Tender For Periodical Services To Zone B Under Age Br I At Ins Shivaji Lonavla; 1 M&L for complete removal of old smoke, shoot,moulds,vegetation, moss and efflorescent salts and trading oil and greasy spots from surface areas using high-pressure water jet spray technology pressure (5000-10000)PSI , as part of surface preparation for repainting. by skilled labour complete all as directed by Engineer-in-Charge.Note-: Rates are inclusiveall scafoldings used for up to the height of 4 storeys. 2 M&L for complete removal of old plastered surfaces of walls, ceiling,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying 3 mm thick white cement based wall care putty on plastered surface of internal wall and ceiling smooth finish.etc of approved make & shade on walls and other places complete all as specified and as directedby Engineer-in-Charge.Note-: Rates are inclusiveall scafoldings used for up to the height of 4 storeys. 3 M&L for applying one coat of acrylic waterbased interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subbsequent coats up to 15M height all as directedby Engineer-in-Charge.Make Dr.fixit,Nerolac,Asian paint,Berger or Equivalent. 4 M&L forapplying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface up to 15M height complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make Dr.fixit,Nerolac,Asian paint,Berger or Equivalent. 5 M&L for Preparation of old plastered surfaces of walls,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface up to 15M height from ground level incldng removing and refixng wall paintngs boards and panels of any descripton complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.Make Dr.fixit,Nerolac,Asian paint,Berger or Equivalent. 6 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old wall surfaces with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint up to 15height complete all as directedby Engineer-in-Charge.Make Dr.fixit rain coat neo,Nerolac,Asian paint,Berger or Equivalent. 7 M&L for applying one coat water based premium acrylic smooth exterior emulsion over approved colourwith silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over and including one coat of exterior grade primer with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint up to 15height complete all as directedby Engineer-in-Charge.Make Dr.fixit rain coat neo,Nerolac,Asian paint,Berger or Equivalent. 8 M&L for Preparation of old plastered surfaces of walls,ceiling,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface up to 15M height from fgrond level complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. 9 All as per Ser Item No 4 here-in-before but on ceiling 10 All as per Ser Item No 8 here-in-before but one coat of cement base paint 11 M&L for preparation of old painted wood surfaces of any description having width/ girth execeeding 10cm and apply one coat of synthetic enamel paint complete all as specified & as directedby Engineer-in-Charge.Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys. 12 M&L for preparing old steel surfaces and apllying two coats of black bituminious anti corrosive paint of approved make including removing corrosion to give an even shade up to any height all as directed and specified.Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys. 13 M&L for obilatering old writing of any description, n exc 0.1 sq m, with paint to match existing work complete all as specified and as directedby Engineer-in-Charge. Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys. 14 M&L for writing letters or figures (Block, Roman, Italic or Indian) n exc 30 cm high complete all as specified and as directedby Engineer-in-Charge.Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys. 15 M&L for writing stops, commas, short lines, dashes, hyphens, brackets, etc complete all as specified and as directedby Engineer-in-Charge.Note for Sl item No 1 to 15 :-(i) Unit rate quoted shall include for necessary scaffolding, trestles, ladders & cradles required for execution of the work and protective works.(ii) Necessary spreading and removing coverings to doors, windows, floors, fittings etc to protect them from splashes and cleaning of the doors/windows and floors after carrying out painting shall be made by the contractor.(iii) Unit rate quoted shall be deemed to include for necessary shifting of tables,movable cupboards and other articles required for execution and placing in same position after completion of the work.(iv) Unit rate quoted shall also include for removing of nails, making good holes, cracks etc to match with the existing surfaces. Note-: Pricing are inclusiveall scafoldings used for up to the height of 4 storeys.(v) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer.(vi)The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.