| 1 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth oftrenches for laying of pipe lines and getting out including forming bottom surfaces to required level in soft/loose soil complete all as specified anddirected |
| 2 | All as per Sl item No 1 above but depth exc 1.5 mtr and n.exc 3.0 mtr. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed. |
| 4 | Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed. |
| 5 | M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed. |
| 6 | M&L for brick protection cover of UG cable by using old size sub class \"B\"\" common burnt clay building bricks,laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed. |
| 7 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core complete all as specified and directed. |
| 8 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core all as specified and directed. |
| 9 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core all as specified and directed. |
| 10 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 2 core core all as specified and directed. |
| 11 | S & F XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,cross sectional area 25 sqmm 4 core all as specified and directed by Engr-in-Charge. |
| 12 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3½ core core all as specified and directed. |
| 13 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3½ core core all as specified and directed. |
| 14 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3½ core core all as specified and directed. |
| 15 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3½ core core all as specified and directed. |
| 16 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm 3½ core core all as specified and directed. |
| 17 | S&F GI Pipe 80 mm dia light gradefor protection of cable complete all as specified and directed.. |
| 18 | S&F GI Pipe 40 mm dia light gradefor protection of cable complete all as specified and directed. |
| 19 | M&L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation of pole/stay/strut, filling and massconcrete etc complete all as specified and directed. |
| 20 | M&L for cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in cills, copings, pole pedestals, plinth courses and the like including necessary form work,weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 21 | Dismantling of LT steel tubularpole of any size and description incl coping, foundation etc and shifting to E/M yard or any other locationcomplete all as specified and directed.. |
| 22 | M&L for erecting the LT pole dismantled under above, in perfect vertical position, embedded in PCC foundation (1:4:8) type D-2 and coping PCC (1:3:6) type C-2 complete all as specified and directed. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately. |
| 23 | Supply, installing steel tubular swaged poles type 410-SP-31 (9 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position complete including dismantling of US existing pole by breaking PCC coping and making good as existing ground from site complete as directed by Engr-in-Charge. Note :- (a) Earth work and PCC in foundation / coping/pedestal shall be measured and paid for separately under respective items.(b) Poles shall be painted with two coats of black bituminous paint throughout internally, and externally upto planting depth.The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer. |
| 24 | Disconnecting and taking out LT OH line conductor with GI earth wire of any size fixed on existing cross arms by loosing the binding wire from the insulator where ever necessary and refixing /restraining, securing, tightening the OH lines in each span n.exc 35 m (average) for three phase and neutral with street light feeder and GI guard wire all as directed by the Engr-in-Charge. |
| 25 | All as per Sl item No. 24 above but for three phase and neutral with GI guard wire. |
| 26 | All as per Sl item No. 24 above but for one phase and neutral with GI guard wire. |
| 27 | S&F galvanized steel stay assembly complete with stay rod 20mm dia including stay wire 7/3.15 mm fixed for stay of poles including necessary MS clamp of flat iron 50x6mm, nuts & bolts etc completeincluding dismantling of stay assembly from site and making good as per existingcomplete all as specified and directed.Note:- Earth work & PCC in foundation / coping shall be measured and paid for separately under respective items. |
| 28 | M& L for Cleaning and preparation ofLT steel tubular pole complete and painting with one coat of aluminium paint including channels/ brackets , cross arms and making red & white strips with synthetic enameled paint of 30 cm height, eachalternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enameled paint after making circular basewith black synthetic enameled paint and applying two coats of white wash on PCC coping complete all as specified & directed. |
| 29 | Dismantling old ACSR conductor service feeder distribution span and S&F new ACSR conductor of any type and size straching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each pole in span and tightening with permissible sag in between span etc complete all as specified and directed by Engineer-in-charge.Note:-Measurement and payment shall be made for horizontal distance between centres of two adjacent poles and 3 % extra for sag, jointing jumper etc. |
| 30 | Dismantling of old rusted cross arms etc and S&F new cross arms, bracings, supports, clamps, back plates etc, fabricated from structural steel section including bolts, nuts, washers, welding, bending to shape, drilling holes etc and painted with two coats of aluminium paint over one coat of red oxide primer complete all as specified and directed. |
| 31 | Dismantling of old unserviceable shackle typeand S&F new shackle type porcelain vitreous white/brown/green insulator of size 75mm height and 90mm dia, suitable for 1100 Volt gradeincluding galvanized mild steel straps of size 31x3 mm, washers, bolts and nuts etc complete all as specified and directed. |
| 32 | Dismantling of old unserviceable pin type insulator and S&F new pin type porcelain, vitreouswhite/brown/green insulator of size 150mm height and 150mm dia for 11000 volt grade including one galvanized mild steel spindle and two galvanized iron washers and nut etc complete all as specified and directed. |
| 33 | S & F Thermoplastic Cable Junction Boxes halogen free IP 66/69 “weather proof”, for outdoor installation (with knockouts for cable entry - Black colour ) for cable size 4-10 sqmm, size 130x 180x 77 mm with terminals, suitable mounting clamp to accommodate one MCB SP 230V, 6 Amp with Aluminium bus bar 4 Nos complete all as specified and directed. |
| 34 | S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 35 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp with suitable size bracket and clamp, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 36 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with multi stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of steel conduit with 1.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed.Note:- Two runs of 2.5 sqmm cable, one run of 1.5 sqmm cable and one run of steel conduit 19 mm will be measured as one unit |
| 37 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 38 | S&F in replacement MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 39 | S&F in replacement MCCB 4 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 40 | S&F in replacement MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 41 | S&F in replacement MCCB 4 Pole, 415 V, with adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 42 | Taking down existing unserviceable Volt Meter and S&F new Volt Meter (0-500V), 3 phase, 415 volt complete all as specified and directed. |
| 43 | Taking down existing unserviceable Amp Meter and S&F new Amp Meter of0-200 Amps with CTs complete all as specified and directed. |
| 44 | Supply and fix in replacement Aluminium bus bar in the panelof existing size and capacity for phase and neutral with heat shrinkable including PVC sleeves in different colour codes for phase indication all as per directed. |
| 45 | Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearancesoft/loose soiland getting outincluding spreading of anti vegetation chemical on complete Area all as directed and specified. |
| 46 | M&L in repair/replacement for earthingcomplete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6.0 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plateusing 32X6 mmGI earth strip as earth lead moulded and riveted to earthplate at one end and connected to main equipment at switch/control board at another end, GI earth leadincased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) complete all specified and directed. |
| 47 | M & L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-1 with 50 mm thick Pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately. |
| 48 | Taking down existing street light fitting/ flood light fitting (LED 18 to 200watts) any type from poles/walls, de-assembling, testing of parts for serviceability, sorting serviceable and unserviceable parts, replacing unserviceable parts,re-assemblingusing new accessories including S&F new copper wire 3 core 1.5 sqmm of suitable size of making internal connections, testing and re-fixing in position complete all as specified and directed.Note:- New spare parts replaced shall be measured and paid for separately under respective items of Schedule ‘A’. |
| 49 | Supply only Electronic driver of LED 18/20 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 50 | Supply only Electronic driver of LED 25 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 51 | Supply only Electronic driver of LED 35/40 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 52 | Supply only Electronic driver of LED 45 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 53 | Supply only Electronic driver of LED 60 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 54 | Supply only Electronic driver of LED 70 Watt, suitable forexisting LED security light complete all as specified and directed. |
| 55 | S&F in replacement of PVC jumper cable of size 95 Sqmm aluminium, single core suitable for 1100 volts and removing the old burnt/ worn out jumper complete all as directed. |
| 56 | All as per srl item No 55 here-in-before but of size 70 sqmm. |
| 57 | Supply and fixing ofmicro prismatic reftective sheet, min 2.5 cm wide, with adhesive base for dirtectly fixing on LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed. |
| 58 | Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed. |
| 59 | M&L for disconnecting all electrical connections, dismantling switchgears from the Panel and preparing old painted surface of panel board by cleaning removing of the old paint by scraching with wire brush/sand paper etc and including denting/patching of broken/rusted surfaces and replacing Broken door etc and apply two coat of synthetic enamel paint by spray painting on inside/outside surface of panel and refixing all the switchgears & making electrical connections, testing complete all as specified and directed by Engr-in- charge. |
| 60 | Supply, installation, commissioning and testing of powder coated factory made CPRI approved out door type double door panel board confirming to IP 64 protection, of suitable size made of Robust steel sheet construction made from min 3.0 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket around doors, with provision of Lock inserts, earthing straps, wiring plan pockets, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedestal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) copper bus bar system of capacity 400 Amp capacity for phase and neutral where the switchgears can directly be fixed on or with the bus bars without drilling into the bus bars.(b) Incoming MCCB 4 pole 400 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nos(c) Outgoing MCCB 04pole 160 Amp 36KA alongwith Spreader terminals with adjustable thermal setting– 04 Nos )(d)Digital volt meter 0 to 500 volt with selector switch – 01 No(e)Digital Amp meter 0 to 500 Amp with CT of suitable ratio and selector switch – 01 No(f) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three |
| 61 | Supply, installation, commissioning and testing of powder coated factory made CPRI approved out door type double door panel board confirming to IP 64 protection, of suitable size made of Robust steel sheet construction made from min 3.0 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket around doors, with provision of Lock inserts, earthing straps, wiring plan pockets, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) copper busbar of size 50x5 mm and capacity 600 Amp capacity for phase, neutral.(b) Incoming MCCB 4 pole 400 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nos(c) Outgoing MCCB 4 pole 250 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos(c) Outgoing MCCB 4 pole 200 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting – 02 Nos(c) Outgoing MCCB 4 pole 160 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos(e)Digital volt meter 0 to 500 volt with selector switch – 01 No(f)Digital Amp meter 0 to 300 Amp with CT of suitable ratio and selector switch – 01 No(g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of threeNote :- All incoming/out going MCCB should be with suitable size copper strip from main busbar to spreader terminals |
| 62 | Supply, fabricating and fixing, in replacement of, powder coated MS busbar chamber of minimum size of 900 x 600 x 300 mm, made out of CRCA MS Sheet 2 mmthick, front openable with locking arrangement, double door type, duly provided with aluminium bus bar of size 50 x 6 mm colour coded with heat shrinkable PVC sleeves for phases and neutral, fixed on SMC/DMC insulator, weather/vermin proof duly provided with PU gasket alond the door, fixed on 50x50x6mm angle iron 4 leg frame duly grouted in P:C:C (1:2:4) (Each leg 50cm grouted in ground/floor and 50cm above floor level, with and including one no of incomer MCCB 250 Amps, 36 kA, 3 pole, thermal magnetic release, ICS = 100% ICU with and including Spreader Terminals, including making connection complete all as specified and directed. |
| 63 | All as per srl item No 62 here-in-before but of size 600 x 600 x 300 mm size and without MCCB. |
| 64 | Supply, installation, testing and commissioning in repair Automatic street light timer Panel 6 KW, factory made Conforming to IS/IEC 60947-4-1 Provided with Protection Degree IP 54, with extended wide band coil, with FRLS (Fire retardant low smoke) Internal wiring, with In-built Short-Circuit Protection, Class H Insulation, sheet metal body as a pole mountablewith 32 Amp three phase Contactor, 24 Hr digital time switch, 40 Amp TPN MCBwith proper lugs& terminal blocks. The panel enclosure comes complete with openable door and mounting clamps. Make: Havells IHXTS03060 or equivalent in Schneider/ L&T all as directed by Engr-in-charge. |