| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depthfor foundation of pole,laying of cables etc in Hard and dense soiland getting out complete all as specified and directed. |
| 2 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out complete all as specified and directed. |
| 3 | Returning fillingin including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. |
| 4 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts all as specified and directed. |
| 7 | M&L for plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed. |
| 8 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed. |
| 9 | Supply and laying sub classold \"B\" burnt bricks laid as cable protection covercomplete all as specified and directed. |
| 10 | Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed. |
| 11 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 finished surfaces fair and even complete all as specified and directed. |
| 12 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces (external surface) on wall in CM 1:4 finished surfaces fair and even complete all as specified and directed. |
| 13 | M&L for preparationof new plastered surfaces of wall and applyingtwo coats of cement base paint complete all as specified and directed. |
| 14 | M&L for preparation of old plastered surfaces of wall and applyingone coat of cement base paint complete all as specified and directed. |
| 15 | M&L for preparation of old decorated plastered or unplastered surfacesof wall by complete removal of existing treatment, moulds, moss and efflorescent salts and trading oil and greasy spots and applying three coat of white wash including cornices etc complete all as specified and directed. |
| 16 | M&L for preparation old previously treated surface of wood and wood based surfaces, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 17 | M&L, preparing of new steel surfaceexceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 18 | M&L for preparation of old painted steel surfaces of any descriptionnot otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 19 | M&L for mild steelframed work such as grills, gratings, etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars in gates etc andsimilar work conforming toFe-290 (Gde-E-165) complete all as specified and directed |
| 20 | Dismantling Asbestos cement (Corrugated semicorrugated ,etc) sheets in roof coverings complete all as specified and directed. |
| 21 | M & L, Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length complete all as specified and directed. |
| 22 | M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 23 | S&F rolled mild steel section as in main and cross beams hip and jack rafters , purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed. |
| 24 | Fixing only rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed. |
| 25 | Demolition of cement concret of any description and in any position not otherwise specifically provided forcomplete all as specified and directed. |
| 26 | Demolition of precast concrete articles and pre cast cement concrete block walling, ashlar fencings, dressed stone work including all quoins, arches, pillars, etc built in cement mortar complete all as specified and directed. |
| 27 | M&L for Pre-cast cement concrete block masonry type C1 1:3: 6 (20mm graded aggregate)with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 28 | S&F for Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed. |
| 29 | S&F in repair sheet glass 3.00 mm thick ordinary qualityand glazing with oil putty in squaren exc 0.5 sqm in each pane complete all as specified and directed. |
| 30 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 31 | Taking down carefully copper/Aluminium point wiring (light, fan, socket or power) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etcall as specified and directed by Engr-in-charge. |
| 32 | M&L for point wiring for one light/Fan point controlled by one switch one way in & including concealed PVC conduit using FRLS PVC sheathed multistrand copper conductor wire 1.5 sqmm single core for one light/fan point controlled by one switch including 3 mm thick plastic laminated sheet cover over concealed MS sunken box for earth continuity insulated PVC sheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge.Note : (a) wiring shall be done by using proper colour coding. (b)Being MT shed point wiring to be measured from switch board to light point only. |
| 33 | All as per srl item No. 32 here-in-before but for 3 pin 5 Ampsocket outlet on independent board. |
| 34 | All as per srl item No. 32 here-in-before but for 3 pin 5 Ampsocket outlet on same board. |
| 35 | All as per srl item No. 32 here-in-before but for 15/16 Ampindependent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified. |
| 36 | S&F ceiling rose 3 terminal size 50 x 65mm surface type 230 volts complete all as specified and directed. |
| 37 | S&F Switch piano, flush type 5 Ampsone way 230 volts complete all as specified and directed. |
| 38 | S&F Socket outlet3 pin 5 Ampsflush type 230 volts complete all as specified and directed. |
| 39 | S&F,Switch piano, flush button, single pole, one way 5/15 Amps complete all as specified and directed. |
| 40 | S&F,Socket outlet, 2 in 1, 3 pin, 5/15 Amps flush type complete all as specified and directed. |
| 41 | S&F, sub-main wiring with 3 single core (for phase, neutral & earth), 2.5 Sqmm PVC insulated, sheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC conduit concealed of 20/25mm size and earth wire drawn should be connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i)3 runs of main conductor and one run of PVC conduit concealed shall be measured as one unit length.(ii)Being MT shed sub main wiring to be measured from DB to switch board only. |
| 42 | Taking down carefully old unserviceable main switches/ DBs any type including fuses MCB etc after removing all connection, wires and making good the disturb surface complete allas directed by Engr-in-charge. |
| 43 | S&F 45W New generation energy saving and environmental friendly long life LED flood light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 for flood light with GI pipe bracket or clamp with nut bolt of suitable size for fitting complete all as specified and directed by Engr-in-charge. |
| 44 | S&F Sheet metal enclosure double door for DB\"s SPN 12 way 230 V having200 A rated bus bar complete all as specified and directed by Engr-in-charge. |
| 45 | S&F MCB SPN 32A, 230 V -10 KA all as specified and as directed by Engineer-in-charge. |
| 46 | S&F MCB SP 6-32A, 230 V -10 KA all as specified and as directed by Engineer-in-charge. |
| 47 | Dismantling cross-arms of M.S channel or angle sections etc. complete all as specified and directed. |
| 48 | Taking out the existing U/S light fittings carefully with removing electric connection and safe custody of contractor and conditions light fittings to be schedule of creditall as specified and directed by the Engr-in- charge |
| 49 | Taking out the existing RCC pole carefully with removing electric connection including earth work and dismantling of PCC pole all as specified and directed by the Engr-in- charge |
| 50 | Dismantling old insulator complete all as specified and directed. |
| 51 | Dismantling stay assembly complete all as specified and directed.(demolition of concrete, etc. and excavationmeasured separately) complete all as specified and directed. |
| 52 | Dismantling of old un-serviceable ACSR conductor of any size and make from LT over head line complete all as specified and directed. |
| 53 | Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) including numbering of poles with aluminium paint and painting up to 1.5 meter above PCC benching of poles in black and white strips 3 number complete all as specified and as directed by Engr-in-Charge.(Excavation, earth work, foundation concrete and coping etc will be measured and paid separately). |
| 54 | Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm(internal)comprising of suitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut, MCB SP 6 Amps and connecting up cables with aluminium terminal lugs all as specified and as directed. |
| 55 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete |
| 56 | Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 57 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 58 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 59 | Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 60 | Supplying & laying, XLPE insulated PVC inner sheathed, 25 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 61 | Supplying & laying, XLPE insulated PVC inner sheathed, 35 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 62 | Supplying & laying, XLPE insulated PVC inner sheathed, 50 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 63 | Supplying & laying, XLPE insulated PVC inner sheathed, 95 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 64 | S&F FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. including taking down old |
| 65 | S&F bracket made out of light grade, Galvanised steel tube, 35 mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo oldcomplete all as specified and directed. |
| 66 | S&F, in repair, GI pipe, 50mm bore, light grade, laid below road/fixed along thepoles / walls with necessary clamping,,including taking down oldetc complete all as per specified and directed. |
| 67 | S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along thepoles / walls with necessary clamping,including taking down oldetc complete all as per specified and directed. |
| 68 | M&L for cutting of road for laying of LT cable and making good to match with the existing using extra cement etc. complete all as specified and as directed. |
| 69 | Supply, installation, commissoning and testing, in repair, feeder pillar board,Kiosktype, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) plinth mounted, factory made, compartment type,outdoor type,weather and vermin proof (Protection Class IP-54) made out of 50m x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enemell gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron 0.45 mtr in ground and 0.3 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 400 amps rating of 04 strip - 01 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 250 Amp rating, 35 KA rupturing capacity - 01 No (iii) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b)Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole AC 415volts, 200 Amp rating, 35 KA rupturing capacity - 02 No. (iii) MCCB, thermal and meganitic setting, 3 pole AC 415volts, 160 Amp rating, 25 KA rupturing capacity - 03 No. (iV) MCCB, thermal and meganitic setting, 3 pole AC 415volts, 100 Amp rating, 16 KA rupturing capacity - 02 No. (iv)Time switch, single phase, 230 volts with 24 hours time setting, current rating 16 Amps and with AC relay type ML-3 and with MCB TPN,C curve 32 Amp, three phase including internal connections - 02 Nos. (v) MCB SPN, C-curve, 63 Amps, AC 230 Volt - 03 No including internalconnections. |
| 70 | Supply, installation, commissoning and testing, in repair, feeder pillar board,Kiosktype, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) plinth mounted, factory made, compartment type,outdoor type,weather and vermin proof (Protection Class IP-54) made out of 50m x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enemell gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron 0.45 mtr in ground and 0.3 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 250 amps rating of 04 strip - 01 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 160 Amp rating, 25 KA rupturing capacity - 01 No (iii) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos(b)Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole AC 415volts, 125 Amp rating, 25 KA rupturing capacity - 02 No. (iii) MCCB, thermal and meganitic setting, 3 pole AC 415volts, 100 Amp rating, 25 KA rupturing capacity - 02 No. (v) MCB SPN, C-curve 40 Amps, AC 230 Volt - 03 No including internalconnections |
| 71 | Supply, installation, commissioning and testing, feeder piller board,Kiosktype , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type,weather and vermin proof made out of angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.30 mtr over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Incoming supply :- (i) Aluminium bus bar 200 amps rating of 04 strip having suitable whole with nuts and bolts (ii) MCCB 100 Amps, 25 KA, 04 pole415 Volt-01 No.(b) Outgoing (i) MCCB 63 Amp, 03 pole, 415 Volts - 04 Nos (ii) MCB 40 Amp, 02 pole, 230 Volts-04 Nos (iii) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (iv) Indicating lamp Neon type for R-Y-B - 3 Nos. |
| 72 | M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth Lead 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth wire of 4mm as earth lead all as specified and testing on completion includingprovisionof earth lead protected by 20 mm dia light grade GI pipe & watering pipe shall be 15 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 73 | M&L,earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 32X6mm as earth lead all as specified and testing on completion includingprovisionof earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. |