boulder [RATE AS PER S.O.R. It No. 14.5 I) Page No.-----] |
| 30 | Excavation in SoilwithDozer with lead upto 100 mExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections [RATE AS PER S.O.R. Item No. 3.5 ( ii ) Page No.----- ] |
| 31 | Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 [RATE AS PER S.O.R. Item No. 3.3 Page No.-----] |
| 32 | Construction of Embankment with Material Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto1000m as per Technical Specification Clause 301.5 [RATE AS PER S.O.R. Item No. 3.4 Page No.-----] |
| 33 | Granular Sub-base Granular Sub-base with Well Graded Material (Table 400.1)(A)By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. [RATE AS PER S.O.R. Item No. 4.1 A) ii) Page No.-----] |
| 34 | Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with vibratory roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.[RATE AS PER S.O.R. Item No. 4.9 Page No.-----] |
| 35 | Dry lean cement concrete Sub- base Construction of dry lean cement concrete Sub- base over aprepared sub-gradewith coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved byEngineer-in-charge , compacting withvibratory roller, finishing,curing andincluding preparation of sub-grade surface if required etc. complete.with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. [Spec.No. :-As perSOR-2023 -24 Item no. 6.9Page No.--- ] |
| 36 | White Topping plain cement concrete pavement Providing and laying White Topping as per IRC-SP 76-2015 over bituminous surface (Existing bituminous surface preparation to be done if necessary either by milling or levelling course with BM/DLC to correct surface profile and to be paid separately) with unreinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement (OPC 43/OPC 53-Grade) at 357kg/cum and 105 kgs of Fly Ash (Replacement of Fly Ash to the extent of 15% and Fine aggregate by 10%) coarse aggregate, fine aggregate and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fibre as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fibre at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with mechanical paver finisher, spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m to a depth of 1/3 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, sealing joints labour and HOM of machineries etc. complete as per specifications. [Spec.No. :-As perSOR-2023 -24 Item no. 6.8Page No.--- ] |
| 37 | Providing and fixing in position, 25mm dia dowel bars Providing and fixing in position, 25mm dia anticorrosive MS dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30. 00 cm. C/C and wherever directedincluding handling, straightening, necessary cutting supported by, chairs with proper alignment with half length withcovered by polythin Sheathering including Cap etc. complete. [Spec.No. :-As perSOR-Item no. 6.10Page No.-.. ] |
| 38 | Providing and fixing in position 12 MM ,diaTie bars Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/Cand wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. [Spec.No. :-As per SOR-2023-24Item no. 6.11Page No.--- ] |
| 39 | Construction of Subgrade andEarthenShoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. [RATE AS PER S.O.R. Item No. 3.14Page No.-----] |
| 40 | Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 1000mm dia[RATE AS PER P.W. S.S.R.2022-23Item No. 11.12 |
| 41 | Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete450x450x600 mm, 600 mm below ground level as per approved drawing Clause1701.2.2 A) i) 900 mm equilateral triangle (RATE AS PERMRRDA S.O.R 23-24 It No.10.2B ) |
| 42 | Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete450x450x600 mm, 600 mm below ground level as per approved drawing Clause1701.2.2B) ii)600 mm x 450 mm rectangular SOR item no. 10.2 BPage No.:- - |
| 43 | Providing and Fixing \"Logo\" of PMGSY Project Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of TwoPlates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plateswill be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (RATE AS PER CSRI.No.10.16 Page No.-----) |
| 44 | Citizen Information Board MMGSY / PMGSY Citizen\" s information Board- Providing and fixing of typicalPMGSY Retro Reflective information board as peras per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottomduly rivetted with MSangles of 35 x 35x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.[RATE AS PER S.O.R.-2020-21 Item No. 10.24Page no--------] |
| 45 | Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 [RATE AS PER S.O.R. Item No. 10.11Page No.-----] |
| 46 | Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702. [RATE AS PER S.O.R. Item No. 10.8 Page No.-----] |
| 47 | Road Delinators(Hazard markers) Road Delineators:Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings. (Rate as Per P.W. SSR 22-23 Sr No.219) |
| 48 | Painting Trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete. (Rate as Per P.W. SSR 22-23 Sr No.207) |
| 49 | Fluorescent tape Providing and fixing reflective fluorescent tape on old road sign board by following the procedure recommanded by manufacturer.Tape shall be consist of white or coloured sheeting having smooth outer surface which has the property of retro-reflection over its entire surface.It shall be weather resistant and show colour fastness.It shall be new and unused and shall show no evidance of cracking,scaling,pitting,blisting,edge lifting and shall have negligible shrinkage or expansion including cleaning / scraping and painting of existing board etc. complete. (Guidance on the recommanded application of each class of tape may be taken from IRC-67) [Rate as Per P.W. SSR 22-23 Sr No.214] |
| 50 | Thermoplastic Compound Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). [RATE AS PER S.O.R. Item No. 10.21Pg No.-----------] |
| 51 | Hazard Marker ( Steel pipe delineators ) Providing and fixing steel pipe delineators of 10 cm. in diameter and total height of 130 cm, provided with 2 strips of white retroreflective sheeting of size 5 cm. x 32.5 cm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 5 cm. x 32.5 cm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 25 cm. x 25 cm. x 45 cm. with necessary excavation etc. complete. [RATE AS PER S.O.R. Item No. 6.16Pg No…..] |
| 52 | Raised Pavement Marker/ Cat Eyes Supplying andFixing of Molded Shank RaisedPavement Markers / Cat\"s Eyemade of polycarbonate and ABSmouldedbodyandreflectivepanelswithmicroprismaticlenscapableofprovidingtotalinternal reflectionofthelightenteringthelensfaceandshallsupportaloadof16000kg testedinaccordanceto ASTM D 4280 TypeH and complyingtoSpecificationsofCategoryA ofMORTH CircularNo RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submitatwoyearwarranty forsatisfactoryfieldperformanceincludingstipulatedretro-reflectanceofthe reflecting panel, to the Engineer.[RATE AS PER S.O.R. Item No. 6.09Sr No.215] |
AI Tender Summary
Tender Timeline
Oct 06, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedOct 24, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 27, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender