}

Tender For Supply, Installation, Testing And Commissioning Of 5 Star, Inverter Type Split Air-Conditioning Units At Iucaa, Pune, pune-Maharashtra

Tender Notice

51609005
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of 5 Star, Inverter Type Split Air-Conditioning Units At Iucaa, Pune
Tender
Indian
Maharashtra
Pune
04-11-2025

Tender Details

Tender For Supply, Installation, Testing And Commissioning Of 5 Star, Inverter Type Split Air-Conditioning Units At Iucaa, Pune; 1 Supplying, installing, testing & commissioning split type variable speed inverter technology with DC Rotory Inverter Compressor, room air conditioning unit1.5 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 45dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.12 for 1.5 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coilblower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote. 2 Supplying, installing, testing & commissioning split type variable speed inverter technology with with DC Rotory Inverter Compressor. room air conditioning unit 2 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 47dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.05 for 2 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coilblower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote. 3 Supplying,laying/fixing,testingandcommissioningof appropriatenominalrefrigerantcopper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. 4 Supplying,laying/fixing,testingandcommissioningof appropriatenominalrefrigerantcopper pipe of 12.7 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. 5 Supplying,laying/fixing,testingandcommissioningof appropriatenominalrefrigerantcopper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete 6 Supplying,laying/fixing,testingandcommissioningof appropriatenominalrefrigerantcopper pipe of 6.4 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. 7 Drain piping in UPVC with all fittings, supports and clamps upto 20/25 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe. 8 Set of Power & Control Cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. forHiwall Split AC. 9 MS structural work structure for condensing units, Powder Coated 10 Core cutting in wall/slab/Beam for AC piping 11 Dismantling of existing split A/cs and refrigerant piping

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-11-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-11-2025
2 27-10-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-11-2025

Key Value

Document Fees
INR 590 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail