| 1 | M&L for dismantling cross-arms of M.S channel or angle sections etc. complete all as specified and directed. |
| 2 | M&L for dismantling old insulator complete all as specified and directed. |
| 3 | M&L for dismantling of old un-serviceable ACSR conductor of any size and make from LT over head line complete all as specified and directed. |
| 4 | M&L for dismantling stay assembly complete.(demolition of concrete, etc. and excavationmeasured separately) complete all as specified and directed. |
| 5 | M&L for excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depthfor foundation of pole,laying of cables etc in Hard and dense soiland getting out complete all as specified and directed. |
| 6 | M&L for returning fillingin including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. |
| 7 | M&L for removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid complete all as specified and directed. |
| 9 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in foundtion of pole/stay/PCC of road cutting assembly etc including necessary form work, all as specified and directed. |
| 11 | Supply and laying sub classold \"B\" burnt bricks laid as cable protection covercomplete all as specified and directed. |
| 12 | Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm(internal)comprising of suitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt, nut including 01 x MCB SP 6 Amps and connecting up cables with aluminium terminal lugs all as specified and as directed. |
| 13 | Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 14 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 15 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 16 | Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 17 | Supplying & laying, XLPE insulated PVC inner sheathed, 25 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 18 | Supplying & laying, XLPE insulated PVC inner sheathed, 50 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 19 | Supplying & laying, XLPE insulated PVC inner sheathed, 95 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 20 | S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 35 mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo oldcomplete all as specified and directed. |
| 21 | M&L Painting to steel tubular poles LT of 8.5/9Mtr long incl fittings and fixtures complete, fixed with poles with one coat of alluminium paint incl scrapping of rusts and preparation of surfaces andwriting letters and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles.etc., complete all as specified and as directed by Engr-in-Charge. |
| 22 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete all as specified and directed. |
| 23 | Supply, installation, commissoning and testing, in repair, feeder pillar board,Kiosktype, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) plinth mounted, factory made, compartment type,outdoor type,weather and vermin proof (Protection Class IP-54) made out of 50m x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enemell gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron 0.45 mtr in ground and 0.3 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 300 amps rating of 04 strip - 01 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 160 Amp rating, 35 KA rupturing capacity - 01 No (iii) Digital type voltmenter 0-500 V with selector switches - 01No (iv) Digital type Amp meter 0-300A with selecter switch with CT ratio 400/5A- 01 No (v) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b)Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 100 Amp rating, 25 KA rupturing capacity - 03 No No. (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 63 Amp rating, 16 KA rupturing capacity - 03 No. |
| 24 | Supply, installation, commissioning and testing, feeder piller board,compartmenttype , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type,weather and vermin proof made out of angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.30 mtr over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar 100 amps rating of 04 strip having suitable whole with nuts and bolts (ii) MCCB 63 Amps, 04 pole415 Volt-01 No, (iii) MCCB 40 Amp, 04 pole, 415 Volts-04 Nos (iV) MCB 40 Amp, 02 pole, 230 Volts-04 Nos(v) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (vi) Indicating lamp Neon type for R-Y-B - 3 Nos. |
| 25 | M&L,earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 32X6mm as earth lead all as specified and testing on completion includingprovisionof earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete all as specified and directed. |
| 26 | S&F, in repair, FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth PVC pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. including taking down old complete all as specified and directed. |
| 27 | S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along thepoles / walls with necessary clamping,including taking down oldetc complete all as per specified and directed. |
| 28 | S&F, in repair, GI pipe, 50mm bore, light grade, laid below road/fixed along thepoles / walls with necessary clamping,,including taking down oldetc complete all as per specified and directed. |