| 1 | Supply, installation,testing and commissioning of two Split air conditioner controller system ISI mark with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls 2 Air conditioner 30-30 Amps, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor, Auto/Manual facility for all ACswith all installation accessories complete all as specified and directed by Engr-in-Charge. |
| 2 | Supply, installation,testing and commissioning of three Split air conditioner controller system ISI mark with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls 3 Air conditioner 30 Amps each, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor, Auto/Manual facility for all ACswith all installation accessories complete all as specified and directed by Engr-in-Charge |
| 3 | Supply, installation,testing and commissioning of five Split air conditioner controller system ISI mark with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls 5 Air conditioner 30-30 Amps, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor,Auto/Manual facility for all ACswith all installation accessories complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply, installation,testing and commissioning of single air conditioner controller system ISI mark with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls single Air conditioner 30-30 Amps, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor,Auto/Manual facility for all ACs complete with all installation accessories all as directed by Engr-in-Charge |
| 5 | Supply, installation,testing and commissioning of three phase single Air conditioner controller system ISI mark with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 40 Amp, three phase at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls single Air conditioner 40 Amps, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor,Auto/Manual facility for all ACs complete with all installation accessories complete all as specified and directed by Engr-in-Charge. |
| 6 | Supply and Fixing Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of + 5 db 500m range complete all as specified and directed by Engr-in-Charge |
| 7 | Taking down old unserviceablethree phase AC box and supply and fixing Flame proof plug in switch socket, top plug, 5 pin (4P+E) with MCB 40 Amp TPN, 240 Volts, 10 KA suitable for 4.5 TR Vertical type Air Conditioner complete all as specified and directed by Engr-in-Charge. |
| 8 | Supply and fixing flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amp, 250V, 2P+earth including taking down old unserviceable AC box complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for providing sub main wiring with four single core 6.00 Sqmm (nominal area) PVC Insulated FRLS-H multi stranded copper conductor cable 1100 volts grade drawing through stove enamelled steel conduit complete including 6.00 Sqmm PVC insulated FRLS-H single core copper conductor cable for earth wire including taking down/removing old existing wiring and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) four runs of single core 6.00 Sqmm multi stranded copper cable and one run of 6.00 Sqmm earth wire and stove enamelled steel conduit 20 mm dia shall be measured as one run length.(ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item. (iii) Earth wire run inside the steel conduit. |
| 10 | M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLS-H multi stranded copper conductor cable 1100 volts grade drawing through stove enamelled steel conduitcomplete including 4.00 Sqmm PVC insulated FRLS-H single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 4.00 Sqmm multi stranded copper cable and one run of 4.00 Sqmm earth wire and steel conduit 20 mm shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the PVC conduit. |
| 11 | M&L for point wiring for 3 pin 6 Amp socket on independent board controlled by one switch with PVC insulated but unsheathed single core FRLS multistranded copper conductor cable IS-694 markedof size 1.5 Sqmm (nominal area) in and including stove enamelled steel conduit 20 mm dia on walls and making good the surface in CM 1:3 and to the original specification and stove enamelled steel conduit with clamps, gutties etc with including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly complete all as specified and directed. |
| 12 | Supply and fixing flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amp, 250V, 2P+earth |
| 13 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri if not mentioned in BOQ. |