| 1 | 1.1 :Earth work excavation in all soils (including refilling) a. 0 to 2 mt. |
| 2 | b. 2 to 3 mt. |
| 3 | 30 : Ellispattern |
| 4 | 31 : Weathering course |
| 5 | 37.1 : White washing 3 coats(slaked) |
| 6 | 39 : S & F of M.s Grills |
| 7 | 41 : Painting - New \"iron work\" |
| 8 | 52 : PVC Water supply (ASTM)b. 25 mm dia |
| 9 | Electrical arrangements69 : 15 Amp. Power plug |
| 10 | 72 : Box type Fibre Fan hook |
| 11 | 74 : Charges for fixing of \"Fan\" |
| 12 | 76 : 8 SWG wire |
| 13 | 78 : Earthing Station IS3043 (Type I) |
| 14 | ANNEXURE-I2.1.1 : Supplying and filling Gravel |
| 15 | 2.1.3 : Filling crushed stone sand |
| 16 | 3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand) |
| 17 | 6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² |
| 18 | 8.2.1.1 : Standardised concrete Mix M25 Grade concrete. (using crushed stone sand)a) In Foundation and Basement. |
| 19 | b) In Ground Floor |
| 20 | c) In First Floor. |
| 21 | d) In Second Floor. |
| 22 | 9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Ground floor |
| 23 | b. In First Floor |
| 24 | 10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floorsb. In Ground Floor |
| 25 | c. In First Floor |
| 26 | 11.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 70mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floorsa. In Ground floor |
| 27 | 15.2.1: Cuddappa slab 40 mm tk.for C/Bslab. (using crushed stone sand)a. In Ground Floor |
| 28 | 18.1 : Formwork using M.S.Sheeta. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc., |
| 29 | b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works |
| 30 | c.For Square and rectangular columns and small quantities |
| 31 | 26.1 : Flooring in C.C.1:5:10 (using crushed stone sand) |
| 32 | 28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer |
| 33 | 29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand) |
| 34 | 32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx16 to 18mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2% |
| 35 | 33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer |
| 36 | 35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand) |
| 37 | 35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer |
| 38 | 36.1 : Cement mortar Border inC.M. 1:5, 12 mm tk. (using crushed stone sand)b. 75 mm wide |
| 39 | c. 50 mm wide |
| 40 | 38.7 : Plastic Emulsion PAINT including primer for inner walls |
| 41 | 38.7.1 : Plastic Exterior Emulsion PAINT including primer for outer walls |
| 42 | 43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods. |
| 43 | 44.6 : PVC SWR 110 mm dia with ISI marktype- A for Rain water down fall pipe |
| 44 | 52.4.1 : 20mm dia PVC water supply ASTM pipe with UPVC Specials (fully consealed in walls) |
| 45 | 54.1.1 : S & F of 15mm dia half turn CP long body tap |
| 46 | 64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.a. Light point with ceiling rose |
| 47 | b. Light point without ceiling rose |
| 48 | 65.1 :Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point. |
| 49 | 67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself. |
| 50 | 68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places. |
| 51 | 75.1.2 : Supply and delivery of48\" (1200 mm) Fan with ISI mark with Eletronic Dimmer |
| 52 | 77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. |
| 53 | 77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. |
| 54 | 361.5.1: Supplying and fixing of StainFreeNanoPolishcolour Vitrified Tiles of size 60cmx60cmx8mm for flooring (using crushed stone sand) |
| 55 | 379.5.1: S & F of Granite tile of size 2\"x1\", 10mm Thick For kitchen arrangements (jet black) (Sample should be got approved by the Eexecutive Engineer before use) laid over in CM 1:3, 20mm thick (using crushed stone sand)a. In Ground floor |
| 56 | ANNEXURE-II:A1: Supplying and fixing of LED bulbs suitable for fixing it to pendent / bakelite battern holder of best approved varietyb) 12 watts LED bulb for bulk head fittings |
| 57 | A2: Supplying and fixing of 18W LED TUBE LIGHTS 4\" long with necessary fittings and charges for assembling and fixing |
| 58 | A3: Supply and fixing of LED Bulk head fitting for 12W LED Bulb |
| 59 | A4: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings |
| 60 | A5: Supplying and fixing of 40 Amps Earth Leakage Circuit Breaker / Residual Current Circuit Breaker (ELCB/RCCB) with ISI mark etc. all complete and as directed by the departmental officers. |
| 61 | A6: Supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. all complete and as directed by the departmental officers. |
| 62 | A7: Supply and fixing of 20mm dia \"B\" Class GI pipe with ISI mark including cost of pipe and labour charges for fixing etc., all complete and as directed by the departmental officers. |
| 63 | A8: Supply, delivery and fixing of cuddappah slab sink of size 600mm x 600mm x 200mm thick 32mm dia ‘B’ class G.I. waste water pipe and 32 mm dia C.P. waste coupling (sample should be got approved by the Executive Engineer before use) true to spirit level including finishing neatly, and fixing in position complying with relevant standard specifications etc., complete in all floors. |
| 64 | A9: Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End. The MCB\"s having ISI mark of best approved quality etc., all complete and as directed by the departmental officers. |