Housing Urban and Rular Development Government Departments Closing in 0 days TDR #51542446

Tender For Upgradation Of 30 Bedded Rural Hospital To 100 Beded Sub District Hospital At Mehkar Dist. Buldana (With Electrification) (2Nd Call)

Issued by Government Departments · mehkar, Maharashtra
Tender Value
36.15 Crore
Estimated cost
Bid Submission
14 Oct 2025
0 days left
EMD
18.23 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mehkar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Upgradation Of 30 Bedded Rural Hospital To 100 Beded Sub District Hospital At Mehkar Dist. Buldana (With Electrification) (2Nd Call)

BOQ

Name of Work: Upgradationof30BededRuralHospitalto100Beded Sub District Hospital at Mehkar Dist.Buldana (With Electrification)
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up toadistanceof50m. beyondthebuildingareaandstacking andspreadingasdirected,dewatering,preparingthebedfor thefoundationandnecessarybackfilling,ramming,watering including shoring and strutting etc. complete.(Lift upto 1.5m.) By Mechanical Means
2Excavationforfoundationinearth,soilsofalltypes,sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift from 1.5m to 3.0m) By Mechanical Means
3ExcavationforfoundationinHardmurumincludingremoving the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling,ramming,wateringincludingshoringandstrutting etc.complete. (Liftfrom1.5to3.0m.)ByMechanicalMeans
4Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres,beyondthebuildingareaandstackingandspreading asdirected,dewatering,preparingthebedforthefoundation and necessary back filling, ramming, watering including shoring and strutting etc.complete.(Lift from 1.5m to 3.0m.) By Mechanical Means
5Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material uptoadistanceof50metresbeyondthebuildingareaand stackingasdirected,includingdewatering,preparingthebed forthefoundationandnecessarybackfillingwithavailable earth/murum, ramming, watering including shoring and strutting etc. complete.(Lift from 1.5m To 3.0m.) By Mechanical Means
6ProvidingpreconstructionalantitermitetreatmentasperI.S. 6313(Part- II)bytreatingthebottomsurfaceandsidesof excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfacearea covering 10 years guarantee on bond paper.
7ProvidingpreconstructionalantitermitetreatmentasperI.S. 6313(Part- II)treatmentbytreatingthebackfillinimmediate contactwithfoundationattherateof5litresofemulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of verticalsurfaceareacovering10yearsguaranteeonbond paper.
8Providingantitermitetreatmentaroundtheperipheryofthe existing building as per I.S. 6313(Part-III) by excavating trenches of 20cm width and exposing the sides of columns and plinth beams upto a depth of 300mm and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per One Running Metre and refilling the trenches etc. complete covering 2 years guarantee on bond paper.
9Providingsolingusing80mmsizetrapmetalin15cm.layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
10Providing and laying Cast in situ/Ready Mix cement concrete in M15oftrap/ granite/ quartzite/ gneissmetalforfoundationand bedding/steps including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is consideredforrenderingunevenandhoneycombedsurface, only.Newlylaidconcreteshallbecoveredbygunnybag, plastic,tarpaulinetc. (Woodencenteringwillnotbeallowed.), withfullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)
11Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm to 20cmincludingwateringandcompactionetc. complete.
12ProvidingpreconstructionalantitermitetreatmentasperI.S. 6313(Part- II)bytreatingthetopsurfaceofplinthfillingatthe rateof5litresofemulsionconcentrateat1.0percentof clorophyrifospersquaremetreofsurfaceareacoveringten years guarantee on bond paper.
13ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-25oftrap/ granite/ quartzite/ gneissmetalforR.C.C. workin foundationslikeraft,stripfoundations,grillageandfootingsofR.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork, cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided(Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC withSCADAenabledreversibleDrumTypemixer/ concrete Batchmixplant(Panmixer)etc.complete.Withfine aggregate(Crushed sand VSI Grade)
14ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionfinishingtheformedsurfaceswithcementmortar 1:3 of sufficient minimum thickness to give a smooth and even surfaceorrougheningifspecialfinishistobeprovidedand curingetc.complete, (Excludingreinforcementandstructural steel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/ concreteBatch mixplant(Panmixer)etc. complete.Withfine aggregate(Crushed sand VSI Grade)
15First Floor
16Second Floor
17Third Floor
18Fourth Floor
19Providing and laying Cast in situ/Ready Mix cement concrete in M-25oftrap/ granite/ quartzite/ gneissmetalforR.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping,compactionandrougheningthesurfaceifspecial finishistobeprovidedandcuringetc.complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processorbasedPLCwithSCADAenabledreversibleDrum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade)
20First Floor
21Second Floor
22Third Floor
23Fourth Floor
24Providing and laying Cast in situ/Ready Mix cement concrete in M-25oftrap/ granite/ quartzite/ gneissmetalforR.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping,compactionandrougheningthesurfaceifspecial finishistobeprovidedandcuringetc.complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processorbasedPLCwithSCADAenabledreversibleDrum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade)
25First Floor
26Second Floor
27Third Floor
28Fourth Floor
29ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-25 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excludingreinforcementandstructuralsteel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)
30First Floor
31Second Floor
32Third Floor
33Fourth Floor
34Providing and laying Cast in situ/Ready Mix cement concrete in M-25oftrap/ quartzite/ granite/ gneissmetalforR.C.C.Waist slab,andstepsofstaircasesasperdetaileddesignand drawings or as directed including steel centering, plywood/steel formwork,steelprops,laying/ pumping,compaction,finishing unevenandhoneycombedsurfacewithC.M.1:3ofsufficient minimumthicknesstogiveasmoothandevensurfaceor rougheningthesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excludingeinforcement,includingcover block). (Newlylaidconcreteshallbecoveredbygunnybag, plastic,tarpaulinetc.)withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate(Crushed sand VSI Grade)
35First Floor
36Second Floor
37Third Floor
38Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of requiredthicknessincludingsteelcentering,formwork,cover blocks,laying/ pumping,compactingandrougheningthemif special finish is to be provided and curing complete.(Excluding reinforcementandstructuralsteel).withfullyautomaticmicro processorbasedPLCwithSCADAenabledreversibleDrum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade)
39First Floor
40Second Floor
41Third Floor
42Fourth Floor
43Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/ quartzite/ gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required sizeandshapesincludingsteelcentering,formwork,laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is consideredforrenderingunevenandhoneycombedsurface only.Newlylaidconcreteshallbecoveredbygunnybag, plastic,tarpaulinetc. (Woodencenteringwillnotbeallowed.) withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrumTypemixeretc.complete,Withfine aggregate(CrushedsandVSIGrade)
44Providing and fixing in position TMT- FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs,beamscolumns,canopies,staircase,newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars,bindingwithwiresortackweldingandsupportingas required complete.
45100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
46100 Bedded Rural Hospital Second Floor & Trauma CenterSecond Floor
47100 Bedded Rural Hospital Third Floor
48100 Bedded Rural Hospital Fourth Floor
49Providingflyashbrickmasonrywithconventional/ I.S. typefly ash bricks in C.M. 1:6 in foundation and plinth including bailing outwatermanuallystrikingjoints,rackingoutjointswatering and scaffolding etc. complete.
50ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185(Part 3)-1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure includingstrikingjoints,rakingoutjointsandscaffoldingetc. Complete.(The test shall be carried out conforming to IS:6441(Part I)-1972)
51100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
52100 Bedded Rural Hospital Second Floor & Trauma CenterSecond Floor
53100 bedded rural Hospital Third Floor
54100 bedded rural Hospital Fourth Floor
55ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185(Part 3)-1984 in extra fine jointing mortar offixoblockofUltraTechorequivalentinHalfbrickthickwall includingstrikingjoints,rakingoutjointsandscaffoldingetc. Complete.(The test shall be carried out conforming to IS:6441(Part I)-1972)
56100 Bedded Rural Hospital Second Floor & Trauma CenterSecond Floor
57100 bedded rural Hospital Third Floor
58100 bedded rural Hospital Fourth Floor
59Providingandapplyingplaster/ wallpunningwithplasterof paris(withplasterofparismaterial)in10to13millimeter thicknesstopreviouslyplasteredsurface/ oronnewlybrick surface(Excludingroughcastplaster)inallpositionincluding preparingandFinishingthesurfacescaffoldingetc.complete.
60100 bedded rural Hospital First Floor
61100 bedded rural HospitalSecond Floor
62100 bedded rural Hospital Third Floor
63100 bedded rural Hospital Fourth Floor
64Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not lessthan2daysandkeepingthesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mmthickin cement mortar 1:4 finishing the surface by taking out grains and curingforfourteendaysscaffoldingetc.complete.
65100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
66100 bedded rural HospitalSecond Floor & Trauma CenterSecond Floor
67100 bedded rural Hospital Third Floor
68100 bedded rural Hospital Fourth Floor
69Providingfinecementfinish1.5mmthickovergreenplaster surfaceincludingscaffoldingcuringetc.complete.
70Providingandfixingchickenmeshof22gauge,withabout 30cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessarydrillinginconcrete/ B.B.masonryandortyingby binding wire etc. complete.
71100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
72100 bedded rural HospitalSecond Floor
73100 bedded rural Hospital Third Floor
74ProvidingandfixingGRC/ FRPdecorativecornic/ archives/ moulding and other details of various height mentioned belowincluding grooves in wall opening side vertical band architraves, lintels etc as per original detailing including scroll designs, floral design, dentals,fluting item to inclucde checking all surfaces for properlineandlevelscafoldingetccomplete.itemincludes preparing upto 5 samples for architect approval.item to include making of clay model and mould for the decorative cornics and supply of decorative cornis as per approved sample executed in fiber glass material. (Second Floor)
75100 bedded rural Hospital Third Floor
76Providing internal cement plaster 20mm thick in Single coats in cementmortar1:5withoutneerufinish,toconcrete,brick surface,inallpositionsincludingscaffoldingandcuringetc. completeThird Floor)
77Providing patti/band 75mm wide on plastered surface 12mm to 15mmthickinC.M. 1:3lineandlevelincludingneatfinishing scaffolding curing etc. complete.Second Floor)
78100 bedded rural Hospital Third Floor
79Providingandfixingframewith/ withoutventilatorofsizeas specifiedwithCountrycutteakwoodfordoorsandwindows includingchamfering,rounding,rebating,ironholdfastofsize 300mmx40mmx5mmwithoilpainting,etc. complete
80100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
81100 Bedded Rural Hospital Second Floor & Trauma CenterSecond Floor
82100 bedded Rural Hospital Third Floor
83100 bedded Rural Hospital Fourth Floor
84Providing and laying telephone black/Amba White/ Cadburybrown/ Rubyred/ OceanBrowngranitestoneof18to 20mmthickfordoorframe/ dado/ windowboxingetc. OnC.M. 1:6 including filling joints with polymer base filler nosing/ mouldingthesharpedgeswherevernecessary,curing,etc. complete.
85100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
86100 bedded Rural Hospital Second Floor
87100 bedded Rural Hospital Third Floor
88Providing and fixing solid core flush door shutter in double leaf 32mmthickdecorativetypeofexteriorgradeasperdetailed drawings approved face veneers 3mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought ironholdfasts,chromiumplatedfixturesandfastenings,with brassmortiselock,chromiumplatedhandlesonbothsides, and finishing with French Polish etc. complete.
89Providingandfixinginposition,Doubleshutteredaluminium extrudedpowdercoatedopenabledoorofspecifiedsizewith aluminiumdoorframeofpowdercoatedsection101.60x 44.75mm,3.18mmthickandshuttercomprisingofpowder coatedsectionhavingbottomandlockrailofsize150mmx 44.5mm x 3.00mm thick top rails 47.62 x 44.45mm x 3.00mm thick,verticalstyle47.62x44.45mm,3.00mmthickandfor shutter plain glass panes 5mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels forbottompanelsetc.,I.S.I. mark,heavyduty,Hydraulicfloor springof150Kilogramcapacity,havingheavydutyconcealed lock,necessarybeading,glazingclips,PVCgaskets,250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in chargeincludingallmaterials,labours,andequipment etc.complete
90100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
91100 bedded Rural Hospital Second Floor
92100 bedded Rural Hospital Third Floor
93100 bedded Rural Hospital Fourth Floor
94Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90m x 2.40m with aluminium door frame of powder coated section 101.60 x 44.75mm, 3.18mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150mm x 44.5mm x 3.00mm thick top rails 47.62 x 44.45mm x 3.00mm thick, vertical style 47.62 x 44.45mm, 3.00mm thick and for shutter plain glass panes 5mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc., I.S.I. mark, heavy duty, Hydraulic floor spring of 150Kilogramcapacity, having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etc.Complete (Item No. 39.64)
95Providing and fixing 34mm thick moulded door shutter consisting of solid core single leaf flush door of 30mm thickness lipped with 15mm(5mm x 3) thick x 30mm width on one style and top rail and 10mm(5mm x 2) thick x 30mm width on other styleandbottomrails. Theinnerpanelslaminatedwith2mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2, 4, 6 design in different plain and/or prelim colours ononesideafterroutingthemouldeddesignonflushdoors and 2mm plain and/or pre lam PVC on other side using rubber adhesiveonflushdoorandsolventcementadhesiveonthe PVClippingetc.asperdirectionofEngineerinchargeand manufacturersspecificationanddrawingetc.complete.& Trauma center ground floor
96100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
97100 bedded Rural HospitalSecond Floor
98100 bedded Rural HospitalThird Floor
99100 bedded Rural Hospital Fourth Floor
100Providing and fixing mild steel door using 40 x40x4 mm hallow square pipe ,80x40x4 hallow pipe 16 sqr mm pipe rod at intervel of 15cm grill at center leaf with hinges incluidng ionodizing to door
101Providing and Fixing 30MM thick BOTH SIDE PRELAMINATED SOLIDPANELPVCDOORSHUTTERconsistingofframe madeoutofM.Stubesof19guagethicknessand,size19x 19mmforstylesand15x15mmforthetopandbottomrails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC\"C\"channelmadefrom5mm(+/0.25)thickprelaminated sheetofdensity600Kilogram/ cbm,ofsize30mmthickness 70mm width out of which 50mm shall be flat and 20mm shall be taperedin45?angleoneithersideformingstiles and5mm thick, 95mm wide PVC sheet out of which 75mm shall be falt and 20mm shall be tapered in 45 on the inner side to form top andbottomrailand115mmwidePVCsheetoutofwhich 75mm shall be falt and 20mm shall be tapered on both sides to form lock rail.Top, bottom and lock rail shall be provided either side of the panel. An additional 5mm(+/0.25) thick PVC strip of 20mmwidthistobestuckonthebottomsideofthe\"c\" channel prelaminated paneling of 5mm(+/0.25) thick PVC sheet tobefittedinsidetheM.S. framewelded/ sealedtothestyles andrailswith5mm(+/0.25)x30mmPVCsheetbeadingon eithersideandjoinedtogetherwithsolventcementadhesive etc,10mmthickness(5mm(+/0.25)x2nos)20mmwidecross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100mm x 25MM x 2mm using 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares
102100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
103100 bedded Rural HospitalSecond Floor
104100 bedded Rural Hospital Third Floor
105Providing and fixing ISI marked double swing flush door shuttersconformingtoIS :2202(PartI)Non- decorativetype, coreofblockboardconstructionwithframeof1stclasshard wood and well matched teak 3 ply veneering with vertical grains orcrossbandsandfaceveneersonbothfacesofshutters. 30mm thick including ISI marked Stainless Steel L-hinges with necessary screws Fittings & Fixtures per leaf SS kick plates on both sides of the door of 300mm height Heavy Duty satin finish buttSSHinges(100mmx75mmx3mminsize)-4nos.SS finished lever handle with mortise lock-1 One Number Floor spring-1 One Number 100mm x 100mm safety glass at the specified location
106100 bedded Rural Hospital First Floor
107100 bedded Rural HospitalSecond Floor
108100 bedded Rural Hospital Third Floor
109Providingandfixinginposition(asper1868/1982)Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90mm at weight 0.637 Kilogram/One Running Metre. with window framebottomtracksection92x31.75x1.30mmatweight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30mm at weight 0.933 Kilogram/One Running Metre. The shuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18x1.10mmatweight0.469Kilogram/ Runningmetre.and handleandtopsection40x18x1.25mmatweight0.417 Kilogram/ Runningmetre.Asperdetaileddrawingsandas directedbyEngineerinchargewithallnecessaryAluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including5mmthickplainglassandaluminiummosquitonet shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box
110100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
111100 bedded Rural HospitalSecond Floor
112100 bedded Rural Hospital Third Floor
113Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coatingasperdetaileddrawingandspecificationsincluding aluminium frames 80 x 38mm x 1.22mm box type, 5mm thick sheet glass louvers, of approved quality etc. complete.
114100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
115100 bedded Rural HospitalSecond Floor
116100 bedded Rural Hospital Third Floor
117Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
118100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
119100 bedded Rural HospitalSecond Floor
120100 bedded Rural Hospital Third Floor
121Providing and laying vitrified rustic matt stone finish tiles having size590mmto605mmx590mmto605mmof8to10mm thicknessandconfirmingtoIS.15622-2006(GroupBla)of approvedmake,shadeandpatternforflooringinrequired positionlaidonabedof1:4cementmortarincludingneat cementfloat,fillingjoints,curingandcleaningetc.complete.
122100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
123100 bedded Rural HospitalSecond Floor
124100 bedded Rural Hospital Third Floor
125Providing and laying vitrified rustic matt stone finish tiles having size590mmto605mmx590mmto605mmto8to10mm thicknessandconfirmingtoIS.15622-2006(GroupBla)of approvedmake,shadeandpatternfordadoandskirtingin requiredpositionfixedin1:4cementmortarincludingneat cementfloat,fillingjoints,curingandcleaning. etc. complete.
126100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
127100 bedded Rural HospitalSecond Floor
128100 bedded Rural Hospital Third Floor
129Providingandfixingmachinecutmachinepolished18mmto 20mm thick telephone black/ Amba White/ Cat bary brown/ RBI red/ OceanBrowngranitestonefortreadsandrisersofsteps and staircases of approved colour and shade with full moulding andthreegroovedlineforthetreadsonbedof1:4Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
130100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
131100 bedded Rural HospitalSecond Floor
132100 bedded Rural Hospital Third Floor
133Providingandlayinginpositionflooringoftelephoneblack/ AmbaWhite/ Catbarybrown/ Rubyred/ OceanBrowngranite stone of approved shade and size 18mm to 20mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
134100 bedded Rural Hospital First Floor
135100 bedded Rural HospitalSecond Floor
136100 bedded Rural Hospital Third Floor
137Providingandfixingmachinecutmirrorpolished18mmto 20mmthicktelephoneblackgranite/ AmbaWhite/ Catbary brown/ RBIred/ OceanBrowngranitestonepartitionwithfull moulding the edges etc. complete . Both side polish
138100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
139100 bedded Rural HospitalSecond Floor
140100 bedded Rural Hospital Third Floor
141Providingandlaying18mmthickADONIBROWNLEATHER FINISH stone for flooring, machine cut in required size, approvedshade,colorandtexturelaidusingwhitecement slurryover20mm(average)thickbaseofcementmortar1:4 followedbylaying,fixingandjointedwithwhitecementslurry mixedwithmatchingpigment,includingrubbingandcuring mouldingandpolishingtoedgetogivehighglossfinishetc complete. The application rate for tile adhesives shall be as per manufacturer\"srecommendations.asperdetaildrawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levelsandasdirectedbyEngineerincharge.Complete.a) Flooring
142Providingandlaying18mmthickADONIBROWNLEATHER FINISH stone for flooring, machine cut in required size, approvedshade,colorandtexturelaidusingwhitecement slurryover20mm(average)thickbaseofcementmortar1:4 followedbylaying,fixingandjointedwithwhitecementslurry mixedwithmatchingpigment,includingrubbingandcuring mouldingandpolishingtoedgetogivehighglossfinishetc complete. The application rate for tile adhesives shall be as per manufacturer\"srecommendations.asperdetaildrawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levelsandasdirectedbyEngineerincharge.Complete.a) Skirting
143ProvidingandfixingP.V.C. Rainwaterpipesof110mmouter diameter and having wall thickness of 2.2 to 2.7mm confirming to I.S. 13592-1992 including proper rainwater receiving recess withP.V.C.plug,bend,necessaryfittings,suchas,offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clipsofapprovedqualityandOne Number,filingthejointusing rubbergasketwithsolventcementandproperlyrestingthe shoe of pipes on C.C. or masonry blocks, including necessary scaffoldingandmaintenancefor3yrsforanyleakagesor dislocationsofpipes.AlltheP.V.C.fittingsandadditional2 piecesocketclipsshallbegotapprovedfromengineerin charge etc. complete. Fourth Floor)
144Trauma Center Second Floor
145Providingandfixing75mmdiastabiliserpipe/ P.V.C. soilvent/ wastepipeandwithnecessaryfixturesandfittingsuchas bends, tees, single junctions, slotted vent, clamps etc. complete
146Trauma Center First Floor
147Providing and fixing 100mm dia stabiliser pipe/ P.V.C. soil vent/ wastepipeandwithnecessaryfixturesandfittingsuchas bends, tees, single junctions, slotted vent, clamps etc. complete.
148Trauma Center First Floor
149Providing and fixing on walls/ceiling/floor 15mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
150100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
151100 bedded Rural HospitalSecond Floor
152100 bedded Rural Hospital Third Floor
153Providing and fixing on walls/ceiling/floor 20mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
154100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
155100 bedded Rural HospitalSecond Floor
156100 bedded Rural Hospital Third Floor
157Providing and fixing on walls/ceiling/floor 25mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
158100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
159100 bedded Rural HospitalSecond Floor
160100 bedded Rural Hospital Third Floor
161Providing and fixing on walls/ceiling/floor 32mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
162100 bedded Rural Hospital First Floor
163100 bedded Rural HospitalSecond Floor
164100 bedded Rural Hospital Third Floor
165Providing and fixing on walls/ceiling/floor 50mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
166100 bedded Rural Hospital First Floor
167100 bedded Rural HospitalSecond Floor
168100 bedded Rural Hospital Third Floor
169Providing, laying and fixing, jointing Eco-drain 110mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessaryexcavation,trenchrefillingwithselectiveexcavated material etc. complete.
170Providing, laying and fixing, jointing Eco-drain 160mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessaryexcavation,trenchrefillingwithselectiveexcavated materialetc. complete.
171Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
172Providing and laying concrete pipes of I.S.NP. class of 300mm diameterinproperline,levelandslopeincludingnecessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
173Providing and fixing sink cock with regular swinging spout(Wall/ floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/ MinuteofJaquar/ Cera/ Hindware/ Perrywareorequivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.(Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.)
174100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
175100 bedded Rural HospitalSecond Floor
176100 bedded Rural Hospital Third Floor
177Providing and fixing push cock(Self closing tap) symet type of 20mmdia.includingnecessarysocket,testingetc.complete.
178100 bedded Rural Hospital First Floor
179100 bedded Rural HospitalSecond Floor
180100 bedded Rural Hospital Third Floor
181ProvidingandfixingC.P. 2WayBIBcockwithwallflangeof approvedmakeincludingnecessarysockets/ unionnutetc. complete as directed by Engineer in charge.
182100 bedded Rural Hospital First Floor
183100 bedded rural HospitalSecond Floor & Trauma CenterSecond Floor
184100 bedded Rural Hospital Third Floor
185Providing and fixing C.P. BIB cock with wall flange of approved makeincludingnecessarysockets/ unionnutetc. completeas directed by Engineer in charge.
186100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
187100 bedded Rural HospitalSecond Floor
188100 bedded Rural Hospital Third Floor
189Providingandfixing15mmdia.screwdownbib/ stoptapof brass including necessary socket union nut complete.
190100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
191100 bedded Rural HospitalSecond Floor
192100 bedded Rural Hospital Third Floor
193Providingandfixing25mmdia.screwdownbib/ stoptapof brass including necessary socket union nut complete.
194100 bedded Rural Hospital First Floor
195100 bedded Rural HospitalSecond Floor
196100 bedded Rural Hospital Third Floor
197Providing and fixing Autoclosing pillar cock of pressmatic tap of approvedmakeorequivalent including allfixtures,fittingsetc. complete.
198100 bedded Rural Hospital First Floor
199100 bedded Rural HospitalSecond Floor
200100 bedded Rural Hospital Third Floor
201Providingandfixingwallmixerwithoverheadshower,shower arm, hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent makeincludingallnecessarypipes,fittingsetc.completeas directed by Engineer In Charge.(Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.)
202100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
203100 bedded Rural HospitalSecond Floor
204100 bedded Rural Hospital Third Floor
205Providing and fixing 450mm x 550mm size superior type Belgiummirrorwith16mmdia.nickelplatedtowelrodetc. complete.
206100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
207100 bedded Rural HospitalSecond Floor
208100 bedded Rural Hospital Third Floor
209Providing and fixing 15cm rigid PVC Nahani trap including PVC grating, bend, connectingpiece of UPVC pipe up to the outside face of wall, making the good damaged surface and testing etc. complete(PriorapprovalofsampleandbrandbyEx. Engr. is necessary before use)
210100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
211100 bedded Rural HospitalSecond Floor
212100 bedded Rural Hospital Third Floor
213ProvidingandfixingOrissaPanofsize580x445x260mmwith approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend andnecessarypipeconnection,etccomplete. Asdirectedby Engineer in charge.
214100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
215100 bedded Rural HospitalSecond Floor
216100 bedded Rural Hospital Third Floor
217ProvidingandfixingwhiteOpalseriesEuropeantypewall- hung, of size 400mm x 370mm x 575mm with approved make flushvalveincludingsoilpipe,ventpipeuptooutsidefaceof wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
218100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
219100 bedded Rural HospitalSecond Floor
220100 bedded Rural Hospital Third Floor
221ProvidingandfixingOvalTypeUnderCounterWashHand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside faceofthewall,havingTelephonicBlack/ ColourGraniteof 180mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
222100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
223100 bedded Rural HospitalSecond Floor
224100 bedded Rural Hospital Third Floor
225ProvidingandfixingWhiteGlazedEarthenwarefullstalltype Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia.P.V.Cflushpipewithfittingsandflushingarrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
226100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
227100 bedded Rural HospitalSecond Floor
228100 bedded Rural Hospital Third Floor
229Providing and fixing White Glazed Earthenware Squatting plate(Ladies Urinal) with P.V.C.flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
230100 bedded Rural Hospital First Floor
231100 bedded Rural HospitalSecond Floor
232100 bedded Rural Hospital Third Floor
233Providing and fixing H.D.P container one piece moulded water tankmadeoutoflowdensitypolythylerandbuiltcorrugation includingofdeliveryuptodestinationhoistingandfixingof accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20, 000 litresThird Floor)
234Trauma Center Second Floor
235Providing, constructing and fixing 450mm dia. Inspection chambermadeupofPolypropylene/ polyethylenematerialof thickness3.5mmandheightof388mmwith160or200mm main inlet(s) outlet and 110 and/ or 160mm branch inlets, with 450mm dia. Ultra shaft pipe of HDPE material having height of 460mm, having R.C.C. cover and frame fixing in 150mm thick in c.c.1:2:4,havingcrushedsandbedof150mmthickofsize 750mmdia.Includingexcavationandrefillingthesidesof chamber by sand crushed cushioning 150mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.& Trauma Center
236Providing, constructing and fixing 600mm dia. Inspection chamber made up of Polypropylene/polyethylene material Having315mmdiameterinlet(s)/ outletsandwitheccentric reducersasperrequirementtoconnect160mmand200mm pipeshavingthicknessof5mmand600mminheight,with inbuilt shaft achieve the invert depth as per site condition of wall thicknessof5mmhavingR.C.C.coverandframefixingin 150mm thick in c.c.1:2:4, having crushed sand bed of 150mm thick of size 750mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150mm thickness,connectingallrequiredUPVCfittingswithrubber lubricant etc.complete.
237Providing and fixing 900mm high S.S.304 Grade Stainless steel railingwith40mmdiameterand1.5mmthickattop,40mm diameterand1.5mmthickverticalsupportsspacedat1.5m centertocenterand8mmthicktoughenedglassincluding fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
238100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
239100 bedded Rural HospitalSecond Floor
240100 bedded Rural Hospital Third Floor
241Providingandapplyingimpression24carratLuxurypaintof approvedmake&approvedbrandEmulsionpainttointerior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic puttyandAcrylicprimercoatsincludingscaffolding,preparing the surface. etc. complete(Low VOC).
242100 bedded Rural Hospital First Floor
243100 bedded Rural Hospital Second Floor
244100 bedded Rural Hospital Third Floor
245100 bedded Rural Hospital Fourth Floor
246Providing andapplyingharmmeldezzlytexturedpaint includingtwocoatofwallputteyasdirectedbyengineer incharge etc complete
247100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
248100 Bedded Rural Hospital Second Floor & Trauma CenterSecond Floor
249100 bedded Rural Hospital Third Floor
250100 bedded Rural Hospital Fourth Floor
251Providingcementbasedwaterproofingtreatmentto terraces(Indianwaterproofingoralike)withbrickbatslaidin required slope to drain the water for any span after cleaning the basesurface. Applyingacoatofcementslurryadmixedwith approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compoundandfinallytopfinishingwithaverage20mm.thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Marking finished surface with false squares of 300mm x 300mm. making thejunctionsattheparapetroundedandtaperedtopfor required height, with drip mould at the junction of plaster and parapetandcuringandcovering10yearsGuaranteeagainst leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Third Floor)
252Trauma Center Second Floor
253ProvidingwaterproofbeddingforflooringofBathandWC 25mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specificationsforperbagofcementincludingleveling,curing and covering 10 years guarantee on court fee stamp paper of Rs.500/-including ponding test etc. complete.
254100 Bedded Rural Hospital First Floor & Trauma CenterFirst Floor
255100 bedded Rural HospitalSecond Floor
256100 bedded Rural Hospital Third Floor
257Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index(SRI) 108(with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371respectively,VOClessthan10cc/ gm.Thecoating thicknessandthemethodologyofapplicationshallstrctlyas per manufacturer\"s specifitions and as approved by engineer in charge. Surfacepreparationincludescleaningwithmetalwire brushtoremovealldust,fungusetc,washingwithwaterall complete.Thecontractorshallgiveguaranteeforthe performanceofSRIandalsothedurabitityofcoating,all completeasperdirectionofEngineer- in- incharge. Fourth Floor)
258Trauma Center Second Floor
259ProvidingandfixinginpositionUPVCultravioletstabilized 110mmouterdiametercowldomeconfirmingtoI.S.-4985 including making joints with solvent cement etc. complete Fourth Floor)
260Trauma Center Second Floor
261Providingandconstructinggranitekitchenplatformwithfixing ofstainlesssteelsink600mmx450mmsizeasperdetailed drawingincludingverticalbothsidepolishedkadappahstone 25 to 30mm thick supports with kadappah top 35 to 40mm thick and polished granite 16 to 20mm top with side strips of granite atfrontandbothsidesofplatformraisedwithtwovertical granitesupports15cmheightandtopgraniteof75x40cm including cutting, opening for sink of required size in kadappah aswellasgraniteetc.complete. (Platformtopsize5.00mx 0.60m and height is 0.75 m)
262100 bedded Rural Hospital First Floor
263100 bedded Rural HospitalSecond Floor
264100 bedded Rural Hospital Third Floor
265RWH-Shallow Percolation Pit providing, constructing 2.0m deep shallowdepthpercolationpitcomprisingof1.0mdiapre- cast RCCrings,300mmthicksidefillingaroundoutsideofRCC rings(annularspace)with40mmsizebouldersincludingfilling ofpercolationpitupto0.5mdepth(frombottomup)with 25-75mmcleanwashedgravelsfollowedby0.5mdepthof 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate(natural sand/crushed sand VSI grade finely washedetc.)includingnetlonmeshbetweeneachgravel/ fine aggregate(natural sand/crushed sand VSI grade finely washed etc.)medialayerincludingcoveringwithRCCslab,manhole frame & cover, PVC rungs etc. including arrangement for inlet & outletpipe,excavation&backfillingasshowninthedrawing. Therateshallbeinclusiveofalllabour,material,wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels.Allmaterialshouldbeofapprovedmake.Allworks complete as per the drawing, technical specification and direction of the Engineer in charge
266Providing and fixing factory made Hydraulically pressed Mechanicallyvibratedandcompactedprecastinterlocking cementconcretepavingblocks80MMthickinM-40gradeof approved size and shape for City streets, small/medium market roads,lowvolumeroads,utilitycutsonarterialroadsetc. as specifiedandasperIS15658:2006includingcostofall materials,manufacturing,curing,transportationofblocksto work site including loading, unloading and stacking as directed, layingpavingblocksinpositionoverpreparedbedofnatural sand/ crushedsandof50mmthicknessincludingnecessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
267Providing and fabricating structural steel work in rolled sections likejoists,channels,angles,teesetc.asperdetaileddesign and drawings or as directed including cutting, fabricating, hoisting,erecting,fixinginpositionmakingriveted/ bolted/ welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Third Floor)
268Trauma Center Second Floor
269Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The systemwithcompleteassemblyofcoextrudedUVprotected multicellpanelsincorporatedintoacompletesystem.Co- extrudedUVprotectedpolycarbonatepanelsystemofmin 16mmthickof1200mm(min.)widthwithangulardaylighting concept.Panelsshallhaveminimumsevenlayersinatruss bridgedesignforhigherflexibility&strength.Panelswith opaque and translucent clear combination as per required lux levelanddesignrequirementswithallfixingaccessoriesto ensurebestperformanceforwinduplift,vibration,oilcanning andvisualappearance.PanelsshallhaveanadditionalIR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors withdoubletoothgriplocklockingmechanismandwillbe secured on MS structure(will be paid Separately) with 3 One Numbers self- drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N(7KN) tested as per ISO 6892:1998 andIS1608:2005,asperdesignrequirement.Panelsmust satisfy Dart drop impact test as per IS 14443-97 shall show no signofbreakageonPolycarbonatesheetswhichhavebeen exposedtoUVforamin. of500HoursasperASTMG155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K asperENISO10077-2:2018.Panelshallbewithadditional Endcap/ AluminiumU/ Fprofile/ GlazingBarforendsas required.PanelshallbefixedoverMSstructuralsteel/ MS purlin(paid separately) conforming to the detail technical specificationsasperapprovedarchitecturaldrawings. Trained and factory authorized labour with supervision to complete the entirepanelinstallationasperdrawing&directionofthe engineerincharge. Colour: AsperapprovalThe16mmthick panels shall be used for a roofing height of upto 15 mtrs.Fourth Floor)
270Cnc cutting ms jail 4mm thick with powder coating
271100 bedded Rural Hospital First Floor
272100 bedded Rural HospitalSecond Floor
273100 bedded Rural Hospital Third Floor
274100 bedded Rural Hospital Fourth Floor
275ProividnganFixing6mmthickToughenGlassPannelingwith ST Series Green Reflective Cool Glass on a Frame Aluminium sectionofSize70mmx53mm forGreenBuilding Concept and additionalFrameForfireingAlumniumFrameEtcComplete RateapprovedbySEPWDNandedVideLetterNo2020-21/ tender/298 Date 15/1/2021
276100 bedded Rural Hospital First Floor
277Providing and fixing lioghtening conductor system comprising of erectingAir- Terminationconsistingoftubularcopperrodof 25mmdia.1.2mmthickwithmultiplepointshead1.2mt. long(Heavy Duty) welded or clamped to G.I. pipe pole B grade 50mmdiaofrequiiredlengthwithM.S.roundbnaseplate25 Cmdiamand10mmthickatbottomembededincement concrete1:3:6dfoundationofsize45cmdiamx45cmHeight and providing earthing with copper earth plate of size 60 x 60 x 0.3cmswithcadmiumplatednutboltstofixearthingstrip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried ineartheuptoearthlingplatereminingportionaboveground levelforwateringandrefillingcomcpeteNote- Copperstrip fropm lightening conductor is not considered in this item. Fourth Floor)
278Trauma Center Second Floor
279Providing and fixing in position alluminium strips of size 50mm x3mmfornosingthestepsincludingfixingwithscrewsand raval plugs, bending and cutting to the required shape and size, finishingwithpaint,necessarymortarbeddingof1:3cement mortar to get exact line and level including watering and curing etc.complete
280100 bedded Rural Hospital First Floor
281100 bedded Rural HospitalSecond Floor
282100 bedded Rural Hospital Third Floor
283Supply, fixing and installation of 4mm thick Aluminium Composite Panel(ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel(ACP) should be made out of thermoplastic core of low-density polyethylene LDPE(100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE-5000 series, each not less than 0.50mm thick, total thickness of aluminium composite panels not to be less than 4mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than(26 +-2) micron(containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface(facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face(peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900mm X 1200mm and fixed to the building structure as per design through 50mm X50mm X5mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge.(Prior permission of S.E. is necessary before inclusion of this item in estimate) (Item No. 51.235, First Floor)
284100 bedded Rural HospitalSecond Floor
285100 bedded Rural Hospital Third Floor
286Providingandfixingboarddisplayinginformation,suchas \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20mx0.90msizemadeout18gauge(1.25mm)thickmild steelsheetpaintedwithonecoatofZincchromatestoving primerandtwocoatsofenamelpaintonfrontsideandgrey stove enamel on back side and border/messages/symbols etc. withapprovedcolourshadepaintcomplete,onM.S.angleof size35x35x3mmframewithproperlycrossbracedM.S. anglesofsize35mmx35mmx3mmdulypaintedincludingTwo M.S. angle iron posts of size 65mm x 65mm x 6mm, 3.65m long paintedwithalternateblackandwhitebandsof25cmwidth including all fixtures etc.and fixing the boards in 1:4:8 concrete blockofsize60cmx60cmx75cmincluding,excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
287Construction of granular sub- base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to worksite,spreadinginuniformlayerswithmotorgrader/ Paveron preparedsurfaceandcompactingwithvibratoryrollertoachievethe desired density, complete as per clause 401 --Plant Mix Method and Grading-I Material
288ConstructionofdryleancementconcreteSub- baseoveraprepared sub-grade with coarse and fine aggregate(natural sand/VSI grade finely washedcrushedsand)conformingtoIS:383,thesizeofcoarse aggregatenotexceeding25mm, ,cementcontentnottobelessthan 150kg/ cum,optimummoisturecontenttobedeterminedduringtrial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site withallleadsandlifts,laidwithapaverwithelectronicsensor/ by suitablemeansasapprovedbyEngineer- in- charge,compactingwith vibratory roller, finishing, curing and including preparation of sub-grade surfaceifrequiredetc. complete. withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete.
289Providingandlayingin- situM30Gradeunreinforcedplaincement concretepavementoverapreparedsubbasewith43gradecement, coarse and fine aggregate(natural sand/VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixedinaTiltingtypeConcreteMixerasperapprovedmixdesign, admixtures, spreading, laying compacting and finished in a continuous operationwithoutpavermachine,finishingtolinesandgradesas directedbyEngineer- in- chargeandcuringbycuringcompound/ by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other methodapprovedbyEngineer- in- charge.withfullyautomaticmicro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete.
290ProvidingandfixinginpositionTMTFE500,32mmdiadowelbars precoated with anticorrosive epoxy paint of required Dia. 60cms. Long and at 30.00cm.C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with properalignmentbyusingproperlydesignedassemblyofBulkheads lubricating half length with bituminous paint as directed etc. complete.
291ProvidingandfixinginpositionTMTFE500,tiebarsprecoatedwith anticorrosive epoxy paint of 12mm dia. 70cms.long and at 30.00cm. C/C andwhereverdirectedincludinghandling,straighteningwrappingwith paperofapprovedqualityforhalflength,necessarycutting,handling, straightening,supportedbyassemblyofTMTFE500,chairswith proper alignment etc. complete.
292Cutting transverse contraction joints 3 to 4mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studdedsawwithin48hoursofcastingofbay/ slabetc.complete includingsubsequentwideningofthegroove8to10mm. wideattop havingdepthof15mm.asdirectedbyEngineerincharge.
293Providing to contraction joints polysuphide sealent(Pouring grade) MetreconfirmingtoBS :5212-1989intosawedgroovewidenedattopfor sealentreservoirofspecifiedsizeandshapeasperdetaileddrawing including fixing Polyethylene foam backer rod of required diameter(appraox.25% larger than the initial 3mm.to 4mm.joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaningthejointswithwaterjet/ aircompressorandallowingjointto become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints(15mm. deep x 8mm.wide)
294Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
295Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.
296ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-20 oftrap / granite/ quartzite/ gneiss metal for R.C.C.columns as perdetaileddesignsanddrawingorasdirectedincludingsteel centering,formwork,coverblocks,laying/ pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or rougheningifspecialfinishistobeprovidedandcuringetc. complete.(Excluding reinforcement and structural steel).with fully automaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc.complete.Withfineaggregate(CrushedsandVSIGrade) , First Floor)
297Trauma CenterSecond Floor)
298ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-20 of trap/ granite/ quartzite /gneiss metal for R.C.C.beams and lintelsasperdetaileddesignsanddrawingsorasdirected including steel centering, formwork, cover blocks, laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobe providedandcuringetc. complete. (Excludingreinforcementand structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade)First Floor)
299Trauma Center Second Floor)
300ProvidingandlayingCastinsitu/ ReadyMixcementconcrete M-20oftrap/ granite/ quartzite/ gneissmetalforR.C.C. slabsand landingsasperdetaileddesignsanddrawingsincludingsteel centering,formwork,coverblocks,laying/ pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or rougheningifspecialfinishistobeprovidedandcuringetc. complete,(Excluding reinforcement and structural steel).with fully automaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc.complete.Withfineaggregate(CrushedsandVSIGrade) First Floor)
301Trauma CenterSecond Floor
302Providing and laying Cast in situ/Ready Mixcement concrete M-20 oftrap/ granite/ quartzite/ gneissmetalforR.C.C.chajjaasper detailed design and drawings including steel centering, formwork, coverblocks,laying/ pumping,compactingandrougheningthe surfaceifspecialfinishistobeprovidedandcuringcomplete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Typemixer/ concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(CrushedsandVSIGrade) First Floor)
303Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ quartzite/ granite/ gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directedincludingsteelcentering,formwork,steelprops,laying/ pumping, compaction, finishing uneven and honeycombed surface withC.M. 1:3ofsufficientminimumthicknesstogiveasmooth and even surface or roughening the surface if special finish is to beprovidedandcuringetc.complete. (Excludingeinforcement, includingcoverblock). (Newlylaidconcreteshallbecoveredby gunnybag,plastic,tarpaulinetc.)withfullyautomaticmicro processor based PLC with SCADA enabled reversible Drum Type mixer/ concreteBatchmixplant(Panmixer)etc.complete.With fineaggregate(CrushedsandVSIGrade)First Floor)
304Providing and laying Cast in situ/ Ready Mix cement concrete in M-20oftrap/ granite/ quartzite/ gneissmetalforR.C.C.copingto plinthorparapetandsillofdoorsandwindowsmouldedasper detaileddrawingsorchamferedasapprovedbytheEngineer including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finishing and roughening them if special finish istobeprovidedandcuringcomplete. (Excludingreinforcement andstructuralsteel).withfullyautomaticmicroprocessorbased PLCwithSCADAenabledreversibleDrumTypemixer/ concrete Batchmixplant(Panmixer)etc.complete.Withfine aggregate(CrushedsandVSIGrade) Second Floor)
305Providing and laying Cast in situ/ Ready Mix cement concrete in M-20oftrap/ granite/ quartzite/ gneissmetalforR.C.C.pardiof required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finishing and rougheningthemifspecialfinishistobeprovidedandcuring complete.(Excluding reinforcement and structural steel).with fully automaticmicroprocessorbasedPLCwithSCADAenabled reversible Drum Type mixer/ concrete Batch mix plant(Pan mixer) etc.complete.Withfineaggregate(CrushedsandVSIGrade)First Floor)
306Trauma CenterSecond Floor)
307Providingandapplyinggypsumplaster(withGypsummaterial) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface(Excludingroughcastplaster)inallpositionincluding preparingandFinishingthesurfacescaffoldingetc.complete. First Floor)
308Trauma CenterSecond Floor)
309Supply and Installation of translucent roof with DPI Flux standing seammulticellpolycarbonatepanelsystem.Thesystemwith complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co- extruded UV protected polycarbonatepanelsystemofmin12mmthickof900mm(min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performanceforwinduplift,vibration,oilcanningandvisual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin withsnaponconnectorswithdoubletoothgriplocklocking mechanismandwillbesecuredonMSstructure(willbepaid Separately)with3One Numbersself- drillingscrews&trapezoidSS fastenersholdingthebaseofthestandingseamofferingbest stability having a pull- out load of min. 7000N(7KN) tested as per ISO6892:1998andIS1608:2005,asperdesignrequirement. PanelsmustsatisfyDartdropimpacttestasperIS14443-97 shallshownosignofbreakageonPolycarbonatesheetswhich have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin(paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalentThe12mmthickpanelsshallbeusedforaroofing height of upto 15 mtrs.
310Providing and fixing 90cm x 60cm Marble plate engraving 10cm. heightletter,figuresincludingpaintingthelefters/ figureswith approved colour and shade complete
311Providingearthworkinembankmentwithapprovedmaterialsobtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves,grades§ion,wateringandcompactionwithvibratoryroller with V- Sat attachment to achieve not less than 97 % of standard proctor densityetc.complete(MaterialobtainedfromOthersources)
312Dismantlingbrickmasonryinlimeorcementmortarandstackingthe materils as directed with all leads, lifts etc.
313Providing and laying in situ/ready mix/ready mix M10 cement concrete of trap/granite/quartzite/gneiss metal in foundation including necessarycentering,formwork,bailingoutwater,compactingand curing etc. complete.(with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant(pan mixer) with natural/artifical sand)
314Providing and laying in situ/ ready mix M-20 plain cement concrete of trap/ granite/ quartzite/ gneissmetalforcastincitupiers,abutment, returns, wings etc. including provision of \"V\" shaped false joints to form suitablepanelsonthefacestoapprovedesignwithcompactingby vibratingandcuringcomplete,includingplywood/ steelformwork centering(excludingdewateringbymeansofpump)andincluding baillingoutwaterandcuringfinishinginCM1:3etc.complete.as directed by engineer in charge basic rate shall be increased for height above 5.00m in followinh manners(a) Height upto 5 M.(With Concrete Mixer)Withfineagreegatesofrequiredspecifications(VSIsandfinely washed etc) i) Height up to 5 m, normal rate. ii) Height 5 to 7.50 m, add5percentextraoverbasicrate.iii)Height7.50to10m,7.50 percentextra.iv)Over10mHeight,add10percentextraforevery 2.50m rise.
315Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete.
316Providing and laying weep holes of 100mm diameter PVC pipes as per drawingforabutmentreturns,returnwallsetc.Complete.
317ELECTRICAL Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
318Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
319Supplying and erectingHMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
320Supplying and laying HMS PVC conduitFRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
321Supplying and erecting HMS PVC conduit FRLS grade25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
322Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
323Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
324Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
325Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
326Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
327Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
328Supplying and erecting mains with 2 x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
329Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
330Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
331Supplying and erecting mains with 4X10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
332Supplying and erecting mains with 1X10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
333Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV
334Supplying and erectingCeiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
335Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
336Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
337Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete.
338Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
339Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.
340Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
341Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
342Supplying and erecting PVC Surface modular switch box with double mounting plate for 4module duly erected.
343Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected.
344Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
345Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
346Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
347Supplying and erecting 16/20/25A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
348Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW
349Point wiring for ceiling fan concealed type in min 20 mm FRLSH grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW
350Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
351Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
352Supplying and erectingLED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
353Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
354Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
355Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output of Min. 2200 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty.
356Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
357Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.
358Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
359Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
360Supplying Pedestal fan 400 mm.230 Volts 50 cycles oscillating type complete with guard and regulator 3 meter of flexible wire and hand shield type 3 pin plug top.
361Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
362Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
363Supplying and erecting Energy Saving BLDC Ceiling fan without IR remote control 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
364Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
365Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.(465X06=279 Mtr Say 280 Mtr )
366Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
367Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
368Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC
369Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
370Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
371Supplying and erecting switch disconnector fuse (SDF) 415V, 63A,with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation(without HRC fuse)
372Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
373Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
374Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
375Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB
376Supplying&erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB
377Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
378Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
379Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
380Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TPMCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
381Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
382Providing & erecting 4 Pole MCCB, 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
383Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu),adjustablethermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
384Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
385Supplying, fixing and commissioning 4 poleRCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
386Supplying, fixing and commissioning 4 pole RCBO 63 A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO
387Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB
388Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways four pole outgoing,up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
389Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
390Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway andDB.
391Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
392Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
393Supplying and erecting terminal spreaders suitable for 4up to100A MCCB (Set of 8)
394Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
395Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
396Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
397Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
398Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core185 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
399Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. Allum.conductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
400Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core4sq mm copper conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
401Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
402Supplying & erectingG.I. pipe ‘A’ class40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
403Providng earthing with galvanized iron earth plate size 60x60x0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
404Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP .(25X4=100 Mtr i. e 100Kg )
405Providing LAN -VAN wiring to 100 Beded (Upgradation 30 to 100 Beded) Rural Hospital at Mehkar Dist.BuldhanaSupplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
406Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
407Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
408Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC
409Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
410Supplying, fixing, and configuring 24 ports, POE switchin provided rack as per specification No. WG-NWC/ENS
411Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
412Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
413Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
414Supplying and fixing 24 ports light guide unloaded interconnect unit, wall mounted type, with adapter panel for termination of optical fibre cables onwall in provided U rack complete as per specification no. WG-NAS/ LIU
415Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
416Providing Air Conditioner to 100 Beded(Upgradation 30 to 100 Beded) Rural Hospital at Mehkar Dist.BuldhanaSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
417Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TRcapacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
418Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
419Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
420Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete withtemperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
421Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
422Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete.
423Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
424Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
425Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
426Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
427Providing Street Lights in the premises of 100 Beded (Upgradation 30 to 100Beded) Rural Hospital at Mehkar Dist.Buldhana Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 nox 0.25 mm dia)3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (7X31= 217 Mtr )
428Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.
429Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation.
430Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB
431Supplying, erecting & terminatingFRXLPE armoured cable 4 core6sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
432Supplying & erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
433Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
434Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
435Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
436Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
437Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP
438Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP (G.I.Strip 25x3 [email protected] Kg/Mtr.(31x1+2x5=31+10 Total 41 Mtr i.e.41x0.6=24.6Kg. Say 25 Kg ))
439Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete..( V=30 X 0.30X 0.9 = 8.10 CuM.)
440Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete (pole muffing or any other purpose).( V= 30 X 0.3 X 0.4 = 3.60 Cu. Mtr)
441MakingM- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as10 T/sq.m at 1.5 m depth including supply of steel, concrete,excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal GI pole).
442Supplying and erecting ISI mark GI pipe 50 mm. dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
443Providing Roof top on grid Solar Power Plant & Water Heater to 100 Beded(Upgradation30 to100 Beded) Rural Hospital at Mehkar Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia).
444Supplying, installing, testingand commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC
445Supplying and erecting 16/20 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC),thickness 2.0 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
446Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
447Supplying, installing, testing and commissioning of20 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 60 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnectingwires / cables up to solar ON GRIDinverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 yearsincluding net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
448Supplying, installing, testing and commissioning of Monoblock Heat pump, having dimension:1012x713x1700 (mm), Input power:875 W,400 V,3 Ph, 50 Hz,Output power: 3680 W having hot water temperature range 35°C to 75°C and ambient temperature range for max. efficiency 7°C to 43°C, with glass lining hot water tank of 455 ltr. and min.194 Kg at rated pressure 10 bar with two emergency heating elements operated on three operational mode: Efficiency mode,Hybrid turbo mode and Standard mode with Adaptive Energy System (AES), LED display with necessary accessories complete with 5 years ON-SITE warranty.
449Providing and fixing high-density polyethylene(HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacityup to 20000 litres.
450Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
451Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 80/100Ain provided distribution board.
452Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
453Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
454Supplying and erecting expanded metal jali enclosure made from GI square mesh 15SWGhaving20/25 mm squares,properly fixed/welded and duly painted with one coat of red oxide and two coats ofsilver/enamelpaint complete. (size of jali or enclosure to be specified in the estimate.)
455Supplying anderectingLT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power completewithzeroadjustment&testcertificatefrom manufacturer erected on providedM.S. box and connected to CTs.
456SupplyinganderectingAC three phase LT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz,with backlitLCD display, optical port& RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer.
457Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
458Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm stone metal duly plastered with necessary curing for complete.(pole muffing or any other purpose).
459Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
460Supplying and erecting 25 mm dia. gun metal sluice valve at position with necessary materials complete.
461Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete.
462Prov CCTV camera systemto 100 Beded (Upgradation 50 to 100Beded) Rural Hospital at Mehkar Dist. Buldhana Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
463Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
464Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit
465Supplying and erecting 10m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
466Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC
467Supplying, fixing, and configuring 8-ports managed gigabit,Layer-2 switch,10/100/1000 base-T,POE smart switch plus 2 SFP erected in provided rack complete.
468Supplying, fixing, and configuring 24 ports, POE switchin provided rack as per specification No. WG-NWC/ENS
469Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
470Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA
471Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
472Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 0.5 hrs. PWM & IGBT based,with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS
473Supplying and erecting 12V/80Ah to 88Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
474Supplying& erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR :minimum 120 dB Wide Dynamic Range, ONVIF profile conformant,minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm,horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm,horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/ SDHC /SDXC card slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1.Image Settings : Rotate mode, saturation,brightness,contrast,sharpness, gain, white balance. Image Enhancements: Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60°C) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTPdisabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM
475Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports,ANR Technology,8 SATA interfaces for 8HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, support multibrand network Cameras, ON VIF conformance, Multiple network monitoring: Web viewer support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR
476Supplying& erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S,maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB,MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
477Supplying& erecting 43\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
478Providing Fire Fighting & Fire Alarm System to 100 Beded(Upgradation 30 to 100 Beded) Rural Hospital at Mehkar Dist.BuldhanaCarrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
479Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates,rods,bars,MS pipes,etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
480Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
481Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core25sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
482Supplying & erectingG.I. pipe‘A’ class25 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
483Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
484Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
485Providng earthing with galvanized iron earth plate size 60x60x0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
486Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
487Supplying & erecting flat flexible 3 core 10 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
488Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP
489Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/JP
490Supplying, installation, testing and commissioning ofmain fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speedsuitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
491Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accesso. wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows: a. Main fire pump(MFP) having capacity of 37kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification.8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP =(1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECPFor main electric motor driven fire hydrant system pump of 37kW capacity & relevant capacity jockey pumpFor main electric motor driven fire sprinkler system pump of 45kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode,For main electric motor driven fire hydrant system pump of 37kW capacity & relevant capacity jockey pump add Rs.26217 /-… For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode)& jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs.68381/-The control for diesel engine comprises ofautomatic manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. (182320+26217+68381= Rs.276918 /-)
492Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
493Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
494Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
495Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
496Supplying and erectingG.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP
497Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
498Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
499Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern,PN16 pressure rating, SS screen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no.FF-VL/ELS
500Supplying and erecting 75/80 mm dia.cast iron double flange butterfly valve of size complete with PN16 pressure rating,as per specification no.FF-VL/BFV
501Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
502Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
503Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
504Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
505Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
506Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
507Supplying and erecting stainless steel singles outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
508Supplying and installing one piece moulded HDPE/ fibre water tank for negative suction only,having capacity 1000 litres fitted with necessary accesso. complete as per specification no. FF-FFA/PT
509Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
510Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
511Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
512Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
513Supplying and erecting300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT
514Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FFFFA/ARV
515Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
516Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve,G.I.nipple,elbow, etc completeas per specification no. FF-FFA/PS
517Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size (400x400x400)mm or hose pipe box of size (600 x 600 x 200) mm made from min.1.5 mm thick CRCAsheet with angle iron work of min.of size (25x25x4) mm having front doors with viewing glass of size (200x150) mm and lockingarrangement with necessary fixing materialsuch as rubber bidding etc duly painted in post box red colour(Code 538 of IS 5)
518Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD
519Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF FAAS/MCP
520Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
521Supplying, installing, testingand commissioning FRLS, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU
522Supplying, installing, testing and commissioning of 28 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories, 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP ( As per Note No. 1 Increase overall rate by 25 % for additional zone as per requirement. )Original Rate for 2 Zone 17839.00 Add 25 % i.e.Rs.4459.75 for Additional Zone(26 Zone × 4459.75 = 115953.5) Hence Rate for 28 Zone is Rs.133792.50
523Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
524Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
525Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(0.3X0.6X200=36 CuM)
526Making cement concrete foundationin 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). (3X2X0.6=3.6 CuM)
527Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing for complete.(pole muffing or any other purpose)(0.3X0.3X0.3X30+ 0.3X0.3X200= 9.99+18=27.99CuM say 28 Cum )
528Providing Strecture cum passenger Lift to 100 Beded (Upgradation 50 to 100Beded) Rural Hospital at Mehkar Dist. Buldhana Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
529SITC of Electric Traction Passenger cum Stretcher/HospitalLiftwith Rated capacity :- 20 Passenger/1360Kg Floors :-G+3 floor (4Stops/4 Landings)Travel :- 3 to 11.00 mtrsLocation of Lift Machine:- MR/MRL Rated speed :- 1.0mps VS Car/Landing door clear opening of 1200 mm wide x 2000 mm highClear Carsize of1300 mm wide x 2400 mm deep x2250mm highLift shaft available having clear size of2400 mm wide x3000 mm deep, 1600 mm Pit depth, 4400 mm Overhead.Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory)Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing.CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers,erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc complete as per specification no LFT. General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.For Lift having 1200mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. For Full Collective control system, add as below. For Lift travellingabove First floor & up to Sixth floor(1934721+(155908X2)+27340)+5%=1934721+311816+27340+113693.85=2387570.85

AI Tender Summary

OUR REF NO 51542446
AUTHORITY Government Departments
TENDER VALUE 36.15 Crore
LAST DATE 14-10-2025
Authority
Authority Name Public Works Department
Work Description Tender For Upgradation Of 30 Bedded Rural Hospital To 100 Beded Sub District Hospital At Mehkar Dist. Buldana (With Electrification) (2Nd Call)
Basic Detail
Tender No E-TENDER NOTICE NO. 21/2025-26
Bidding Type Tender
Location
City mehkar
State Maharashtra
Key Dates
Publish Date 30 Sep 2025
Submission Date 14 Oct 2025
Open Date 16 Oct 2025
Finance
Tender Value 36.15 Crore
Tender Fee 5900
EMD 18.23 Lakhs
Exemption Not Available
Document List
c7cb4cbf-9f20-4f15-a3e7-070f13ea9ca9.html
01-21-B2.pdf
BOQ_2112378.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 16, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c7cb4cbf-9f20-4f15-a3e7-070f13ea9ca9.html

pdf

01-21-B2.pdf

xls

BOQ_2112378.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders