Tender For Kulpahar Nagar Panchayat Reorganization Water Supply Scheme Distt.Mahoba Under Amrut 2.0 - CIVIL WORKS 2 WTP works 3 Survey, Investigation, Soil Testing, Planning, Design and Drawing construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevant latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be Vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractors cost. For construction of 9 MLD WTP on latest technology ., Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant with leak detection and absorption system (Cooling tower type), chlorine safty kit with tools, Development of WTP area with plantation, Rainwater harvesting unit andwith centraly located adequate LED light of 200 Watt High mask (12 M Hight, 8 nos LED) . Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Engineer/IS code.Collapsible MS steel doors and aluminum windows to be provided including of three-coat whitewashing, internal two coat snowcem painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrificationincluding automation, instrumentation & SCADA, wireless telemetry (voice & data), including Water Testing Kits, Lab Building and essential lab equipment as mentioned in the related Items Including of supply of all materials, labor T&P etc required for proper completion of works as per direction of the Engineer. All works complete as per design and drawing approved by engineer incharge. contractor will have to provide four wheelers, two wheelers, with fuel & driver for supervision of work and computer/laptop with operator as mentioned in tender document. 4 INTAKE WELL WORKS 5 Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractors cost.For construction of Intake Well of minimum internal size of 10.00M Dia & 20.00 M Height with required foot bridge, water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 20.00, Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item. 6 Intake well cum pump house 10.0 m internal dia meter 4.50 m height above floor level, the depth of pump 5.0m below lowest water level and total height of intake well 20.0m from bed level of intake well to floor level of pump house the intake well shall firmly base onsuitable foundation in i.e.d raft foundation as per design requirements construction of RCC balcony or floor level, the pump house shall consisting of RCC column & bricks masonry walls. Construction of RCC Channel up to intake well in required size/length as per design for smooth raw water intake in summer days. Supply and fixing as door & windows, supplying and fixing ISMB350, chain piling blocks, supply and fixing CI D/F SV & etc. , supply and fixing GI pipe railing 20mm dia seperated on 65x65x6mm MS angles 1.50m C/C either wide as site core & other fase of balcony,construciton of floor of pump house using coata stone painting of doors and windows and all concrete cement using approved paint 3 coats with 80 M long and 3.5 M wide foot over bridge as per approved design and drawings. All works complete as per design and drawing approved by engineer incharge 7 Rising Main & By Pass arrangement 8 Supply of the following size pipes including railway freight, insurance charges F.O.R. etc. complete. 9 350 mm dia D.I. Class K-9 10 250 mm dia D.I. Class K-9 11 150 mm dia D.I. Class K-9 12 Supply of Specials for above pipe F.O.R destination including all Taxes and insurance. 13 Carting, laying and jointing of the following sizes of pipes into the trenches including cost of all jointing materials, labour and T&P, testing etc. complete. All works complete as per design and drawing approved by engineer incharge 14 350 mm dia 15 250 mm dia 16 150 mm dia 17 Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches. 18 From Intake Well to WTP 19 Ordinary soil 20 Ordinary rock (mixed with kankar) 21 Hard rock (requiring blasting) 22 Hard rock (blasting prohibited) 23 Supply of following sizes of C.I. D/F sluice valves as per I.S. 780- 1960 tested to 10 Kg/sqm fixing in pipe line trenches, jointing and testing complete. 24 350 mm dia 25 250 mm dia 26 150 mm dia 27 Supply of C.I. Air valve 28 20 mm 29 Carting of D/F sluice valves of following sizes to the site of works lowering them into already prepared trenches and fixing them in position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc.complete excluding values and specials required but including the testing etc. complete. 30 350 mm dia 31 250 mm dia 32 150 mm dia 33 Air Valve 34 20 mm 35 Supply of all materials, labour, T&P and construction of following chambers as per type design including supply and materials, labour and T&P, testing etc. complete. 36 Masonry Type 37 Air Valve chamber 38 Provision of Thrust block 39 350 mm dia 40 250 mm dia 41 150 mm dia 42 Dismantling and reinstatement of following type of road surfaces for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials. The firm must obtain permission from the relevant department for road cutting to lay the pipeline. onlycorrespondence will be done by the department . 43 C.C. Road 44 Crossing of Culvert/ Nala for laying pipe line including supply and materials labour, T&P etc. complete. 45 3.5M to 7.0M 46 Nahar Crossing (20M) 47 Crossing of road for laying pipe line including supply and materials labour, T&P etc complete. 48 Crossing of culvert/nala for laying pipe line including supply and materials labour, T&P etc complete. 49 Charges payable to PWD for permission of crossing Roads. 50 Charges payable to Forest Department for permission ofcrossing Roads. 51 Distribution System 52 Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches anddisposal of surplus earth up to 50 m from the center of the foundation trenches. 53 Ordinary rock (mixed with kankar) 54 Hard rock (blasting prohibited) 55 Supply of the following sizes of pipes confirming to I.S. 4984:1995, I.S.-8329/2000 latest relevant of I.S.S. with couplers etc complete in all respect F.O.R. destination including all taxes and insurance. 56 HDPE Pipe PN-10 (O. D.) PE-100 57 110 mm dia 58 140 mm dia 59 160 mm dia 60 Supply of Specials for above pipe F.O.R destination including all Taxes and insurance. 61 HDPE Pipe PN-10 (O. D.) PE-100 62 DI Pipe K-7 63 200 mm dia 64 250 mm dia 65 300 mm dia 66 350 mm dia 67 400 mm dia 68 Addition (DI K-7) Pipe for connecting overflow to main supply 69 400 mm dia 70 Addition (DI K-7) Pipe for connecting overflow to main supply 71 350 mm dia 72 Supply of Specials for above pipe F.O.R destination including all Taxes and insurance. 73 DI Pipe K-7 74 Carting from the store (up to 8 Km.) The following sizes of pipe and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. complate but excluding cost of trenching and cutting of pipes etc. Formaking of lengths but including making joints. All works complete as per design and drawing approved by engineer incharge 75 HDPE Pipe PN-10 (O. D.) PE-100 76 110 mm dia 77 140 mm dia 78 160 mm dia 79 DI Pipe K-7 80 200 mm dia 81 250 mm dia 82 300 mm dia 83 350 mm dia 84 400 mm dia 85 Addition (DI K-7) Pipe for connecting overflow to main supply 86 400 mm dia 87 Addition (DI K-7) Pipe for connecting overflow to main supply 88 350 mm dia 89 Supply of following types of fittings including railways freight,cartage up to store, all taxes and duties complete. 90 C.I. Double flanged Sluice /Scour Valves as per I.S. 780/1969 class-1 working pressure 10 Kg/sqm F.O.R Destination including all taxes and insurance. 91 C.I. Double flanged Sluice Valves 92 100 mm 93 125 mm 94 150 mm 95 200 mm 96 250 mm 97 Scour Valves 98 80 mm dia 99 Air Valves 100 25 mm 101 Fire Hydrants 102 80 mm 103 Carting of following fittings of following sizes to the site of works lowering them into already prepared trenches and fixing them in position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testingetc. complete excluding values and specials required but including the testing etc. complete. 104 C.I. Double flanged Sluice Valves 105 100 mm 106 125 mm 107 150 mm 108 200 mm 109 250 mm 110 Scour Valves 111 80 mm dia 112 Air Valves 113 25 mm 114 Fire Hydrants 115 80 mm 116 Supply construction of following chambers as per type design including supply and materials labour, T&P etc. complete. 117 Masonry Type 118 Air Valves 119 Fire Hydrants 120 Dismantling of following type of surface including sorting out and staking of serviceable materials and disposal of unserviceable material up to a distance of 50m. The firm must obtain permission from the relevant department for road cutting to lay the pipeline. onlycorrespondence will be done by the department . 121 B.O.E. ROAD 60% old bricks 122 Bituminous Road 123 CC Road 124 Inter locking Road 125 Reinstatment of following type of road including supply of all material, labour etc complete. All works complete as per design and drawing approved by engineer incharge 126 B.O.E. ROAD 60% old bricks 127 Bituminous Road 128 CC Road 129 Inter locking Road 130 Crossing of Culvert upto 3.5M for laying pipe line includingsupply and materials labour, T&P etc. complete. 131 Crossing of Culvert 3.5M to 7.0M for laying pipe line including supply and materials labour, T&P etc. complete. 132 Crossing of Road for laying pipe line including supply and materials labour, T&P etc. complete. 133 3.5 M wide Road 134 7.00 M wide Road 135 Charges payable to PWD for permission of crossing Roads. 136 House connection on New Pipeline 137 Provision of House connection including Supply of all materials, labours T&P etc required for proper completion of work. (as following) 138 Making House Connection with distribution main including dismantling of road, supply, carting of specials, Lowering them into trances, fixing them in proper alignment and jointing including bailing out to water, necessary excavation for connection including all labour, T&P etc. required for propercompletion of the work. All works complete as per design and drawing approved by engineer incharge 139 In B.O.E. Roads 140 For 90 mm to 110 mm dia 141 For 140 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 250 mm to 300 mm dia 144 In Bituminous Road 145 For 90 mm to 110 mm dia 146 For 140 mm to 160 mm dia 147 For 200 mm to 250 mm dia 148 For 250 mm to 300 mm dia 149 For 350 mm to 500 mm dia 150 In C. C. Roads 151 For 90 mm to 110 mm dia 152 For 140 mm to 160 mm dia 153 For 200 mm to 250 mm dia 154 For 250 mm to 300 mm dia 155 For 350 mm to 500 mm dia 156 In C. C. Interlocking tiles Roads 157 For 90 mm to 110 mm dia 158 For 140 mm to 160 mm dia 159 For 200 mm to 250 mm dia 160 For 250 mm to 300 mm dia 161 For 350 mm to 500 mm dia 162 In Earthen Roads 163 For 90 mm to 110 mm dia 164 For 140 mm to 160 mm dia 165 For 200 mm to 250 mm dia 166 For 250 mm to 300 mm dia 167 RCC MCWR Cum Pump House 168 Supply of all materials, labour and T&P etc. complete for the construction of Ground RCC MCWR of 700 KL capacity & with 1.00m wide P.C.C. appron alround with 6 cm semi circular P.C.C. drain M.S. ladder with hand rails out side and inside the tank body proper ventilators at top, water level indicator, Lightening conductor as per latest I.S.I. or electricity rules, 1150mm dia medium pattern C.I. Manhole cover hinged with locking arrangement fixing and jointing vertical DID/F, pipes, specials and duck foot bends of required size for inlet, outlet fising of outlet sluice valve and wash out sluice valves with all jointing materials for proper completion and other appurtenant works including excavation in all type of soil & in rock etc. painting on exposed water proof cement paint, painting of pipes and ladder with approved anticorrosive paints also including testing of the CWR including carriage of construction materials by truck/ head load etc. upto site of work & also.. 169 Supply of following size of DI D/F (K-7) (K-9) pipes conforming to IS8329/2000 or its latest amendment upto rail head including all taxes, duties insurance charges etc. 170 Inlet pipe 350 mm dia 171 Outlet pipe 350 mm dia 172 Over flow pipe 350 mm dia 173 Wash out pipe 100 mm dia 174 Carting of above size of DI K-7 and K-9 pipes upto site of work and lowering them into the trenches and laying true alignment and gradientand jointing of pipes complete (including testing of pipe lines and cutting of pipes for making up the length excluding the cost of trenches). 175 Inlet pipe 350 mm dia 176 Outlet pipe 350 mm dia 177 Over flow pipe 350 mm dia 178 Wash out pipe 100 mm dia 179 Supply of following dia ISI Mark sluice valve conforming to IS 780/1984 or its latest amendment of standard make (Kirloskar or IVC Make) including all taxes etc. and carting, loading and unloading upto departmental store. 180 100 mm dia (in wash out pipe) 181 Carting of following fittings/ sepicels to the site of work, lowering them into trenches, fising in position and jointing them with pipe lines and testing etc. complete (including supply of all jointing materials). 182 Sluice valves/ gate valves of 10 kg/cm2 working pressure 183 100 mm dia (in wash out pipe) 184 Supply of all materials, labour T&P etc all complete to construct sluice valve chamber of following sizes. Sluice valve chambers for 300 mm dia Sluice valve at outlet pipe. 185 Provide all materials, labours, T&P and construction over flow chambers as per departmental drawing or as directed by the Engineer. 186 Same as above but for wash out chambers. 187 Provision for the disposal of over flow water & wash out water from chambers to nearest suitable point of disposal including supply of pipes,its laying jointing excavation and protection work at the point of disposal. 188 PUMP HOUSE : 189 Supply of all materials labour T&P etc. for the complete construction of RCC Framed pump house adjacent to CWR as per approved design, drawing and standard specifications with 1 n wide PCC appron around along with 15cm semicircular PCC drains, RCC wall upto plinth level, to roof of pump house, laying case PCC 1:4:8, RCC floor, foundation and roof, 2m wide RCC plateform at plinth level, stair case from plateform to floor of pump house railing on the stair case and plateform foundation block of pumping plant RCC columns with bracket and longitudinal RCC beams to support moving gantry crane, plastering in the inner and outer brick masonary wall, flooring supply and fixing of doors, windows ventilators, painting on explosed surface with three coats of approved water proof cement paint, white washing in the inner surface, painting of door, windows ventilators, etc. supply and fixing of CI down pipes from roof to GL and other appurtenants works required to complete thepump house in all respect. 190 Capacity of MCWR 700 KL 191 Provision for soil testing 192 RCC OHT Zone-II 193 Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, includingcost of soil testing and based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S.2911. 194 1000 KL with 22 m Staging 195 All components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456 196 Minimum depth of foundation below original ground level will be 2.0 197 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. 198 The assumed bearing capacity of soil has been taken as 8 M.T. sqm 199 1 m wide RCC stair case from ground level to balcony. 200 M.S. ladder made of 50 x 50 x 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to be top dome resting on an RCC plateform (75 x 75 cm and 10 cm thick) projecting from top ring beam and one alluminimum ladder inside thw tank body (from manhole in top dome to bootom dome). 201 1 m wide RCC balcony around the tank at the junction point of vertical wall and conical wall. 202 Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam up to manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 x 50 x 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. 203 Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expended mantled jail. 204 Lightening conductor as per I.S.S. 2309 of its latest electricity rules. It should consist proper elevation rod with 5test electricity rules. It should consist proper elevation rod with 5 of more fork points proper down conductors of prescribed mentale fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.roper size prescribed by ISS 2309-1969 and ISS 3013-1966. 205 C.I. manhole of min 60 x 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3 mm thickness hinged with locking arrangement. This manhole should be fixed at top domeat proper place. 206 Supply of fixing, jointing of following size of D.I. D/F pipes with D.I. D/F specials conforming to IS 329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest/ relevant I.S. specificationswith all jointing materials for proper completion of work including other appurtenant work and excavation in all types of soil. 207 Inlet pipe 250 mm 208 Outlet pipe 350 mm 209 Overflow pipe 250 mm 210 Washout pipe 100 mm 211 Supply and fixing of following sizes C.I. D/F sluice valves with Gear opreated as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete. 212 Inlet pipe 250 mm 213 Outlet pipe 350 mm (Gear Operated) 214 Washout pipe 100 mm 215 Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should support on the raft not on the soil. 216 Construction of Masonary type sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box includinglocking arrangement. 217 Construction of washout/overflow chamber as per departmental type design and drawing. 218 Construction of P.C.C. floor & drain and all other necessary work as per departmental type drawing and design. 219 Weather Coat painting of all concrete surface and enamal painting of steel pipe works with three coats of approved cement paint and anticorrosive paints. 220 Testing & Commission etc. all complete work. 221 Testing of bearing capacity of soil from a reorganized Govt. Engineering college or as directed by department. 222 RCC OHT Zone-III 223 Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, includingcost of soil testing and based on IS-3370 or liquid storage concrete in over head tank and oundation concrete as per specification in I.S. 2911. 224 350 KL with 24 m Staging 225 All components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456 226 Minimum depth of foundation below original ground level will be 2.0 227 SMei. smic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. 228 The assumed bearing capacity of soil has been taken as 8 M.T. sqm 229 1 m wide RCC stair case from ground level to balcony. 230 M.S. ladder made of 50 x 50 x 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to be top dome resting on an RCC plateform (75 x 75 cm and 10 cm thick) projecting from top ring beam and one alluminimum ladder inside thw tank body (from manhole in top dome to bootom dome). 231 1 m wide RCC balcony around the tank at the junction point of vertical wall and conical wall. 232 Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam up to manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 x 50 x 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. 233 Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expended mantled jail. 234 Lightening conductor as per I.S.S. 2309 of itslatest electricity rules. It should consist proper elevation rod with 5test electricity rules. It should consist proper elevation rod with 5 ofmore fork points proper down conductors of prescribed mentale fork points proper down conductors of prescribed mental ofproper size prescribed by ISS 2309-1969 and ISS 3013-1966.roper size prescribed by ISS 2309-1969 and ISS 3013-1966. 235 C.I. manhole of min 60 x 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3 mm thickness hinged with locking arrangement. This manhole should be fixed at top dome at proper place. 236 Supply of fixing, jointing of following size of D.I. D/F pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest/ relevant I.S. specifications with all jointing materials for proper completion of work including other appurtenant work and excavation in all types of soil. 237 Inlet pipe 150 mm 238 Outlet pipe 350 mm 239 Overflow pipe 150 mm 240 Washout pipe 100 mm 241 Supply and fixing of following sizes C.I. D/F sluice valves with Gear opreated as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete. 242 Inlet pipe 150 mm 243 Outlet pipe 350 mm (Gear Operated) 244 Washout pipe 100 mm 245 Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the verticalpipes. These bed blocks should support on the raft not on the soil. 246 Construction of Masonary type sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing includingsupply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement. 247 Construction of washout/overflow chamber as per departmental type design and drawing. 248 Construction of P.C.C. floor & drain and all other necessary work as per departmental type drawing and design. 249 Weather Coat painting of all concrete surface and enamal painting of steel pipe works with three coats of approved cement paint and anticorrosive paints. 250 Testing & Commission etc. all complete work. 251 Testing of bearing capacity of soil from a reorganized Govt. Engineering college or as directed by department. 252 REPAIRING OF TWO NOS. EXISTING CWR/OHT (375 Kl &450Kl) (ZONE-I) 253 Supply and fixing on lightening Conductor on O.H.T. with proper arrangement and alignment including all labour and T&P etc. complete. 254 The lightening conductor consisting of an elevation rod, down conductor and earth plate shall confrom with the standars as required by the Electircal Inspector of U.P from time to time , Any amendment , addition etc. suggested or required by the Electircal Inspector shall be carried out. 255 Water lavel Indicator 256 Supply and fixing of water level indicator with suitable arrangement as per latest I.S. code with all labour T&P etc. complete. 257 All exposed surface of structure to be given three coats of approved exterior cement paint Berger/ narolac / Asian ( Such as apex) to give a smooth and even colour. the pipe system of above aprorn level along with the clamps to be painted with three coats approved synthetic paints. including supply of all labour material T&P necessory Scafolding etc. complete. 258 Repairs of O.H.T. wall, water tighteing work including all labour, material etc required for completion of work. 259 Repairs of cracks on concrete OHT including all labour material extraholding etc required for completion of work. 260 Repairs & Replacement of OHT pipes & Specials including all labour, material etc required for completion of work. 261 Repairs & Replacement of Valves & carting including all required for completion of work. 262 Replacment of both M.S. Ladder (inner & outer) & MS cover on top dome including all labour, material etc required for completion of work. 263 Site clearence and other unforseen items. 264 REPAIR OF EXISTING BOUNDARY WALL (ZONE-I) 265 First class brick work in 1:4 cement and local sand mortar in super structure and plinth including supply of all materials, labour T&P etc required for proper completion of work. 266 12 mm thick plaster with cement and local sand mortar in proportion of 1:6 over brick work, minimum thickness not be less than 10 mm including supply of all materials labour, T&P etc required for proper completion of work. 267 Provision of coping on the top of wall 268 Provision of barbed iron wire fencing to posts in four rows. 269 Provision M.S. iron angle (50x50x6mm) for the barbed wire fixing and 2 meter 270 Cement concrete with 20 mm gauge approved stone ballast coarse sand and cement in proporation 4:2:1 including supply of all materials, labour, T&P etc required for fixing M.S. Iron angle proper completion of work. 271 Raised pointing with cement mortar 1:4 consisting or cement and local sand on brick work including supply of all materials. labour, T&P etc, of the wrok. 272 White washing in three coat including supply of all materials, labour, T&P etc. 273 complete required for proper completion of the work 274 Providing plaster of Paris wall 275 to prepare the surface even and smooth complete. 276 Apex Ultima /Acrylic Exterior/ interior paint of approved brand & manufacturer & of required shade on under coated wall surface to give anuniform surface over one primer coat of white cement of approved brand after thoroughly brushing and rubbing the surface free from mortar droppings & other foreign matters including prepairing even surface with plaster of paris including supply of all material labour T&P etc required for proper completion 277 Site clearence &other unforceen item. 278 Existing Boundry Wall Length 279 Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate. 280 Leveling, dressing, repairing of road in water works compound 281 REPAIR OF ONE NO. EXISTING STAFF QUARTER (ZONE-I) 282 Ist Class brick work in 1:4 cement and local sand mortar in superstructure including supply of all material, labour, T&P etc required for propercompletion of the work. (Thickness of wall to one brick thick). 283 12 mm thick plaster with cement & coarse sand mortar in 1:1:5 over brick work minimum thickness not to be less than 12 mm finished with 3 mmfloting coating of neat cement including supply of all materials, labour T&P etc. required for proper completion of the work. 284 Scraping old color washing and preparing the surface by removing loos material etc. including all labour and T&P etc complete. 285 40 mm thick over base concrete consisting of cement, local sand and 40 mm gauge first class brick ballast in the proportion of 1:4:8. For construction of apron 0.6 m wide. 286 White washing in three coat including supply of all materials, labour, T&P etc. complete required for proper completion of the work 287 Providing plaster of Paris wall putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 288 Apex Ultima /Acrylic Exterior/ interior paint of approved brand & manufacturer & of required shade on under coated wall surface to give anuniform surface over one primer coat of white cement of approved brand after thoroughly brushing and rubbing the surface free from mortardroppings & other foreign matters including prepairing even surface with plaster of paris including supply of all material labour T&P etc required for proper completion of work. 289 Supply and fixing of flush doors including supply of all materials, paints, labour T&P etc. required for proper completion of the work. 290 Repair for electric fitting 291 Repair for sanitation work 292 Site clearence and other unforseen items. 293 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD (ZONE-II) 294 Provide all materials; labour T&P etc. for the Boundary wall as per direction of Engineer-in-charge. 295 Main compound 296 Long wall 297 Short wall 298 Deduction for Main Gate 299 Deduction for Wicket Gate 300 Total 301 Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate. 302 Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road. 303 Main road in compound 304 For OHT 305 For Staff Quarter 306 Total 307 Construction of Drain as per type design in all materials, labour T&P etc. required for proper completion of work inside campous for proper drainage. Size (300 mm x 300 mm). 308 Provision of Lighting in campous as per direction of Engineer-in-charge including all materials , labour T&P etc complete. 309 Provision of land ecapping and aboriculture in campous as per direction of Engineer-in- charge including all materials , labour T&P etc complete. 310 Excavation work in excavation by mechanical means (Hydraulic excavator)/manual means over are as (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in-charge. 311 Provide all materials, labour T&P etc. required for proper completion of work including leveling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth. 312 For Main Compound 313 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD (ZONE-III). 314 Provide all materials; labour T&P etc. for the Boundary wall as per direction of Engineer-in-charge. 315 Main compound 316 Long wall 317 Short wall 318 Deduction for Main Gate 319 Deduction for Wicket Gate 320 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD (ZONE-III). 321 Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate. 322 Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road. 323 Main road in compound 324 For OHT 325 For WTP 326 For MCWR 327 For Staff Quarter 328 Total 329 Construction of Drain as per type design in all materials, labour T&P etc. required for proper completion of work inside campous for proper drainage. Size (300 mm x 300 mm). 330 Provision of Lighting in campous as per direction of Engineer-in-charge including all materials , labour T&P etc complete. 331 Provision of direction of Engineer-in-charge including all Engineer-in-charge including all materials , labour T&P etc complete. 332 Excavation work in excavation by mechanical means (Hydraulic excavator)/manual means over are as (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in-charge. 333 Provide all materials, labour T&P etc. required for proper completion of work including leveling, dressing excavationb and filling of earth where necessary for develop of water works site includingcarriage of earth. 334 For Main Compound 335 SUB STATION BUILDING (LT/HT ROOM / GENERATOR ROOM) 336 Provide all materials, labour T&P etc. and construct the sub statoinbuilding (LT/HT Room along with meter room) as per type design approved by Jal Nigam. 337 Raw Water Pumping Station Intake Well 338 Raw Water Pumping Station WTP 339 STAFF QUARTER FOR PUMP OPERATOR (ZONE-II) 340 Provide all materials, labour, T&P Complete and construction of a set of Single room Set Staff quarter for pump operator as per type design. 341 STAFF QUARTER FOR PUMP OPERATOR (ZONE-III) 342 Provide all materials, labour, T&P Complete and construction of a set of Single room Set Staff quarter for pump operator as per type design. 343 GROUND WATER RECHARGE WORK (ZONE-II) 344 Supply all materials, labour, tools and planta and provide arreangement for ground water recharge as per cost estimate attachment. 345 (i) At Water works 346 GROUND WATER RECHARGE WORK (ZONE-III) 347 Supply all materials, labour, tools and planta and provide arreangement for ground water recharge as per cost estimate attachment. 348 (i) At Water works 349 PUMPING PLANT AND ACCESSORIES FOR INTAKE WELL 350 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.21mtr/suitablelengthcolumnassembly, with vertical hollow shaft.Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 351 3100 LPM / 80 Mtr. HEAD / 100 HP MOTOR (2w+1s) Head & discharge may increased as per site requirement 352 MAIN PIPING AND VALVES :-Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outsidethe pump house along with 250 x 200 x 250 mm A/F Tee (03 Nos) , 250 mm bend (01 Nos), 250 mm blind flange (01 Nos), D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe, mechanical joints (04 Nos) and valve etc. complete in all respect Note -Suitable Sizeof Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner 353 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with 10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 354 Valve actuator of size :- 200mm for pumpsor more suitable size as per site condition with best engineering manner 355 Valve actuator of size :- 250mm for common header or more suitable size as per site condition with best engineering manner 356 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-16 to be fixed after pumps for 90% fast closing & 10% slow closing . 357 200 mm Dia for pumps or more as per site condition with best engineering manner 358 250 mm Dia for common header or more as per site condition with best engineering manner 359 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 360 Size 250mm for common header or more as per site condition with best engineering manner 361 ELECTRICAL ITEMS:- 362 Supply& laying of 1.1KV grade XLPE insulated armoured multi strand copper conductor cable of 3C x 35 sq.mm or more size suitable for pumping plant load from control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 363 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION630A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-2 No with suitable rating auto phase reversal unit, Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 364 Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including linecontactorssuitablefornextstandardhigherKWrating,Over& Underloadprotection,shortcircuit&singlephasingprotectionwith frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating suitable forcapacity 100 HP / 75 KW pumping plant 365 Supply of microprocessor based three phase sensing power factor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k settingaccordingtotargetedpowerfactorsetting,therelayshallhave digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have overloadprotection,novoltrelease,havingmultiparameterlikeKW, KVA, KVAR rating capacity of 91 KVAR or more suitable as per site requirement 366 CE/UL Certified level transmitter for Intake well :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 367 CE/UL Certified Pressure transmitter for pumps and common header :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 368 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) ( 01 job = seprate Double Earthing of each pumping plant and its pannel as per IER ) 369 Installation ,testing at site & manufacturer works or as per direction of Engineer Incharge andof all E/M equipments, power wiring of Electrical equipments and commissioning of the pumping plants. 370 3Ton or More suitable as per site requirement capacity hand operated over head Travelling (HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder 371 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 372 Cable trench Chequerred plate 373 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 374 Internal & External electrification of pumping station :- 375 Indoor Lighting 376 Surface Mounting 377 Providing & Fixing of IP-67 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 378 Suspended Mounting / Surface Mounting 379 36W LED light fixture 2×2 with acrylic / prismatic front cover. 380 Fans 381 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. 382 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 383 Installation, testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.with regulator 384 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. 385 450mm sweep (900/1400 RPM) 386 Fixing of fresh air fan/exhaust fan up to size of 300/450 mm on ply/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required. 387 Outdoor Lighting 388 Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 389 Compact Solar LED Street Light having protection of IP-67- 60W(MONO)18V / 12.8V27Ah /40W 390 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc .All sockets should be connected to sufficient size earth wire and seprate earthing for each pumphouse 391 250 KVA or more as per site requirement SUB STATION AT INTAKE WELL 392 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 393 Supply of 50 Sq.mm size XLPE HT cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 394 Supplying of 250 KVA or more suitable as per site requirements , 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 7.5% to -7.5%,at each step of 2.5 %having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 395 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, havingaluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each ACB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 320Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each MCCB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 1 Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 396 Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x240 sq mm) 397 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 398 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 399 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 400 Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable 401 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 402 NOC from Electrical safety department for all field installations such as pumping plants, substation etc. 403 PUMPING PLANT AND ACCESSORIES FOR MCWR TO ZONE-( I+II ) 404 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical hollow shaft .Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 405 2400 LPM / 54 Mtr. HEAD / 50 HP MOTOR (2w+1s)Head and discharge may increase and suitable as per site requirement 406 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 200mm common Header upto 1 m. outsidethe pump house along with 200 x 150 x 200 mm A/F Tee (3 Nos), 200 mm bend (01 Nos), 200 mm blind flange (01 Nos), D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (04 Nos) and valve etc. complete in all respect as per site conditions. Note - Suitable Sizeof Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner 407 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with 10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 408 Actuator with Sluice Valve of size :- 150mm or more size suitable as per site condition for pumps 409 Actuator with Sluice Valve of size :- 200mm or moresize suitable as per site condition for common header 410 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 411 150 mm Dia or more size suitable as per site condition 412 200 mm Diaor more size suitable as per site condition 413 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 414 Size 200mm or more size suitableas per site condition for common header with best engineering manner 415 ELECTRICAL ITEMS:- 416 Supply& laying of 1.1KV grade XLPE insulated armured multi strand copper conductor cable of 3C x 25 sq.mmOR more size suitable as per load of pumping plantfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 417 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION400A,50KA,TPN,MCCB microprocessorbaseed (O/C,S/C)release- 02 No with suitable rating auto phase reversal uint , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION160 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 418 Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including linecontactorssuitablefornextstandardhigherKWrating,Over& Underloadprotection,shortcircuit&singlephasingprotectionwith frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 45 KWfor operating 50 hp motor 419 Supply of microprocessor based three phase sensing power factor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k settingaccordingtotargetedpowerfactorsetting,therelayshallhave digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have overloadprotection,novoltrelease,havingmultiparameterlikeKW, KVA, KVAR rating capacity of 50 KVAR 420 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 421 CE/UL Certified Pressure transmitter for pumps and common header:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 422 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired Having resistance of Maximum 1 ohm.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) (01 job = seprate Double Earthing of each pumping plant and its pannel as per IER ) 423 Installation ,testing at site & manufacturer worksof all e/m euipments or as per direction of engineer incharge , power wiring of Electrical equipments and commissioning of the pumping plants. 424 3Ton capacity hand operated over head Travelling (HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder 425 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 426 Cable trench Chequerred plate 427 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 428 Internal & External electrification of pumping station :- 429 Indoor Lighting 430 Surface Mounting 431 Providing & Fixing of IP67LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 432 Suspended Mounting / Surface Mounting 433 36W LED light fixture 2×2 with acrylic / prismatic front cover. 434 Fans 435 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. 436 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 437 Installation, testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.with regulator 438 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. 439 450mm sweep (900/1400 RPM) 440 Fixing of fresh air fan/exhaust fan up to size of 300/450 mm on ply/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required. 441 Outdoor Lighting 442 Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system.( For MCWR ) 443 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W 444 Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. (for WTP) 445 12.5 Mtr. HM (in 2 Section) 446 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. 447 High Power LED Flood Light 200W 448 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 449 250 KVA or more as per requirements SUB STATION AT ( MCWR+WTP ) 450 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 451 Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 452 Supplying of 250 KVA or more rating suitable for site requirement, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, outdoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of2.5% with range+ 7.5% to -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 453 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :2 Nos. 630Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec.(IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 02 Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 454 Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x240 sq mm) 455 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 456 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 457 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 458 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 459 NOC from Electrical safety department for all field installations such as pumping plants, substation etc. 460 PUMPING PLANT AND ACCESSORIES FOR ZONE-3 OF MCWR 461 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical hollow shaft. Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 462 900 LPM / 36 Mtr. HEAD / 15 HP MOTOR (1w+1s)Head & discharge may increase as per site requirement 463 MAIN PIPING AND VALVES :-Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 100 x 100 x 100 mm A/F Tee (2Nos), 100 mm bend (01 Nos), 100 mm blind flange (01 Nos), D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) and valve etc. complete in all respect as per site conditions. Note - Suitable Sizeof Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner 464 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 465 Actuator with Sluice Valve of size :- 100mm or more size suitable for pumps 466 Actuator with Sluice Valve of size :- 100mm or more size suitable for common header 467 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 468 100 mm Dia or more size suitable for pumps and common header 469 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 470 Size 100mm or more size suitable for common header 471 ELECTRICAL ITEMS:- 472 Supply& laying of 1.1KV grade XLPE insulated armoud multi strand copper conductor cable of 3C x 6 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 473 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,MCCB microprocessorbaseed (O/C,S/C)release-2 No with suitable rating auto phase reversal unit, Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION63A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No(1w+1s+1 Spare), SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 474 Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including linecontactorssuitablefornextstandardhigherKWrating,Over& Underloadprotection,shortcircuit&singlephasingprotectionwith frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 15 KWfor 15 hp motor 475 Supply of microprocessor based three phase sensing power factor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k settingaccordingtotargetedpowerfactorsetting,therelayshallhave digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have overloadprotection,novoltrelease,havingmultiparameterlikeKW, KVA, KVAR rating capacity of 13 KVAR or more as per requirements 476 CE/UL Certified Pressure transmitter for pumps and common header:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 477 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)( 01 job = seprate Double Earthing of each pumping plant and its pannel as per IER ) 478 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants. 479 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 480 Cable trench Chequerred plate 481 Automation For Intake Well 482 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 483 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 484 CE/UL Certified Intelligent energy meters 485 CE/UL Certifiedthree phase Surge protector for control panel at main switch 486 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 487 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 488 Cable 489 (i) Complete cabling upto 3 Pumps 490 Security Survelliance IP Camera with recorder (optional) 491 Installation, commissioning & testing 492 Local Control Station at WTP 493 CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification 494 Desktop / PC with i5/i7 processor for as per technical bid documents 495 CE/UL Certified 5KVA UPS with batteries as per technical bid documents 496 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 497 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouser as per spec. mentioned in technical bid documents. 498 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 499 CE/UL Certified firewall for network protection 500 SURGE PROTECTOR FOR ETHERNET communication protection. 501 CE/UL certified industrial grade Ethernet Swtich 502 Cannon/HP or equivalent Laser printer 1018 or equivalent 503 Security Survillance IP Camera with recorder (Optional) 504 Installation, Commissioning & testing including required furniture, A/C etc. 505 AUTOMATION FOR MCWR 506 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 507 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 508 CE/UL Certified Intelligent energy meters 509 CE/UL Certified three phase Surge protector for control panel at main switch 510 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 511 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 512 Turbidity Analyzer at MCWR 513 PH Analyzer 514 Chlorine Analyzer 515 Cable 516 (i) Complete cabling upto 3 Pumps 517 Security Survelliance IP Camera with recorder (optional) 518 Installation, commissioning & testing 519 ESTIMATE FOR AUTOMATION OF EXISTING STORAGE / HILLOCK /CWR ( 450 KL+350KL=800 KL )AGAINST ZONE-1 520 ESTIMATE FOR AUTOMATION OF EXISTING STORAGE / HILLOCK /CWR ( 450 KL+350KL=800 KL )AGAINST ZONE-1 521 CE/UL Certified level transmitter for CWR / HILLOCK :- Supply of Radartype leveltransmitter with battery powerCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 522 CE/UL Certified Electromagnetic flow meter at CWR / HILLOCK outlet :- SupplyofCE/ULFullBorec ElectromagneticFlowMeterofapproved make with battary power for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 523 300 mm dia 524 CE/UL Certified Pressure transmitter at CWR / HILLOCK outlet :- Supply of CE/UL Certified pressure transmitter CE markd with battary power following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 525 Residual chlorine analyser / meter :-Supply of RCA with battary power must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 526 Installation , cabling of CWR/HILLOCK including all power and control cable of all equipmentsand commissioning complete in all respect. 527 CE/UL Certified 5KVA UPS with batteries as per technical bid documents 528 ESTIMATE FOR AUTOMATION OF PROPOSED OHT ( 1000 KL ) AGAINST ZONE-2 529 Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 530 400 mm dia 531 CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with battary powerCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 532 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 533 400 mm dia 534 CE/UL Certified Pressure transmitter at OHT outlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 535 Residual chlorine analyser / meter :- Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 536 Installation , cabling of CWR including all power and control cable of all equipmentsand commissioning complete in all respect. 537 ESTIMATE FOR AUTOMATION OF PROPOSED OHT ( 350 KL ) AGAINST ZONE-3 538 Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 539 300 mm dia 540 CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with battary powerCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 541 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 542 300 mm dia 543 CE/UL Certified Pressure transmitter at OHT outlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 544 Residual chlorine analyser / meter :- Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V acOutput : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 545 CE/UL Certified 5KVA UPS with batteries as per technical bid documents 546 Installation , cabling of CWR including all power and control cable of all equipmentsand commissioning complete in all respect. 547 03 Months trial & run withoutelectricity includingoperation and chemical charges (PAC) for 9 MLD and 02 nos chowkidar/months for watchward , 02 nos Technician/months and 04 nos SCADA operators/months for LCS .