| 1 | Dismantling of following existing structures of any decription and nature at any place and position as per site requirement and instruction of site-in-charge including shifting/cleaning the materials from site. Complete in all respect as directed by EIC. Taking Down & removal to store Chowkhats or frames of Doors & windows exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) |
| 2 | Dismantling of following existing structures of any decription and nature at any place and position as per site requirement and instruction of site-in-charge including shifting/cleaning the materials from site. Complete in all respect as directed by EIC. Dismantling cast iron work of any description |
| 3 | Dismantling of following existing structures of any decription and nature at any place and position as per site requirement and instruction of site-in-charge including shifting/cleaning the materials from site. Complete in all respect as directed by EIC.Demolitionof Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 4 | MS FRAME WORK : Supplying & fixing MS frame work confirming to Fe 410 -W (Gde- E- 250) quality- A. rate including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up drilling the members for site connections; and fixing painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete.MS Plates 600mm x 600mm x 5mm Thick (plain or chequered) conforming to Fe 410-W (Gde-E- 250) quality-A channels, square cut or notched (ordinary and counter sunk) |
| 5 | MS FRAME WORK : Supplying & fixing MS frame work confirming to Fe 410 -W (Gde- E- 250) quality- A. rate including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up drilling the members for site connections; and fixing painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete. Fixing of MS Plates as mentioned above with Anchor Fastner - M10 |
| 6 | Providing and fixing double scaffolding system (cup lock type) onthe exterior side ofbuilding/ structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge |
| 7 | JACKETING OF COLUMN :Providing and laying in position site batched cement concrete for reinforced cement concrete work; using coarse aggregate 20mm stone chips and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including of laying, curing, carriage for all leads; as per direction of the engineer-in-charge; upto Plinth Level. Concrete of M25 grade (1:1:2) with minimum cement content of 330 kg /cum |
| 8 | Excavating over areas in hard/ dense soil, n exc 1.5 m deep and getting out |
| 9 | Selecting stone, brick, concrete, etc. suitable for handpacking, filling of hardcore from excavated spoil heaps, removing and piling in convenient places within 50m of spoil heaps, etc. and raising or lowering to required level (measured after selection) |
| 10 | Sand filling under floors or in foundations including watering and consolidation |
| 11 | Providing PCC type B-1, 1:2:4 (20 mm aggregate) in foundation filling Floor, Mass Concrete.M&L |
| 12 | RCC : Reinforced cement concrete type B-1, 1:2:4 (20 mm aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 13 | Finishing cement concretesurface even and smooth without using extra cement |
| 14 | STEEL REINFORCEMENT : TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 15 | BRICK WORKS : Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement morter 1:4 |
| 16 | PLASTERING :Renderingcement plaster 12 mm thick on fair faces of brick work or concrete surfaces.: cement plaster 1:4. Rendering is to be finished even & smooth without using extra cement. |
| 17 | NET FINISHING EXTRA CEMENT :Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4, including the additional thickness is provided as floating/setting coat. |
| 18 | 12mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive to be fixed on ceiling. Material & Labour |
| 19 | STEEL WINDOWS: Taking down and refixing in same opening only Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded. |
| 20 | STEEL WINDOWS: Supply only Mild steel in flat, round or square bars, z channel, in available lengths conforming to Fe 410-W (Gde-E- 250) quality- A for repairing of windows. |
| 21 | STEEL WINDOWS: Welding in repairs for Thickness of Metal to be welded Exc. 6mm but n.exc 9mm and exc 2.5cm but n exc 5cm in length |
| 22 | STEEL WINDOWS:Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded |
| 23 | STEEL WINDOWS:Supply & fixing of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 24 | STEEL WINDOWS:Expanded metal weight n. exc. 4Kg per sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members |
| 25 | STEEL WINDOWS:Supply & fixing of Sheet glass 4.00mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, thickness 4.80mm |
| 26 | Supplying Only, Timber 2nd class hardwood (Gamari or equivalent) in clean sawn battens or fillets for repairing of Chowkhats or frames |
| 27 | Supplying Only, Timber 2nd class hardwood (Gamari or equivalent), clean sawn boards or planks, width n exc. 25 cm |
| 28 | abour in fixing or taking down and refixing in same opening, together with all accessory materials such as nails, screws, wedges, plugs, glue, putty, etc. and also for plugging up old screw holes, etc., and for painting one coat on edges of shutters of doors, windows, etc. eased or fitted. Chowkhats or frames with shutters (without taking off shutters from the frame) size exc 1.5 sq. m but n exc 4 sq. m each |
| 29 | Washing, rubbing down and stopping of distempered and painted surfaces. One coat Cement wash with Portland cement slurry to a smooth bodied opaque finish on the surface,Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two coat |
| 30 | The dismantled materials will be contractor\"s property & deduction will be made on these materials.The contractor should visit the site before making quotation. Wooden frame |