}

Tender For E-Tender For Rate Contract For Supply Of Lifesaving Product (Item) Used For Implantation Of Lifesaving Permanent Implant Product (Item), Used For Lifesaving Cardiac Operations And Cardiac Procedures (Adult, Paediatric & Neonatal) - Oxygena, Ahmedabad-Gujarat

Tender Notice

51529987
Corrigendum : Tender For E-Tender For Rate Contract For Supply Of Lifesaving Product (Item) Used For Implantation Of Lifesaving Permanent Implant Product (Item), Used For Lifesaving Cardiac Operations And Cardiac Procedures (Adult, Paediatric & Neonatal) - Oxygena
Tender
Indian
Gujarat
Ahmedabad
04-11-2025

Tender Details

E-Tender For Rate Contract For Supply Of Lifesaving Product (Item) Used For Implantation Of Lifesaving Permanent Implant Product (Item), Used For Lifesaving Cardiac Operations And Cardiac Procedures (Adult, Paediatric & Neonatal) - Oxygenator & Tissue Stabilizer- Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 5001 To 8000 Ml/Min - Static Priming Vol: 180 To 350 Ml - Maximum Hardshell Reservoir Capacity: 4000 To 4500 Ml - Minimum Hardshell Reservoir Capacity: 200 To 300Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 7000 To 8000 Ml/Min - Membrane Surface Area: 1.8 To 2.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 5001 To 8000 Ml/Min - Static Priming Vol: 180 To 350 Ml - Maximum Hardshell Reservoir Capacity: 4000 To 4500 Ml - Minimum Hardshell Reservoir Capacity: 200 To 300Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 7000 To 8000 Ml/Min - Membrane Surface Area: 1.8 To 2.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 4000 To 6000 Ml/Min - Static Priming Vol: 120 To 175 Ml - Maximum Hardshell Reservoir Capacity: 3000 To 4200 Ml - Minimum Hardshell Reservoir Capacity: 70 To 150 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 4000 To 5000 Ml/Min - Membrane Surface Area: 1.0 To 1.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 4000 To 6000 Ml/Min - Static Priming Vol: 120 To 175 Ml - Maximum Hardshell Reservoir Capacity: 3000 To 4200 Ml - Minimum Hardshell Reservoir Capacity: 70 To 150 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 4000 To 5000 Ml/Min - Membrane Surface Area: 1.0 To 1.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 2000 To 3000 Ml/Min - Static Priming Vol: 90 To 145 Ml - Maximum Hardshell Reservoir Capacity: 1600 To 3000 Ml - Minimum Hardshell Reservoir Capacity: 15 To 70 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 2000 To 3000 Ml/Min - Membrane Surface Area: 0.6 To 1.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 2000 To 3000 Ml/Min - Static Priming Vol: 90 To 145 Ml - Maximum Hardshell Reservoir Capacity: 1600 To 3000 Ml - Minimum Hardshell Reservoir Capacity: 15 To 70 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 2000 To 3000 Ml/Min - Membrane Surface Area: 0.6 To 1.5 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 801 To 1500 Ml/Min - Static Priming Vol: 46 To 90 Ml - Hardshell Reservoir Capacity: 600 To 1500 Ml - Cardiotomy Filter: 20 To 40 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Membrane Surface Area: 0.27 To 0.50 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 801 To 1500 Ml/Min - Static Priming Vol: 46 To 90 Ml - Hardshell Reservoir Capacity: 600 To 1500 Ml - Cardiotomy Filter: 20 To 40 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Membrane Surface Area: 0.27 To 0.50 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: Upto 800 Ml/Min - Static Priming Vol: 30 To 45 Ml - Hardshell Reservoir Capacity: Upto 500 Ml - Cardiotomy Filter: 20 To 40 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Membrane Surface Area: 0.20 To 0.26 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir And Cardiotomy Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: Upto 800 Ml/Min - Static Priming Vol: 30 To 45 Ml - Hardshell Reservoir Capacity: Upto 500 Ml - Cardiotomy Filter: 20 To 40 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Membrane Surface Area: 0.20 To 0.26 M², Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 5001 To 8000 Ml/Min - Static Priming Vol: 180 To 350 Ml - Maximum Hardshell Reservoir Capacity: 4000 To 4500 Ml - Minimum Hardshell Reservoir Capacity: 200 To 300Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 7000 To 8000 Ml/Min - Membrane Surface Area: 1.8 To 2.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 6 To 8 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Adult, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 5001 To 8000 Ml/Min - Static Priming Vol: 180 To 350 Ml - Maximum Hardshell Reservoir Capacity: 4000 To 4500 Ml - Minimum Hardshell Reservoir Capacity: 200 To 300Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 7000 To 8000 Ml/Min - Membrane Surface Area: 1.8 To 2.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 6 To 8 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Adult, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 4000 To 5000 Ml/Min - Static Priming Vol: 120 To 175 Ml - Maximum Hardshell Reservoir Capacity: 3000 To 4200 Ml - Minimum Hardshell Reservoir Capacity: 70 To 150 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 4000 To 5000 Ml/Min - Membrane Surface Area: 1.0 To 1.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: Upto 5 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Small Adult, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 4000 To 5000 Ml/Min - Static Priming Vol: 120 To 175 Ml - Maximum Hardshell Reservoir Capacity: 3000 To 4200 Ml - Minimum Hardshell Reservoir Capacity: 70 To 150 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 4000 To 5000 Ml/Min - Membrane Surface Area: 1.0 To 1.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: Upto 5 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Small Adult, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 2000 To 3000 Ml/Min - Static Priming Vol: 90 To 145 Ml - Maximum Hardshell Reservoir Capacity: 1600 To 3000 Ml - Minimum Hardshell Reservoir Capacity: 15 To 70 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 2000 To 3000 Ml/Min - Membrane Surface Area: 0.6 To 1.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 3.2 To 5 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Paediatric, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 2000 To 3000 Ml/Min - Static Priming Vol: 90 To 145 Ml - Maximum Hardshell Reservoir Capacity: 1600 To 3000 Ml - Minimum Hardshell Reservoir Capacity: 15 To 70 Ml - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 2000 To 3000 Ml/Min - Membrane Surface Area: 0.6 To 1.5 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 3.2 To 5 Lit/Min - Low Priming Volume, Inlet And Outlet 3/8 For Paediatric, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 800 To 2000 Ml/Min - Static Priming Vol: 35 To 70 Ml - Maximum Hardshell Reservoir Capacity: 700 To 1500 Ml - Minimum Hardshell Reservoir Capacity: 15 To 30 Ml, - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 800 To 2000 Ml/Min - Membrane Surface Area: 0.3 To 0.7 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 0.7 To 2.5 Lit/Min - Low Priming Volume, Inlet And Outlet 1/4 For Infant And Neonatal, Membrane Oxygenator Efficient Heat Exchanger With Surface Coating - With Hardshell Venous Reservoir, Cardiotomy Filter - Integrated Arterial Filter - With Temperature Probe And Stand Whenever Required - Recommended Max Blood Flow Rate: 800 To 2000 Ml/Min - Static Priming Vol: 35 To 70 Ml - Maximum Hardshell Reservoir Capacity: 700 To 1500 Ml - Minimum Hardshell Reservoir Capacity: 15 To 30 Ml, - Venous Reservoir Filter: 20 To 47 ? - Suction Inlet No.: Minimum 4 - Filtered Quick Prime No.: Minimum 1 - Filter Luer No.: Minimum 2 - Venous Blood Flow: 800 To 2000 Ml/Min - Membrane Surface Area: 0.3 To 0.7 M² Specifications Of Arterial Filter: - Maximum Blood Flow Rate: 0.7 To 2.5 Lit/Min - Low Priming Volume, Inlet And Outlet 1/4 For Infant And Neonatal, Reservoir Capacity: 4000 To 4500 Ml - Suitable For Vavd - Venous Inlet, 1/2 With 3/8 Adapter Venous Reservoir Outlet 3/8 - Vented / Vaccum Port 1/4 - 4 Filtered Ports 1/4, 1 Of Those With 1/4 Luer Lock Adapter - 2 Filtered Port 3/8 - 2 Filtered Luer Lock Ports - 2 Filtered Post Lock - Luer Lock - 1 Non Filtered Luer Lock, Reservoir Capacity: 4000 To 4500 Ml - Suitable For Vavd - Venous Inlet, 1/2 With 3/8 Adapter Venous Reservoir Outlet 3/8 - Vented / Vaccum Port 1/4 - 4 Filtered Ports 1/4, 1 Of Those With 1/4 Luer Lock Adapter - 2 Filtered Port 3/8 - 2 Filtered Luer Lock Ports - 2 Filtered Post Lock - Luer Lock - 1 Non Filtered Luer Lock, Maximum Blood Flow Rate: Up To 6 Lit/Min, - Low Priming Volume - Inlet And Outlet 3/8 - Filter: 40? - Polyester - Leukocyte Reducing Media, Maximum Blood Flow Rate: Up To 6 Lit/Min, - Low Priming Volume - Inlet And Outlet 3/8 - Filter: 40? - Polyester - Leukocyte Reducing Media, -, -, -, -, -, -, -, -, -, -, -, -

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-10-2025 04-11-2025
2 11-10-2025 24-10-2025

Key Value

Document Fees
INR 17700 /-
EMD
INR 3069000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail