}

Tender For Misc Repair And Maintenance Including Connected Items At Water Supply Installations Under Age E/M (Ws) Of Ge (U) Meerut Cantt., meerut-Uttar Pradesh

Tender Notice

51535037
Tender For Misc Repair And Maintenance Including Connected Items At Water Supply Installations Under Age E/M (Ws) Of Ge (U) Meerut Cantt.
Tender
Indian
Uttar Pradesh
Meerut
21-10-2025

Tender Details

Misc Repair And Maintenance Including Connected Items At Water Supply Installations Under Age E/M (Ws) Of Ge (U) Meerut Cantt.; 1 M & L getting out clearly all grass vegetation, saplings, shrubs, bush, wood, undergrown roots, and trees not exceeding 30 cm girth and removing rubbish outside the periphery of the PH area under clearance including surface dressing all as directed by Engr -in-charge 2 M & L for pruning of trees and cutting of newborn trees/bushes (any height) located inside pump house premises/on the roof of pump house complete all as specified and directed by Engr-in-charge. 3 Cleaning of valve pit chambers inside Pump Houses including removal of mud, dust, debris, stagnant water etc all as directed by Engr-in-charge 4 M & L painting of motor body of any size and capacity using synthetic enamel paint with one coat as directed by Engr-in-charge including preparation of old surfaces all as directed 5 M & L painting iron surfaces of pipes, NRV & sluice valves connected to motor running toward OHT of size 4/6/8 dia from pump using synthetic enamel black paint with one coat including preparation of old surface before application of paint all as directed by Engr-in-charge 6 Supplying and laying synthetic Rubber insulated mats2.5 mm thick for voltage upto 11 kv for electrical purposeas per IS 15652-2006, (superseding IS 5424) suitable forelectrical shock safety of sizes 2m x 1m all as directed by Engr-in-charge 7 Testing of water sample , chemical, biological and physical including hardness, turbidity, E-coli, coliform all as directed by Engr-in-charge from a NABL accredited lab Note:- Contactor shall arrange for collection of sample as and when directed from pump houses / any other source & including provn of clean glass container properly sealed and send the same to the lab with - in 04 hrs of collection. 8 Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed. 9 Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed. 10 Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed 11 Disconnecting and taking up old existing CI/GI water pipe and connection / grade and in any position of trenches / under floors/ on walls etc including connected fitting/ accessories and fixtures such as bend, Tee, Valve etc, all as directed and specified for the followingsizes :- 12 150mm dia 13 100mm dia 14 Disconnecting and taking up old existing GI water tubing and connection / grade and in any position of trenches / under floors/ on walls etc including connected fitting/ accessories and fixtures such as bend, Tee, Union,Valve etc, all as directed and specified for the followingsizes :- 15 50mm dia 16 40mm dia 17 25mm dia 18 20mm dia 19 15mm dia 20 Supply & laying in trenches DI pipe with spigot and socket class K-07 size 150mm bore suitable for tyton joints in S-5.5 mtr length 21 Supply & laying in trenches DI pipe with spigot and socket class K-07 size 100mm bore suitable for tyton joints in S-5.5 mtr length 22 M & L DI/CISpecials class B as per ISsuch as bends,tappers,any type branches cross all sockets and spigot collar caps, Tee, flanged and plug etc. up to 250mm bore all as specified and as directed 23 S & FGI Tubes, Medium grade,galvanised,with all fitting;laid in trenches complete all as specified & directed, for the following size:- 24 50mm dia bore 25 40mm diabore 26 25mm dia bore 27 S & F GI Tubes, mediumgradegalvanised, withall fitting andfixed completeto walls andceilings or laidin floors complete all as specified & directed, for the following size:- 28 20mm diabore 29 15 mm dia bore 30 M&L to Supply, installation, testing of Sluice valves flanged of class 1.6 PN with stainless steel spindle, nuts, bolts washer etc including taking out old UNSV sluice valve complete all as specified and as directed as per following sizes: 31 150mm diabore 32 100mm diabore 33 S&F Gun metal, glove orgate valves with iron wheel head, screwed both ends for GI pipe 50mm dia including taking out old unsv complete all as specified and directted. 34 S&F Gun metal, glove orgate valves with iron wheel head, screwed both ends for GI pipe 40mm dia including taking out old unsv complete all as specified and directted. 35 S&F Gun metal, glove orgate valves with iron wheel head, screwed both ends for GI pipe 25mm dia including taking out old unsv complete all as specified and directted. 36 S&F Gun metal, glove orgate valves with iron wheel head, screwed both ends for GI pipe 20mm dia including taking out old unsv complete all as specified and directted. 37 S&F Gun metal, glove orgate valves with iron wheel head, screwed both ends for GI pipe 15mm dia including taking out old unsv complete all as specified and directted. 38 M&L for directional boringfor 180mmdia and up to 1.5m depth with hydraulic machine under any surface ( Hard/Deuse/ RCC/ Coal tar Road) for laying of pipeline including trenching if required . Cost of horizontal Bore Machine (hydraulic) & all allied itemes requiredfor boring is deemed to be included in qnoted Rates 39 M&L for Cutting of CI/DI Pipes and reducingto required length before laying in position for insertion of new tees, branches etc complete all as specified & directed. For following size :- Note :- Fittings will be measured and paid for separately under respective item. 40 150mm diabore 41 100mm diabore 42 Labour charges for repair/replacement of Old UNSV CI/DI pipe line outside/inside of OHT work for riser / delivery lines of any size at any height including preparation of staging and necessary tools required. Repair work includes replacement of D joint/flange/socket using required fitting on ground during execution all as specified and directed by Engr-in-Charge Note:- Rate of fittings required is deemed to be included in the Job. 43 M & Lcement concrete type B-11:2:4 (20mm grade stone aggregate) as in door cills, path and plinth protection (of any section)including chambers, weatherings, throat-ing etc and setting in mortar complete all as specified and directed. 44 M&L for iron work as in angle/clamps/channel for branch connection of water supply, made to shape of flat iron of suitable size incl nuts, bolts, washers of appropriate size and painting with synthetic enamel paint in two coats over one coat of redoxide zinc chrome primer complete all as specified. Note:- Cost of fixing clamps/angle iron/frame in walls by cutting and grouting in PCC is deemed to include in the rate quoted by tenderer. 45 Supply & fix in repair galvanized item fitting like TEE, Elbow, Socket, Union, Reduser, Nipple of suitable size for existing GI tubing of size up to 100mm for preventing leakage if any of make new branch connection complete all as specified and directed. 46 Supply and fixing in repair Bib taps 15 mm dia, PTMT any colour, high pressure screwed for iron pipes and fixed to pipe (minimum weight not less than 90 gms) fixed in repair complete all as specified& directed. 47 S & F in repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 200 mm nominal bore CI/DI pipe complete all as specified. 48 S & Fin repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 150 mm nominal bore CI/DI pipe complete all as specified. 49 S & Fin repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for100 mm nominal bore CI/DI pipe complete all as specified. 50 S & Fin repairlong length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 80 mm nominal bore CI/DI pipe complete all as specified. 51 S & Fin repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 50 mm nominal bore CI/DI pipe complete all as specified. 52 S&F in repairs cast iron non return valve, both ends flanged jointed, ISI marked, of approved qualityand tested complete all as specified and directed of following sizes :-. 53 200mm dia bore 54 150mm diabore 55 100mm diabore 56 Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for taking credit and making good disturbed surfaces of walls, floors etc. 57 M&Lfor point wiring inPVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. 58 One light point/fan point/Exhaust fan point controlled by one 5 Amps switch one way 59 One 3 pin 5 Amp switch socket outlet on independent board 60 One 3 pin 5 Amp switch socket outlet on same board with accessories 61 M&Lfor point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. 62 S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. 63 S&FSocket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. 64 S&F Switch socket combination 2 in1, 3 pin, 6 and 16 Amp flush type,universsal complete all as specified and as directed. 65 S&F Switch socket combination 2 in1, 3 pin,6 Amps flush type with box ,universsal complete all as specified and as directed. 66 S&F stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified. 67 Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body. 68 S&FLamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. 69 Supply and fix LED inverter bulb 12W. 70 S & F in repair decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, 1x22 W, 230 Volt aluminium LED lighting fixture with high lumen output, environmental friendly,complete all as specified and directed. 71 Supply and fix in repair exhaust fan, plastic body AC single Phase copper winding, 230V 50Hz of size 150mmsweep with, blades, and frame andlouver including taking out old unsv and depositing in MES store complete all as specified and directed. 72 S&F in repairs Double door metallic sheet metal enclosure for DB MCBs SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. 73 S&F in repairs Double door metallic sheet metal enclosure for DB MCBs SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. 74 S & F in repairs MCB, SPN 32 Amps 240 VoltsC curve, complete all as specified and as directed. 75 S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed. 76 M & L sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm diaPVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM 77 S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tapeand overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 6 sqmm including taking taking out old unsv complete all as specified and directed 78 S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tapeand overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmmincluding taking taking out old unsv complete all as specified and directed 79 Supply and fix BLDC ceilingfan 1200mm sweep, AC single Phase copper winding, 230V, 50Hz including taking out old unsv and depositing in MES store complete all as specified and directed. 80 M&L for disconnecting of chloronome plant from main raising line including all INPUT/OUTPUT water supply pipes and electric connections from LT panel to repair/replace of following old UNSV parts:- 81 M & L in repair of NRV made of brass as existing suitable size complete all as specified and directed by Engr-in-charge. 82 M & L in repair of union as per existing suitable size complete all as specified and directed by Engr-in-charge. 83 M & L in repair of elbow as per existing suitable size complete all as specified and directed by Engr-in-charge. 84 M & L in repair of ball valveof CPVC as per existing suitable size complete all as specified and directed Engr-in-charge. 85 M & L in repair of connector as per existing suitable size complete all as specified and directed by Engr-in-charge. 86 M & L in repair of SS aegitator complete with rotator fan and all connectedaccessories as per existing suitable size complete all as specified and directed by Engr-in-charge. 87 M & L in repair of MTA as per existing suitable size complete all as specified and directed by Engr-in-charge. 88 M & L in repair of FTA as per existing suitable size complete all as specified and directed Engr-in-charge. 89 M & L in repairof motor bush after opening of complete motor nut and bolts as per existing/suitable size complete all as specified and directed Engr-in-charge. 90 M & L in repairof chlorine injector pump as per existing/suitable size complete all as specified and directed Engr-in-charge. 91 M & L in repair of star coupling as per existing suitable size complete all as specified and directed by Engr-in-charge. 92 M & L in repair of CPVC pipes of high grade as per existing suitable size complete all as specified and directed by Engr-in-charge. 93 M & L in repair of FRP tank of dozer as per existing/suitable size and capacity complete all as specified and directed by Engr-in-charge. 94 M & L in repair of UNSV DOL starter three phase suitable for 220 V, 50 Hz,motor upto 2 to 3 HP capacity complete all as specified and directed by Engr-in-charge. Make L&T , Havells /Shalabh India Ltd 95 M & L in repairof UNSV 3 phase electric motor as per existing make & capacity suitable for 220 V, 50 Hz,complete all as specified and directed by Engr-in-charge. 96 S & F in repairs MCB, TPN 16 Amps 240 VoltsC curve, complete all as specified and as directed by Engr-in-charge. 97 S & F in repairs diaphram of chloronome pump as per existing make and model complete all as specified and as directed by Engr-in-charge. 98 M&L for assembling of chloronome plant including all INPUT/OUTPUT water supply connections and electric connections, to make functional complete all as specified and directed by Engr-in-charge.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail