}

Construction Of Su-Sasthya Kendra (Health & Wellness Centre) (Hwc Type-B)” Atname Of The Facility-Roypara Bolhanja, Area-7405, Mouza-Bolancha, Jl.No.-50, Kh.No-1,Plot No.-1407 G.P.-Islampur, Block-Islampur, Dinajpur Uttar-West Bengal

District Magistrate has published Construction Of Su-Sasthya Kendra (Health & Wellness Centre) (Hwc Type-B)” Atname Of The Facility-Roypara Bolhanja, Area-7405, Mouza-Bolancha, Jl.No.-50, Kh.No-1,Plot No.-1407 G.P.-Islampur, Block-Islampur. Submission Date for this Tender is 16-10-2025. Septic Tank Tenders in Dinajpur Uttar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

51491072
Construction Of Su-Sasthya Kendra (Health & Wellness Centre) (Hwc Type-B)” Atname Of The Facility-Roypara Bolhanja, Area-7405, Mouza-Bolancha, Jl.No.-50, Kh.No-1,Plot No.-1407 G.P.-Islampur, Block-Islampur
Tender
Indian
West Bengal
Dinajpur Uttar
16-10-2025

Tender Details

CONSTRUCTION OF SU-SASTHYA KENDRA (HEALTH & WELLNESS CENTRE) (HWC TYPE-B)” atName of the facility-Roypara Bolhanja, Area-7405, Mouza-Bolancha, JL.No.-50, Kh.No-1,Plot No.-1407 G.P.-Islampur, Block-Islampur- 1 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. 3 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 4 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation. 5 B) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 6 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 7 a) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) 8 b) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). 9 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). 10 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 11 Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety]i) In Ground floor 12 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 13 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 14 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyii) In first floor 15 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyii) In second floor 16 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLi) In foundation & ground floor 17 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLii) In first floor 18 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLiii) In second floor 19 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete worki) In foundation & ground floor 20 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete workii) In 1st floor 21 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete workiii) In 2dfloor 22 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 23 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor 24 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor(c) In 1st floor 25 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor(d) In 2dfloor 26 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) i) In ground floor 27 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) ii) In 1st floor 28 Labour for Chipping of concrete surface before taking upPlastering work. 29 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)i) In ground floor 30 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)ii) In first floor 31 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)iii) In second floor 32 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 33 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (6:1)ii) In first floor 34 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (6:1)iii) In second floor 35 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)i) In ground floor 36 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)ii) In first floor 37 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)iii) In second floor 38 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 39 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thicki) In ground floor 40 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thickii) In first floor 41 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thickiii) In second floor 42 Extra cost of labour over grey artificial stone for(i) Chequering 43 (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturers specification [Cement to be supplied by the Department] 44 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor)(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light ColourGround Floor 45 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor)(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour1st Floor 46 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] Ground Floor 47 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] 1st Floor 48 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeGrond Floor 49 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative1st Floor 50 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeGround Floor 51 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative1st Floor 52 Rendering the surface of walls and ceiling with white cement based wall putty (thickness not less than 1.5 mm.)i) In ground floor 53 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface.a) Two coats 54 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsi) In ground floor 55 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsii) In first floor 56 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsiii) In second floor 57 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsioni) In ground floor 58 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsionii) In first floor 59 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsioniii) In second floor 60 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm 61 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 25 mm thickIn ground floor. 62 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 25 mm thickIn 1st floor. 63 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.i) In ground floor 64 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.iii) In second floor 65 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.i) In ground floor 66 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.ii) In first floor 67 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) 68 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 69 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -b) On steel or other metal surface :i) Two coats (with any shade except white) 70 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing filmi) Natural Whitea) 2-track sliding window + b) 3-track sliding window 71 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, doorvertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc)10-12 Micron thickness Annodizing film Natural white 72 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowi) Top, bottom and sidemember 73 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowii)Louvered Section 74 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowiii) Cleat angle ( Non-annodized) 75 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingi) Top, bottom and side member. 76 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingii)Mullion. 77 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingiii)Glazing clip. 78 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(vii) 100x75x4.00 mm 79 Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.(a) 100 mm 80 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units(iv)fixed glazing 81 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units(v)Louvered window 82 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i) 4mm thick clear glass. 83 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.viii) 6mm thick coloured / tinted / smoke glass. 84 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.viii) 8mm thick coloured / tinted / smoke glass. 85 Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesnt exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturers specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)(a) Normal Quality : Film Thickness - 1.0 Mil, Glare Reduction > 45%, U factor < 1.15 86 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.(C) Both side decorative lamination(II) Interior Grade(ii) 12mmi) In Ground Floor 87 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.(C) Both side decorative lamination(II) Interior Grade(ii) 12mmii) In First Floor 88 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(iv) 125 mm grip x 10 mm dia rod. 89 Supplying, fitting & fixing Stainless Steel D or H type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges. 90 ii) Godrej Hydraulic door closer fitted and fixed complete.(b) Medium type 91 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(vii) 225mm long x 10mm dia. bolt 92 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iv) 150mm long x 10mm dia. bolt. 93 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting(b) 250mm long. 94 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii)110 mm. Dia. 95 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.a) Plain Tee(ii)110 mm. Dia. 96 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.b) Plain Y(ii)110 mm. Dia 97 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.c) Bend 87.5 degree(ii)110 mm. Dia. 98 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.d) Shoe(ii)110 mm. Dia. 99 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) 100 Printing New Letters and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) English and Roman 101 Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm 102 Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] 103 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge.(Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film.Natural white.a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm(unit wt of Top, bottom & side member @1.366 kg/m ; intermediate member @ 1.443 kg/m; glazing clip: 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M] 104 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge.(Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film.Natural white.b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm(unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) 105 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. 106 Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(i) 16 mm dia bolt (a) 300 mm long 107 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Exposed WorkPVC Pipes40 mm 108 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes15 mm 109 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes20 mm 110 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes25 mm 111 Supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)(ix)15 mm dia 112 supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)viii) 20mm 113 supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)(vii) 25 mm dia 114 Supplying, fitting and fixing bib cock or stop cock.a)i) chromium platedbib cock short body (equivalent to code no. 511 & model- tropical./ sumthing special of ESSCO or similar brand) 115 Supplying, fitting and fixing bib cock or stop cock.(d)i) chromium plated angular stop cock with wall flange (equivalent to code no. 5053 & model- Florentine of Jaquar or similar brand) 116 Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer.(c) 1500 litre capacity 117 Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. 118 Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. 119 Labour for punching hole in plastic water storage tank up to 50 mm dia. 120 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.ii) 550 mm X 400 mm size 121 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.(iv) Angle back wash basin 400 mm X 400 mm 122 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm 123 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia.i) 450mm long 124 Suppling fitting & fixingapproved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clampsi)900mm long 125 Suppling fitting & fixing15 mm swan neck tap with left & right hand operating knob with aerator. 126 Suppling fitting & fixing c.i round gratingi)100mm 127 Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992 A) i) single socketed 3 mtr length --b)110 mm 128 (ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.A) Above ground(ii) 110 mm dia. 129 (ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. A) Under ground(ii) 110 mm dia. 130 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 viii) Double Y with Door b) 110 mm 131 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xi) door bend ( T.S.)b) 110 mm 132 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xv) vent cowl-(b) 110mm 133 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xvi) pipe clip ---(b) 110 mm 134 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Plain Tee---(b) 110 mm 135 Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with P trap 136 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C. (ii) Plastic (hallow type) white 137 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.i) Polythene Flush Pipe 138 Supplying, fitting and fixing liquid soap container.(c) Fibre glass 139 Supplying fitting & fixing best quality indian make mirror 5.5 mm thk. With silvering as per I.S.I specification supported on fibre glass frame of any colour,frame size 550mm x 400mm 140 Supplying fitting & fixing towel rail with two brackets.a)C.P over brush--- i)25mm dia,450 mm long. 141 constructing inspection pit of inside measurement 600mm x600mm x upto 600mm (depth) with 250mm th. 1st. Class brick work in cement mortar(1:4) on all sides bottom of the pit consisting of 100 mm th. Cement concrete (1:3:6) with stone chips over a layer of jhama brick fklat soling, 15 mm thk. (4:1) cement plaster to bottom of the pit providing necessary invert with cement concrete (1:3:6) with stone chips as per direction ,neat cement finishing to entire internal surface top of the pit convered with 100 mmth. R.CC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6mm thk.cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia .R.C.C manhole cover of approved make supplied ,fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth removing spoils after work complete in all respect with all costs of labour and materials.i) With pakur variety (SAIL/TATA/RINL) 142 Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.a) with 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia.For-SAIL/TATA/RINL 143 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C.........(ii) For 20 users(A) With Pakur Variety (SAIL/TATA/RINL) 144 Cement concrete with graded stone balast ( 40mm size excluding shuttering ) in ground floor(A) Pakur variety(a) 1:3:6 Poportion 145 Supply fitting and fixing Fire Exyinguisher conforming to ISI Marked (IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 KGS capacity with intial filling in brand new cylinder with poder coated finish, fitted with gun metal union, discharge house, wall mounting bracket and suitable sinage etc. complete ( Make : Fire Shield/ New age /De Flame/ Andex or equivalent). A level Agency should be pasted on the body of the Extinguisher dully signed& stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/Date of next refiling (warranty card need to be submitted) 146 Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.) 147 Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.) 148 b) Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White 149 Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long 150 Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets. (Model Code No.B2210108 of CERA or equivalent.)750 mm long 151 Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent) 152 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 153 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. 154 B) Filling in foundation or plinth by find sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 155 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 156 Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety]i) In Ground floor 157 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 158 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 159 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a)SAIL/TATA/RINLi) In foundation & ground floor 160 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.ii) Ground floor 161 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 162 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor 163 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) i) In ground floor 164 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 165 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 166 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturers specification.In Ground floor:(iii) Two coats. 167 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thicki) In ground floor 168 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. 169 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.i) In ground floor 170 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 171 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -b) On steel or other metal surface :i) Two coats (with any shade except white) 172 Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment). 173 Supplying and stacking sludge (adequate for Horticulturework) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%). 174 Spreading of sludge, dump manure,/farm yard manure /animel dung manure and good earth in requiredthickness. This includes supply of labour, tools & plantsexcluding materials. 175 Supplying and fixing grasses tiles of grass MaxicanCarpet/Selection No. 1 Healthy & fresh grasses (size 1x1 or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) 176 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.xxvii) Areca Palm 4 - 5 suckers of height 120 cm to 135 cm in earthen pots of size 25 cm. 177 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.iv) Rangon hi-breed healthy plant. 178 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.xvii) Bougainvillea (mix variety) of height 30cm-90cm inpolybag of size 10cm-15cm. 179 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(i) 50 mm dia. boring etc. 180 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(ii) 100 mm dia. boring etc. top enlargement 181 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia)50 mm 182 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia)100 mm 183 Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.(ii) 50 mm dia. 184 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-inchargeincluding cost of all materials labour and equipment complete. 185 Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. 186 Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 187 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.(ii) 50 mm 188 Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm 189 Supplying, fitting and fixing G.I. cap at top(i) 100 mm 190 Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with V notch including hire and labour charges for all tools and plants and scaffolding as required. 191 Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. 192 Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. 193 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. 194 Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. 195 Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately)(iv) 32 mm dia. medium quality 196 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(vi) 32 mm dia 197 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes32 mm 198 Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm.(vi) 50 mm 199 Supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034 (and as amended thereafter) with standard MOC for potable clear cold water and BEE 3 star rared capable of discharging noted M3/hr against head of water column. The pump shall be directly coupled with a continuous rated 2-pole suitable wet type vertical squirrel cage induction morter conforming to IS : 9283 (and as amended thereafter), suitable for operation in AC single phase 220V 50HZ (category B motor) as per specifiation and direction of EIC. 1Ph 230 V , 1.5 HP submersible pump Make- Crompton Groves/ CRI/ Sieners. 200 Supply and delivery of direct on line (DOL) strater panel board conforming to IS13947 and IEC 947 of suitable HP rating for operation in 230 V (±10%) comprising of anmeter, voltameter, thremal overload realy, 2 pole magnatic contactor, undre voltage protection, indicating lamp, capacitor, wiring with 1/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities- as per satisfication and direction of EIC. 1) 1.5 HP (Retay Range 9-14 Amp.) 201 Supplying, delivery & Installation of Submerssible Starter Panel (L&T Make) with appropriate overload and overcurrent protection. 202 Supplying and delivery and fixing of 2.5 Sq.mm 3 core flat PVC cable (Finolex or equivalent) for submerssible pump motor etc. 203 Supplying and fixing C.I. water proof looping cable box having hinged top cover having 4 mm thick with rubber gasket living railway type mechanical locking arrangement earthing terminal with lug etc of size 8X6X4 comprising 3 Nos. 15 amps Kit-Kat fuse unit and housing the same in pole muffing. 204 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. 205 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. 206 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 207 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation. 208 B) Filling in foundation or plinth by find sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 209 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 210 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 211 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 212 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.I. SAIL/ TATA/RINLi) In foundation & ground floor 213 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.ii) Ground floor 214 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 215 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 216 Boring / drilling bore well of required dia for casing/strainer pipe, by sutable method prescribed in IS:2800(Part-I), including collecting sample from different strata, preparing and submitting starta chart/ bore log including hire & running charges of all equipment , tools, plant & machineries required for the job, all complete as per direction of Enginnering-in-charge, upto 90 meter depth below ground level. IS:2800(Part-I), including collecting sample from different strata, preparing and submitting starta chart/ bore log including hire & running charges of all equipment , tools, plant & machineries required for the job, all complete as per direction of Enginnering-in-charge, upto 90 meter depth below ground level. 23.1.1 All type of soil 23.1.13 400 mm dia 217 25.1.2 for Rocky strata including boulders 23.1.2.3 400 mm dia 218 Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm 219 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia 220 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.3 200 mm nominal size dia 221 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 222 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. 223 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 224 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. 225 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.3 200 mm dia 226 Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia. 227 R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cementfinishing and cutting chase fitting and fixing in position, mending good damages as necessary complete.In ground floor(a) 50 mm. Thick panelsI. SAIL/ TATA/RINL 228 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 229 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.a) Plain Tee(ii) 110 mm. Dia. 230 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.c) Bend 87.5 degree(ii) 110 mm. Dia. 231 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.d) Shoe(ii) 110 mm. Dia. 232 Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)PVC Pipes(Dia)80 mm 233 Renewing gully grating.(i) 375 mm X 300 mm X 40 mm X 18 kg New work 234 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length b) 110 mm 235 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A)xv) Vent Cowl b) 110 mm 236 Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications. 237 Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohrs hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturers specification and direction of Engineer-in-Charge.In Ground Floor: Sizes-300 mm x 300 mm x15 mm 238 Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohrs hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturers specification and direction of Engineer-in-Charge.In 1st Floor: Sizes-300 mm x 300 mm x15 mm 239 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 240 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 6 mtr 241 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 7 mtr 242 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 8 mtr 243 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed] Average run 9 mtr 244 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(b) 3 x 22/0.3 (1.5 sqmm) 245 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(s)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 246 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(v)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 247 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 248 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).(b) 19mm dia 3mm thick Polythene Pipe 249 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).(c) 25mm dia 3mm thick Polythene Pipe 250 Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works19 mm dia 3 mm thick polythene pipe without earthcontinuity wire 251 Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire(a) 25 mm dia 3 mm thick polythene pipe without earth continuity wire 252 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works20x10mm Size 253 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works25x10mm Size 254 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i) 2.5sqmm 255 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(ii)4 sqmm 256 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(iii) 6 sqmm 257 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC(i) On Board 258 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr 259 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 260 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 261 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 262 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 263 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections. 264 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 265 Supplym Delivery Installation, Testing and commissioning of indoor cubical type LT distribution panel board along with continuous Neutral & Earthing Indication of required size, wall/stand mounted compertmentalized with maple arrangement having rigid and self supporting structure withcable alloy febricated from 2 mm thick. CRCA sheet steel and M.S. angles frame for panel mounting support and making necessary grouting arrangement with neat cementing finish as per direction of EIC. 266 Supplying and fixing Sheet steel Main Switches onangle iron frame on wall32A DP [Standard/HPL Make] 267 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)2 bars 240 V, 63 A 268 Supplying and fixing Changeover switch with SheetSteel enclosure on flat iron frame on wall with nutsbolts etc32A,240V DP, Make - Standard/HPL 269 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+4 way [EDB 1] (607710) 270 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+8 way [Ground & 1st Floor, NDB 2 & 3] (607711) 271 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+12 way [Ground & 1st Floor, EDB 2 & 3] (607712) 272 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment[Make - Legrand]2 Way [UPS DB] 273 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment[Make - Legrand]4 Way [NDB 1] 274 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Single pole 6-32A [SPNDB Outgoing] MCB 275 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Single pole 25A [EDB1 Outgoing] MCB 276 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB ( EDB1, NDB 2,3) 277 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB ( UPS) 278 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 25A [EDB 2,3 Incomer] 279 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB [NDB 1 (NDB 1-4Way) 280 FIXING OF FANSSupply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 281 FIXING OF FANSSupplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 282 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. 283 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) 284 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)For Al :30 cm Exhaust fan (12) 285 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board 286 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length 287 Supply & Delivery ofsweep 48 inch(1200 mm) AC ceiling fan 50-70 watts, speed >=350 RPM air delivery >= 220 CMM sutable for [ Make-Orient PSPO New Breeze/ Summer Cool /equvalent of EPC of USHA STRIKER PLUS of CROMPTON [Approved by EIC] 288 Supply & Delivery ofsweep 36 inch(900 mm) AC ceiling fan 50-70 watts, speed >=380 RPM air delivery >= 145 CMM sutable for [ Make-Orient PSPO New Breeze/ Summer Cool /equvalent of EPC of USHA STRIKER PLUS of CROMPTON [Approved by EIC] 289 Supply & delivery of heavy duty exhaust Fan of Sweep:-12 inch (300mm), 240 volt, 50Hz, AC, 50-60 Watts, Speed>900 RPM Air delivery >= 145 CMM suitable for [ Make- Orient/ Model Power Flow)/EPC / Havells/ Crompton Greaves) [Approved by EIC] 290 Supply & delivery of wall fan 16 Sweep metal blade ( Crompton Greaves/ Orient/Havells make) 291 Supplying of 1.1 KV. Grade LT power cable XLPE insulated cores laid up, PVC inner sheathed aluminium armoured conductor of the following Specification (make: Polycab/Gloster/Havells) 16 sqmm2 core (A2XWY/A2XFY) 292 Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 293 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core upto 16 sqmm 294 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 16 sqmm cable 295 EARTHING:Soil Excavation :Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil 296 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:[Raw Power-2, UPS:-1]By TATA-Medium GI pipe 297 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 298 Extra for treatment of soil by using salt & charcoal or coke for plate electrode 299 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 300 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 301 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI wireNo. 8 SWG 302 Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required 303 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. 304 Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. 305 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. 306 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works(a) 20mm size 307 Supply & delivery of single 4 battan type LED tube light fitting 1200 mm efficancy >= 100 lm/W THD< 10 %complete with all accessories [Make havells/LED Pride Plus NXT Batten 22 W 6500K) or equivalent of Philips, Crompton etc. [Approved by EIC] 308 Supplying & Fixing Out door type CFL/LED luminaire (Havells make- LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp incl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. 309 Supply & Delivery at site of 9 Watt LED Bulb Efficancy>= 90lm/W Base Cap :- B22 (Make- Havells, LEDDEKOR BULB 9W B22 CDL] or equivalent Crompton, Philips etc.[Approved by EIC] 310 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener 311 Fixing only lamp 312 Supply & delivery of 550 Wp or above Mono-PERC/N-Type TOPCON, 144 Half-Cell Monofacial/Bifacial Module with Min. Module Efficiency 21.3%, IEC & BIS Certified (Manufactured in India) with Annual Degradation Not More Than 0.60%. [Manufacturers Authorization is mandatory].[Make:- RenewSys/Panasonic/Waaree][Approved by EIC] 313 Solar InverterSupply & delivery of Single Phase Hybrid Inverter with Inbuilt MPPT Charge ControllerSize: 3.5 KVA/48 Vdc.[Manufacturers Authorization is mandatory].[Make:- Luminous/Flin Energy/Deye][Approved by EIC] 314 Supply & delivery of Module Mounting Structure of HDGI (86 Micron) with Initial Height of 500mm from Roof Level, Withstand Wind Speed of 150 Km/Hr. (Min 56 kg/kW) with All SS304 Fasteners 315 Lead Acid Battery (ESS)Supply & delivery of Solar VRLA Gel Maintenance Free 12V-100Ah Battery @50% DOD with Battery Cable & Accessories (5 Years Warranty)[Make:- Exide/Luminous/Amara Raja][Approved by EIC] 316 DC Solar CableSupply & delivery of DC Solar Cable 1C x 10 Sqmm 1.5 kV Grade XLPO Insulated Tinned Copper (UV Outdoor Cable)[Make:- Polycab/APAR/LAPP][Approved by EIC] 317 Earthing CableSupply & delivery of Earthing Cables 1C x 25 Sqmm 1.1 kV Grade PVC Insulated Flexible Copper G/Y[Make:- Polycab/Mescab/KEI] [Approved by EIC] 318 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC 319 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 320 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 321 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+4 way [Enclosure (DHDPSNODRW04)] [Solar Main AC DB][Make:- Havells/Legrand/BCH] [Approved by EIC] 322 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+8 way [Enclosure (DHDPSNODRW08)] [Solar AC DB-Gr. & 1st Fl.][Make:- Havells/Legrand/BCH] [Approved by EIC] 323 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.32A DP Isolator [For Solar Main AC DB][Make:- Havells/Legrand/BCH] [Approved by EIC] 324 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection6-32A SP MCB [Solar AC DB-Gr. & 1st Fl.][Make:- Havells/Legrand/BCH] [Approved by EIC] 325 Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc32A 240V DP Changeover Switch[Make:- Standard/L&T/BCH] [Approved by EIC] 326 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(a) 150 mm x 100 mm x 65 mm 327 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works(a) 150 mm x 100 mm x 65 mm 328 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(a) 100 mm x 100 mm x 65 mm 329 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(b) 150 mm x 100 mm x 65 mm 330 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required(b) 150 mm x 100 mm x 65 mm 331 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 332 Supply & Delivery of 24V DC Battery Cable Set with MCB Configuration[Make:- Polycab/Mescab/KEI] [Approved by EIC] 333 AC-DC Distribution BoxSupply & Delivery of AC-DC Integrated Distribution Box with Over Current (PV Fuse 1000V 15A) & Surge Protection (DC & AC SPD Type 2)[Make:- Fender Energy/Earth Energy Solutions] [Approved by EIC] 334 Earthing & Lightning Protection WorkEarthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below:-By TATA-Medium GI pipe [AC DB Earthing] 335 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [AC DB Earthing] 336 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [AC DB Earthing] 337 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 338 Supply and Delivery of 1 x Copper Air Terminal with Mast, 2 x 2m x 17.2mm Copper Bonded Earth Electrode, 2 x Backfill Compound, 2R x 16Sqmm Flexible Copper Earthing Cable, 2 x CI/FRP Pit Chamber CoverPit at DC Side: 2 Nos. 339 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes Pakur variety [for fixing of mounting structure on roof slab] 340 Fire ExtinguisherSupply, Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC04 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B 341 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building worksb) 25mm size 342 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.With out angle iron support [100x50x1.25mm (18SWG)] 343 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i) 2.5sqmm 344 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(ii) 4 sqmm 345 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(iii) 6 sqmm 346 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:- upto 2.5/4 sqmm 347 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:-upto 6 sqmm 348 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:-upto 25 sqmm 349 Supply & Delivery of MC4 Connectors, PVC/M.S. Saddles, Bullets, Screws, Fasteners, Ferrule, Cable Tie, Spare Tools, Caution Board, Safety Signage and other Electrical Accessories as required for setting up of 2.2 kWp solar power plant 350 SITC & Comprehensive Maintenance of Solar PV Power PlantDesign, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (2.2 kWp) at Su-Swasthya Kendra (Type-B) 351 Control PanelSupply, installation, and commissioning of a microprocessor/microcontroller-based, networkable, intelligent, analogue addressable single-loop control panel, expandable up to 4 loops. The control panel is designed with ARM Cortex-M4 32-bit Microcontroller with high resolution (480 X 272 pixels) 4.3 inch graphics TFT LCD displaywith symbolic representation for power status, displays color-coded events (like Red, yellow & Amber ).The system status and control keys with symbolic representation for easy access.The control panel has inbuilt multilingual features (English and Bengali).The panel status shall be visualized on LCD/LED in unambiquese color. The system should support for the 140 Nodes maximum in a Network including Repeater panels & NAC Extender Power supply panels. The total Network Distance shall cover upto 16 Kms for peer to peer network and 1.2 Kms for Repeater & NAC Extender power supply panel network. This panel can operate as a standalone or connect up to 16 panels in a network via Network Interface Card (NIC) for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the panel configuration using the Configuration tool, Two inbuilt programmable inputs, Two inbuilt programmable NACs with short circuit protection, Programmable 24VDC (Steady/Reset) and TwoProgrammable Relays, One dedicated Fault Relay, 10000 events log with RTC, Numaric keypad for menu access. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of 250 intelligent analog addressable devices in one loop in anycombinations including loop powered sounder,sounder-strobe etc. the system has high reliability with the capacity to support 16,000 devices in any combination. The central processing unit shall containand execute all [Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] [Including 5 Years Comprehensive Warranty] 352 Addressable Multi SensorSupply ,Installation and Commissioning of analog Addressable Multi Sensor - Heat Cum Smoke detector with ROR featues to raise an alarm when the temperature reaches 11.1°per Minute withbase, Binary coded address setting DIP switch. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. Approval: UL or FM.[Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 353 Addressable Manual Pull StationSupply, Installation and Commissioning of analog Addressable Manual Pull Station - DoubleAction with inbuilt fault isolator, shall be resettable by Key lock access to avoid unauthenticated restorations,FR - ABS Housing, monitoring the field NO/NC devices. Shall have Binary Coding Setting Dip Switch, The MCP shall have operating temperature range from 0°C to 49°C and humidity tolerance range up to 93% RH, Non-Condensing. Complete with termination and testing as per requirement and as per specification. [Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 354 Supply, Installation and Commissioning of Manual Pull station back box (Single Gang Box) compatiable with manual pull station single/dual action equipped with blinking LED for normal condition and steady LED for manual pull station activated condition along with 8 way dip switches for addressing the devices.[Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 355 SounderSupply, Installation and Commissioning of wall mount loop powered sounder - Strobe withbuiltin isolatorfixing box having minimum sound pressure level of 85dBA @3mtr, Flash intensity should be 15cd minimum Candela Low and High can be selected from FACP,flasherfrequency1HZ per second, shall have 8 Different tone selection from FACP ,Adjustable volume control,Sounder and strobe OFF facility.It shall be RED in colour.Complete with termination and testing as per requirement and as per specification,Material -FR ABS Plastic,Temperature range 0-49deg C , Shall have Binary Coding Setting Dip Switch,Dimensions (100.5 D x 72.25H)mm. Cable wiring for the termination should be at base of sounder and head shall be installed seperately. IP Rating- IP60 356 CableSupply ,Installation and Commissioning of armoured 2 C X 1.5 Sq mm FRLS Twisted Pair Tinted copper multistranded cable (Red Color) for Fire Alarm System. Complete with termination and testing as per requirement and as per specification.[Make:-Finolex/ Plaza/Polycab/ RR Cable] [Approved by EIC] 357 LT Distribution, MCB DB & Switch BoardWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.(b) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 358 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment2 Way 359 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection10A SP MCB [For FDA Control Panel][Make:- Havells/Legrand/BCH] [Approved by EIC] 360 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(d) 240 mm x 200 mm x 65 mm 361 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(e) 240 mm x 200 mm x 65 mm 362 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required(e) 240 mm x 200 mm x 65 mm 363 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 364 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i)2.5sqmm 365 Supplying and Fixing of Junction boxes, Cable glands, Connector, Screws etc. fixing accessories for SITC of Detectors, MCP and modules. 366 Supply, Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC(Location:- at Electrical Room under Ground Floor Staircase)04 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B 367 Supply, fitting and fixing including all necessary arrangement for complete installation of wall mounted Water Purifier having storage capacity- Not less than 8L, RO+UF+TDS control +UV In-Tank+ Copper Water Purifire, Purification Production Rate -Not Less than 15 L/hr with 1 Year Warranty + 3 Years Exteded Service Free (including all taxes, Mraket Rate) [Make-Kent/ Aquaguard/LG/Equivalent]

Key Value

Document Fees
Refer document
EMD
INR 125272.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail