| 1 | Supply, Installation, Testing and Commissioning of below mentioned items and equipments |
| 2 | Addressable fire alarm panel for fire protection system. FPA-2000-PWM |
| 3 | Microprocessor Based Repeater Panel FPE-8000-FMR |
| 4 | Supply, Installation, Testing and Commissioning of Flameproof Manual Call Point Module |
| 5 | DV Flameproof Manual Call Point |
| 6 | Fire Pump Room |
| 7 | Office Block |
| 8 | PMCC |
| 9 | Electrical Siren including panel |
| 10 | Signal Module |
| 11 | Relay Control Module |
| 12 | Supply, Installation, Testing and Commissioning of Deluge Valve Auto Motion system |
| 13 | Signal Module (Low Air Pressure Module) |
| 14 | Signal Module (Fire signal Module) |
| 15 | DV Open signal Module FLM-420-01I1E |
| 16 | Supply, Installation, Testing and Commissioning of Trippingsystem |
| 17 | Relay Control Module for PMCC |
| 18 | Relay Control Module for Master ROV |
| 19 | Relay Control Module for Siren |
| 20 | Supply, Installation, Testing and Commissioning of Fire Pump House signal module |
| 21 | Engine Running |
| 22 | Jockey Pump Running |
| 23 | Main Header High Pressure |
| 24 | Main Header Low Pressure |
| 25 | Air Tank Low Pressure |
| 26 | Air Tank High Pressure |
| 27 | Wetherproof Pressure Switch |
| 28 | Supply, Installation, Testing and Commissioning of Batteries, FLP JBs and solenoid valves |
| 29 | Batteries 7AHX12Volts |
| 30 | Fire Engine Batteries 150 AH, 12 Volt |
| 31 | FLP Box with internal dimension 300x300x125having2x0.75\"ET enteriesforicand6x0.75\"entries |
| 32 | FLP Box with internal dimension 125diax65mm having 2x0.75\"entries |
| 33 | Weather proof junction box with internal dimension 125diax65mm having 2x0.75\"entries |
| 34 | Flameproof Solenoid Valve |
| 35 | Supply, Installation, Testing and Commissioning of various Panels and related cables, glands, structures, HSD day tank, piping etc. |
| 36 | FIRE ENGINE CONTROL PANEL |
| 37 | BATTERY CHANGE OUER SWITCH DCWITH BATTERY WIRE & TERMINATION |
| 38 | ITC FIRE ENGINE CONTROL PANEL |
| 39 | JOCKEY PUMP CONTROL PANEL5.5kw/7.5HP |
| 40 | Cable Gland for Jockey Pump & Security Air Compressor Panel |
| 41 | ITC JOCKEY PUMP CONTROL PANEL 5.5kw/7.5HP Aoutmation And Power Cable Connection |
| 42 | SECURITY AIR COMPRESSOR CONTROL PANEL 5.5kw/7.5HP |
| 43 | Cable for Control Panel to Engine 12C 1.5 sqmm |
| 44 | Gland for 12 C 1.5 Sq. mm cable |
| 45 | Structures for Panels |
| 46 | Day Tank for HSD (Cap: 200 Ltr.) |
| 47 | Piping from Day Tank to Engines |
| 48 | Supply, Installation, Testing and Commissioning of Vapour Extraction System including all accessories (Considering 1 blower and 1 no. 15 HP motor) |
| 49 | Design, fabrication and supply of centrifugal blower of capacity 12500 m3/hr (7350cfm) at170mm WCSP to be direct driven with base frame by a flameproof motor confirming to MSclass II construction with Backward curved impeller duly painted with epoxy paints and guardsfabricated by GI sheet to be provided for Motor. |
| 50 | Supply of Flameproof Motor of 15HP 1440 RPM suitable for 410/440 V, 3-Phase, 50Hzm A.C.supply confirming to IS-325 per 1970 for electrical design and have class B insulation suitablefor continuous duty, enclosure confirming to group IIA, IIB, gases as per IS-2148 terminalarrangements of the motor fitted in sealed box with Test Certificates from manufacturers andCMRS Make Kirloskar/Bharat Bijlee/Crompton Greaves/ GEC etc. |
| 51 | Supply and installation of Flame Proof Push Button Control System for the above Motor. |
| 52 | Design, supply, fabrication, erection of round spiral ducting made of 20 gauge GI sheet to have air velocity of 12 mt/sec on the suction and discharge end of the blower with MS Angular Flanges for all ducts irrespective of size duly painted with two coats of enamel paint over two coats of metallic primer. Duct shall be supported with hangers of 25x25x6 mm MS Angle and all hardwares in GI with proper gaskets as per direction of site incharge. The job includes supply of reducer/expanders whereever required and measured with ducting. The cost of fabrication of hangers shall be madeas per rate given in seprate item. The cost of other hardwares, gaskets etc. required for ducting is inclusive in this item rate. |
| 53 | Supply, fabrication and erection of Multyvane Dampers at the blower inlet and outlet to isolate the blower. |
| 54 | Supply, fabrication and erection of Suction Hoods fabricated out of 22 gauge GI/ms sheet. |
| 55 | Supply, fabrication and erection for making flexible connection to the inlet of blower. |
| 56 | Supplying and installation of U-type manometer as per specifications |
| 57 | Design,Supply, fabrication and erection of 550mm dia Chimney (height approx 11m) and stack made out of 3mm MS sheet for above blower exhaust alongwith weather cowl and bird screen. The height of Chimney shall be 3.00 mt above the shed roof. The rate shall include cost for providing anchoring of Chimney / stack with proper structural support considering self weight and wind pressure.The Chimney / stack shall be painted with two coats of primer and 2 coats of enamel paint. |
| 58 | Supply, fabrication & installation of structral steel supports/hangers of required sizes for ducts and hoods and also any other structures alongwith painting with two coats of primer and 2 coats of enamel paint as per direction of site incharge. |
| 59 | Assembling, positioning, erecting and commissioning of Centrifugal Blower with motor on constructed platform as per direction of site- incharge. |
| 60 | Construction of RCC foundation, steel structure, platform for installation of blower alongwith motor and Chimney / exhaust stack as per indicative enclosed drawing.Foundation shall be designed considering wind velocity, bearing capacity of soil as 10 t/sqm and load on account of blower alongwith motor and Chimney and stack. Thedesign of structure and foundation is in the scope of contractor and should be approved by Govt. Engg College/ NIT before executing job. The job includes supply ofall materials like cement, steel, ms structural required for structure including foundation bolts etc. Note: MS base shall be provided for both fan and motor built as an integral partand shall be mounted on RCC foundation as per design. |
| 61 | DG-25 KAV RPM-1500 VOLTS 415, 3PHASE AMPS BASE RATE (BR)35, PF 0.8. NOTE: MAXIMUM RUNNING HOURS ALLOWED 800 Hrs. |