Educational and Research Institute Private Organizations Closing in 0 days TDR #51609063

Tender For Procurement, Installation And Maintenance Of Electrical Fittings

Issued by Private Organizations · panaji, Goa
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Nov 2025
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
panaji → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Procurement, Installation And Maintenance Of Electrical Fittings , Wiringforlightpoint/Fanpoint/Exhaustfanpoint/ Callbellpointwith1.5Sq.Mmfrlspvcinsulated Copper Conductor Single Core Cable In Surface Pvc Conduit(Medium)Withmodularswitch,Modularplates, Suitablesize Modular Gi Boxofspecifiedcategory And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copperconductorsinglecorecableetc.Asrequired.(C) Group C-- With Cat A Modular Accessories , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modularplate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (C) Cat A , Supplying And Fixing3 Pin 5/6 Amodular Socket Outlet And 5/6A Modularswitch On Boardthemodular Surface/Recessed Pvc/Gimodular Box By Suitably Increasing Its Modular Capacity, Modular Plate And Cover Including Connection Painting Etc. As Required.(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Coverin Front On Surface Or In Recess Includingprovidingandfixing3pin5/6A Modular Socketoutletand 5/6A Modularswitchconnection Painting Etc. As Required(A) Cat A , Supplyingandfixing20a240vspnindustrialtype Socket Outlet With 2 Pole And Earth Metal Enclosed Plug Topalonwith20a,Cseries Spmcbinsheetsteel Enclosureinsurfaceorinrecesswithchainedmetal Cover For The Socket Outlet And Complete With Connections Testing And Commissioning Etc. As Required(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Coverin Front On Surface Or In Recess Including Providing And Fixing 6 Pin 15/16 A And 5/6 A Modular Socket Outlet Modular Socket Outlet And15/16 A Modularswitchconnectionpaintingetc.As Required(A) Cat A , Circuit Wiringfor Circuit/Submainwiring Alongwithearth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductorsinglecorecableintheindependentsurface Pvc Conduit ( Medium)Of Appropriate Size As Required. , (A) 2 X 1.5 Sq.Mm + 1 X 1.5 Sq.Mm Earthwire (20Mm Conduit) , (B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit , (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , (D) 2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earthwire (25Mm Conduit , (J) 4 X 6 Sq.Mm + 2 X 6 Sq.Mm Earthwire (32Mm Conduit) , (K) 4 X 10 Sq.Mm + 2 X 10 Sq.Mm Earthwire (32Mm Conduit) , Supplying Installation Testing And Commissioning Of Surface/ Recess Mounting Vertical Type 415 V Tpn, Double Door Mcb Db Of Sheet Steel Dust Protected Duly Phosphatisedandpowderpaintedinclusiveof200a Tinned Copper Busbar Common Neutral Link Earth Bar Din Bar For Mounting Mcbs Detachable Gland Knock Out Plate Andwith100a10kamccbasincomer Interconnection Between Incomer Mccb And Busbars Of Following Ways (But Without Mccb/Mcbs As Required) , (B) 8 Way With 100A Mccb As Incomer, Double Door, Cat A , Supplyingandfixingfollowingwaytpnsheetsteel, Double Door, Verticle Typemcb Distributionboard 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutralbusbarearthbardinnbardetachableglandplate Interconnectionsphosphotizedandpowderpainted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)Interconnection Between Incomer Mcb And Busbars Of Following Ways (But Without Mcbs As Required) , (C) 12 Way (8+36), Double Door, Vertical Type, Cat A , Supplyingandfixingfollowingwayspnsheetsteel Mcb Distribution Board 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required (But Without Mcb/Rccb/Isolator) , (G) 12 Way Double Door Cat A , (H) 16 Way Double Door Cat A , Supplyingandfixing6ato32a, Cseriesmcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , (A) Sp, Cat A , Supplyingandfixing40a, Cseriesmcbsuitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Dbcomplete With Connections Testing And Commissioning Etc As Required. , (D) Tp, Cat A , Supplyingandfixingfollowingratingfourpole(Triple Poleandneutral)415Vrccbhavingasensitivity Currentupto30main Theexistingmcbdbcomplete With Connections Testing And Commissioning Etc As Required , (C) 63 A, Cat A , Supplyingandlaying8swgcopperwireat0.5Mbelow Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supplyingandlaying6swggi Wireat0.5Mbelow Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Cable Supplyandlayingexcludingexcavationbutincluding Laying Material Like Sand Cusioning Protective Sand Covering And Tiles Of 4 Core Armoured Pvc/Xlpe Insulated,Pvcsheathedcopperconductorcableof1.1 Kv Gradewithisi Markconformingtois:1554(Part I) ,Is:7098(Parti)Withlatestamendmentsoffollowing Size. , 4 Core 2.5 Sq.Mm X Cu. , 4 Core 6 Sq.Mm , Supplyandlayingexcludingexcavationbutincluding Laying Material Like Sand Cusioning Protective Sand Coveringandtilesof 31/2Corearmouredpvc/Xlpe Insulated,Pvcsheathedaluminiumconductorcableof 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I),Is:7098(Parti)Withlatestamendmentsoffollowing Size. , 3 1/2 Core 35 Sq.Mm , 3 1/2 Core 50 Sq.Mm , 3 1/2 Core 95 Sq.Mm , Supplying And Laying 25 Mmx 5 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , 20 Mm Dia Isi Markedrigid Pvc Conduit(Heavy) Conforming To Is 9537 , 25Mmdiaisimarkedrigidpvcconduit(Medium) Conforming To Is 9537 , Led Tubelight Fixtures , S.I.T.C Of Led 2X2 Panellightcompletemake:- Luminac , Cat.No:- Lf-Ll-553)(24W)Or Equivalent , Supply And Erecting Of 48 Inch (1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories.(A) Cat A , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4Corepvcinsulatedpvcsheathed/Xlpealuminium Conductor Cable Of 1.1 Kv Grade, Completeas Required. , (1) 4 X 1.5/2.5 Sq. Mm , (3) 4 X 6 Sq. Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 31/2Corepvcinsulatedpvcsheathed/Xlpe Aluminiumconductorcableof1.1Kvgrade,Complete As Required. , (2) 3 1/2X 35 Sq. Mm , (3) 3 1/2X 50 Sq. Mm , (5) 3 1/2X 95 Sq. Mm. , Installation, Earthing, Testing And Commissioningof Pre- Wired Fluorescent Fitting/ Compact Fluorescent Fittings Of Alltypescompletewithallaccessoriesandtubeetc. Directly On Ceiling / Wall Including Connections With 1.5 Sq.Mmfrlspvcinsulatedcopperconductorsingle Core Cable And Earthing Etc. As Required , Earthingwithgiearthpipe2mtslong40mmdia Medium Class With Isi Mark,Ofapproved Brands, Includingaccessoriesandprovidingmasonryenclosure With Ci/Rcc Coverhaving Locking /Lifting Arrangement And Watering Pipe Etc.Withcharcoal Or Coke And Salt) As Requiredaspertheearthingdrawingprovidedbythe Engineer-Incharge.The Scope Of Work Includes The Following:A)Excavationof Pitofsize1.0X1.0X2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe,40Mmdiameterasperspecifications.C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Ofminimumresistivityi/Ctransportation.E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger , (B) In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosurewithci/Rcccover Havinglocking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Providedbytheengineer-Incharge.Thescopeofwork Includesthefollowing:A)Excavationof Pitofsize 1.0X1.0X3.0Mtrs(Min)Anddisposalofexcavatedsoil. C)Watering Gi Pipe, 20Mm, Class B,With Funnel As Per Specs. D)Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Blackagriculturesoilofminimumresistivityi/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testingofearthvaluewithearthmeggerand Certifications Of Its Value. Aluminium Tag With Embossed Earthingvaluetobe Attachedtothepipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). , (B) In Rocky Strata , Excavation In Hard Rock Including Re Filling The Tranch , Excavation In Soil Including Re Filling The Tranch , Laying Of Additional Cable In Exsisting Trach Using Additional Material Like Sand, Protective Covering For The Additional Cable Of Size Upto 4C X 95 Sq.Mm

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Oct-2025 BOQ Corrigendum BOQ 15-Nov-2025

BOQ

Name of Work:Procurement, Installation and Maintenance of Electrical Fittings
Sl. No. Item Description
1Wiringforlightpoint/fanpoint/exhaustfanpoint/ callbellpointwith1.5sq.mmFRLSPVCinsulated copper conductor single core cable in surface PVC conduit(medium)withmodularswitch,modularplates, suitablesize modular GI boxofspecifiedCategory and earthing the point with 1.5 sq.mm FRLS PVC insulated copperconductorsinglecorecableetc.asrequired.(c)Group C-- with Cat A Modular Accessories
2Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. asrequired (c) Cat A
3Supplying and fixing3 pin 5/6 Amodular socket outlet and 5/6A modularswitch on boardthemodular surface/recessed PVC/GImodular box by suitably increasing its modular capacity, modular plate and cover including connection painting etc. as required.(a) Cat A
4Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess includingprovidingandfixing3pin5/6A modular socketoutletand 5/6A modularswitchconnectionpainting etc. as required(a) Cat A
5Supplyingandfixing20A240VSPNindustrialtype socket outlet with 2 pole and earth metal enclosed plug topalonwith20A,Cseries SPMCBinsheetsteel enclosureinsurfaceorinrecesswithchainedmetal cover for the socket outlet and complete with connections testing and commissioning etc. as required(a) Cat A\"
6Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and15/16 A modularswitchconnectionpaintingetc.asrequired(a) Cat A
7CIRCUITWiringfor circuit/submainwiring alongwithearth wire with the following sizes of FRLS PVC insulated copper conductorsinglecorecableintheindependentsurfacePVC conduit ( medium)of appropriate size as required.
8(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit)
9(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit
10(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
11(d) 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit
12(j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit)
13(k) 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm Conduit)
14Supplying installation testing and commissioning of surface/ recess mounting vertical type 415 V TPN, double door MCB DB of sheet steel dust protected duly phosphatisedandpowderpaintedinclusiveof200A tinned copper busbar common neutral link earth bar din bar for mounting MCBs detachable gland knock out plate andwith100A10KAMCCBasincomer interconnection between incomer MCCB and busbars of following ways (but without MCCB/MCBs as required)
15(b) 8 way with 100A MCCB as Incomer, double door,Cat A
16SupplyingandfixingfollowingwayTPNsheetsteel, double door, Verticle typeMCB distributionboard 415 V on surface/ recess complete with tinned copper busbar neutralbusbarearthbardinnbardetachableglandplate interconnectionsphosphotizedandpowderpainted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBsas required)
17(c) 12 way (8+36), double door, Vertical type, Cat A
18SupplyingandfixingfollowingwaySPNsheetsteel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc.as required (but without MCB/RCCB/Isolator)
19(g) 12 way double door Cat A
20(h) 16 way double door Cat A
21Supplyingandfixing6Ato32A, CseriesMCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testingand commissioning etc as required
22(a) SP, Cat A
23Supplyingandfixing40A, CseriesMCBsuitable for lighting and other loads of following poles in the existing MCB DBcomplete with connections testing andcommissioning etc as required.
24(d) TP, Cat A
25Supplyingandfixingfollowingratingfourpole(triple poleandneutral)415VRCCBhavingasensitivity currentupto30mAin theexistingMCBDBcomplete with connections testing and commissioning etc asrequired
26(c) 63 A, Cat A
27Supplyingandlaying8SWGcopperwireat0.5mbelow ground level for conductor earth electrode includingsoldering etc. as required
28Supplyingandlaying6SWGGI wireat0.5mbelow ground level for conductor earth electrode includingsoldering etc. as required
29CABLESupplyandlayingexcludingexcavationbutincluding laying material like sand cusioning protective sand covering and tiles of 4 core armoured PVC/XLPE insulated,PVCsheathedcopperconductorcableof1.1 KV gradewithISI markconformingtoIS:1554(Part I),IS:7098(PartI)withlatestamendmentsoffollowingsize.
304 Core 2.5 sq.mm x Cu.
314 Core 6 sq.mm
32Supplyandlayingexcludingexcavationbutincluding laying material like sand cusioning protective sand coveringandtilesof 31/2corearmouredPVC/XLPE insulated,PVCsheathedaluminiumconductorcableof1.1 KV grade with ISI mark conforming to IS:1554(PartI),IS:7098(PartI)withlatestamendmentsoffollowing size.
333 1/2 Core 35 sq.mm
343 1/2 Core 50 sq.mm
353 1/2 Core 95 sq.mm
36Supplying and laying 25 mmx 5 mm GI strip at 0.5 mbelow ground as strip earth electrode including soldering etc. as required
3720 mm dia ISI markedRigid PVC conduit(Heavy)conforming to IS 9537
3825mmdiaISImarkedRigidPVCconduit(Medium)conforming to IS 9537
39LED TUBELIGHT FIXTURES
40S.I.T.C of LED 2X2 PANELLightcompleteMAKE:- LUMINAC , CAT.NO:- LF-LL-553)(24W)or equivalent
41Supply and erecting of 48 inch (1200mm sweep) ceilingfan, double ball bearing type, , complete with all accessories.(a) Cat A
42Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4CorePVCinsulatedPVCsheathed/XLPEaluminium conductor cable of 1.1 KV grade, completeas required.
43(1) 4 x 1.5/2.5 Sq. mm
44(3) 4 x 6 Sq. mm
45Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of31/2CorePVCinsulatedPVCsheathed/XLPEaluminiumconductorcableof1.1KVgrade,complete as required.
46(2) 3 1/2x 35 Sq. mm
47(3) 3 1/2x 50 Sq. mm
48(5) 3 1/2x 95 Sq. mm.
49Installation, earthing, testing and commissioningof pre- wired fluorescent fitting/ compact fluorescent fittings of alltypescompletewithallaccessoriesandtubeetc. directly on ceiling / wall including connections with 1.5 sq.mmFRLSPVCinsulatedcopperconductorsingle core cable and earthing etc. as required
50EarthingwithGIearthpipe2mtslong40mmdia medium class with ISI mark,ofapproved brands, includingaccessoriesandprovidingmasonryenclosure with CI/RCC coverhaving locking /lifting arrangement and watering pipe etc.withcharcoal or coke and salt) as requiredaspertheEarthingDrawingprovidedbythe Engineer-Incharge.The scope of work includes the following:a)Excavationof pitofsize1.0x1.0x2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe,40mmdiameterasperspecifications.c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil ofminimumresistivityi/ctransportation.e)Masonary chamber with proper foundation, cover plate and lockingarrangement. f) Testing of earth value with earth megger
51(b) In rocky strata
52Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
53Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosurewithCI/RCCcover havinglocking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing providedbytheEngineer-Incharge.Thescopeofwork includesthefollowing:a)Excavationof pitofsize 1.0x1.0x3.0mtrs(min)anddisposalofexcavatedsoil.c)Watering GI pipe, 20mm, Class B,with funnel as per specs. d)Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft blackagriculturesoilofminimumresistivityi/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testingofearthvaluewithearthmeggerand certifications of its value. Aluminium tag with embossed earthingvaluetobe attachedtothepipe.g)watering arrangement(plumbing will be paid seperately).
54(b) In rocky strata
55Excavation in hard rock including re filling the tranch
56Excavation in soil including re filling the tranch
57laying of Additional cable in exsisting trach usingAdditional material like sand, protective covering for the additional cable of size upto 4c x 95 sq.mm

AI Tender Summary

OUR REF NO 51609063
AUTHORITY Private Organizations
TENDER VALUE Ref. Documents
LAST DATE 15-11-2025
Authority
Authority Name Vidya Prabodhini College
Work Description Procurement, Installation And Maintenance Of Electrical Fittings , Wiringforlightpoint/Fanpoint/Exhaustfanpoint/ Callbellpointwith1.5Sq.Mmfrlspvcinsulated Copper Conductor Single Core Cable In Surface Pvc Conduit(Medium)Withmodularswitch,Modularplates, Suitablesize Modular Gi Boxofspecifiedcategory And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copperconductorsinglecorecableetc.Asrequired.(C) Group C-- With Cat A Modular Accessories , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modularplate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (C) Cat A , Supplying And Fixing3 Pin 5/6 Amodular Socket Outlet And 5/6A Modularswitch On Boardthemodular Surface/Recessed Pvc/Gimodular Box By Suitably Increasing Its Modular Capacity, Modular Plate And Cover Including Connection Painting Etc. As Required.(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Coverin Front On Surface Or In Recess Includingprovidingandfixing3pin5/6A Modular Socketoutletand 5/6A Modularswitchconnection Painting Etc. As Required(A) Cat A , Supplyingandfixing20a240vspnindustrialtype Socket Outlet With 2 Pole And Earth Metal Enclosed Plug Topalonwith20a,Cseries Spmcbinsheetsteel Enclosureinsurfaceorinrecesswithchainedmetal Cover For The Socket Outlet And Complete With Connections Testing And Commissioning Etc. As Required(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Coverin Front On Surface Or In Recess Including Providing And Fixing 6 Pin 15/16 A And 5/6 A Modular Socket Outlet Modular Socket Outlet And15/16 A Modularswitchconnectionpaintingetc.As Required(A) Cat A , Circuit Wiringfor Circuit/Submainwiring Alongwithearth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductorsinglecorecableintheindependentsurface Pvc Conduit ( Medium)Of Appropriate Size As Required. , (A) 2 X 1.5 Sq.Mm + 1 X 1.5 Sq.Mm Earthwire (20Mm Conduit) , (B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit , (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , (D) 2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earthwire (25Mm Conduit , (J) 4 X 6 Sq.Mm + 2 X 6 Sq.Mm Earthwire (32Mm Conduit) , (K) 4 X 10 Sq.Mm + 2 X 10 Sq.Mm Earthwire (32Mm Conduit) , Supplying Installation Testing And Commissioning Of Surface/ Recess Mounting Vertical Type 415 V Tpn, Double Door Mcb Db Of Sheet Steel Dust Protected Duly Phosphatisedandpowderpaintedinclusiveof200a Tinned Copper Busbar Common Neutral Link Earth Bar Din Bar For Mounting Mcbs Detachable Gland Knock Out Plate Andwith100a10kamccbasincomer Interconnection Between Incomer Mccb And Busbars Of Following Ways (But Without Mccb/Mcbs As Required) , (B) 8 Way With 100A Mccb As Incomer, Double Door, Cat A , Supplyingandfixingfollowingwaytpnsheetsteel, Double Door, Verticle Typemcb Distributionboard 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutralbusbarearthbardinnbardetachableglandplate Interconnectionsphosphotizedandpowderpainted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)Interconnection Between Incomer Mcb And Busbars Of Following Ways (But Without Mcbs As Required) , (C) 12 Way (8+36), Double Door, Vertical Type, Cat A , Supplyingandfixingfollowingwayspnsheetsteel Mcb Distribution Board 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required (But Without Mcb/Rccb/Isolator) , (G) 12 Way Double Door Cat A , (H) 16 Way Double Door Cat A , Supplyingandfixing6ato32a, Cseriesmcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , (A) Sp, Cat A , Supplyingandfixing40a, Cseriesmcbsuitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Dbcomplete With Connections Testing And Commissioning Etc As Required. , (D) Tp, Cat A , Supplyingandfixingfollowingratingfourpole(Triple Poleandneutral)415Vrccbhavingasensitivity Currentupto30main Theexistingmcbdbcomplete With Connections Testing And Commissioning Etc As Required , (C) 63 A, Cat A , Supplyingandlaying8swgcopperwireat0.5Mbelow Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supplyingandlaying6swggi Wireat0.5Mbelow Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Cable Supplyandlayingexcludingexcavationbutincluding Laying Material Like Sand Cusioning Protective Sand Covering And Tiles Of 4 Core Armoured Pvc/Xlpe Insulated,Pvcsheathedcopperconductorcableof1.1 Kv Gradewithisi Markconformingtois:1554(Part I) ,Is:7098(Parti)Withlatestamendmentsoffollowing Size. , 4 Core 2.5 Sq.Mm X Cu. , 4 Core 6 Sq.Mm , Supplyandlayingexcludingexcavationbutincluding Laying Material Like Sand Cusioning Protective Sand Coveringandtilesof 31/2Corearmouredpvc/Xlpe Insulated,Pvcsheathedaluminiumconductorcableof 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I),Is:7098(Parti)Withlatestamendmentsoffollowing Size. , 3 1/2 Core 35 Sq.Mm , 3 1/2 Core 50 Sq.Mm , 3 1/2 Core 95 Sq.Mm , Supplying And Laying 25 Mmx 5 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , 20 Mm Dia Isi Markedrigid Pvc Conduit(Heavy) Conforming To Is 9537 , 25Mmdiaisimarkedrigidpvcconduit(Medium) Conforming To Is 9537 , Led Tubelight Fixtures , S.I.T.C Of Led 2X2 Panellightcompletemake:- Luminac , Cat.No:- Lf-Ll-553)(24W)Or Equivalent , Supply And Erecting Of 48 Inch (1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories.(A) Cat A , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4Corepvcinsulatedpvcsheathed/Xlpealuminium Conductor Cable Of 1.1 Kv Grade, Completeas Required. , (1) 4 X 1.5/2.5 Sq. Mm , (3) 4 X 6 Sq. Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 31/2Corepvcinsulatedpvcsheathed/Xlpe Aluminiumconductorcableof1.1Kvgrade,Complete As Required. , (2) 3 1/2X 35 Sq. Mm , (3) 3 1/2X 50 Sq. Mm , (5) 3 1/2X 95 Sq. Mm. , Installation, Earthing, Testing And Commissioningof Pre- Wired Fluorescent Fitting/ Compact Fluorescent Fittings Of Alltypescompletewithallaccessoriesandtubeetc. Directly On Ceiling / Wall Including Connections With 1.5 Sq.Mmfrlspvcinsulatedcopperconductorsingle Core Cable And Earthing Etc. As Required , Earthingwithgiearthpipe2mtslong40mmdia Medium Class With Isi Mark,Ofapproved Brands, Includingaccessoriesandprovidingmasonryenclosure With Ci/Rcc Coverhaving Locking /Lifting Arrangement And Watering Pipe Etc.Withcharcoal Or Coke And Salt) As Requiredaspertheearthingdrawingprovidedbythe Engineer-Incharge.The Scope Of Work Includes The Following:A)Excavationof Pitofsize1.0X1.0X2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe,40Mmdiameterasperspecifications.C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Ofminimumresistivityi/Ctransportation.E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger , (B) In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosurewithci/Rcccover Havinglocking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Providedbytheengineer-Incharge.Thescopeofwork Includesthefollowing:A)Excavationof Pitofsize 1.0X1.0X3.0Mtrs(Min)Anddisposalofexcavatedsoil. C)Watering Gi Pipe, 20Mm, Class B,With Funnel As Per Specs. D)Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Blackagriculturesoilofminimumresistivityi/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testingofearthvaluewithearthmeggerand Certifications Of Its Value. Aluminium Tag With Embossed Earthingvaluetobe Attachedtothepipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). , (B) In Rocky Strata , Excavation In Hard Rock Including Re Filling The Tranch , Excavation In Soil Including Re Filling The Tranch , Laying Of Additional Cable In Exsisting Trach Using Additional Material Like Sand, Protective Covering For The Additional Cable Of Size Upto 4C X 95 Sq.Mm
Basic Detail
Tender No VPC/PM-USHA/CRP/25-26/ELE/537
Bidding Type Tender
Location
City panaji
State Goa
Key Dates
Publish Date 16 Oct 2025
Submission Date 15 Nov 2025
Open Date 17 Nov 2025
Finance
Tender Value Ref. Documents
Tender Fee 3000
EMD 10000
Exemption Available
Document List
dcccae2f-0620-4a8b-9af4-081d120f7d2c.html
BOQ_25321.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 15, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 15, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 17, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

dcccae2f-0620-4a8b-9af4-081d120f7d2c.html

xls

BOQ_25321.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender