| 1 | Cleaning of sewage lines including manholes of 150mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from near by living accn or as directed by Engineer-in-Charge and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit complete all as directed. |
| 2 | Cleaning of sewage lines including manholes of 200mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from nearby living accn or as directed by Engineer-in-Chargeand covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit complete all as directed. |
| 3 | De-watering of septic tanks and soakage wells by sewage pump air tight body hired by contractor and draining out the same out of Cantt area complete all as directed and to the entire satisfaction of Engr-in-Charge.Notes :(a)Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b)Any damage caused during cleaning shall be rectified tosatisfaction of Engr-in-Charge by the contractor without any extra cost. |
| 4 | Taking out sludge from septic tanks incuding inlet and outlet chambers, removing and depositing the sludge in a pit out of Cantt. area by means of moter pump covering the sludge in the pit with earth and finally spraying unslaked lime, dry, around the septic tank and over the pit complete all as directed Notes : (a)Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b)Any damage caused during cleaning shall be rectified tosatisfaction of Engr-in-Charge by the contractor without any extra cost. |
| 5 | Cleaning of blocked Bottle trap, WC-\"P\" trap/ \"S\" trap, Nahani trap, Kitchen-Gully trap etc upto 1st manhole and making the drain pipe of any size fully functional by flushing with water to entire satisfaction of Engr-in-Charge.Notes : (a)Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b)Any damage caused during cleaning shall be rectified tosatisfaction of Engr-in-Charge by the contractor without any extra cost. |
| 6 | Demolition of brick work including all quoins,pillars etc built in cementmortar complete all as specified and as directed |
| 7 | Material and labour for brick workwith sub class \"B\" bricks old size straight or curved on plan exceeding 6 m mean radius in cement mortar 1:4 complete all as specified and as directed |
| 8 | Material and labour for brick work (except brick) straight or curved on plan exc 6 m mean radius built in CM 1:6complete all as specified and directed. Note:- Serviceble Old bricks shall be reused after cleaning obtained from demolition. |
| 9 | Taking down cement plaster any thickness from walls of manholes and septic tanks including raking out joints, hacking for key scrubbing down with water and removal of debris etc complete all as specified and as directed |
| 10 | Material and labour for rendering 15mm thick ( 10+5 mm) in two layers on brick work or concrete surfaces, in chajjas/parapet walls etc in cemet mortar 1:4 mixed with liquid water proofing compound as per manufacturer\"s instructionsfinished even and fair complete all as specified and as directed. Note : Liquid WPC will be measured and paid separately. |
| 11 | Supply only integral liquid water proofing compound complete all as specified and as directed. |
| 12 | Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement cut as required to facilitate demolition ) complete all as specified and as directed |
| 13 | Material and labour for reinforcedcement concrete(1:2:4), type B-1 uising 20 mm gradedstone aggregate as in slab supported on walls, beams and columns in floors , roofs , balconies canopies , deck slabsand in shelvesand the like complete all as specified and as directed .Note:- Reinforcement and form work shall be measured and paid seperately |
| 14 | Material and labour forr inforcedcement concrete(1:2:4), type B-1 uising 20 mm gradedstone aggregate as in walls , retaining walls , basement walls , ballast walls and like any thickness above footing including attatched pilaster and buttress complete all as specified and as directed .Note:- Reinforcement and form work shall be measured and paid seperately |
| 15 | Material and labour for precast cement concrete(1:2:4), nominal mix, type B-1 uising 20 mm gradedstone aggregate as in cover slab of drain set in cm 1:4,\ including form work complete all as specified and as directed .Note:- Reinforcement shall be measured and paid seperately |
| 16 | Material and labour for TMTbar 10 mm dia and over, cut to length, bent to shape required including cranking, hooking endsand binding with and including mild steel (annealed) wire not less than 0.9 mm dia or securing with clips etc all as specified and directed |
| 17 | All as per serial item no.16 here-in-before but TMT bars 6 to 8 mm dia as in strippus,binders and binders etc complete all as specified and as directed. |
| 18 | Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; flat, not exceeding 200 mm thick (Horizontal or sloping) incuding side of cover slab for rough finished surface of concrete complete all as specified and as directed. |
| 19 | Material and labour for formwork to sides and soffits of floor or roof beams,beam haunching, girder, bressummers, lintels,cantilevers, shelves including supports,over hangs,etc also splayed between floors and beams etc(Horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 20 | Demolitionand breaking up 150 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) setin cement mortar complete all as specified and as directed. Note :- Excavationand earth work shall be measured & paid separately. |
| 21 | Demolitionand breaking up 300 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) setin cement mortar complete all as specified and as directed.Note :- Excavation and earth work shall be measured & paid separately. |
| 22 | Material and labour for cement concrete bed (1:4:8) typeD-2 using 40mm graded stone aggregate to drain pipe of 150 mm bore including packing under haunching against the side of pipe after they are laid and tested complete all as specified and as directed |
| 23 | Material and labourfor cement concrete bed (1:4: 8) type D-2 using 40mm graded stone aggregate to drain pipe of 300 mm bore including packing under haunching against the side of pipe after they are laid and tested complete all as specified and directed |
| 24 | Material and labour for 150 mm bore reinforced cement concrete pipes,class NP2 , laid in trenches jointed with CM 1:1 complete with collar and tested complete all as specified and as directedNote:- Excavation and work shall be measured & paid separately. |
| 25 | Material and labour for 300 mm bore reinforced cement concrete pipes,class NP2 , laid in trenches jointed with CM 1:1 complete with collar and tested complete all as specified and as directedNote:- Excavation and work shall be measured & paid separately |
| 26 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m deepfor foundations, laying of pipes etc and getting out in soft/loose soil all as specified and as directed |
| 27 | Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed |
| 28 | Removal of surplus soilto a distance exceeding 250m but not exceeding 500 m and depositingwhere directed at a level not exceeding1.5 metre above the starting point complete all as specifiedand directed |
| 29 | Demolition ofcement concrete (un reinforced ) in ground floors and pavings n. exc 15 cm thickness below or above ground level complete all as specified and as directed |
| 30 | Material and labour for cement concrete(1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregateas in foundations, filling and mass concrete complete all as specified and as directed. |
| 31 | Material and labour for cement concrete (1:2:4), type B-1 using 20mm graded mechanically crushed stone aggregateasin lintels up to 1.5m clear span , cills , steps seismic and other similar bands , plinth coarses , string coarses, lacing coarses, parapets , and railing up to 60 cm height coping kneelers apex stones, bed plates complete all as specified and as directed. |
| 32 | Material and labour cement concrete 1:3:6 type C-1 (using 20mm graded mechanically crushed stone aggregates) as in benching and chamfering& making channels etc, complete all as specified and as directed |
| 33 | Taking down eave gutters and rain water pipes ( any size or pattern), including all fittings,heads,shoes,bends,swan necks etc including cleaning of refixing or remova to store ( measured over allfittings and accessories) complete all as specified and as directed |
| 34 | Supply and fixing cast iron soil, waste and vent pipe,100mm bore, sand castin any length, with or without ears, with lead joints, fixed to walls with and including 50 x 5 mm thick flat iron stack clamps,and 16 mm dia round iron stays,including bolts and nuts securing ends of stay to wall or roofnuts , boltsetc. and making necessary connections, complete all as specified and as directed. |
| 35 | Supply and fixing cast iron soil, waste and vent pipe,100mm bore, sand castin any length, with or without ears, with lead joints, laid in trenches or floorand making necessary connections, complete all as specified and as directed. |
| 36 | Supply and fixing cast iron cowls for 100 mm bore cast iron pipecomplete all as specified and as directed. |
| 37 | Supply and fixing cast iron bends (any radius) for 100 mm bore cast iron pipe complete all as specified and as directed. |
| 38 | Supply and fixing cast iron junction double (doubleT) equal or unequal ,ordinary or inverted with spigot or socketbranch for 100mm bore cast iron pipe with access door complete all as specified. |
| 39 | Material and labour for cast iron Nahani trapdia of outlet 100 mm with grating including jointing to waste pipefixed in cement concrete (1:2:4) type B-1.complete all as specified and as directed. |
| 40 | Supply and fixing in repair vitreous Chinasquatting pan orissa pattern long pan size 580x440mm with‘P’ or S trap, front or back inlet and foot rest any pattern,embedded in cement concrete 1:2:4 type B-0 in sunken floors making connection with flush pipe using new GI flush bend (Floor portion) and making good to floors to match the existing surfaces to the entire satisfaction of Engineer-in-Charge. |
| 41 | Supply and fixing PVC valveless syphonic action type flushing cistern,low level, white 10 ltr capacity,with inlet, ball valve, float and handle including bracketsincluding all connections & flush pipes making connection to WC complete all as specified and as directed. |
| 42 | Supply and fixing in repair vitreous China wash down water closet Pan (pedastal pattern) white including all connections and making good to floor to match the existing surfaces to the entire satisfaction of Engineer-in-Charge. |
| 43 | Supply and fixing plastic water closet seat cover, white, closed pattern with flat bottomand mild steel chromium plated or aluminised hinges complete all as specified and asdirected |
| 44 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specifiedand directed |
| 45 | Material and labour for non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed |
| 46 | Material and labour glazed ceramic tiles in vertial surface 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles laid / fixed over and including 15 mm thick rendering in cement mortar (1:4)complete all as specified and as directed. |