| 1 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etcgetting out in soft/ loose soil and levelling of bottom surface to required level complete and as directed. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete and as directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engineer-in-charge. |
| 4 | Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 18cm depthcomplete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose. |
| 5 | M&L brick, sub class \"B\" bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed |
| 6 | Material & labour for cutting / boringto plinth protection / hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable forgivingmechanical protection to cable complete all as directed.(Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site and all as directed by Engineer-in-charge. |
| 7 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area4 core x 25 Sqmm (earthed) complete all as specified & directed. |
| 8 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 50 Sqmm (earthed) complete all as specified & directed. |
| 9 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 95 Sqmm (earthed) complete all as specified & directed. |
| 10 | Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 120 Sqmm (earthed) complete all as specified & directed. |
| 11 | S&F in replacement 40 MM dia GI tubing \"light grade\" with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata / Jindal / Swastik / Prakash Surya |
| 12 | S&F in replacement 50 MM dia GI tubing \"light grade\" with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata / Jindal / Swastik / Prakash Surya |
| 13 | S&F in replacement 80 MM dia GI tubing \"light grade\" with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata / Jindal / Swastik / Prakash Surya |
| 14 | M&L Electrical insulating rubber mat of size (3 mtr X2 mtr X5mm ) tested for LT Voltage1100 Volts complete all as specified and directed by Engr-in - Charge. |
| 15 | Material & labour for continuousbrick edging with width equal to the depth of bricksub class \"B\" laid dry on end vertically, including necessary excavation andremoving surplus spoil to a distance notexceeding50m complete all as specified and as directed. |
| 16 | M&L for providing loose filling with broken stone aggregate 40 mm to 50 mm size structure from ground level grouted below ground level complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth leadusing GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron40 mm dia medium grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, providing FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape, PGI funnel with wire mesh charcoal/salt, funnel etc complete all as directed incl taking out old unsv earthing complete. |
| 18 | M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected tocopper earth leadusing 20×3mm copper strip as earthing lead means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron40 mm dia medium grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, providing FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape, PGI funnel with wire mesh charcoal/salt, funnel etc complete all as directed incl taking out old unsv earthingcomplete all as specified and directed. |
| 19 | M & L for digital printing on 5 mm thick Acrylic sheet wih aluminium bidding with provn of eyelidsspecified font size ,color of letter complete all as specified & directed by Engr-in-charge. |
| 20 | M& L for writing in Hindi or english on wall or steel surface by prepairng the surface by one coat paint,color and font size of letter and matter will be provided by department complete all as specified & directed by Engr-in-charge. |
| 21 | Supply and fixing Rolled Miled steel Framed work as cable trench cover confirming to Fe 410-W (gde-E-250) quality-A with gusset plates, rails braces, etc. complete, drilled for fixing of steel sheeting or other covering and hanging and fixing including taking out rusted frame complete with plaster and brick work as per site requirement complete all as specified & directed by Engr-in-charge. |
| 22 | Material & Labour for chemical to burn out the shrub/grass/ unwanted small trees etc 100%in outfit area of near building earthing pit ,substn yard in AORspread by using spray gun equallyin a given time interval as directed. Note:Chemical sample shall be supplied in sealed container 2 to 5 Ltrs each complete all as specified & directed by Engr-in-charge. Make :- Glycel or equivalent |
| 23 | M & L for plain cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) for foundation of poles, Stay assembly, struts, etc. including all necessary formwork complete all as specified & as directed. |
| 24 | M & L for plain cement concrete (1:2:4) type B2 (using 40mm graded stone aggregate) for foundation of poles, Stay assembly, struts, etc. including all necessary formwork complete all as specified & as directed. |
| 25 | Supply and fixing in repair new generation energy saving & environmental friendly long life LED flood light 100 watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED\"s with secondary optical lances, high efficiency >120 lm/W with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making electric connection with three core copper cable with all accessories completeall as specified and directed. |
| 26 | Supply and fixing in repair new generation energy saving & environmental friendly long life LED flood light 150 watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED\"s with secondary optical lences, high efficiency >120 lm/W with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making electric connection with three core copper cable with all accessories completeall as specified and directed. |
| 27 | S&F in repairLT cable junction box dust and whether proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, factory made, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box ,consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 nos and provision of incoming and outgoing PVC insulated cable with grommets including inbuilt 6 Amp MCBSP 10 KA-01 No comlete all as specified and directed. |
| 28 | Supply and fixing in replacement of old unserviceable post top lantern with new decorative LED post top lantern 20 watt 230 V AC outdoor type whether proof with powder coated die cast aluminum alloy housing suitable for 40 to 50 mm mounting pipe high efficiency >120 lm/W and equipped with IP66 protection, with driver and lamp including making electric connection with three core copper cable with all accessories completeall as specified and directed. |
| 29 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 400 Amps, rated Ultimate Shortcircuit Breaking Capacity 36 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 30 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 250 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 200 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 160 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 33 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 100 Amps, rated Ultimate Shortcircuit Breaking Capacity 16 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and fixing Adjustable thermal and magnetic release based MCCB 4 Pole 63 Amps, rated Ultimate Shortcircuit Breaking Capacity 16 KAIcu at 415 V, rated short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing UNSV / burnt MCCB from site complete all as specified and directed by Engineer-in-charge. |
| 35 | S&F in replacement Substation sign board made out of 3 mm thick aluminium composite panel sheet 1200 mm x 1200 mm including retro reflective sheeting on both side fixed on 50 mm dia stainless steel pipe of grade -304 (non scratchable) of wall thickness not less than 14 gauge including providing letters of not less than 75 mm height fixed on position with 50 mm dia stainless steel pipe (wall thickness of pipe shall be not less than 14 guage and vertical height of board above GL should be 2.4 m & below GL 60 cm deep ) and stainles steel pipe embedded in PPC 1:3:6 type C-1 using 20 mm graded stone aggregate in post holes of size 250 mm x 600 mm including 6 mm thick mild steel base size 200 mm x 200 mm X 600 mm including 6 mm thick mild steel base plate of size 200 mm x 200 mm x 6 mm thick for anchoring of post applying of two coats of anti corrossive paint on anchoring plate and writing letters and numbers on both sides of the board in English and Hindi (as required at site) should be as per IRC 30-1968 using 3M material, numbers of letters exc 50 but n exc 250 on each of the board etc complete all as specified and directed. Note : Square sign board should be cut in one coenerin half of width & depth of it all as specified by Engr-in-Charge. |
| 36 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri. |