}

Tender For Provision Of Certain Minor Works At Lgj Mil Station., Ganganagar-Rajasthan

Tender Notice

51591262
Tender For Provision Of Certain Minor Works At Lgj Mil Station.
Tender
Indian
Rajasthan
Ganganagar
25-10-2025

Tender Details

Tender For Provision Of Certain Minor Works At Lgj Mil Station.; 1 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. 2 Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge. 3 Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. 4 M&L for old size brick workstraight or curved any radiusbuilt in cement mortar (1:4) all as specified & directed. 5 M&L fly ash brick work with sub class B brick straight or curved on plan any radius half brick thick wall, built in CM 1:4 complete all complete and as specifed and directed. 6 M&L for 40mm thick damp proof course in cement concrete 1:2:4, type B-0, 12.5 mm graded stone aggregateto horizontal or vertical surfaces including necessary formwork complete all as specfied and directed by Engr-in-Charge. 7 M&L for reinforced cement concrete type B1 1:2:4 using 20mm graded stone aggregate inlintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, copings, bed plates,and the like including weathering, slightly rounded or chamfered angles and throating,incl formwork all as specified & directed.Note :- Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. 8 M & L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc 9 M & L for Formwork to fair finished surfaces soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed by Engineer-in- charge. 10 Formwork to edges of concreteflats, treads, breaks in floors,window cills, concrete railings, openings in concretewalls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similarwork exc 10cm but n exc 20cmwide complete all as specified and directed by Engr-in-charge. 11 Material and labour for reinforced cement concrete (1:1.5:3) type A-1 nominal mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. 12 M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified 13 S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 14 S&F for TMT bars5 mm dia over upto including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 15 Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed. 16 Removing excavated material to a distance exc 1.5 km but n exc 1.5 km and depositing where directed 17 M&L for sand filling in floors or in foundations including watering and consolidation all specified and directed 18 M&L for reinforced cement concrete type 1:1.5:3 using 20mm graded stone aggregate inchullah hoods, stairways (except sprial staircases) including steps (Square or spandril) string pieces, carriages etc complete any section straight or winding but excluding landing, RCC water tanks upto 1500 litres complete all as specified and directed by Engr-in-Charge. Note :- Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. 19 M&L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge 20 M & L 75 mm thick cement concrete typeB2 1:2:4 using (40mm graded stone aggregate) as in hard standing finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. 21 M&L for 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floor all specified and directed. 22 M&L for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as infloor all specified and directed. 23 Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.36 sqm but not exceeding 0.75 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. 24 Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 1200 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified.Note : Dado should be flushed with the wall plastering. 25 M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified.(Note : Punned thickness shall be considered for payment purpose) 26 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and over 20 mm thick screed bed in CM 1 : 6 complete all as specified and directed by Engneer -in-Charge 27 M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed. 28 M&L for 10 mm thick rendering on brick work or concrete surface in cement mortar1:6 on wall finished even and smoothe without using extra cement all as specifiedand as directed by Engineer-in-Charge. 29 M&L 15 mm thick cement plaster in CM 1:6 mixed with liquid WPC as per manufacturers instructions finished even and fair on fair surfaces of concrete / brick walls complete all as specified and as directed by Engineer-in-Charge. Note : WPC shall be measured and paid for separately under relevant item as supplying only. 30 M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling finish even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 31 Supply only Liquidwater proofing compound ISI marked confirming to IS 2645 - 2003. 32 M&L for preparation and applying three coat of white wash on newly plastered surface of wallwith one kg of unslaked lime mixed with 4.00 ltr of water to make thin cream, screened after 24 hrs and mixing on kg of gum desolved in hot water per one cum of cream, 1.30 Kg of sodium cloride/10 Kg of lime and untramine @ 3.0 grms/Kg of limecomplete all as specified and as directed by Engineer-in-Charge. 33 M&L for preparation and applying three coat of white wash on newly plastered surface of ceiling with one kg of unslaked lime mixed with 4.00 ltr of water to make thin cream, screened after 24 hrs and mixing on kg of gum desolved in hot water per one cum of cream, 1.30 Kg of sodium cloride/10 Kg of lime and untramine @ 3.0 grms/Kg of limecomplete all as specified and as directed by Engineer-in-Charge. 34 M&L for preparation ofnew plasteredsurface of walls and applying two coats of cement base paintcomplete all as specified & directed 35 S&F steel ventilator with top hung shutter incl hinges, handle, steel peg stay complete all as specified and directed by Engineer-in-Charge 36 M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer andtwo coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified. 37 S & F 4 mm thickfigured glass, pin head secured with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. 38 Supply and fixing of Fibre glass Reinforced plastic (FRP)door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick includinglaminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specifiedand as directed by Engineer-in- charge. 39 Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour andmade with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge. 40 S&F for Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of 35 mmthick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. including supply and fixing following items :-(a)Stainless steel (304 Grade) Finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked.(b)Stainless stell (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833.(c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d)Stainless steel (304 Grad) finished siliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e)Stainless steel (304 Grade) Finished Floor door stoper-1 Nos per leaf. 41 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) 42 S & F in repair 12 mm thick toughened glass with etching ( engraving pictures,names of figures of any type or any size) for glazed door fixed inculding aluminium frame wth necessary washer and locking arrangement, floor door hydroulic spring, stay peg, hinges, fixed filps, rubber gasket etc includign stainless steel locking arrangement, 250 mm stailess steel decorative door handle both side with all accessories complete all as speccified & directed by Engineer-in-Charge 43 S & F in repair vitrieous china EWC cascade type white including cistern, seat cover, inlet accessories connection to drain (or outgoing piep) and to flushing pipe, antisyphonage pipe etc., all as complete all as specified & directed by Engineer-in-charge 44 S & F 10 mm toughened polish glass for urinal partition complete all as specified & directed by Engr-in- Charge 45 S & F for hand soap dispenser wall mounted fancy type complete all as specified and directed by Engineer-in-Charge 46 S&F in repairs Toilet paper Holder stainless steel with flat recessed type finish glossy fixed to walls with chromium plated (CP) brass screwscomplete all as specified and directed. 47 S&F in repair brass CP platedhealth faucet with 1 mtr tube & hookcomplete all as specified and directed by Engneer -in-Charge 48 S&F in repair stainless steel chromium plated jet spray (butter fly or L bend) suitable for EWC including 1m tube and necessary nut bolts complete all as specified and as directed by Engineer-in-charge. 49 S & F 8 mm looking mirror of selected quality with bevelled edge mounted on stainless steel studcomplete all as specified and directed by Engr-in-charge. 50 S&F 100 mm long butt hinge, extruded stainless steel with stain less steel hing pin, complete all as specified and directed by Engneer -in-Charge . 51 S & F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed. 52 S & F 150 mm long Aluminum anodised bow handle fabricated type extruded section complete all as specified and directed. 53 S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot restsbut including CI P trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge. 54 S & F in repairs Vitreous China urinals, half stall type, white with grating & union including spreader complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2,securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;grating and Union for discharge pipe complete all as specified and directed. 55 S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm,including 32mm dia chromium plated waste coupling, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified . 56 S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacitylow level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed. 57 S&F in repair 15mm bore Pillar taps/swan neck tap chromium plated cast copper alloy with capstan heads, screwed down, high pressure with or without catered Hot or Cold with long screwed sheuks and flynuts, screwed for iron pipe complete all as specified and directed by Engneer -in-Charge Note : Min weight of tap should be as per SSR Part-I 58 S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. 59 S&F in repair CP brass stop/angle valvefancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge. 60 Supply & fixing450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge. 61 Supply and fixing600mm x 450mm size bevelled edge looking mirror , selected quality, 5mm thick glass, mounted on 6mm thick commercial ply back and aluminium channel, fixed to PVC plug with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge. 62 S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges. 63 S&F 15 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceiling complete all as specified and directed by Engneer -in-Charge 64 All as per item No 63 above but 20 mm dia pipecomplete all as specified and directed by Engneer -in-Charge . 65 S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed 66 S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors all as directed. 67 S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors all as directed. 68 S & F in repair 110 mm bore PVC (SWR) bends any radius complete all as specified and directed by Engneer -in-Charge . 69 S & F in repair 75 mm bore PVC (SWR) bend with access door any radius complete all as specified and directed by Engneer -in-Charge . 70 S&7 F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door any radius all as directed 71 S & F for PVC (SWR) vent cowl 110 mm dia complete all as specified and directed by Engineer-in-Charge. 72 S&F in repair PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed. 73 M&L in repair PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement all as specified and directed. 74 S&F 500 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed. 75 M&L for PCC 1:2:4 type B2 using40mm graded aggregates as in benching / haunching ofmanholes including forming channels including necessary formwork etc complete all as specified and directed by Engr-in-charge. 76 M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge. 77 Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm dieameter drain pipes as per IS-16098 (Part-II), Laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge 78 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into and including 25 mm thick sand bedding layer (Fazilka sand) through vibratory compa ction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-in-charge. 79 E/M PortionM&L for concealed Point wiringfor One light, one way switchcontrolled by one, oneway switch with single core PVC insulate, unsheathed multistranded copper conductorcable of size 2.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit20 mm dia concealed on wall/ceiling/floorincluding PVC insulated unsheathed earth wire with multi stranded copper conductor of size 2.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws with washercomplete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering andpaintingto match with the existing colour. 80 All as per srl item No 79 above, but for ceilling/exhaust fan paint controlled by one switch and regulator complete all as specified and as directed. 81 All as per srl item No 79 above, but for3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed. 82 All as per srl item No 79 above, but for3 pin 5 Amp socket outlet on the independent board with other switch, sockets complete all as specified and as directed. 83 All as per srl item No 79 above, but wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 4 Sq mm for 15 amps power point all as specified 84 Supply and fixed modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. 85 Supply and fixed modular Socket outlet multipurpose type 2 in 1, 3 pin,6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. 86 Supply & fix batton integrated LED light fitting 1 x 10 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed including taking down old one. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80 87 Supply & fix batton integrated LED light fitting 1 x20 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed including taking down old one. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80 88 Supply and fix piano type, 230/250 Volts grade on top covers, Modular switch 1 way 6 A, 1 module complete all as specified and as directed. 89 Supply and fixed modular Socket outlet multipurpose type 2in 1, 3 Pin 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. 90 Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge. 91 Supply and fixing ventilating Air fresher Fan of size 300mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge.Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 92 M & L for alluminum service wire of 4 Sqmm 2 core complete all as specified and directed by Engr-In-Charge 93 Supplying and laying,factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. 94 Laying only burnt bricks (old Size) retrieved from item No 95, 96 and 97 laid in trenches as cable protection complete all as specified and directed. 95 Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 35Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.. 96 Supply, laying, testing XLPE LT cable size 16 sqmm 4.0 core,1100 volts grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendment laid in trenches/fixed to wall/pole/laid in floor includign necessary connections and suitable size of thimbingcomplete all as specified and directed by Engineer-in-Charge. 97 Supply and fixing 1.5 Sqmm two core PVC insulated unsheathed multistranded copper conduductor calbe 1100 volts grade including PVC conduit of 2 mm thicknesscompleted all as specified and directed by Engineer-in-charge 98 Supply and fixing 250V, 10KA C curve miniature circuit breaker (MCB), 6 to 32 Amps fixed in existing PVC box including connecting complete all as specified and directed by Engr-In-Charge 99 Supply and fixing in repair LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swiveling cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mmx 20mm x 3mm, 4 Nos mounted on PVC insulator andprovision of incoming/outgoing cables with gland, including in built 6Amp MCB, SP, 9/10KAone No complete all as specified and as directed by Engineer-in-charge. Make :- Hensel Cat part No. K9350 or equivalent in Sintex/Sagar Frp Industries Gurgaon. 100 Supply and fixing LED flood light fittings with and including lamp 150 W rating, separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only,IP Protection not less than IP 66, Protection should be Class I,Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminarieswith separate external surge protection device 4 Kv to 10 kv rating and separate connector block for termination of incoming cable connectionall as specified and directed. Make- Crompton/Bajaj/Halonix 101 Supply and fixing energy efficient LED security light fitting of 60 W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 102 Supply and errecting in repair prestressed cement concrete poles 9 meters long of cross section (102 mm x 152 mm) at top and (102 mm x 289 mm) at bottom class-10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer balck and white strips 30 cm wide each (05 Nos) yp to 1.5 mtrs height from coping & numbering of poles complete all as specified and directed.Note : Excavation, earthwork and PCC shall be measured and paid separately under respective item of BOQ 103 M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in coping of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. ( Volume of poles/struts embedded in concrete shall be deducted. ) 104 M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundationof electric poles/struts etc including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed. Note :Volume of poles/struts embedded in concrete shall be deducted. 105 M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in coping for electric poles or for stay assy etc. complete all as specified and as directed by Engr-in-Charge. 106 M&L in replacement for 40mm bore GI pipe light grade with all fittings and fixtures fixed to pole and laid to floor/ground for mechanical protection of cable strip all as specified and directed 107 Supply and fixing of brackets made out of GI tubing light grade 40 mm dia 1.5 to 2.5 meter long bent to shape at 120 degree angle at half meter from bottom (as per sample) fixing on poles/walls for street light fitting including before fixing applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.Note : Clamps and nut bolts for fixing as required shall be deemed to be inclusive in quoted rates. 108 Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 2 way with 200 Amps rated busbarflush/surface mounting double door complete all as specified and directed 109 Supply and fix in repair isolator single pole and neutral 40 Amps 240 volt 50 Hz complete all as specified and directed 110 M&L 25 mm GI pipe medium grade, ISI marked including all tube fittins with screwed and socked joints fixed to walls, ceilling or under floors etccomplete all as specified and directed 111 Supply & laying GI tubes medium grade with all fitings hot water pipe duly insulated with glass wool laid in of size 20 mm bore complete all as specified and directed 112 S&Fbib tap 15mm bore cast copper alloy chromium plated long bodywith capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. 113 Supply and fix wiring for circuit/submain wiring alongwith earth wire the following sizes fo FRLSH PVC insulated copper conductor single core cable in PVC conduit in surface or concealed in walls of 2 runs of 4.0 Sqmm +1run of 4.0 sqmm as earth wire complete all as specified and directed by Engineer-in-Charge. 114 S&F 1000 ltrs capacity Rotational moulded polyethylene in white coloured double layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed. 115 M & L framed work fabricted with structural mild steel section, plates braces rails completed drilled and grounting including painting with anti corrosive primer and bituminious paint back in colour all as specified and directed by Engineer-in-charge 116 Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body with 3 level safety, capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet with feroglas coated (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for hot and cold water of suitable length, three core PVC insulated PVC Sheathed copper conductor flexible cable,including 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. 117 SupplyingInstall, test and commissioning of solar water heating system (Flat Plate Collector) based on indirect transfer of heat of capacity 500 Ltrs per day including backup stainless steel hot water tank suitable for inlet water with chlorine and fluoride content upto 100 PPM and comprising of solar flat plate collector, collector stand assembly, stainless steel insulated hot water storage tank with a heat exchanger of 500 Litres Per Day capacity with electric backup with collector A Size aluminium box collector comprising of following :- 118 (a) ISI Marked (IS-12933 Part-I)-1992 with amendment No. 1 & 2 solar flat plate collector, having outer nominal diameter of 1860 mm x 1240 mm & 110 mm material aluminium cast type channel and angle back covering covering 22 SWG aluminium sheet. Upper covering not less than 4 mm thick tempered/toughned glass absorber selectively coated copper fin and tubes, nominal fin size 0.2 mm thick x1716 mm length, tube size 24 SWG X 1270 MM ODX1721 Length, Insulation 50 mm thick mineral wool of 48 Gauage aluminium foil Gastets EPDMISPDM/Neoprene, Flanges 62 mm OD X 3 MM thick brass flanges header pipe 22 SWG X 25.4 MM OD X 1320 Length with following specifications:-2 Nos(i) Cover plate shall be toughned glass conforming to IS 12933(Part-1)1992 with amendment No.1 & 2,(ii) Collector box shall be made of Aluminium sheet, Type Grade, Size and finish of material used shall be as per IS12933 (Part-I) 1992 with amendment No.1 & 2.(iii) Sheet for absorver shall be made of copper type Grade, size and finish of material used shall be as per IS12933(Part-1) 1992 with amendment No.1 & 2.(iv) Absorver shall be made of copper type Grade, size and finish of material used shall be as per IS12933(Part-1) 1992 with amendment No.1 & 2.(v) Collector box insulation shall confirm IS12933(Part-2, Section V) 1992 with amendment No.1 & 2.(vi) Gaskets and Groutments shall confirm to IS12933(Part-2, Section VI) 1992 with amendment Not & 2. 119 (b) Insulated stainless steel Hot Water Storage tank non pressure type made of stainless steel grade 04 Cr 18 Ni or 07 Cr 18 NI of IS 1570(Part-3)-1985. TIG Welded of 500 Ltrs capacity, nonmagnetic tank with stainless steel Wigs with followig specifications -01 No shall beinsulated with 40 mm thermal grade PU Insulation with FRP Cladding Tank Stand assembly shall be made of Size 38 x 38 x 4 mm duly pretreated and stove enamelled with black colour paint.(c) Provisions of electrical back up with min 3 kw heating element including providing one No.25 Mips MCB 10 KA rupturingcapacity in sub main distribution board (Catered in Schedule of intemal electrificaion) and prviding electrical connection in rigid on metallic PVC concealed conduit with 4 Sqmm single core, straned copper conductor, PVC Insulated cable from outlet toMCB to electrical backup with connected accessories - One Job. The Solar Water Heating System shall be provided on roof of single /double storey building. The electrical back up connectrion shall be tapped from submain board provided at ground f l oor. 120 (d) Heat Exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 18 NI or 0718 NI of IS 1570 (Part-2) 1885(e) All other pipe/civil work, steel staging work for PVC Tank, electrical work, outlet and inlet thermometer, Airrelease valves, check valves, gate valves, controls and instruments etc all as required shall be deemed to be included in unit rate quoted bythe contractor for this item. System internal piping shall be ISI Marked GI Pipe medium class of IS : 1239 duly insulated with 50 mm thick rock wool of 48 Ka/M3 density and 26 SWG AI Cladding. 121 Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule A/BOQ

Key Value

Document Fees
INR 500 /-
Tender Value
INR 21.01 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail