| 1 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth and getting out for laying of pipe lines in any type of soil. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm each in soil. |
| 3 | Removal of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point. |
| 4 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge. |
| 5 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above gound level including removal of debris complete all as specified and directed. |
| 6 | M&L for taking up or down steel water tubing and connections of 15 mm dia including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 7 | M&L for taking up or down steel water tubing and connections of 20 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 8 | M&L for taking up or down steel water tubing and connections of 25 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 9 | M&L for taking up or down steel water tubing and connections of 40 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 10 | M&L for taking up or down steel water tubing and connections of 50 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 11 | M&L for taking up or down steel water tubing and connections of 80 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 12 | M&L for taking up or down steel water tubing and connections of 100 mm bore including cleaning for refixing or remove unserviceable pipe from site complete all as specified and directed |
| 13 | Re-laying / re-fixing galvanised mild steel water tubing of 15 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 14 | Re-laying / re-fixing galvanised mild steel water tubing of 20 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 15 | Re-laying / re-fixing galvanised mild steel water tubing of 25 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 16 | Re-laying / re-fixing galvanised mild steel water tubing of 40 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 17 | Re-laying / re-fixing galvanised mild steel water tubing of 50 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 18 | Re-laying / re-fixing galvanised mild steel water tubing of 80 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 19 | Re-laying / re-fixing galvanised mild steel water tubing of 100 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 20 | S & F galvanised steel water tubing medium grade 15 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 21 | S & F galvanised steel water tubing medium grade 20 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 22 | S & F galvanised steel water tubing medium grade 25 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 23 | S & F galvanised steel water tubing medium grade 40 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 24 | S & F galvanised steel water tubing medium grade 50 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 25 | S & F galvanised steel water tubing medium grade 80 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 26 | S & F galvanised steel water tubing medium grade 100 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 27 | S & F in replacement of gun metal gate valve or glob valves of size 15 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 28 | S & F in replacement of gun metal gate valve or glob valves of size 20 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 29 | S & F in replacement of gun metal gate valve or glob valves of size 25 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 30 | S & F in replacement of gun metal gate valve or glob valves of size 40 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 31 | S & F in replacement of gun metal gate valve or glob valves of size 50 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 32 | S & F in replacement of ductile iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make:-Kirloskar/leader/upadhayay/sant |
| 33 | S & F in replacement of ductile iron sluice valve of 100 mm dia bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make:-Kirloskar/leader/upadhayay/sant |
| 34 | S & F in replacement of ductile iron sluice valve of 150 mm bore sluice valve class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make:-Kirloskar/leader/upadhayay/sant |
| 35 | Supply, laying & testing in repair ductile iron pipe with socket and spigot ends of 100 mm bore class - K-9 ,with ceramic epoxy lining /coating inside and external zinc coating with a bitumen finishing layerconforming toIS - 8329-2000 (Reaffiremed - 2005 Edition 4.1) suitable for \"push on joints\" in any lengths and including providing jointsetc and including taking out old/ unserviceable CI / DI pipes from vertical position orfrom trenches etc complete all as specified and as directed. |
| 36 | Supply, laying & testing in repair ductile iron pipe with socket and spigot ends of 150 mm bore class - K-9 ,with ceramic epoxy lining /coating inside and external zinc coating with a bitumen finishing layerconforming toIS - 8329-2000 (Reaffiremed - 2005 Edition 4.1) suitable for \"push on joints\" in any lengths and including providing joints (Tyton joints)etc and including taking out old/ unserviceable CI / DI pipes from vertical position orfrom trenches etc complete all as specified and as directed. |
| 37 | Supply, laying & testing in repair ductile iron pipe with socket and spigot ends of 200 mm bore class - K-9 ,with ceramic epoxy lining /coating inside and external zinc coating with a bitumen finishing layerconforming toIS - 8329-2000 (Reaffiremed - 2005 Edition 4.1) suitable for \"push on joints\" in any lengths and including providing joints (Tyton joints)etc and including taking out old/ unserviceable CI / DI pipes from vertical position orfrom trenches etc complete all as specified and as directed. Note for item No 35 to 37 : (i) The cost of joints shall deemed to be included in unit rate quoted by the tenderer.(ii) Excavation and earth work shall be measured and paid seperately . |
| 38 | Construction of Valve pit after dismantling of old u/s valve pitofSize 900mm x900mmx900mm (internaldimensions), Stone masonry constructton,tncludlng all necessary excavation and earth work in hard/ dense soil,returning,filling,in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed , PCC in foundation of the mix (1:4..8) Type DQ (using 40 mm graded crushed stone aggregate), PCC Pocing in PCC(1:2:4), type BO using 12.5m crushed graded aggregate, brick masonry in cement mortar (1:4) rendering, 12 mm thick in cement mortar (1.4) Internalty,ftntshed even and fair and pointing flush externally as the work proceeds in the same mortar, Mild steel angle Iron 50x50x6mm frame,MS sheet cover 3.15mm thick with handle and locking arrangment ,painting ,all the exposed MS work with two coats of synthetic enamel paint of tint as approved by the GE/AGE over a coats of red oxide pnmer and painting all the MS embedded in PCC with two coats of black bituminous paint etc, Complete all as specified and shown on drawing. |
| 39 | M & L for cutting of GI/DI/CI pipe 80 to 150 mm bore carefully for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed. |
| 40 | Supply and fix water pipe line route indicator made of size 400 x 300 x 25mm of precast RCC (1:2:4) type B-O using 12.5 mm graded stone aggregate complete all as specified and directed. Note :- Route indicator should be writen as main water supply line complete as directed by Engr-in-Charge. |
| 41 | S & F 50 mm bore air release valve double chamber as per IS 14845 including mounting GI pipe and clamps as per requirement at site suitable for cast iron pipe/ ductile iron pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 42 | S& F in repair ductile iron Pipe fittings for spigot and socketed or flanged pipes i.e, bends, reducer, tail pieces, tapers, tees, caps etc of 80 mm to 300 mm bore pipe complete all as specified and as directed. |
| 43 | M & L for cutting of stone block pavement/road a depth up to 1.5 mtr below the normal ground level and in width equal to external dia plus 300 mm for lay pipe line upto 300 mm dia across the road in horizontal position and making good the cut portion filled with PCC 1:3:6 type C-2 using 40 mm graded stone aggregates 450 mm thick from TOP over 300 mm thick hard core over filled earth to levelled with existing surfaces for smooth plying of vehicles etc complete all as specified and directed. The repaired portion will be match to the existing surface. Note• Cost of PCC ,hard core,stones and Earth shall deemed to be included in unit rate quoted by the tendered. |
| 44 | Supply, installation, testing and commissioning in replacement of indoor Voltage stabilizer 350 KVA with control panel (automatic/servo voltage controller) three phase 50 Hz for \"Automatic controlling/Regulating of voltage comprising auto transformer, buck & boost transformer, wiring and terminations all in Copper (with new filtered and dehydrated transformer oil), servo motor, auto controlled microprocessor based control circuit (Suitable for supply from DG Set also) , auto and bypass arrangement and other fittings & accessories as under:-(i) S&F digital type volt meter to read input/output voltage (0-415)V,Ammeter suitable CT\"s andFrequency meter, Mains/Low/High limit indicators, Manual increase/decrease push button, Auto/Manual mode control switch and output adjustment with the following specifications:-(a) Rated Capacity 350 KVA Copper wound Oil cooled as Per IS 9815, IS : 335(b) System 03 Phase , 50Hz, AC Supply(c) Input Voltage 340V to 480 V(d) Output voltage Set 415V+1% speed of correction 8V/Sec(e) Type of Cooling Naturally Oil Cooled(f) Type of System Unbalanced(g) Operating Temp 15 to 60° C(h)High/Low Voltage cut off feature(j)Protection Under Voltage, Over Voltage, Phase Failure, Reverse phase protection, Over Load protections.(k) Over Voltage cut off(l) Two digital Volt meters (For Incoming and outgoing)with inbuilt selector switch(r)One digital Ammeter(inbuilt selector switch) with suitable CTs of Class 1.0(s) end Terminations with suitable bus bar for terminating 3.5 Core x 400 Sqmm with the end terminationbox along with suitable glands for cables complete.(t) Wheels for uni directional movement Note : Old U/s voltage stablizer will be deposited to AGE E/M store yard by the contractor. |
| 45 | Supply, installation, testing and commissioninng of split casing centrifugal pump sets, suitable for pumping water 3750 LPM discharge at 60 m head (Not less than 100 HP) IP 55, cast iron body with gun metal impellers including fixing of safety valve, pressure guage and priming valve etc direct coupled suitable for operation on 3 phase, 415 V, AC, 50 Hz and mounted on channeliron base frame including nut, bolts & washers etc. PCC foundation, foundation nuts, bolts & washer as per manufacturer\"s instructions including proper size cupper cable from starter to motor of suitable size all as specified & directed. Note : Old pump will be deposited to AGE E/M store yard by the contractor.Asper IS 15301, IS : 6595 (Part-I) HSN Code 8413-70 |
| 46 | Supply, installation, testing and commissioninng of split casing centrifugal pump sets, suitable for pumping water 2208 LPM discharge at 70 m head, (Not less than 60 HP) IP 55, cast iron body with gun metal impellers including fixing of safety valve, pressure guage and priming valve etc direct coupled suitable for operation on 3 phase, 415 V, AC, 50 Hz and mounted on channeliron base frame including nut, bolts & washers etc. PCC foundation, foundation nuts, bolts & washer as per manufacturer\"s instructions including proper size cupper cable from starter to motor of suitable size all as specified & directed. Note : Old pump will be deposited to AGE E/M store yard by the contractor. Asper IS 15301, IS : 6595 (Part-I) HSN Code 8413-70 |
| 47 | S&Finreplacement ofFASDstarterinsheetmetalenclosure suitablefor100HPinductionmotor,3phase440volt complete with over load protection& adjustable relay range 45-75A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. Make :L&T or equivalent approved make. |
| 48 | S&Finreplacement ofFASDstarterinsheetmetalenclosure suitablefor60HPinductionmotor,3phase440volt complete with over load protection& adjustable relay range 45-75A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. Make :L&T or equivalent approved make. |
| 49 | M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buned directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to gatvanised iron strip of 32 x 6 mm as earth lead by means of bolts nuts check nuts & washers of gatvanised iron or steel ,surrounded by charcoal of coke and salt, protected by Gl pipe 40 mm bore (light grade), water pipe 20mm bore Gl medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stone aggregate, 50 mm thick cover of RCC (1:2:4) type B-l using 20 mm graded stone aggregate, reinforced with 8 mm dia TMT bars @ 80 mm clc boath ways including excavation and earth work and removal of surplus soil to distance n exc 50 m complete all shown in electrical plate No 3 of SSR part- 2010 complete all as specified and directed. Note :-(l) The cost of Gl earth lead & G 1 pipe of 7.50 mtr length for protection of Gl wire and excavation work for pit shall deemed to be included in this item. (ii) Earthing test will be carned out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment.(iii) Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. |
| 50 | S& F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm GI strip. |