| 1 | Repair and Maintenance of Electrical Work in Angling Hut at Pong Dam, Distt. Kangra (HP) |
| 2 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-C |
| 3 | Supplying and fixing G.I. Modular box 3 Module with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections etc. as required. |
| 4 | Supplying and fixing G.I. Modular box ofsize 3 Module with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 5 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5 amp switch |
| 6 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus).5amp Socket |
| 7 | Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make:-Legrand(Myrius),L&T(entice),Anchor(Roma Plus). Bell Push Modular |
| 8 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x1.5 Sq. mm + 1X1.5 sq.mm |
| 9 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x4 Sq. mm + 1X4 sq.mm |
| 10 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 4x4 Sq. mm.+ 2X4 sq.mm |
| 11 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x10Sq. mm.+ 1X6 sq.mm |
| 12 | Providing, installationtesting and commissioning of ceiling fan with regulator including wiring the down rods of standard length (up to 30cm) and 16/0.20mm twin twisted flexiblecotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required including carriage of material within all leads and lifts. ( Usha technics,Crompten,Havells H S Velocity make or its equivalent. ) or as approved by the Engineer-in-Charge.1200 mm sweep |
| 13 | Providing and installation exhaust fan of300mm (Metal body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:Make:- Usha,Bajaj,Crompton or its equivalent as approved by Er-in-charge |
| 14 | Supplying and Fixing LED Battan 36 watt High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL22-511-XXX-65-G1 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent. |
| 15 | Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:- |
| 16 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- |
| 17 | Supplying and fixing 5 amps to 32 amps , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Hager,ABB or its equivalent as per best satisfaction of Engineer-in -charge. Single pole |
| 18 | Supplyinganderection of 40/50/63 amps, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Hager,ABBor its equivalent as approved by Engineer-in -charge. |
| 19 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar,interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator).Make L&T ,Legrand, Hager or its equivalent as approved by Engineer-In-Charge MCBDB 16 WAY |
| 20 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18\" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required. b) 25 liter capcity water heater (Cat-A) |
| 21 | Supplying and fixing copper strip bus-bars and Bus bar Boxsuitable for 100 Amp. 415 volts capacity4 No. each ofcross-sectional area (25.4mmx3.17Mm),in the existing enclosure with all accessories including connections etc. as required:-.Make:-L&T ,Legrand,Haggeras approved by Engineer-in -charge. |
| 22 | Supplying and fixing 1.5ton invertor split type air conditioner Cold with vloltage stablizer 140V to 2900 V(V-Guard OR Microtek Make ) , advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supplycapable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacityand drain pipe20 mm dia approximately3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and M.S power coated frame /stand for erection of out door unit of split type A.,C including carrigae of material with in all leads and lift. Make -LG(model:TS-Q19YNZE1), OR Samsung (model : AR18CYNZABE) 5 Star , as approved by the Engineer Charge |