| 1 | Supply of the materials mentioned below to the proposed work site or JE store. |
| 2 | TRANSFORMER 11/0.4 KV, 400 KVA |
| 3 | S.T POLE 11 MTR LONG |
| 4 | 11 KV AL XLPE (3X120) SQMM |
| 5 | 11 KV 3X120 SQMM CABLE JOINTING KIT O/D |
| 6 | 11 KV 3X120 SQMM CABLE JOINTING KIT I/D |
| 7 | 11 KV 3X120 SQMMCABLE JOINT KIT S/Th |
| 8 | LT XLPE CABLE 3.5X400 SQMM |
| 9 | 11 KV PIN INSULATOR |
| 10 | 11 KV AL WEASEL CONDUCTOR |
| 11 | LT ABC (3X120 + 1X95 + 1X16) |
| 12 | OUTDOOR CT/PT METERING UNIT (25/5) |
| 13 | 11 KV PHILPHER |
| 14 | The works mentioned below must be carried out according to RESPPO regulations. |
| 15 | O&M OF ABOVE 11/.4KV, RMU, 11/0.4 KV 400KVA SUBSTATION DURING SCOUT GUIDE PROGRAM ROUND OF CLOCK FROM THE DATE OF ENERGISATION (TOTAL 07 DAY) WITH THE HELP OF 01 SKILLED AND 02 NOS UNSKILLED OPERATING STAFF (OPERATING STAFF WILL BE PROVIDED BY THE CONTRACTOR ). 01 NO. SKILLED AND 02 NO. UNSKILLED( IN EACH JOB)MANPOWERMUST BE EACH SHIFT AND MINIMUM 3 SHIFTS MUST BE PERFORMED EVERY DAY. |
| 16 | CARREGE MOBILE TRANSFORMER TROLLY FROM JE STORE TO SITEAND SITE TO JE STORE SUITABLE FOR UPTO 630/400/250 KVA WITHCOMPLETE INSTALLATION And Errection of LT Distribution Box With Tailness Fuse Unit Against Trolley (6 NOS Circuit 500 AMP Cu Busbar Size 1000X50X6MM.) With Metering Equipments. (Note: Additional JOB May Be needed as per requirenment (Upto+5Nos) |
| 17 | Dragging of ST Pole digging of pit erection of sub-station type double pole structure on ST Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 11 pin insulator with Pin & 11 KV Disc Insulator with fitting, DO Fuse set its ramming, as per RESPO Specification (All Materials will be Provided by the Contractor). |
| 18 | Construction of Foundation fot LT Tailness Fuse Unit, As per RESPO Specification (All material and labour shall be supplied the contractor). |
| 19 | Maintenance of Existing RMU 3-Way/ 4-Way, As per RESPO Specification. (Also Provide 01 Nos. Experienced RMU Operator (with RMU Space Parts) From (23-11-2025 to 30-11-2025) |
| 20 | Construction of T/F plinth of size 2x2x1.5 mtr with the help first class brick & masonry in the ratio 1:4 cement & sand coarse. Filling the structure completely per norms with RCC to 1:2:2 cement & stone grit with MS bar and MS channel for resting transformer. (All material and labour shall be supplied the contractor). |
| 21 | Cable Hosting of 11 KV 3x120 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as PerRESPO Norms. (GI pipe and other required material 3X120 SQMM CABLE , F, shall be supplied by the contractor). |
| 22 | Earthing of poles as per RESPO norms (All the Materials Supplied by the contractor). |
| 23 | Boring type earthing for TF (Neutral & Body) of with 60 Fit Deep boring and providing GI Pipe 1.5\" dia (\"B\" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap.as per RESPO norms (All material and labour shall be supplied the contractor) |
| 24 | Chemical type earthing for Trolly T/F(All the Materials Supplied the contractor) |
| 25 | Wire mess fencing of 11/0.4 KV S/S, RMU, CT-PT METERING UNIT, MAIN LT DISTRIBUTION PANNEL (10x5x2 MTR) shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I (All material will be provided by the contractor). |
| 26 | 11 KV HIGH PRESSURE TESTING |
| 27 | Laying of3X120 sq.mm 11 KV XLPEcable double Circuit by drill method as per RESPO Norms. (All material EXECPT 11 KV 3X120 SQMM XLPY CABI, F, will be provided by the Contractor). |
| 28 | Laying of3.5x400 sq.mmcable double Circuit by Manually method as per RESPO Norms. (All material EXCEPT LT 3.5X400 SQMM. CABLE will be provided by the Contractor). |
| 29 | Proper laying & commissioning of(LT ABB (3x1201X95,1X16Aerial Bunched Conductor. (Only ABC Cable will be Provided by the department). |
| 30 | Road Restoration charges for footpath side. |
| 31 | Supply and Fixing LT DISTRIBUTION BOX WITHTAILLESS FUSE UNIT SIX CIRCUIT 500AMP CU BUSBAR SIZE 1000X50X6MM. (All Material with earthing will be provided by the contractor) |
| 32 | OLD STRUCTURE DISMENTAL CHARGES & CARRAGE FROM SITE TO CENTRAL STORE/JE STORE (4 NOS. T/F) |
| 33 | Supply and fixing of Danger board with Clamp as per RESPO Norms (All material will be provided by the Contractor). |
| 34 | Fabrication, errection & commissioning of 400KVAT/F on Plinth with all accessories. (All material except 400 KVA T/F shall be supplied by the Contractor). |
| 35 | Fixing OUTDOOR / INDOOR END TERMINATION JOINTING KIT FOR 11 KV 3X120 SQMM XLPE CABLE. (ONLY JOINTING KIT AND STRAIGHT THROUGH will be provided by the Department). |
| 36 | POLE PAINTING WORK WITH LABOUR & MATERIEAL. |
| 37 | ERRECTTION OF PHIPHERWITH CHEMICAL EARTHING (1 NOS PHIPHER shall be supplied by the Department and all other). |
| 38 | ERRCTTION OF 04 NOS OUTDOOR CT/PT UNIT ON DOUBLE POLE(All Material except 04 nos. Outdoor CT/PT UNIT OF DOUBLE POLE,shall be supplied by the Contractor). |
| 39 | Fixing and laying of weasel conductor (Only conductor will be Provided by the department.) |
| 40 | Grouting of ST Pole (All Material with earthing will be provided by the contractor) |
| 41 | G.S.T. EXTRA AS PER RULES. |
| 42 | IMPORTANT INSTRUCTION / NOTICE- On completion of the work, close view updated photographs of the said work along with GEO Tag must be made available. |