}

Tender For Running Contract For Deposit Works Under Edd-Shahjhanpur Road, Bareilly - The Work Of Safe Carriage Of The Following Material From Cb Ganj Store Center To Work Siteunder The Jurisdiction Of Edd-Ii, Bareilly. Approx. Distance Upto 80 Km. Includi, Bareilly-Uttar Pradesh

Tender Notice

51599124
Corrigendum : Tender For Running Contract For Deposit Works Under Edd-Shahjhanpur Road, Bareilly - The Work Of Safe Carriage Of The Following Material From Cb Ganj Store Center To Work Siteunder The Jurisdiction Of Edd-Ii, Bareilly. Approx. Distance Upto 80 Km. Includi
Tender
Indian
Uttar Pradesh
Bareilly
27-10-2025

Tender Details

Tender For Running Contract For deposit Works Under Edd-Shahjhanpur Road, Bareilly - The work of safe carriage of the following material from CB Ganj store center to work siteunder the jurisdiction of EDD-II, Bareilly. Approx. distance upto 80 Km. Including safe loading and unloading. 2 PCC Pole 8.5 meter long. 3 STP 9 Mtr Long 4 STP 11 Mtr Long 5 Other Line material (Except Pole) i.e., cross arm/ conductor/ pin insulator/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE/LT XLPE Cable etc 6 11/0.4 KV 1 Phase 10/16 KVA T/F 7 11/0.4 KV 3 Phase 25 KVA T/F 8 11/0.4 KV 3 Phase 63 KVA T/F 9 11/0.4 KV 3 Phase 100 KVA T/F 10 11/0.4 KV 3 Phase 250 KVA T/F 11 11/0.4 KV 3 Phase 400 KVA T/F 12 11 KV Pilfer proof Metering cubical and CT PT Unit 13 33 KV Pilfer proof Metering cubical and CT PT Unit 14 33 KV Line Isolator 800 Amp 15 33 KV VCB 800 A, 750 MVA 16 33 KV Control Panel for Single Transformer 17 33 KV Control Panel for Double Transformer 18 11 KV Bus Cupler 19 33 KV CT 200/100/1-1A 20 33 KV Lightening Arrestor 21 Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms 22 PCC Pole 8.5 Mtr Long Single Pole 23 PCC Pole 8.5 Mtr Long Double Pole 24 ST Pole 9 Mtr Long Single Pole. 25 ST Pole 9 Mtr Long Double Pole. 26 ST Pole 11 Mtr Long Single Pole. 27 ST Pole 11 Mtr Long Double Pole. 28 Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms 29 PCC Pole 8.5 Mtr Long Single Pole 30 PCC Pole 8.5 Mtr Long Double Pole 31 ST Pole 9 Mtr Long Single Pole. 32 ST Pole 9 Mtr Long Double Pole. 33 ST Pole 11 Mtr Long Single Pole. 34 ST Pole 11 Mtr Long Double Pole. 35 The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms 36 Dismantling of Old and damaged conductor complete in all respect 37 Dismantling of PCC/ST Pole due to line shifting/damaged complete in all respect 38 Dismantling of Existing Distribution Transformer for increasing capacity/Shifting complete in all respect 39 11/0.4 KV 3 Phase 25 KVA T/F 40 11/0.4 KV 3 Phase 63 KVA T/F 41 11/0.4 KV 3 Phase 100 KVA T/F 42 11/0.4 KV 3 Phase 250 KVA T/F 43 11/0.4 KV 3 Phase 400 KVA T/F 44 Laying, Stringing & Sagging of Following Conductor complete in all respect 45 ACSR Weasal Conductor 46 ACSR Rabbit Conductor 47 ACSR Dog Conductor 48 3 Phase Arial Bunched Conductor 49 1 Phase Arial Bunched Conductor 50 After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand formDouble Pole to metering room complete in all respect. Alongwith filling ofcable jointing kits 51 After Mounting of CT PT unit on double pole, laying of 50 Mtr 33 KV 3cx120 sq mm cable in single circuit on river sand formDouble Pole to metering room complete in all respect. Alongwith filling ofcable jointing kits 52 Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Alongwith filling ofcable jointing kits 53 11 KV XLPE Cable Size 3x70 sqmm 54 11 KV XLPE Cable Size 3x120 sqmm 55 11 KV XLPE Cable Size 3x185 sqmm 56 33 KV XLPE Cable Size 3x120 sqmm 57 33 KV XLPE Cable Size 3x185 sqmm 58 33 KV XLPE Cable Size 3x300 sqmm 59 Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing complete in all respect.Alongwith filling ofcable jointing kits 60 11 KV XLPE Cable Size 3x70 sqmm 61 11 KV XLPE Cable Size 3x120 sqmm 62 11 KV XLPE Cable Size 3x185 sqmm 63 33 KV XLPE Cable Size 3x120 sqmm 64 33 KV XLPE Cable Size 3x185 sqmm 65 33 KV XLPE Cable Size 3x300 sqmm 66 Hoisting of Following size 11 KV & 33 KV XLPE Cableon double pole with GI pipe of size 6 dia 4 Mtr long including the jumpering complete with clamps , nut and bolts. 67 11 KV XLPE Cable Size 3x70 sqmm 68 11 KV XLPE Cable Size 3x120 sqmm 69 11 KV XLPE Cable Size 3x185 sqmm 70 33 KV XLPE Cable Size 3x120 sqmm 71 33 KV XLPE Cable Size 3x185 sqmm 72 33 KV XLPE Cable Size 3x300 sqmm 73 Filling of Cable Boxes For Suitable size 11/33 KV XLPE Cable 74 Supply & Laying of 6 dia G Pipe at various places i.e road crossing & Hoisting etc. complete in all respect ((ISO certified GI pipe 150 NB 3 mm thick dia 6 would be Provided by contractor at his own cost) 75 Supply & Laying of 140 mm OD PN-4 PE-80 Grade UV Sabilized HDPE Pile as per IS 4984 in 6 meter (would be Provided by contractor through approved vendors of Discom at his own cost) 76 Construction of T/F plinth 1.5x1.5x2 m3 for mounting 250/400 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect All manpower, material and T&P provided by the contractor to complete the work. 77 Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5(L)x5(W)x8’(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation. 78 The work of digging of pits, erection of Stay Clamp, Insulator etc. 79 Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. 80 Installation of 11 KV Fuse Set 81 Fixing of 11 KV TPMO 82 Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 83 Installation of 33 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 84 Installation of LT Incoming Panele with metering eauipment & fixing arrangement for LT Circuit Deistribution complete in all respect as per norms 85 Mounting of Following Capacity Transformers as per norms complete in all respect - 86 10/16 KVA T/F 87 25 KVA T/F 88 63 KVA T/F 89 100 KVA T/F 90 250 KVA T/F 91 400 KVA T/F 92 Fixing of Distribution Box complete in all respect 93 Guarding at road crossing complete in all respect 94 Fixing of Following Material as per Norms complete In all respect 95 33 KV Line Isolator 800 Amp 96 33 KV VCB 800 A, 750 MVA 97 33 KV Control Panel for Single Transformer 98 33 KV Control Panel for Double Transformer 99 11 KV Bus Cupler 100 33 KV CT 200/100/1-1A 101 33 KV Lightening Arrestor 102 Plinth & Foundation for 33 KV VCB as per norms complete in all respect 103 Supply & Fixing of Following Items to complete the work (Provided by the contractor through approved vendon of Discom/UPPCL, If Not available in stores) 104 LT Clamps as per RESSPO Norms for PCC/ST pole 105 Nut & Bolt off size 106 F Clampas per RESSPO Norms 107 Shackle Insulatoras per RESSPO Norms 108 X-Arm Holding Clampas per RESSPO Norms 109 Holding Clamp For T-Off 110 Holding Clamp For G I Pipe 111 Clamps with Nut & Bolt for Top & Dropper Channel 112 Stay Clampsas per RESSPO Norms 113 11 KV Composite Polymer Disc insulatoras per RESSPO Norms 114 Top Channel of size 100x50x2240 mmas per RESSPO Norms 115 T off Channelas per RESSPO Norms 116 11 KV Pin Insulator as per RESSPO norms 117 11 KV Pin Insulator with Pin & Nut as per RESSPO norms 118 11 KV Pin with Nut as per RESSPO norms 119 11 KV Disc Insulator With Fitting 120 Stone Pad 121 11 KV Steel X Arm V-Type 122 Danger Board 123 Danger Board Barbed Wire Including Jumper 124 Aluminium Paint 125 Red Oxide Paint 126 Barbed Wire 127 LT Shackle Insulator 128 PG Clamp 129 11 T-Off (125x65x1300mm) 130 11 KV Disc FittingWith Insulator (45 KN (T&C Type) 131 Guarding Angle 65x65x6 mm 1.6 Mtr Long 132 Clamp For Guarding Angle with Nut & Bolt 133 GI Wire 6 SWG & 10 SWG For Guarding & Lacing 134 Nut & Bolt with Washer 135 MS Angle Iron 65x65x6 mm, 2700 mm long Bracing with 4 Clamp 136 J-Huck 137 Suspenstion Clamp 138 Piercing Connector 139 Al Lug 630 Sqmm 140 Safe back carriage of Scrap (if any) from work siteto C.B. Ganj store Bareilly approx distance upto 80 Km including safe loading & unloading. 141 Safe back carriage of Distribution Transformer from work siteto C.B. Ganj store Bareilly approx distance upto 80 Km including safe loading & unloading. 142 11/0.4 KV 3 Phase 25 KVA T/F 143 11/0.4 KV 3 Phase 63 KVA T/F 144 11/0.4 KV 3 Phase 100 KVA T/F 145 11/0.4 KV 3 Phase 250 KVA T/F 146 11/0.4 KV 3 Phase 400 KVA T/F 147 Cutting of Tree Branches

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 18-10-2025 20/EDCB/2025-26 Date 27-10-2025

Key Value

Document Fees
INR 3540 /-
EMD
INR 100000.0 /-
Tender Value
INR 1 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail