| 1 | A. PROCUREMENT OF NEW TRANSFORMER |
| 2 | 3.15MVA,33/11KV, Power Transformer |
| 3 | 5MVA,33/11KV, Power Transformer |
| 4 | 10MVA , 33/11KV Power Transfomer |
| 5 | 25KVA, 11/0.433KV,Distribution Transfomer (Al wound) |
| 6 | 63KVA, 11/0.433KV,Distribution Transfomer (Al wound) |
| 7 | 100KVA, 11/0.433 KV, Distribution Transformer (Al wound) |
| 8 | 250KVA, 11/0.433 KV, Distribution Transformer (Cu wound) |
| 9 | B. RENOVATION & UPGRADATION OF EXISTING TRANSFORMER CAPACITY ALONG WITH ASSOCIATED EQUIPMENT |
| 10 | I) BY INSTALLING 2X10 MVA AT 33/11KV IMPHAL POWER HOUSE SUBSTATION |
| 11 | 10 MVA, 33/11 KV Power Transfomer |
| 12 | 33 KV VCB |
| 13 | 33 KV, outdoor type, single phase P. T. |
| 14 | 33 KV, outdoor type, single phase C. T. |
| 15 | 33 KV Isolator |
| 16 | i) 33KV Isolator without Earthing Blade(Motor Operated) |
| 17 | 33 KV Control & Relay Panel |
| 18 | i) For Transformer |
| 19 | 11 KV VCB Panel (800 A) |
| 20 | i) Incommer |
| 21 | ii) Outgoing |
| 22 | iii) Bus Coupler |
| 23 | DC Equipment |
| 24 | i) 110V, 250AH Battery Charger Float Cum Boost. |
| 25 | DC and AC Board |
| 26 | i) 110 V DC DB Panel |
| 27 | ii) LT AC Board/Panel(6-feeder) |
| 28 | Switchyard Lighting |
| 29 | i) 100 Watt LED Flood Light for Switchyard |
| 30 | ii) 40mm dia 3 m long pipe electrode |
| 31 | iii) 50x6 mm GI Flat for Earthing. |
| 32 | 11kV grade PVC insulated steel armoured Al. conductor XLPE power cable |
| 33 | i) 3C, 300 sq.mm |
| 34 | HT XLPE Cable jointing kit complete for |
| 35 | i) 3C, 240mm outdoor |
| 36 | Steel armoured, PVC armoured Copper Control Cable |
| 37 | i) 2C,2.5 Sq. mm |
| 38 | ii) 4C, 2.5 Sq. mm |
| 39 | iii) 5C, 2.5 Sq. mm |
| 40 | iv) 10C, 2.5 Sq. mm |
| 41 | v) 12C, 2.5 Sq. mm |
| 42 | vi) 19C, 2.5 Sq. mm |
| 43 | vii) 4C, 6sq mm (Aluminium)for switchyard lighting |
| 44 | Fire fighting equipment |
| 45 | i) CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 46 | ii) CO2, 50Lb Capacity Extinguisher trolley mountedfor transformers. |
| 47 | Connector (33kV) ( panther to CT,PT) |
| 48 | II) BY INSTALLING 5MVA TRANSFORMER, 33KV C&R PANEL, 33KV CB AND 11KV VCB PANEL AT 33/11KV USOIPOKPI SUBSTATION, MSPCL |
| 49 | 5MVA, 33/11kV Power Transformer |
| 50 | 33kV C&R Panel |
| 51 | 33kV SF6 Circuit Breaker |
| 52 | 11kV VCB panel, 400A (Incomer) |
| 53 | III) BY INSTALLING 2X5 MVA AT 33/11KV MAYANG LANGJING SUBSTATION |
| 54 | Galvanized steel structures@ 4.2 MT per bay |
| 55 | 5 MVA 33/11 KV Power transformer |
| 56 | 33 KV VCB |
| 57 | 33KV Station Class Lightning Arrestor |
| 58 | 33 KV, outdoor type, single phase P. T. |
| 59 | 33 KV, outdoor type, single phase C. T. |
| 60 | 33 KV Isolator |
| 61 | i) 33KV Isolator with Earthing Blade(Motor Operated) |
| 62 | ii) 33KV Isolator without Earthing Blade(Motor Operated) |
| 63 | 33 KV Control & Relay Panel |
| 64 | i) For Transformer |
| 65 | ii) Feeder |
| 66 | 11 KV VCB Panel (800 A) |
| 67 | i) Incommer |
| 68 | ii) Outgoing |
| 69 | iii) Bus Coupler |
| 70 | DC Equipment |
| 71 | 110V, 250AH Battery Charger Float Cum Boost. |
| 72 | DC and AC Board |
| 73 | i) 110 V DC DB Panel |
| 74 | ii) LT AC Board/Panel(6-feeder) |
| 75 | Switchyard Lighting |
| 76 | i) 100 Watt LED Flood Light for Switchyard |
| 77 | ii) Bus bar i/c insulator strings & hardware fittings |
| 78 | iii) 40mm dia 3 m long pipe electrode |
| 79 | iv) 50x6 mm GI Flat for Earthing. |
| 80 | 11kV grade PVC insulated steel armoured Al. conductor XLPE power cable |
| 81 | i) 3C, 300 sq.mm |
| 82 | ii) 3C, 185 sq.mm |
| 83 | iii) Armoured Power Cable 1.1kV XLPE, 3.5C, 35 sqmm |
| 84 | HT XLPE Cable jointing kit complete for |
| 85 | i) 3C, 240mm outdoor |
| 86 | ii) 3C, 185mm outdoor |
| 87 | Steel armoured, PVC armoured Copper Control Cable |
| 88 | i) 2 Core 2.5 Sq. mm |
| 89 | ii) 5 Core 2.5 Sq. mm |
| 90 | iii) 10 Core 2.5 Sq. mm |
| 91 | iv) 12 Core 2.5 Sq. mm |
| 92 | v) 19 Core 2.5 Sq. mm |
| 93 | vi) 4C,6sq mm (Aluminium) for switchyard lighting |
| 94 | Fire fighting equipment |
| 95 | CO2, 50Lb Capacity Extinguisher trolley mountedfor transformers. |
| 96 | Sand Bucket (4Ltr) Stand with 6 Buckets per Stands for switchyard and Control Room. |
| 97 | 100 KVA, 11/0.433KV Distribution Transformer |
| 98 | ACSR Panther Conductor |
| 99 | IV) FROM 2X5 MVA TFR TO 2X10MVA TFR ALONG WITH ASSOCIATED ELEMENTS AND REPLACEMENT OF 24 DC SYSTEM WITH 110V DC SYSTEM 33/11KV MANTRIPUKHRI |
| 100 | 10 MVA, 33/11 KV Power transformer |
| 101 | 33 KV, outdoor type, single phase C. T. |
| 102 | 33kV SF6 Circuit Breaker |
| 103 | 33KV Station Class Lightning Arrestor |
| 104 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 105 | 33kV C&R panel for transformer with differential relay |
| 106 | 33kV C&R panel for feeder 110V DC |
| 107 | 11 KV VCB Panel (800 A) |
| 108 | i) Incommer |
| 109 | ii) Outgoing |
| 110 | 110V, 250AH Battery with Accessories (Maint. free) |
| 111 | 110V, 250AH Battery Charger Float Cum Boost. |
| 112 | Steel armoured, PVC armoured Copper Control Cable |
| 113 | i) 2C, 2.5 Sq. mm |
| 114 | ii) 10C, 2.5 Sq. mm |
| 115 | iii) 19C, 2.5 Sq. mm |
| 116 | ACSR Panther Conductor |
| 117 | Terminal Pads and Connectors for Panther |
| 118 | Galvanised Bolt & Nuts (with spring) |
| 119 | 3C,185 sq.mm XLPE Cable |
| 120 | 100 Watt LED Flood Light for Switchyard |
| 121 | CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 122 | 110 V DC DB Panel |
| 123 | Trip Coil/Closing (33kV), 110V (CGL make) |
| 124 | Contactor 110V DC (Schneider make), 5NO |
| 125 | V) REPLACEMENT OF OLD TRANSFORMER (2x10MVA) AT 132/33KV CHURACHANDPUR SUBSTATION |
| 126 | 10MVA 33/11kV Power Transformer |
| 127 | 33kV outdoor type single phase CT |
| 128 | 33kV VCB |
| 129 | 36kV Station Class Lightning Arrestor |
| 130 | 33kV Control & RelayPanel for Transformer with differential Relay |
| 131 | 11kV VCB Panel (1250A)-Incomer |
| 132 | 11kV VCB Panel (1250A)-Outgoing |
| 133 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 134 | i)3C, 300 sq mm |
| 135 | Steel armoured, PVC armoured Copper Control Cable |
| 136 | i) 5C, 2.5 sq mm |
| 137 | ii) 10C, 2.5 sq mm |
| 138 | iii) 19C, 2.5 sqmm |
| 139 | VI) FROM 2X2.5 MVA TFR TO 2X5 MVA TFR ALONG WITH ASSOCIATED ELEMENTS AT 33/11KV GAMPHAZOL SUBSTATION |
| 140 | 5 MVA, 33/11 KV Power transformer |
| 141 | 33 KV, outdoor type, single phase C. T. |
| 142 | 33kV SF6 Circuit Breaker |
| 143 | 33KV Station Class Lightning Arrestor |
| 144 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 145 | 11 KV VCB Panel (800 A) |
| 146 | i) Incommer |
| 147 | ii) Outgoing |
| 148 | 110V, 250AH Battery with Accessories (Maint. free) |
| 149 | 110V, 250AH Battery Charger Float Cum Boost. |
| 150 | 110 V DC DB Panel |
| 151 | Steel armoured, PVC armoured Copper Control Cable |
| 152 | 2 Core 2.5 Sq. mm |
| 153 | 10 Core 2.5 Sq. mm |
| 154 | 19 Core 2.5 Sq. mm |
| 155 | ACSR Panther Conductor |
| 156 | Terminal Pads and Connectors for Panther |
| 157 | Galvanised Bolt & Nuts (with spring) |
| 158 | 185 sq.mm (3 core) - XLPE Power Cable |
| 159 | 100 Watt LED Flood Light for Switchyard |
| 160 | CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 161 | C. REPLACEMENT OF OLD & OBSOLETE ELECTRICAL EQUIPMENT AT |
| 162 | I) 33/11KV KHWAIRAKPAM SUBSTATION |
| 163 | 33kV outdoor type single phase PT |
| 164 | 36kV Station Class Lightning Arrestor |
| 165 | 11kV VCB Panel (1250A)-Incomer |
| 166 | 11kV VCB Panel (1250A)-Outgoing |
| 167 | 33kV Isolator with E/S (motor operated) |
| 168 | 33kV Isolator without E/S (motor operated) |
| 169 | 33 KV VCB breaker |
| 170 | 33kV C&R Panel for transformer with differential relay |
| 171 | II) 33/11KV NEW LAMKA SUBSTATION |
| 172 | 33kV outdoor type single phase CT |
| 173 | 33kV outdoor type single phase PT |
| 174 | 11kV VCB Panel (1250A)-Incomer |
| 175 | 11kV VCB Panel (1250A)-Outgoing |
| 176 | 33kV Isolator with E/S (motor operated) |
| 177 | 33kV Isolator without E/S (motor operated) |
| 178 | 33kV SF6 Circuit Breaker |
| 179 | 24 V battery with accessories (set of 12 cells) |
| 180 | 24 V battery charger |
| 181 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 182 | i) 3C, 185 sq mm |
| 183 | 5 MVA, 33/11kV Power Transformer |
| 184 | III) 33/11KV KAKCHING SUBSTATION |
| 185 | 110V, 250AH Battery Charger Float Cum Boost. |
| 186 | 24 V battery with accessories (set of 12 cells) |
| 187 | 24 V battery charger |
| 188 | 11kV VCB Panel (1250A)-Incomer |
| 189 | 11kV VCB Panel (1250A)-Outgoing |
| 190 | IV) 33/11KV THINKEW SUBSTATION |
| 191 | 11kV VCB Panel (1250A)-Incomer |
| 192 | 11kV VCB Panel (1250A)-Outgoing |
| 193 | 33kV VCB |
| 194 | 33kV outdoor type single phase CT |
| 195 | 33kV outdoor type single phase PT |
| 196 | 11/0.4 kV,63KVA Station transformer |
| 197 | Directional OC/EF relay (110V DC) with RS485 Modbus |
| 198 | 36kV Station Class Lightning Arrestor |
| 199 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 200 | 3C, 120 sq mm |
| 201 | 3C, 185 sq mm |
| 202 | Control Cables |
| 203 | 5C, 2.5 sq mm |
| 204 | 10C, 2.5 sq mm |
| 205 | 19C, 2.5 sqmm |
| 206 | V) 33/11KV SINGHAT SUBSTATION |
| 207 | 24 V battery with accessories (set of 12 cells) |
| 208 | 11kV VCB Panel (1250A)-Incomer |
| 209 | 11kV VCB Panel (1250A)-Outgoing |
| 210 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 211 | 3C,120 sq mm |
| 212 | VI) 33/11KV MOIRANG LAMKHAI SUBSTATION |
| 213 | 33kV outdoor type single phase CT |
| 214 | 33kV outdoor type single phase PT |
| 215 | 36kV Station Class Lightning Arrestor |
| 216 | 11kV VCB Panel (1250A)-Incomer |
| 217 | 11kV VCB Panel (1250A)-Outgoing |
| 218 | 33kV Isolator with E/S (motor operated) |
| 219 | 33kV Isolator without E/S (motor operated) |
| 220 | 33 KV VCB breaker |
| 221 | Steel armoured, PVC armoured Copper Control Cable |
| 222 | 19C, 2.5 sqmm |
| 223 | 33kV C&R Panel for transformer with differential relay |
| 224 | VII) 132/33/11KV NINGTHOUKHONG SUBSTATION |
| 225 | 33kV outdoor type single phase CT |
| 226 | 33kV outdoor type single phase PT |
| 227 | 11kV VCB Panel (1250A)-Incomer |
| 228 | 11kV VCB Panel (1250A)-Outgoing |
| 229 | Steel armoured, PVC armoured Copper Control Cable |
| 230 | i) 10C x 2.5 sqmm |
| 231 | ii) 19C x 2.5 sqmm |
| 232 | 110V Battery charger |
| 233 | VIII) 33/11KV CHANDEL SUBSTATION |
| 234 | 33kV outdoor type single phase CT |
| 235 | 33kV outdoor type single phase PT |
| 236 | 36kV Station Class Lightning Arrestor |
| 237 | 11kV VCB Panel (1250A)-Incomer |
| 238 | 11kV VCB Panel (1250A)-Outgoing |
| 239 | 33 KV SF6 breaker |
| 240 | 110V, 250AH Battery with Accessories (Maint. free) |
| 241 | 110V, 250AH Battery Charger Float Cum Boost. |
| 242 | 11kV OC/EF relay (110V DC) |
| 243 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 244 | i) 3C, 185 sq mm |
| 245 | ii) 3C, 300 sq mm |
| 246 | IX) 33/11KV NEW CHAYANG SUBSTATION |
| 247 | 33kV outdoor type single phase CT |
| 248 | 33kV outdoor type single phase PT |
| 249 | 36kV Station Class Lightning Arrestor |
| 250 | 11kV VCB Panel (1250A)-Incomer |
| 251 | 11kV VCB Panel (1250A)-Outgoing |
| 252 | 33kV Feeder Panel |
| 253 | 33kV Isolator with E/S (motor operated) |
| 254 | 33kV Isolator without E/S (motor operated) |
| 255 | 33 KV SF6 breaker |
| 256 | 110V, 250AH Battery with Accessories (Maint. free) |
| 257 | 110V, 250AH Battery Charger Float Cum Boost. |
| 258 | 11kV OC/EF relay (110V DC) |
| 259 | Steel armoured, PVC armoured Copper Control Cable |
| 260 | i) 5C, 2.5 sq mm |
| 261 | ii) 10C, 2.5 sq mm |
| 262 | iii) 19C, 2.5 sqmm |
| 263 | 3C, 180 sqmm XLPE Power Cable |
| 264 | X) 33/11KV KHOUPUM SUBSTATION |
| 265 | 33kV outdoor type single phase CT |
| 266 | 36kV Station Class Lightning Arrestor |
| 267 | 11kV VCB Panel (1250A)-Incomer |
| 268 | 11kV VCB Panel (1250A)-Outgoing |
| 269 | 33kV Isolator with E/S (motor operated) |
| 270 | 33kV Isolator without E/S (motor operated) |
| 271 | 110V, 250AH Battery with Accessories (Maint. free) |
| 272 | 110V, 250AH Battery Charger Float Cum Boost. |
| 273 | Steel armoured, PVC armoured Copper Control Cable |
| 274 | i) 10C, 2.5 sq mm |
| 275 | ii) 12C, 2.5 sqmm |
| 276 | 33kV VCB Circuit Breaker |
| 277 | XI) 33/11KV MACHI SUBSTATION |
| 278 | 36kV Station Class Lightning Arrestor |
| 279 | 11kV VCB Panel (1250A)-Incomer |
| 280 | 11kV VCB Panel (1250A)-Outgoing |
| 281 | 33kV Isolator with E/S (motor operated) |
| 282 | 33kV Isolator without E/S (motor operated) |
| 283 | 110V, 250AH Battery with Accessories (Maint. free) |
| 284 | 110V, 250AH Battery Charger Float Cum Boost. |
| 285 | Supply of 11kV grade PVC insulated steel armoured Al conductor XLPE power cables along with necessary termination and jointing kit accessories as per requirement |
| 286 | i) 120 sq mm (3 core) |
| 287 | D. SUPPLY AND INSTALLATION OF 33KV CTs, 33KV PTs, 33KV LAs, 33KV C&R PANEL, 33KV ISOLATORS, 11KV CURRENT TRANSFORMER, 11KV POTENTIAL TRANSFORMER, 11KV VCB PANEL ETC. |
| 288 | I) INSTALLATION OF BAY EQUIPMENT FOR 33KV IROISEMBA (DC), 33KV SEKMAI AND 33KV NILAKUTHI LINE BAYS (4BAYS) AT 33/11KV LEIMAKHONG SUBSTATION |
| 289 | 33 KV, outdoor type, single phase C. T. |
| 290 | 33kV outdoor type single phase PT |
| 291 | 33kV SF6 Circuit Breaker |
| 292 | 33KV Station Class Lightning Arrestor |
| 293 | 33kV Isolator with E/S (motor operated) |
| 294 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 295 | 250KVA, 11/0.433KV, Distribution tranformer |
| 296 | 33kV C&R panel for transformer with differential relay |
| 297 | 33kV C&R panel for feeder 110V DC |
| 298 | 11 KV VCB Panel (800 A) |
| 299 | i) Incommer |
| 300 | ii) Outgoing |
| 301 | Steel armoured, PVC armoured Copper Control Cable |
| 302 | i) 2C, 2.5 Sq. mm |
| 303 | ii) 10C, 2.5 Sq. mm |
| 304 | iii) 19C, 2.5 Sq. mm |
| 305 | ACSR Panther Conductor |
| 306 | Terminal Pads and Connectors for Panther |
| 307 | Galvanized steel structures@ 4.2 MT per bay |
| 308 | Galvanised Bolt & Nuts (with spring) |
| 309 | 100 Watt LED Flood Light for Switchyard |
| 310 | CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 311 | Cable Termination Kit |
| 312 | Bus bar i/c insulators strings, connectors, shielding materials |
| 313 | II) SUPPLY AND INSTALLATION OF 33KV CTs, 33KV PTs, 33KV LAs, 33KV C&R PANEL, 33KV ISOLATORS, 11KV CURRENT TRANSFORMER, 11KV POTENTIAL TRANSFORMER, 11KV VCB PANEL AT 33/11KV WANGJING SUBSTATION |
| 314 | 33KV |
| 315 | i) 33kV Current transformer |
| 316 | ii) 33kV Potential transformer |
| 317 | iii) 33kV, 10KA Lightning Arrestor |
| 318 | iv) 33kV C&R Panel |
| 319 | v) 33kV SF6 Circuit Breaker |
| 320 | vi) 33kV Isolator with earth blade |
| 321 | 11KV |
| 322 | i) 11kV Current transformer |
| 323 | ii) 11kV Potential transformer |
| 324 | iii) 11kV VCB panel, 400A (Incomer) |
| 325 | iv) 11kV VCB panel, 400A (Outgoing) |
| 326 | III) RENOVATION AND MODERNIZATION OF 33/11KV IROISEMBA SUBSTATION |
| 327 | 33 KV VCB |
| 328 | 33KV Station Class Lightning Arrestor |
| 329 | 33 KV, outdoor type, single phase P. T. |
| 330 | 33 KV, outdoor type, single phase C. T. |
| 331 | 33 KV Isolator |
| 332 | 33KV Isolator with Earthing Blade(Motor Operated) |
| 333 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 334 | 33 KV Control & Relay Panel |
| 335 | i) Feeder |
| 336 | 11 KV VCB Panel (800 A) |
| 337 | i) Incommer |
| 338 | ii) Outgoing |
| 339 | iii) Bus Coupler |
| 340 | HT XLPE Cable jointing kit complete for |
| 341 | i) 240mm 3 core outdoor |
| 342 | DC and AC Board |
| 343 | i) 110 V DC DB Panel |
| 344 | ii) LT AC Board/Panel(6-feeder) |
| 345 | Switchyard Lighting |
| 346 | 100 Watt LED Flood Light for Switchyard |
| 347 | Lighting DB |
| 348 | 40mm dia 3 m long pipe electrode |
| 349 | 50x6 mm GI Flat for Earthing. |
| 350 | 11kV grade PVC insulated steel armoured Al. conductor XLPE power cable |
| 351 | 3C, 300 sq.mm |
| 352 | Armoured Power Cable 1.1kV XLPE, 3.5C, 35 sqmm |
| 353 | HT XLPE Cable jointing kit complete for |
| 354 | i) 3C, 240mmoutdoor |
| 355 | Steel armoured, PVC armoured Copper Control Cable |
| 356 | i) 2C, 2.5 Sq. mm |
| 357 | ii) 4C, 2.5 Sq. mm |
| 358 | iii) 5C, 2.5 Sq. mm |
| 359 | iv) 10C, 2.5 Sq. mm |
| 360 | v) 12C, 2.5 Sq. mm |
| 361 | vi) 4 core aluminium 6sq mm for switchyard lighting |
| 362 | Fire fighting equipment |
| 363 | i) Foam Type, 1 gallonwall mounted for battery room |
| 364 | ii) CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 365 | iii) CO2, 50Lb Capacity Extinguisher trolley mountedfor transformers. |
| 366 | ACSR Panther Conductor |
| 367 | Relay (Over Current Earth Fault) (Model P-141(24-220V DC), MICOM Make |
| 368 | Trip Coil/Closing (33kV) (24V-110V) |
| 369 | Terminal pads and connectors for isolators |
| 370 | Connector (33kV) ( panther to CT,PT) |
| 371 | IV) REPLACEMENT OF 11KV VCB PANEL, 33KV CT AND SWITCHYARD LIGHT AT 132/33KV YUREMBAM SUBSTATION |
| 372 | 33 KV, outdoor type, single phase C. T. |
| 373 | 11 KV VCB Panel (800 A) |
| 374 | Incommer |
| 375 | Outgoing |
| 376 | 100 Watt LED Flood Light for Switchyard |
| 377 | V) REPLACEMENT OF CT, PT AND LA FOR 132KV IMPHAL-III LINE BAY AT POWERGRID |
| 378 | 132 KV Line CT |
| 379 | 132 KV Line PT |
| 380 | 132 KV Line LA |
| 381 | Steel armoured, PVC armoured Copper Control Cable |
| 382 | 5C x 2.5 Sq.mm |
| 383 | 10C x 2.5 Sq.mm |
| 384 | 14C x 2.5 Sq.mm |
| 385 | VI) REPLACEMENT OF EXISTING LINE CT WITH HIGHER CURRENT RATING FOR 132KV IMPHAL-I, IMPHAL-II, IMPHAL-III LINE AT 132/33KV MSPCL YUREMBAM SUBSTATION |
| 386 | 132 KV Line CT |
| 387 | VII) SUPPLY AND INSTALLATION OF 11KV CT, 11KV PT, AND 11KV VCB PANEL AT 33/11KV KASOM KHULLEN SUBSTATION |
| 388 | i) 11kV Current transformer |
| 389 | ii) 11kV Potential transformer |
| 390 | iii) 11kV VCB panel, 400A (Incomer) |
| 391 | iv) 11kV VCB panel, 400A (Outgoing) |
| 392 | VIII) SUPPLY AND INSTALLATION OF 33KV CTs, 33KV PTs, 33KV LAs, 33KV C&R PANEL, 33KV ISOLATORS, 11KV VCB PANEL AT 33/11KV KHONGJOM SUBSTATION |
| 393 | 33kV Current transformer |
| 394 | 33kV, 10KA Lightning Arrestor |
| 395 | GI earth pipe 6sqmm,6.2m |
| 396 | Supply of 11KV grade PVC insulated steel armoured AI conductor XLPEpowr cables (3C,185sq.mm) |
| 397 | Supply of Control Cable 10C, 2.5 Sq. mm |
| 398 | 33kV Potential transformer |
| 399 | 33kV Isolator with earth blade |
| 400 | 33kV C&R Panel |
| 401 | 11kV VCB Panel (800A) Outgoing |
| 402 | 33kV SF6 Circuit Breaker |
| 403 | 50x5 mm MS Flat for Earthing |
| 404 | IX) SUPPLY AND INSTALLATION OF 11KV CT, 11KV PT, AND 11KV VCB PANEL AT 33/11KV THOUBAL(OLD) SUBSTATION |
| 405 | i) 11kV Current transformer |
| 406 | ii) 11kV Potential transformer |
| 407 | iii) 11kV VCB panel, 400A (Incomer) |
| 408 | iv) 11kV VCB panel, 400A (Outgoing) |
| 409 | X) RENOVATION AND MODERNIZATION OF 33/11 KV NONEY SUBSTATION |
| 410 | 33 KV VCB |
| 411 | 33KV Station Class Lightning Arrestor |
| 412 | 33 KV, outdoor type, single phase P. T. |
| 413 | 33 KV, outdoor type, single phase C. T. |
| 414 | 33 KV Isolator |
| 415 | i) 33KV Isolator with Earthing Blade(Motor Operated) |
| 416 | ii) 33KV Isolator without Earthing Blade(Motor Operated) |
| 417 | 33 KV Control & Relay Panel |
| 418 | i) For Transformer |
| 419 | ii) Feeder |
| 420 | 11 KV VCB Panel (800 A) |
| 421 | i) Incommer |
| 422 | ii) Outgoing |
| 423 | iii) Bus Coupler |
| 424 | DC and AC Board |
| 425 | i) 110 V DC DB Panel |
| 426 | ii) LT AC Board/Panel(6-feeder) |
| 427 | Switchyard Lighting |
| 428 | 100 Watt LED Flood Light for Switchyard |
| 429 | 40mm dia 3 m long pipe electrode |
| 430 | 50x6 mm GI Flat for Earthing. |
| 431 | 11kV grade PVC insulated steel armoured Al. conductor XLPE power cable |
| 432 | 3C, 300 sq.mm |
| 433 | Armoured Power Cable 1.1kV XLPE, 3.5C,35 sqmm |
| 434 | HT XLPE Cable jointing kit complete for |
| 435 | i) 185mm 3 core outdoor |
| 436 | Steel armoured, PVC armoured Copper Control Cable |
| 437 | i) 2C, 2.5 Sq. mm |
| 438 | iii) 5C, 2.5 Sq. mm |
| 439 | iv) 10C, 2.5 Sq. mm |
| 440 | v) 12C, 2.5 Sq. mm |
| 441 | vi) 19C, 2.5 Sq. mm |
| 442 | vi) 4 core aluminium 6sq mm for switchyard lighting |
| 443 | Fire fighting equipment |
| 444 | i) Foam Type, 1 gallonwall mounted for battery room |
| 445 | ii) CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 446 | iii) CO2, 50Lb Capacity Extinguisher trolley mountedfor transformers. |
| 447 | Sand Bucket (4Ltr) Stand with 6 Buckets per Stands for switchyard and Control Room. |
| 448 | ACSR Panther Conductor |
| 449 | Connector (33kV) ( panther to CT,PT) |
| 450 | XI) RENOVATION AND MODERNIZATION OF 33/11 KV TOUSEM SUBSTATION IN TAMENGLONG DISTRICT |
| 451 | Galvanized steel structures@ 4.2 MT per bay |
| 452 | 33 KV VCB |
| 453 | 33KV Station Class Lightning Arrestor |
| 454 | 33 KV, outdoor type, single phase P. T. |
| 455 | 33 KV, outdoor type, single phase C. T. |
| 456 | 33 KV Isolator |
| 457 | i) 33KV Isolator with Earthing Blade(Motor Operated) |
| 458 | ii) 33KV Isolator without Earthing Blade(Motor Operated) |
| 459 | 33 KV Control & Relay Panel |
| 460 | i) For Transformer |
| 461 | ii) Feeder |
| 462 | 11 KV VCB Panel (800 A) |
| 463 | i) Incommer |
| 464 | ii) Outgoing |
| 465 | Battery & Charger |
| 466 | i) 24 V battery with accessories (set of 12 cells) |
| 467 | 24 V battery charger |
| 468 | DC and AC Board |
| 469 | 24 Volts D.C Distributing Board |
| 470 | LT AC Board/Panel(6-feeder) |
| 471 | Switchyard Lighting |
| 472 | 100 Watt LED Flood Light for Switchyard |
| 473 | 40mm dia 3 m long pipe electrode |
| 474 | 50x6 mm GI Flat for Earthing. |
| 475 | 11kV grade PVC insulated steel armoured Al. conductor XLPE power cable |
| 476 | 185mm 3 core outdoor |
| 477 | Armoured Power Cable 1.1kV XLPE,3.5C,35 sqmm |
| 478 | HT XLPE Cable jointing kit complete for |
| 479 | i) 185mm 3 core outdoor |
| 480 | Steel armoured, PVC armoured Copper Control Cable |
| 481 | i) 2 Core 2.5 Sq. mm |
| 482 | iii) 5 Core 2.5 Sq. mm |
| 483 | iv) 10 Core 2.5 Sq. mm |
| 484 | v) 12 Core 2.5 Sq. mm |
| 485 | vi) 19 Core 2.5 Sq. mm |
| 486 | vi) 4 core aluminium 6sq mm for switchyard lighting |
| 487 | Fire fighting equipment |
| 488 | i) CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 489 | ii) CO2, 50Lb Capacity Extinguisher trolley mountedfor transformers. |
| 490 | Sand Bucket (4Ltr) Stand with 6 Buckets per Stands for switchyard and Control Room. |
| 491 | Relay (Model P-141(24-220V DC), MICOM Make |
| 492 | Connector (33kV) ( panther to CT,PT) |
| 493 | XII) REPLACEMENT OF EXISTING 11KV PANELS (OLD), BATTERY AND BATTERY CHARGES, CT, 33KV SF6 BREAKERS, 33KV CRP AND ISOLATORS WITH NEW ONES AT 33/11KV NILAKUTHI |
| 494 | 33 KV, outdoor type, single phase C. T. |
| 495 | 33KV Station Class Lightning Arrestor |
| 496 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 497 | 33kV C&R panel for transformer with differential relay |
| 498 | 33kV C&R panel for feeder 110V DC |
| 499 | 11 KV VCB Panel (800 A) |
| 500 | i) Incommer |
| 501 | ii) Outgoing |
| 502 | 110V, 250AH Battery with Accessories (Maint. free) |
| 503 | 110V, 250AH Battery Charger Float Cum Boost. |
| 504 | 110 V DC DB Panel |
| 505 | Steel armoured, PVC armoured Copper Control Cable |
| 506 | i) 2 Core 2.5 Sq. mm |
| 507 | ii) 10 Core 2.5 Sq. mm |
| 508 | iii) 19 Core 2.5 Sq. mm |
| 509 | ACSR Panther Conductor |
| 510 | Terminal Pads and Connectors for Panther |
| 511 | Replacement of old electromechanical Relay with 3OC/EF Numerical Relay 110V DC |
| 512 | Galvanised Bolt & Nuts (with spring) |
| 513 | 3C, 185 sq.mm, XLPE Power Cable |
| 514 | 100 Watt LED Flood Light for Switchyard |
| 515 | CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 516 | Cable Termination Kit |
| 517 | XIII) INSTALLATION OF BAY EQUIPMENT FOR 33KV GELNEL AND 33KV GAMPHAZOL LINE BAYS (2BAYS) AT 33/11KV KANGPOKPI SUBSTATION |
| 518 | 33 KV, outdoor type, single phase C. T. |
| 519 | 33kV outdoor type single phase PT |
| 520 | 33kV SF6 Circuit Breaker |
| 521 | 33KV Station Class Lightning Arrestor |
| 522 | 33kV Isolator with E/S (motor operated) |
| 523 | 33KV Isolator without Earthing Blade(Motor Operated) |
| 524 | 250 KVA, 11/0.433KV Distribution Transformer |
| 525 | 33kV C&R panel for feeder 110V DC |
| 526 | 11 KV VCB Panel (800 A) |
| 527 | i) Incommer |
| 528 | ii) Outgoing |
| 529 | 110V, 250AH Battery with Accessories (Maint. free) |
| 530 | 110V, 250AH Battery Charger Float Cum Boost. |
| 531 | Steel armoured, PVC armoured Copper Control Cable |
| 532 | i) 2C, 2.5 Sq. mm |
| 533 | ii) 10C, 2.5 Sq. mm |
| 534 | iii) 19C, 2.5 Sq. mm |
| 535 | ACSR Panther Conductor |
| 536 | Terminal Pads and Connectors for Panther |
| 537 | Galvanized steel structures@ 4.2 MT per bay |
| 538 | Replacement of old electromechanical Relay with 3OC/EF Numerical Relay 110V DC |
| 539 | Galvanised Bolt & Nuts (with spring) |
| 540 | 100 Watt LED Flood Light for Switchyard |
| 541 | CO2, 10Lb Capacity Extinguisher wall mounted for control room |
| 542 | Bus bar i/c insulators strings, connectors, shielding materials |
| 543 | E. PROCUREMENT OF SUBSTATION MACHINERIES |
| 544 | I) PROCUREMENT OF 20KL TRANSFORMER OIL STORAGE TANK (MOVABLE) |
| 545 | 20kL mobile oil storage tank |
| 546 | II) PROCUREMENT OF HEAT LESS MOBILE DRY AIR GENERATOR PLANT FOR POWER TRANSFORMER |
| 547 | Heat less Mobile Dry Air Generator Plant (inclusive off onsite installation, demonstration and commissioning |
| 548 | Mandatory Spares as per TS (set of Gasket, o rings, fuses, switches etc and consumable like compressor oil, filters etc) |
| 549 | III) PROCUREMENT OF SELF-PROPELLED ARTICULATED BOOM LIFT |
| 550 | Self proppelled Articulated Boom Lift |
| 551 | IV) PROCUREMENT OF MANDATORY SPARE & INVENTORY AS PER CEA GUIDELINES FOR 132/33KV SUBSTATIONS AND 33/11KV SUBSTATIONS |
| 552 | i) Distance Relay(Model:P-442(110-22v dc) MICOM Make) |
| 553 | ii) Transformer {Model P-632(110-220V dc) MICOM Make) |
| 554 | iii) Backup Relay (Over current , Earth Fault){Model P-141(110-220V dc), MICOM Make) |
| 555 | 33/11KV Relay |
| 556 | Relay {Model:P-111(24-220V dc),MICOM Make) |
| 557 | Relay (over Current, Earth Fault ) {Model ADR-141A(110V dc), ASHIDA Make) |
| 558 | Relay (over Current, Earth Fault ) {Model ADR-141C(110V dc), ASHIDA Make} |
| 559 | Transformer ,{Model: NPA-422,Avana Make} |
| 560 | Feeder, ,{Model: NPA-141,Avana Make} |
| 561 | Feeder, ,{Model: NPA-141N,Avana Make} |
| 562 | Relay(Over current, Earth Fault),{Model: MI-103,Easun Reyrolle Make} |
| 563 | Relay(Over current, Earth Fault),{Model: MI-113,Easun Reyrolle Make} |
| 564 | Trip Circuit Supervision Relay, 220V (Alstom Make) |
| 565 | Trip Circuit Supervision Relay, 110V (Alstom Make) |
| 566 | Trip Circuit Supervision Relay, 24V (Alstom Make) |
| 567 | Trip Coil Closing(132KV),110V, {CGL Make} |
| 568 | Trip Coil/ Closing(132KV),220V, {CGL Make} |
| 569 | Trip Coil/ Closing(33KV),24V, {CGL Make} |
| 570 | Trip Coil/ Closing(33KV),110V, {CGL Make} |
| 571 | Trip Coil/ Closing (33KV),220V, {CGL Make} |
| 572 | Trip Coil/ Closing ,220V, {BHEL Make} |
| 573 | Trip Coil/ Closing ,220V, {SEIMEN Make} |
| 574 | Trip Coil/ Closing ,110V, {SEIMEN Make} |
| 575 | Trip Coil/ Closing ,220V, {AREVA Make} |
| 576 | Trip Coil/ Closing ,110V, {AREVA Make} |
| 577 | Trip Coil/ Closing ,110V, {ABB Make} |
| 578 | 132/33KV Isolator |
| 579 | i) Support Isolators |
| 580 | ii) Cu contact fingers for male & female contacts |
| 581 | iii) Terminal pads and connectors |
| 582 | CURRENT TRANSFORMER (CT) |
| 583 | i) Connector (132KV) {Panther to CT} |
| 584 | ii) Connector (33KV) {Panther to CT} |
| 585 | iii) Connector (132KV) {Panther to CVT/PT} |
| 586 | 220 V, Battery Charger |
| 587 | 110 V, Battery Charger |
| 588 | 24 V, Battery Charger |
| 589 | 110 V, Battery Bank |
| 590 | 24 V, Battery Bank |
| 591 | ACSR Bersimis Conductor |
| 592 | ACSR PantherConductor |
| 593 | ACSR MooseConductor |
| 594 | Disc Insulator 70 KN |
| 595 | Single tension Hardware Stringwith hanger |
| 596 | Double tension Hardware String with hanger |
| 597 | 33KV VCB |
| 598 | 33 KV DO Fuse set |
| 599 | 33 KV Isolator with earthing Blade Manual |
| 600 | 33KV Station Class LA |
| 601 | 33KV , outdoor type single phase PT |
| 602 | 33KV , outdoor type single phase CT |
| 603 | Procurement of 145kV, Bushing for 31.5 MVA, 132/33kv Power Transformer at 132/33kV Yurembam Substation |
| 604 | 11kV Potential Transfomer, 3 phase, Dry type, Resin Cast, 2 core (Metering & Protection), Inddor Cubicle Model, Ratio: 11KV√3/ 110V√3(Details as per Annexure IX) |
| 605 | CGL |
| 606 | Biecco Lawrie/ Biectech |
| 607 | Schneider/Areva |
| 608 | ABB |
| 609 | Siemens |
| 610 | F. SUPPLY OF ABT ENERGY METER |
| 611 | 0.2S Class ABT energy meter |