| 1 | Surface dressing n. exc 15cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L forHardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for cement concrete 1:3:6, 100mm thick type C-2 using 40mm graded stone aggregate over rammed earth as in sub base to receive floor finish etc complete all as specified and directed by Engr-in-Charge. |
| 4 | Providing and laying 80mm thick factory made chamfered edge cement concretepaver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges type B1 1:2:4 (using 20mm graded aggregate) complete all as specified and directed by Engr-in-Charge. |
| 6 | Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge. |
| 7 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 8 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.Note: Only punned thickness shall be measured and paid. |
| 11 | S&F Aluminium Cable Terminal Lug size of 150 to 185 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 12 | S&FAluminium Cable Terminal Lug size of 95 to 120 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F Aluminium Cable Terminal Lug size of 50 to 70 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F Aluminium Cable Terminal Lug size of 16 to 35 Sqmm,complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F copper Cable Terminal Lug size of 6 to 10 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. |
| 17 | Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 sqmm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Make : Havells/Polycab/Plaza/Paramount or equivalentNote : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items. |
| 19 | Description all as Srl item No. 18.00 here in before but for cable size of 50 sqmm 3.5 core. |
| 20 | Description all as Srl item No. 18.00 here in before but for cable size of 35 sqmm 3.5 core. |
| 21 | Description all as Srl item No. 18.00 here in before but for cable size of 25 sqmm 4 core. |
| 22 | Description all as Srl item No. 18.00 here in before but for cable size of 16 sqmm 2 core. |
| 23 | Description all as Srl item No. 18.00 here in before but for cable size of 10 sqmm 2 core. |
| 24 | Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge. |
| 25 | Supply, install, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT Panel size 1.8m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply, Aluminium bus bar of capacity 500 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four complete all as specified and directed by Engr -in-Charge and comprising of following accessories/fittings :-(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,36 KAwith adjusstable type = 01 Nos (I/C)(b) MCCB 4 pole, 63 Amps, 415 Volt, AC,25 KA= 02 Nos (O/G) |
| 26 | (c) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (d) ON Load Change over Switch 250 Amps 4 Pole adjustable type -01 No(e) Volt meter 0-500 Volt meter digital type with selector switch.(f) Ammeter 0 to 400 Amp with selector switch & suitable range of CTs = 01 No(g) Phase indicator lamp LED Type -1 set |
| 27 | Supply, installation, testing and commissioning, in replacement,Junction box, cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick,complete with openable shutters in front and rear having proper locking arrangement includingincluding 04 Nos legs made out of angle iron of suitable size and height of each leg shall begrouted in PCC andaluminium busbar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge. |
| 28 | M&L Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Repair to old UNSV LT Panel comprising cleaning, servicing, tightening of connections, replacement of unserviceable/damaged components such as MCCBs, MCBs, contactors, relays, indicators, selector switches, wiring and allied accessories, attending defects in busbars, terminations, earthing arrangements, repainting/anti-corrosive treatment of panel body, testing and relocated were directed incl PCC foundation etc complete all as specified and directed.”Note- Material such as MCCBs, MCBs, contactors, relays, indicators, selector switches are provided by the department. |