| 1 | M & L for preparation of old plastered surface of wall, ceiling complete removal of existing treatment and washing, rubbing down and stopping of distempered and painted surfaces and applying 2mm thick wall care putty on walls, complete all as specified and directed by Engineer-in-Charge. |
| 2 | M & L for preparation of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/10sqm over and including priming coat of exterior primer applied at 0.90ltr/10sqm complete all as specified and directed by Engineer-in-Charge. |
| 3 | M & L for preparation of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 25gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/20sqm complete all as specified and directed by Engineer-in-Charge. |
| 4 | M & L for preparation of old surface and applying two coats of cement based paint complete all as specified & directed by Engineer-in-Charge. |
| 5 | M&L for preparation of old surface and applying one coat of cement based paint complete all as specified and as directed by Engr-in-Charge. |
| 6 | M & L for preparation of old plastered surface and applying two coats of Oil bounded distemper on walls complete all as specified and directed by Engineer-in-Charge. |
| 7 | M & L for preparation of old surface and applying one coat of Oil bound distemper on walls over a coat of primer complete all as specified and as directed by Engr-in-Charge. |
| 8 | M&L for preparation of old surfaces of ceiling including cornices and apply one coat of white wash complete all as specified and directed by Engineer-in-Charge. |
| 9 | M & L for preparation of old wooden surface exceeding 10Cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge. |
| 10 | M & L for preparation of old steel surface exceeding 10Cm width or girth and apply one coat of synthatic enamel paint complete all as specified and as directed by Engr-in-Charge. |
| 11 | Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed. |
| 12 | M&L brick work with sub class \"B\" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge |
| 13 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc |
| 14 | M & L for rendering 10 mm thick on fair face of brick walls or concrete surface in CM 1:6finished even and fair complete all as specified and directed. |
| 15 | M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4finished even and fair complete all as specified and directed. |
| 16 | M & L for rendering 5 mm thick on fair face of brick walls or concrete surface in CM 1:4 finished even and faircomplete all as specified and directed. |
| 17 | M&L preparation of new surface and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by Engr-in-Charge. |
| 18 | M & L for preparation of new surface and applying two coats of Oil bound distemper on walls over a coat of primer complete all as specified and as directed by Engr-in-Charge. |
| 19 | M&L for preparation of new surfaces of ceiling including cornices and apply two coat of white wash complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed with wooden bead to wooden frame of requered size with nails complete all as specified and directed. |
| 21 | Hacking out old broken glass from metal frame including punching or drilling out old glazingcomplete all as specified and directed. |
| 22 | M & L for 4mm thick plain sheet glass ordinary quality including glazing with putty area area n.exc 0.5 Sqm in each panecomplete all as specified and directed. |
| 23 | Dismantling floor, hearth or wall tilling including cement mortar bedding(but not backing), and rubbish offpremises etccomplete all as specified and directed by Eng-in-Charge. |
| 24 | M & L coloured non-skid ceramic tiles joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Eng-in-Charge. |
| 25 | M & L coloured non-skid ceramic tiles joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqmas in skirting/dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed by Eng-in-Charge. |
| 26 | M&L coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed by Eng-in-Charge. |
| 27 | M&L glazed ceramic coloured tiles 300mm x 200mm x 6to7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed by Eng-in-Charge. |
| 28 | M&L joint free coloured non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 29 | M&L joint free coloured non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles match over and including 10 mm thick rendering in cement mortar 1:3 complete all as specified and directed. |
| 30 | Dismantling of cement concrete tiles/designer tiles of any desciption and any thickness in floors, laid, bedded and pointed in any mortar complete all as specifed and directed. |
| 31 | M&L providing chequered cement concrete coloured tiles glossy finish 25cm x 25cm x 22 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigmentlaid over and includingscreed bed or bedding layer 20 mm thick in CM 1:4 as in floors complete all as specified and directed. |
| 32 | M&L exterior grade heavy duty full body outer designer parking tiles 400x400x10mm, in floors etc. of colour and design as approved by Engr-in-Charge, set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing one including 15mm thick screed bed in CM 1:6 complete all as specified and directed.. Make: Kajaria/Orient bell/H&R, Johnson or equivalent. |
| 33 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Engr-in-charge. |
| 34 | M&L for providing75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate , finished even and fair etc complete all as specified and directed by Engr-in-charge. |
| 35 | M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 36 | M & L for 75mm ThickCement concrete type C-1, 1:3:6 (20mm graded stone aggregate) in Plinth Protection etc. complete all as specified and directed by Eng-in-Charge. |
| 37 | M&L for cement concrete type C2 (1:3:6 ) using 40 mm grade graded coarse agg. in floor,foundations, filling and mass concrete etc. complete all as specified and directed. |
| 38 | Dismantling of AC (corrugated/semi corrugated) sheet/PGI/CGI in roof covering including ridges all as specified and directed by Eng-in-Charge. |
| 39 | S&F 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed by Eng-in-Charge. |
| 40 | S&FAC Serrated ridge two pieces adjustable 6mm thick for corrugated or semi corrugated AC sheets fixed all as specified and directed by Eng-in-Charge. |
| 41 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, all as specified and directed. |
| 42 | Fixing only Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, all as specified and directed. |
| 43 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/roof top lantern/ridge/valley gutter in wall/roof, fixed with self tapping screws complete all as specified and directed. |
| 44 | Fixing only Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/roof top lantern/ridge/valley gutter in wall/roof, fixed with self tapping screws complete all as specified and directed. |
| 45 | Dismantling wrought iron or mild steel work of any description all as specefied. |
| 46 | M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.(Fe- 410W Grade-E-250 quality A). compete all as specefied and directed by E-in-Charge. |
| 47 | S&F Mild steel screw bolts(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with steel & rubber washers and one hexagonal or square nut, etc. compete all as specefied and directed by E-in-Charge. |
| 48 | S & F repairs PVC valveless, syphonic action type, flushing cistern, low level, white colour capacity 10 liters with inlet and outlet, ball valve, handle including cast iron brackets & 32 mm bore PVC flush pipes & PVC connection pipe, compete all as specified and directed. |
| 49 | S&F in repair PVC waste pipe 32/40mm dia610mm longsuitable for WHBorSinksetc complete all as specified and directed |
| 50 | S & F in repairs ball brass valves,high pressure, with polythelne float and fly nutin 20mm bore complete all as specified and directed. |
| 51 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each |
| 52 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) notexc 1.5 sqm each |
| 53 | S & F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and directed . |
| 54 | S & F factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MSframe shall be covered with heat moulded plain colourPVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as shown in SSR Part – I 2009 and as directed by Engineer-in-Charge |
| 55 | S&F Aluminum anodised barrel tower bolt of extruded section and fixed 125 mm long complete all as specified and directed . |
| 56 | S&F 150mm size extruded aluminium alloy handles, fabricated type,anodised complete all as specified and directed . |
| 57 | S&F 250mm aluminium alloy, anodised,sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixingboltts and sliding bolts of extrude section or cast aluminium complete all as specified and directed . |
| 58 | S&F Butt hinges, heavy weight, cold rolled mild steel, and fixed 75mm longcomplete all as specified and directed . |
| 59 | S & F in repairs 15mm PTMT bib cock complete all as specified and directed. |
| 60 | S & F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 61 | S & F in repair grating doom 100mm dia of PTMT of any type(Min weight 25 gms) complete all as specified and directed. |
| 62 | S & F in repair PVC connection pipe 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 63 | Dismantling chain link fencing any type complete all as specified and directed complete all as specified and directed. |
| 64 | Supply & Fixing 75mmx75mmmesh size & 3.4 mm dia of wire chain link MS galvanised fencing complete including line wires, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 65 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground in natural ground complete all as specified and directed. |
| 66 | Excavating in post holes or similar holes for posts or struts each n.exc 0.5 Cum, getting out, and removing surplus soil to a distance n exc 50min soft/loose soil complete all as specified and directed. |
| 67 | S & F Rolled Mild Steel Framed work as in doors or Gates, grills,fencing post, support on wall of angle or other section confirming to Fe 410 -W (Gde-, E- 250) A quality-with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. |
| 68 | M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate,asin foundation filling & mass concrete etc complete all as specified and directed. |
| 69 | M&L in applying two coats of synthetic enamel paints over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed. |
| 70 | Dismantling/Removing of existing barbed wire/razor wire of any descreption/pattern complete all as specified and directed. Note: Each line of wire measured. |
| 71 | S&F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised complete all as specified and directed. |
| 72 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |