| 1 | Providing services for operation of electric driven pump sets including its periodical maintenance in three shift per day with one operator (FGM)per shift for 08 hrs from 0600 to 1400, 1400 hrs 2200 hrs and 2200hrs to 0600 hrsfor the following type / capacity of pump sets all as specified & all as per details given in particular specifications :-(a)Raw Water Pump House.(i) Centrifugal Pump 30 HP capacity (No of Pump set - 03 No\"s) Make - Beacon(ii)Centrifugal Pump 25 HP capacity (No of Pump set - 01 No).Make - Kirloskar.(b)MID Pump house(i)Non clog centrifugal pump set of BEST & 20 HP crompton engineering pump. (No of Pump Set - 02 Sets)(ii)Non clog centrifugal pump 7.5 HP capacity.Make - Kirloskar (No of Pump - 01 Set). (c) Leakage water pump set(i) Submersibble pump set 10 HP cap Make: Kirloskar (No of Pump - 04 No\"s)including2 x 20 HP pump sets at old dam pump house as required including cleaning of the pumps/motors, pump room electrical panel etc, opening and closing sluice valves as reqd, starting the pump set and filling raw water in the UG sump of new dam or static tank of main fire station as directed by including maintaining standard log sheet complete all as specified and as directed.Note:(i) Rates quoted shalll be deemed t include the cost of minor spares not catered for in the subject CA.(ii)New material/stores provided for completing the job shall be measured and paid for separately under relevant items of sch \"A\" .(iii)Contractor shall provide the all type ofT& P,ladder and safety items for attending and rectification of the complaints. |
| 2 | Providing services for operation and maint ofmain Filteration plant near clear water pump housealong with electrical panel board (starters) and chlorination plant including their periodical maintenance, repairs, adding chemicalsby employing three shift per day with one operator (FGM) per shift for 08 hrs from 0600 to 1400, 1400 hrs to2200 hrs and 2200 hrs to 0600 hrs complete all as specified and as directed consisting of the following:-sand filter, NRVs, sluice valves etc and compressor unit complete.(a) Chlorination plant, cylinder mounted type, Vaccum operated complete with injection assembly, booster monoblock pump set including mixing chamber control valves, 3 No\"s & 1 No chlorine gas cylinder 100 Kg capacity complete.(b)Air compressor, LT panel board suitable for 3 phase, 415 volt supply, wall mounted with 200 Amps MCCB incoming and MCBS in outgoing or 97.5 CFM pressure 0.35 Kg per cum driven by 5 HP induction electric motor, 3 phase, 415 Volts, 50 Hz including DOL starter 1 No Rotary type (c) Electrical control panel board with starter, switches, MCB. (d)Alum dosing tank of FRP material, 8 gallons capacity with manual mixing arrangement inlet & outlet connection 1 No including servicing complete for proper functioning complete all as specified and as directed.(e) Regular washout filtration, proper cleaning and refill it for further use. |
| 3 | Providing services for operation and maint offilteration plant at NSBpump housealong with electrical panel board (starters) and chlorination plant including their periodical maintenance, repairs, adding chemicalsby employing one shift per day with one operator (FGM) per shift for 08 hrs from 0600 hrs to 1000 hrs, 1700 hrs to 2100 hrs complete all as specified and as directed consisting of the following:-presssure filter, NRVs, sluice valves etc and compressor unit complete. (a) Chlorination plant, cylinder mounted type, Vaccum operated complete with injection assembly, booster monoblock pump set including mixing chamber control valves, 3 No\"s & 1 No chlorine gas cylinder 100 Kg capacity complete.(b)Air compressor, LT panel board suitable for 3 phase, 415 volt supply, wall mounted with 200 Amps MCCB incoming and MCBS in outgoingor 97.5 CFM pressure 0.35 Kg per cum driven by 5 HP induction electric motor, 3 phase, 415 Volts, 50 Hz including DOL starter 1 No Rotary type Make - Candy. (c) Electrical control panel board with starter, switches, MCB. (d)Alum dosing tank of FRP material, 8 gallons capacity with manual mixing arrangement inlet & outlet connection 1 No including servicing complete for proper functioning complete all as specified and as directed Engineer-in-Charge.(e) Regular washout filteration sand filter ,proper cleaning and refill it for further use. |
| 4 | Providing services for operation of Valve Opening (Water Distribution) in the Rajendra Nagar Area also its periodical maintenance including cleaning and repairing of all leakages for Valves all as directed with one operator (Valveman) per Shift for Two Shifts (First Shift from 0500 hrs to 1300 hrs, Second Shift 1700 hrs to 0100 hrs)for following type/capacity of OHT & Valves all as specified and as per detail given in particulars in specifications. (a) Rajendra Nagar OHTscada valve panel and manual valves - 03 Each (manual & scada valves - 150/200mm)(b)Victualing OHT scada valve panel and manual valves - 03 Each (manual & scada valves - 150/200mm)s(c) Fire OHT scada valve panel and manual valves - 03 Each (manual & scada valves - 150/200mm)(d) Kasturi scada valve panel and manual valves - 04 Each (manual & scada valves - 150/200 mm)(e) Barrack Area scada valve panel and manual valves - 03 Each (manual & scada valves - 150/200mm)(f) I No (Near DAG Wing) direct supply valve - 150 mm - 1 Nos(g) Wash Out Valve - 150 mm - 1 Nos(h) Krishna Block (Near SMW) direct supply valve - 100 mm - 1 NosRajendra Nagar Sump cum Pump House.valve opening for dukes nose watch tower from sump cum pump house with submersiblePump sets- 02 No\"s-32 mtr head 9.5 lps,with suitable induction motor 2900 rpm,5 HP ,3 ph. |
| 5 | Providing services for operation of Valve Opening (Water Distribution) in the Pratap nagarArea also its periodical maintenance including cleaning and repairing of all leakages for Valves all as directed by appointing one operators (Valvemen) for operating the valves four hours in the morning (04 AM to 08 AM) and same operators for four hours in the evening (04 PM to 08 PM)for followinglocations type/capacity of OHT & Valves all as specified and as per detail given in perticulars in specifications .(a) Boson store/ barrack area bypass supply line valves size 150mm diasluice valve(b) SMQ area supply line valves and OHT valves size 150/200 mm dia sluice valve.(c) Kasturiareasupply line vales and OHT valves size 200 mm dia sluice valve.(d) Pratap nagar supply lines valves and OHT valves size 150/200 dia sluice valve. |
| 6 | Providing services for operation including periodical maintenance of central hot water plant in single sailors living accomodation at locations Indrayani,Betwa/Gomti,Ganga,Brahmaputra Hot Water Plants by appointing two operators (one operator at two locations) (FGM) for operating the plant four hours in the morning (04 AM to 08 AM) and same operators for four hours in the evening (04 PM to 08 PM)by first opening the incoming water, then firing the boiler, with the help of pump, pumping the hot water received in the calerifiero to each bath room :-Note :- Diesel shall be issued under Sch \"B\" free for use as and when required.Note:(i) Rates quoted shalll be deemed t include the cost of minor spares not catered for in the subject CA.(ii)New material/stores provided for completing the job shall be measured and paid for separately under relevant items of sch \"A\" .(iii)Contractor shall provide the all type ofT& P,ladder and safety items for attending and rectification of the complaints.Note for Item no 1 to 61. Contractor should provide safety shoes,one pair of uniform,helmet,safety glasses &safety gloves ,travelling charges etc for each working operator2.Contractor should provide torch light,grass cutting blade,01 No .axe,first aid box etc for each plant.3. The Employed labours are wholely responsible forarea cleaning i.e grass removing, complete cleaining of plant rooms and other task given by JE/Engr In Charge. |
| 7 | M & L for complete removal of existing treatment on steel surfaces of 100 Kg chlorine gas cylinder and applying two coats of yellow synthetic enamel paint over one coat of red oxide primer complete all as specified and as directedEngineer-in-Charge. |
| 8 | S&F in replacement unserviceable plug with new dead end plug of mild steel suitable for 100 Kg chlorine gas cylinder complete all as specified and as directedEngineer-in-Charge. |
| 9 | S&F in replacement unserviceable cylinder cap with new cylinder cap of mild steel suitable for 100 Kg chlorine gas cylinder complete all as specified and as directedEngineer-in-Charge. |
| 10 | S&F in replacement unserviceable chlorine filter with new chlorine filter suitable for chlorine plant of capacity 200 to 400 gm/hr complete all as specified and as directedEngineer-in-Charge. |
| 11 | S&F in replacement unserviceable pressure reducing valve of brass with new pressure reducing valve suitable for chlorine plant of capacity 200 to 400 gm/hr complete all as specified and as directedEngineer-in-Charge. |
| 12 | S&F in replacement unserviceable copper pipe with new copper pipe of 10 mm dia with coupling at both ends of length 1.5 mtr complete all as specified and as directedEngineer-in-Charge. |
| 13 | S&F in replacement unserviceable valve seat of mild steel suitable for chlorine plant of cap 200 to 400 gm/hr complete all as specified and as directedEngineer-in-Charge. |
| 14 | Checking, servicing and repairing of Three No\"s chloronome plantsat clear water Pump House, Swimming Pool & AF Stn and Two Sodium Hypochlorite plant at clear water Pump House and NSB as and when required or as directed by JE IC, once for satisfactory functioning of all plants including replacement of minor unserviceable parts i.e. nut bolts, washers, teflon tape and cleaning of filter assembly complete all as specified and as directedEngineer-in-Charge. |
| 15 | M& L for cleaning of installation area by cutting the bushes and grassin surroundings complete all as specified and as directedEngineer-in-Charge. |
| 16 | Supply and fix in replacement of sliuce valve wheel operating cap inserting of nut bolt with 20 mm GI pipe length 4 mtr long with Tee rod for following Size 100mm, complete to operate valve in valve pit, including making hole in GI/MS sheet as required. |
| 17 | All as per item No 16 here-in-before Size 150mm. |
| 18 | All as per item No 16 here-in-before Size 200mm. |
| 19 | S&Fin replacement Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. cut to ordinary lengths i.e. within 20mm of the length indicated ( Fe-410-W(Gde-E-250) quality-A. |
| 20 | Disconnecting and taking down UNSV parts of Hot water plants after removing the cable connection fuses, relays replace the UNSV cables using 2.5 sqmm copper cable PVC insulated up to 1.5 mtr length, provide new pin type cable lugs and Supply and fix in replacement of following spare parts for hot water plants as per requirement to start and continuous running plant.RTD assembly, 63 mm long |
| 21 | Pressure gauge -1 to + 5 Kg/CM2, D 100, 3/8\" BSP, BT |
| 22 | Safety wall 25 mm 150 to 250 PSI |
| 23 | Capacitor |
| 24 | Photo resistor |
| 25 | Needle Valve 3/8\" BSPT(F) |
| 26 | Nozzle 5 GPH, 60 DEG PLP, MONARCH |