}

Tender For Construction Of Rajkiya Inter College Mohana, Orai Under Rastriya Madhyamik Siksha Abhiyan - Inter College Building 2 Providing Driving With Hydaulic Pilling Righ With Power Units And Installing Driven Cast-B-Situ Reinforced Cement Concrete P, mohana-Uttar Pradesh

Uttar Pradesh State Construction and Infrastructure Development Corporation Limited has published Tender For Construction Of Rajkiya Inter College Mohana, Orai Under Rastriya Madhyamik Siksha Abhiyan - Inter College Building 2 Providing Driving With Hydaulic Pilling Righ With Power Units And Installing Driven Cast-B-Situ Reinforced Cement Concrete P. Submission Date for this Tender is 22-10-2025. Manhole Construction Tenders in mohana Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

51608582
Tender For Construction Of Rajkiya Inter College Mohana, Orai Under Rastriya Madhyamik Siksha Abhiyan - Inter College Building 2 Providing Driving With Hydaulic Pilling Righ With Power Units And Installing Driven Cast-B-Situ Reinforced Cement Concrete P
Tender
Indian
Uttar Pradesh
Mohana
22-10-2025

Tender Details

Tender For Construction Of Rajkiya Inter College Mohana, Orai Under Rastriya Madhyamik Siksha Abhiyan - Inter College building 2 providing driving with hydaulic pilling righ with power units and installing driven cast-b-situ reinforced cement concrete piles of grade M5 of specified diameter and length below the pile cap, to carry safe working load not less them specified. Of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 300mm dia 3 Extra over single under ream for providing additional bulbs in under reamed piles, under specified (only the Nos. of extra bulbs are to be paid) 4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete 5 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Pile cap 8 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) 9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Plinth Beam 10 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 11 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Coloumn up to PB 12 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Coloumn 13 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 14 Providing& applying a coat of residual petrolium bitumen of grade of vg-10 of approved qualityusing 1.7 kg per sqm on dpc after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 12 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) 16 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Lintal Bend + Sunshade 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab Beam 20 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab 21 Steel reinforcement for R.C.C. work including straightening, cutting,Thermo-Mechanically Treated bars of grade Fe-500D or more. 22 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 23 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works (Z Section) 24 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works (MS Grill) 25 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 26 Approximate cost of Fittings with these rates are provided in the schedule screws for door and window etc. rates for estimating purposes. Fittings are to be supplied departmentaily. 27 Providing and fixing aluminium work for doors section of approved makes confirming to IS:1285, fixing with dash fastner of required dia and size ,including necessary filing up the gaps at junction i.e. at top bottom and sideswith required EPDM rubber/neoprene gasket etc.Aluminium section shall be smooth rust free , straight ,mitred and jointed mechanically wherever required including cleat angle .Aluminium snap beading for glazing/panelling C.P. brass/stainless steel screw all complete as per arhitectural 28 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with4.0 mm thick glass panes 29 Providing and fixing 1mm thik M.S sheetdoor with frame and diagonal braces of 40x40x6 mm. (1 1/2 x1 1/2x1/4) angle iron , 3.15 mm.(1/8)gusset plates at the junctions & corners ,hooks at top ,25 mm.(1), dia. Pulleys at bottom ,40x40x6 mm.(1 1/2 x1 1/2x1/4) angles & T iron guides at top & bottom respectively including locking arrangement with handles,etc. complete and applying one priming coat of approved lead point. 30 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) 31 12 mm cement plaster of mix1:6 (1 cement: 6 coarse sand) 32 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand)(Bearing Plaster) 33 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) Sunshade Plaster 34 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 35 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and including water thinnable priming coat with cement primer 36 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 38 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 39 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., completeSize of Tile 600x600 mm 40 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm 41 Kota Stone flooring over 20mm thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 42 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillarslaid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to matchthe shade of the slabs, including rubbing and polishing complete. 43 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. 44 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqmincluding pointing in white cement mixed with pigment of matching shade complete 45 Providing & Fixing Green Board 46 Providing and fixing U. p.v.c rain water pipe 110mm dia with shoe,door bend etc. 47 Providing and fixing of wall face unplastiside PVC mold fitting accessories for unplastiside rigid PVC rain water pipe coforming including joint with seal ring conforming to leaving 10 mm gap to thermal expension Cuppler (110 mm) 48 115 mm brick work in 1:4 cement and Coarse sand ofmortor in s/s in one brick thick wall including supply of all materials , labours and T&P etc. required for proper completion of the work. 49 Appron Work 50 Supply and filling of Moorum soil in plinth protection /appron 51 Brick work in 1:6 cement:sand moratr in Appron 52 Lean concrete in 1:4;8 in appron 53 25 mm p.c.c.flooring in 1:2;4 54 Providing & fixing Glass sttirups in flooring 55 Centering and Shuttering including strutting ,propping etc.and removal of form for Small lintels not exceeding 1.5 m clear span moulding as in cornices ,window sills ,string coures, bands,copings,bed plates anchor blocks and the like 56 Centering and Shuttering including strutting ,propping etc.and removal of form for Small lintels not exceeding 1.5 m clear span moulding as in cornices ,window sills ,string coures, bands,copings,bed plates anchor blocks and the like 57 Centering and Shuttering including strutting ,propping etc.and removal of form for Colums ,pillars,piers,Abutments,posts and struts 58 Centering and Shuttering including strutting ,propping etc.and removal of form for Suspended floor ,roof, landings ,balconies and access plateform 59 Appron Drain 60 Earth work in exacavation in trenches for foundations land for pipes cables etc. in ordinary soil (loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplusexcavated earth as directed by the Engineer i/c with in a lead of 50m. 61 Providing and laying in cement concrete 1:4:8 (1 cement :4coarse sand :8graded stoneaggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. 62 Class 150 Brick Work in1:4 cement and coarsesandof2.20fineness modulus mortar infoundation and plinth including supply ofall materials, labourand tools and plants etc. requiredforpropercompletion of the work. 63 12MM Th. Cement plaster 1:3 (cement & C.sand) with Neat Cement Finish 64 Lab work 65 Granite stone slab colour black, Cherry/Ruby redArea of slab upto 0.50 sqm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm CP brass tap with necessary CP brass union complete, inc painting of fitting and brackets, cutting and making good (600x450) 67 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all 15 mm nominal outer dia Pipes 68 Providing and fixing U. p.v.c rain water pipe 75mm dia with shoe,door bend etc. 69 Providing and fixing Brass bib cock of approved quality and colour. 15 mm nominal bore, 165 mm long, weighing not less 70 Septic Tank (100 Users) 71 Earth Work excavation in ordenory soil including 1.5 mtr. Lift & 30.00mtr. Lead with all Labour, T.&P. complete of work 72 PCC 1:4:8 Cement:Coarse sand:stone ballast 40mm size Under Floor 73 class m-150 Brick Work in 1:4 Cement:C.sand Mortor including supply of all material, Labour T.P.Complete of Work in Super Structer 74 RCC Work 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) in Stair case, Mumty Slab & Parapet Patta including Supply of all Material, Labour T.P etc. Compete pf Work. 75 Centring & Shutring Work 76 Centring & Shutring Work 77 M.S. Work in R.C.C. Work 78 12mm. Thick 1:3 Cement:C.sand Mortor Plaster with Neat Cement Finish 79 Providing & Laying of P.C.C. 1:2:4 for making Proper Chanel complete 80 Construction of Soak pit 1.80 dia 81 SUBMERSIBLE PUMP 82 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart bore log, including hire & running charges of all equipments, toois, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia 83 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia 84 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia 85 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 86 Development of tube well in accordance with IS: 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ic disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 87 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia 88 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. 89 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubeweli as per IS:2800 (part 1). 100 mm dia. 90 Supply of submersible pump of make KSB 1.0 HP with control panel, support wire etc. complete. 91 Providing 2 core PVC insulated submersible cable from pump panel to submersible pump 92 Providing and foxing GI pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore 93 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 94 Fire Hydrant System 95 Supply & fixing of welding Heavy Quality Class B, MS pipe conforming to IS:1239 (part-1) for pipes up to 150 mm dia and IS: 3589-1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with MS angle iron supports and fasteners etc. also painting with red oxide and PO red enamel paint with required wrapping Coating complete in all respects.100 mm 96 Supply & fixing of welding Heavy Quality Class B, MS pipe conforming to IS:1239 (part-1) for pipes up to 150 mm dia and IS: 3589-1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with MS angle iron supports and fasteners etc. also painting with red oxide and PO red enamel paint with required wrapping Coating complete in all respects.80 mm 97 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 98 Supplying and fixing single headed internal hydrant valve With instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia With cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal /Stainless Steel cap and chain as requiredSingle headed Stainless steel 99 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required. Stainless Steel (Grade 304) 100 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304) 101 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304 sheet with 3 mm dia holes with stainless steel flange 100 mm dia 102 Supplying (Grade and 304) fixing With orifice plate Of made required out size of 6 to mm be fitted thick tO stainless between reduce flange & landing valve of external and internal hydrants pressure at the outlet to the level of 3.5 kg/cm2 complete as required 103 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way - 100 mm dia M.S. Pipe 104 Providing, installation, testing and commissioning of non-returr valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm 105 Supplying, fixing, testing and commissioning mmiecinning of of butterfly butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to 1S 13095 of following 100 mm 106 S/F of Air Vessel made of 250 mm dia, 8 mm thick MS Sheet, 1200 mm in Height With air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories,pressure gauge and painting with synthetic enamel paint of approved shade as required. 107 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520 (C) Suitable HP squirell cage induction motor TEFC type suitable for pperation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to l$-325 (D) M.S. fabricated common base plate, coupling, coupling guard foundation bolts etc. as required (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 108 Supplying and fixing of Pressure Switch inM S pipe line including connection etc. as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1010 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 16 sq mm x 4 core 110 SITC of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted FIRE in red luminous paint. The size of the boxshould be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. 111 Supply, Installation, Testing & Commissioning of Pressure Gauge. 112 SITC of Factory fabricated wired metal clad dust and vir,min proof floor mounting main electric control panel for terrace pumpwith starter switches selectors voltmeter etc. 113 S/F of Al Lugs & Gland complete in all respect. 114 Supply and making sheet for terrace pump 115 Fire Alarm System 116 Supplying, installation, testing & commissioning of manual call boxes of M.S. Construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 117 Supplying, installation, testing & commissioning of Fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 118 Supplying, inatallation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuite fault, fire condition and all other standard facilities as per IS: 2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone 119 Wiring for light / power plug with 2 x 1.50 sq. mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit, along with 1 No. 1.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required. 120 S/F of 7 AH 12 Volt Battery. 121 Sanitary & Water Supply 122 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 123 Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required . 124 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 125 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern 126 Providing and fixingP.V. C. Pipe 6kg.Pis including all Material, Labour T.&P. Complete of work. 110 mm dia. 127 Providing and fixingP.V. C. Bendincluding all Material, Labour T.&P. Complete of work. For 110 mm dia. 128 Providing and fixingP.V. C. N Trapeincluding all Material, Labour T.&P. Complete of work. 100*100mm. 129 Providing and fixingof P.V.C. Copler For 110 mm dia. 130 Providing and fixingof P.V.C. Tee For 110 mm dia. 131 Providing and fixingof P.V.C. Door Bend For 110 mm dia. 132 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 15 mm dia. nominal bore 133 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 20 mm dia. nominal bore 134 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 25 mm dia. nominal bore 135 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore 136 Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore 137 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 20 mm nominal bore 138 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore 139 Cutting holes upto 30x30 cm in walls including making good the same : With F.P.S. bricks. 140 Providing and fixing C.P. brass Piller cock Sencered of approved quality conforming to IS:8931 as such Hindwair 15 mm nominal bore. 141 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. 142 Providing and fixing C.P. brass long body /shortbody bib cock of approved quality conforming to ISstandards andweighing not less than 690 gms.as Such Hindwair 15 mm nominal bore 143 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 as Such Hindwair 15 mm nominal bore 144 Providing & Placing of polyethylene waterstorage tank, ISI 12701 locking arregment and making necessary holes for inlet, outlet and overflowpipes but without fittings. (10000 for fire) 145 Providing & Making of Platefom for 5000 Ltr. P.V.C. Water Storege Tank. 146 Providing & Fixing of Disable Toilet Kit set complete such as make Hindwair or Eq. 147 External Service Connection 148 Construction of Manhole 60x60x75 cm size complete 149 Construction of Sewer line 100mm dia complete 150 Providing and laying G.I. pipe 32mm dia for water supply 151 Levelling 152 Electrical Work 153 Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit,with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group C 154 Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 155 Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 156 Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit as required. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 157 Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 158 Supplying and Drawing following sizes ofFRLS PVC insulated copper conductor single core cable in the existing surface / recessed medium classPVC conduit as required. 3 x 1.5 Sq.mm 159 Supplying and Drawing following sizes ofFRLS PVC insulated copper conductor single core cable in the existing surface / recessed medium classPVC conduit as required. 3 x 4 Sq.m 160 Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 161 Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. modular base and cover plate for modular switches in recess etc. as required. 5 / 6 A Switch 162 Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. modular base and cover plate for modular switches in recess etc. as required. 3 pin 5 / 6 A socket outlet 163 Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required.Single pole 164 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required.40 Amp. 165 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, double door 166 Supply and fixing of Following way , surafce / recess,Vertical type ,415 v TPN MCB distribution board of sheet steel , dust protected duly powder painted , including of 200 a tinned copper bus bar , comman neutal link , earth bar , din bar for mounting MCBsetc. as required 6 way(4+12) Double door 167 63 amp FP isolator 168 Installation, testing and commissioning of ceiling fan, including wiring of the down rods of standard length (upto 30 cm) with 1.50 sq. mm, FRLS PVC insulated, copper conductor, single core cableincluding providing and fixing phenolic laminated sheet cover on the fan box etc.. as required. 169 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.. as required. Upto 450 mm sweep. 170 Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 171 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junctiorpox/ wooden block including connections etc. as required. Each 172 Supplying and fixing brass batten/ angle holder including connectionetc. as required 173 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required. 174 Supply & Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitablesize or as directed by the Engineer-Incharge, complete in all respect. Including excavation and refiling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 sq.mm x 3½ core. 175 Supply and fixing of recess / surface mounting round 15 to 18 Watt cut out min 150 mm, Height Min 40 mm, LED Down lighter having with heat sink, diffuser die cast aluminium housing with heat sink, diffuser/Reflector and driver set, suitable for 24 Hr. Continuous Operation, complete in all respect. CAT: AAA, 1980 - 2200 system lumens, 110 lm/W, PF>0.95, THD<10%, at full load, CRI>80, with 5 year warranty. 176 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten light fitting 2 x 22 Watt suitable for upto 2 X 22 W LED Polycarbonate tube light complete including tube etc. on surface complete in all respects. CAT: AAA, 2420 system lumens, 110 lm/W, PF>0.95,THD<10% at full load, CRI>80, Tube with aluminium heat with 5 year warranty. 177 Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. 2420 system lumens, 110 Lm/watt, PF > 0.95, THD<10%, at full load CRI>80, Tube with aluminium sink hit with 3 year warrantee Cat AA 178 Supply and fixing of water tight oblong 10 watt LED bulkhead luminaire having die cost housing with driver set confirming to IP 65 and above protection. complete in all respect. 1100 system lumens, 110 Lm/watt, PF > 0.95, THD<10%, at full load CRI>80, with 3 year warrantee Cat AA 179 Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 60 to 72 watt. Confirming to IP 66 and above Protection complete in all respect. 7200-8640 system lumens, High power LED with lenses, 120 Lm/watt, PF> 0.95, THD<10%, at full load, CRI>70, > 440 V & >300 V autocut & restarts feature with 5 year warrantee Cat AAA 180 S/F of 50 Amp. to 63 Amp. SPMCB (10 KA) Cat-B 181 S/F of surface/Flush mounting 4 ways V TPN distribution board with additional door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. Cat.-B 182 S/F of 80 Amp. To 100 Amp. 4 pole MCCB (16 KA) Thermal Magnetic release. Cat-B 183 Supply & Laying of 25 mm x 3 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect. 184 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. 185 Supply and fixing of 16 gauge M S drum with louvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respects . 186 Supply and fixing of water tight oblong 10 watt LED bulkhead luminaire having die cost housing with driver set confirming to IP 65 and above protection. complete in all respect. Cat AA 187 Supply and fixing of crimping, solderless, copper tin electroplated lugs of Dowells/Ismail make suitable for 1.5 sq.mm to 25 sq.mm cables, including tapping with insulating tape, complete in all respect. 188 S&F of Fire extinguisher, ABC Type 6.00 Kg. capacity (ISI marked IS: 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 189 S&F of Co2 type Fire extinguisher, 4.5 Kg. capacity (ISI marked IS: 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 190 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 191 S&L of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality. 192 S&F of shock treatment chart (Prescribed under I.E Rule) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. 193 63 amp TPMCB CAT-B 194 Supply and fixing ofhexagonal / round G P fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.40 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.50 mm G P sheet made upper & lower cover duly screwed fitted with 300 mm round zink cotedM.S. barx 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roofbefore concreting along with supply of all material, labour, T&P etc. required for proper completion of work. 195 Supply and fixing of 100 Amp. Four pole Change over switch on 50 mm x 50 mm x 6 mm angle iron frame , including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 196 Supply & Fixing of Fan Sheet of Backelite 197 S/F of LED Bulb 9 watt ISI 198 Supply & Fixing oflight duties exhaust fan 12”dia ISI double ball bearing metalic Usha / Crompton/Bajaj make 199 Supply & Fixing ofexhaust fan luvers 12”dia 200 S/f of ceiling fan 1200 mm sweep. Single star rated Usha / Crompton/Bajaj mak 201 S/F of Kit-Kat fuse 200 Amp with neutrail link ,wooden ply board ,Hole fasner with connection 202 S/F Required Lugs, Gland ect. 203 Lighting Conductor 204 Supply and burying earth electrode for lighting conductorof 600mm x 600mm x 3mm Copper plate vertically withits top at least 3 metres below ground level complete with20mm dia G.I. pipe for watering funnel, 30cm square C.I.frame with hinged cover masonry housing alternate layersof charcoal/coke and salt at least 150mm thick alroundetc. as per directions of Engineer-in-charge complete inall respect. 205 Supply & Laying of 32 mm x 6 mm Copper Strip from earth electrode directly in the ground as required complete in all respect. 206 Rain Water Harvesting 207 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earthas directed by the Engineer i.c. within a lead of 30 m. up tp 1.50mtr. 208 Providig and laying cement concrete 1:4:8 (1cement:4fine sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. 209 R.C.C. works with cement approved coarse sand and 20mm gauge approved stone grit in the proportion 1:2:4 (1cement:6aggregate) in lintels of doors and windows excluding supply of reinforcement and its bending& binding. but including its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labours, tools and plants etc required for proper completion of the works. Binding wire cost being included in the item 210 Centring & Shutring Slab 211 Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. 212 15mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc. 213 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. 214 Providing M.S. foot rests including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size) as per standard design : 215 Providing & Fixing of Posititon Precast RCC Manhole cover and frame of Required shape and approved quailty 216 Excavating trenches of required width for pipes, cables, etc includingexcavation for sockets, and dressing of sides, ramming of bottoms, depthupto 1.5 m, including getting out the excavated soil, and then returningthe soil as required, in layers not exceeding 20 cm in depth, includingconsolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 300 mm dia but not exceeding600 mm 217 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipeswith collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 218 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thickwith cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement completeas per standard design : Inside size 60x60 cm and 45 cm deep including C.I.Size 90x80 cmcover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) : 219 Supplying and stacking at site.90 mm to 45 mm size stone aggregate 220 Stone screening 11.2 mm nominal size (Type B) 221 Red Bajri 222 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.300mm. dia 223 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100mm. dia 224 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100mm. dia 225 Providing and packing of coarse sand around the pipe

Key Value

Document Fees
INR 3540 /-
EMD
INR 321000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail