| 1 | GENERAL SUMMARY |
| 2 | Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:- |
| 3 | (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/30/2025 Sheet No. 1/3, CWE/ARCH/30/2025 Sheet No. 2/3, CWE/ARCH/30/2025 Sheet No. 3/3 and Construction of 20 X Bathroom as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor. |
| 4 | Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule ‘A’Part- VII (Ref prepriced schedule attached seperately) |
| 10 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part- VIII (Ref prepriced schedule attached seperately) |
| 11 | SCH \"A\" Pt - IX (MISCELLANEOUS PARTS) |
| 12 | M & L for concealed point wiring for one light/bell or one ceiling fan/exhaust fan controlled by one one way switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 13 | M & L for concealed point wiring for one 3 pin/5 pin 5 Amps socket outlet on same board with other switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 14 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 15 | M & L for concealed point wiring for one switch 5/6 pin 5/15 Amps socket on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.50 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 16 | Supply and fixing LED lights fitting 1x 16W/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 17 | M&L Brick bats for laying in soak pit complete all as specified and directed. |