}

Tender For Repair Maintenance Of Flame Proof Wiring Flam Proof Accessories Electric Meter Smart Meter Internal Electric Infrastructure And Allied Works At Af Station Manauri., manauri-Uttar Pradesh

Tender Notice

51591348
Tender For Repair Maintenance Of Flame Proof Wiring Flam Proof Accessories Electric Meter Smart Meter Internal Electric Infrastructure And Allied Works At Af Station Manauri.
Tender
Indian
Uttar Pradesh
Manauri
18-10-2025

Tender Details

Tender For Repair Maintenance Of Flame Proof Wiring Flam Proof Accessories Electric Meter Smart Meter Internal Electric Infrastructure And Allied Works At Af Station Manauri.; 1 Supply, install, testing and commissioning of LT panel size 100 cm x 100 cm x 40 cmenclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door withfront and rear openable with locking arrangement incl inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-INCOMING :-(i)MCCB 200 Amp ,415 Volt,35 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frametype,Confirms to IS/IEC60947-2 - 02 Nos(ii) On load change over switch capacity 200 Amp, 4 pole, 415 V, , Size FR3, Type CO3-200,site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal mountingcomplete with all fixing accessories complete.(iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly providedwith suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No 2 (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm – 01 No.(vii) Aluminium bus bar350 Amps capacity of suitable length insulated heavy heatshrinkable sleeves etc -04 Nos.OUT GOING (i) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along with all accessories.-01 No(ii) Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 100 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along - 02 Nos 3 Supply, install, testing and commissioning of LT panel size 110 cm x 90 cm x 40 cmenclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door withfront and rear openable with locking arrangement incl inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-INCOMING :-(i)MCCB 400 Amp ,415 Volt,36 KA, 50 Hz, 4 pole Rated Adjustable thermal and fixed magnetic setting ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 100%, LS frametype,Confirms to IS/IEC60947-2- Qty - 01(ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly providedwith suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm – 01 No.(vi) Aluminium bus bar630 Amps capacity of suitable length insulated heavy heatshrinkable sleeves etc -04 Nos. 4 OUT GOING (i)MCCB 200 Amp ,415 Volt,25 KA, 50 Hz, 4 pole Rated Adjustable thermal and fixed magnetic setting ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 100%, frametype,Confirms to IS/IEC60947-2- Qty - 02 Nos.(ii)MCCB 160 Amp ,415 Volt,25 KA, 50 Hz, 4 pole Rated Adjustable thermal and fixed magnetic setting Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 100%, frametype,Confirms to IS/IEC60947-2- Qty - 02 Nos . 5 Supply, install, testing and commissioning of LT panel size 80 cm x 80 cm x 40 cmenclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door withfront and rear openable with locking arrangement incl inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-INCOMING :-(i)MCCB 160 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frametype,Confirms to IS/IEC60947-2 - 01 No (ii) On load change over switch capacity 160 Amp, 4 pole, 415 V, , Size FR3, Type CO3-200,site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal mountingcomplete with all fixing accessories complete(iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.(iv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos(v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly providedwith suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No. 6 (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm – 01 No.(vii) Aluminium bus bar320 Amps capacity of suitable length insulated heavy heatshrinkable sleeves etc -04 Nos.OUT GOING (i) Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 100 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along - 02 Nos (ii) Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 63 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) along - 02 Nos 7 Supply , installation, testing and commissioning and testing of power factor improvement panel of capacity 100 KVAR size of panel 1100 mm x 700 mm x 250 mm, fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel,factory made, weather proof , dust and vermin proof (IP 65) suitable forHumidity: up to 95%,Average daily temperature: +35°C max,Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle ironlegs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copperNYVIN cable of suitable size and PVC flexible conduit medium quality as required , comprising of the following:-(A) Insulated Bus bar of aluminium of 250 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue Colour, Bus bar support should be of SMC/DMC, Rated Impulse Withstand Voltage 8KV -01 Set 8 ( B) Incommer MCCB 250 Amp , three pole, short circuit breaking capacity 36 KA Icu at 415 V (KA rms) Ics =100% ,IEC 60947-2 Adjustable thermal and fixed magnetic setting ,frame LS type,Front Face,Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB/L&T/Havells -1 No.(C) Capacitor 100 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 01 No, 10 KVAR x 01 No, 20 KVAR x 04 Nos), square type capacitor heavy duty rated, capacitor bankof rated 440 volt , 3 phase, Maximum over current: 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%,Maximum permissible over current(with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h,of rated 440 volt with detuned Reactor of de-tuning factor (P) 7% and suitable output of 100 KVAr at 440 volt suitable output , Overheating protection by thermostatconfirming toIS-13340-1993/, 13341-1992 & IEC -60831-1+2. .Make:- Schneider/ Siemens / ABB/L&T/Havells.(D)Intelligent Power factor controller relay 8 steps, seven segment LED Display, Augiliary power factor, Algotitham, Dual password protection 4 digit display, Alarm Indication on Display switching time programmable IS to 1809, 90V - 550V 50/60Hz 1A/5A with RS485 Make:- Schneider/ Siemens / ABB/L&T/Havells-01 No(E) SPMCB ,C-Curve, Control Circuit, .Make:- Schneider/ Siemens / ABB/L&T/Havells(F) CT 250/5A , 10 V.A,CL:1.0,Resin Cast ,CT Secondary wire Size should be 2.5 Sq mm.Make : Kalpa /AE/ L&T/Kappa -03 Nos(G)Accessories for 100 KVAR capacitor Bank :-(1)Capacitor Duty Contactor (3 KVAR-02 Nos, 5 KVAR - 01 No, 12.5 KVAR- 01 No, 25 KVAR - 04 Nos) 440 volt with damping resistors which limit inrush Current,440 volt ,3ph,50 Hz, Coil-220 Vac, .Make:- Schneider/ Siemens / ABB/L&T/Havells(2) MCB TPN 10 Amp, 10 KA, 240 Volt(3) MCB TPN 16 to 25 Amp, 10 KA, 240 Volt(4)Digital Voltmeter of size 96x96mm (0-500V) with built in selector switch.(5)Digital Ammeter of size 96x96mm (0-400A) with built in selector switch. (6)Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability - 01Set(H) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (J) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel Note: APFC Panel shall be manufacturedby original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. 9 Supply , installation, testing and commissioning and testing of power factor improvement panel of capacity 150 KVAR size of panel 1175 mm x 800 mm x 540 mm, fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel,factory made, weather proof , dust and vermin proof (IP 65) suitable forHumidity: up to 95%,Average daily temperature: +35°C max,Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle ironlegs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copperNYVIN cable of suitable size and PVC flexible conduit medium quality as required , comprising of the following:-(A) Insulated Bus bar of aluminium of 250 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue Colour, Bus bar support should be of SMC/DMC, Rated Impulse Withstand Voltage 8KV -01 Set 10 ( B) Incommer MCCB 320 Amp , three pole, short circuit breaking capacity 36 KA Icu at 415 V (KA rms) Ics =100% ,IEC 60947-2 Adjustable thermal and fixed magnetic setting ,frame LS type,Front Face,Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB/L&T/Havells -1 No.(C) Capacitor 100 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 02 No, 10 KVAR x 01 No, 25 KVAR x 01, 50 KVAR x 02 Nos), square type capacitor heavy duty rated, capacitor bankof rated 440 volt , 3 phase, Maximum over current: 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%,Maximum permissible over current(with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h,of rated 440 volt with detuned Reactor of de-tuning factor (P) 7% and suitable ouput of 100 KVAr at 440 volt suitable output , Overheating protection by thermostatconfirming toIS-13340-1993/, 13341-1992 & IEC -60831-1+2. Make:- Schneider/ Siemens / ABB/L&T/Havells(D)Intelligent Power factor controller relay 8 steps, seven segment LED Display, Augiliary power factor, Algotitham, Dual password protection 4 digit display, Alarm Indication on Display switching time programmable IS to 1809, 90V - 550V 50/60Hz 1A/5A with RS485 Make:- Schneider/ Siemens / ABB/L&T/Havells-01 No(E)SPMCB ,C-Curve, Control Circuit, .Make:- Schneider/ Siemens / ABB/L&T/Havells(F)CT 250/5A , 10 V.A,CL:1.0,Resin Cast ,CT Secondary wire Size should be 2.5 Sq mm.Make : Kalpa /AE/ L&T/Kappa -03 Nos(G)Accessories for 150 KVAR capacitor Bank :-(1) Capacitor Duty Contactor (3 KVAR-02 Nos, 5 KVAR - 01 No, 12.5 KVAR- 01 No, 25 KVAR - 01, 50 KVAR x 02 Nos) 440 volt with damping resistors which limit inrush Current,440 volt ,3ph,50 Hz, Coil-220 Vac, .Make:- Schneider/ Siemens / ABB/L&T/Havells(2) MCB TPN 10 Amp, 10 KA, 240 Volt(3)MCB TPN 16 to 25 Amp, 10 KA, 240 Volt, MCB TPN 40 Amp, 10 KA, 240 Volts(4)Digital Voltmeter of size 96x96mm (0-500V) with built in selector switch.(5)Digital Ammeter of size 96x96mm (0-400A) with built in selector switch. (6)Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability - 01Set(H) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (J) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel Note: APFC Panel shall be manufacturedby original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. 11 Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etcgetting out in soft/ loose soil and levelling of bottom surface to required level complete and as directed. 12 Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete and as directed. 13 Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engineer-in-charge. 14 Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 10cm depthcomplete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose. 15 M&L brick, sub class B bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed 16 Material & labour for cutting /boringto plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable forgivingmechanical protection to cable complete all as directed.(Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site and all as directed by Engineer-in-charge. 17 M&L in replacement to GI tubing light grade 80 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified and directed. (Make: Tata or Jindal or Swastic) 18 Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 70 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items herein before. 19 Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 50 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items herein 20 Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 35 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items herein 21 Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 4 core 25 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items herein 22 Supply and fixing Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 400 Amps, Rated Ultimate Shortcircuit Breaking Capacity 36 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=100% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. 23 S&F of On load change over switch capacity 400 Amp, 4 pole, 415 V, , Size FR4, Type CO4-400,site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge. 24 M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth leadusing GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. 25 M & L Painting to existing steelpole structure of 09 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above painting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and as directed.Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate. 26 M & L Painting to existing steel four pole structure of 11 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above painting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and as directed.Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate. 27 M&L for painting to steel structure/ fancing (both side wall)/ gate / board etc in any size/ make / thickness etc with MS fittings such as cross arms, clamps, pipe channel, bracing / wire mesh fencing ( both side will be considered as one unit) installation board etcafter removing ,scraping cleaning etc to old paint using shyenthic enamel paintapplying two coat (one as finishing ) over one coat of red primer oxided by paint spray gun includingmarking/ writtenindication sign/ words in diffrent colour etc complete all as site required and directed. Note :Paint colour shall be approved by Engr-in-Charge. 28 Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix B to Particular specifications as approved by AGE (I) AF manauri if not mentioned in BOQ.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail