Name of Work: vkuUn fogkj vkoklh ;kstuk ds CykWd ,y0 fLFkr Hkw[k.M la 502 ls ysdj ftykf/kdkjh dk;kZy; xsV rd jksM ds fdukjs vkWDVkxksuy iksy yxkdj iFk izdk\"k O;oLFkk dk dk;ZA
Sl. No.
Item Description
1
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and RequiredT&P completee in all respect.SOR SI NO641/18(Make - philips / crompton / bajaj / utkarsh)
2
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. SOR SI NO 501/1810 sq. mm 4 core (327-170=157)
3
16 sq. mm 4 core
4
Supply and fixing of plain or pin type copper tin plated cable socket( lug ) to the cable leads, insulating with tape and making connectionetc. complete in all respect as per direction of the Engineer- Incharge. SOR SI NO 504/18 10 sq. mm
5
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 65 and above Protection complete in all respects.SOR SI NO. 1423/18CAT AAA
6
Supply and Wiring of submains with two nos. of 2.5 sq. mm.FRLSHPVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. SOR SI NO. 289/18
7
S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve CAT A. SOR SI NO 1002/18
8
S/F of 2.5mt. long 20mm dia MS earth rod with 6 SWG GI earth wire, nut, bolt & washer etc all complete. A.R. 2022
9
Supply and burying of 600mm x 600mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG G.I. wire in 15 mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal / coke and salt at least 150 mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. SIN-703/18
10
Supply and fixing of following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.SOR SI NO 807/18 (make - L&T / siemens / havells)40 A TPN
11
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. DSR S.I. No. 14.15.1/2022 (make - dure line / line duct)63 mm dia (OD-63 mm & ID-51 mm nominal)@247 X 0.85212=210.47