| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 2 | Excavating in post holes each n. exc 0.5cum getting out in soft/loose soil, and removing surfaces soil to a distance nexc 50m and making good surfaces complete all as specified and directed. |
| 3 | M&L for PCC (1:2:4) type B-2using 40mm graded stone aggregate as in foundation of posts and pillars etc complete all as specified and directed. |
| 4 | M&L Roof trusses (framed), purlins , rafters , crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) Gde Fe-410 S including distance pieces, cleats etc. complete all as specified and directed. |
| 5 | S&F mild steel work as in tubular poles including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979, complete all as specified and directed. |
| 6 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 7 | Welding in repairs to steel gates, wicket gates, railings, windows , doors, cupboards etc exc 2.5 cm but not exc 5.00 cm in length and thickness of metal to be welded exc 6 mm but n exc 9mm or similar works, complete all as specified and as directed. |
| 8 | S&F of wire netting of galvanised steel wire 1.40mm dia with 20mm size of mess fixed with tinned tacks of wire staples complete all as specified and directed. |
| 9 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. |
| 10 | M&L Pre-painted Galvalume aluminium zinc coating AZ 70 Gsm GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L Pre-painted Galvalume aluminium zinc coating AZ 70 Gsm GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in ridge , hips , gutters etc fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply&fixing110mmborePVC(SWR)pipessinglesocketed(pressureratingnotlessthan 4kg/sqcm)inanylengthwithrubberringjointsfordrainorrainwaterfixedalongwalls/sheetswithand including PVC clamps, complete all as specified and as directed by Engineer-in- charge. |
| 13 | Supply&fixingPVC(SWR)bends(anyradius)suitablefor110mmborepipecompleteallas specified and as directed by Engineer-in- charge. |
| 14 | M&L painting to new steel surface of any description over 10cm width or grith not otherwise described including preparation , priming with zinc chromateand two coats of synthetic enamel paint complete all as specified and directed. |
| 15 | S&F aluminium composite panels of accucell/ gurind/EPP 3 mm thick exterior grade PVDF with foil thick of 0.25mm & frame work made out from aluminium section of size 38x25mm supported on masonry wall/ceiling/RCC/MS framework with the help of MS bracket fixed with brick fastener /anchor fastener and groove filled with silicone weather proof sealant of DOW corning etc incl scaffolding at any height and fixing as in any position as per manufacturer instructions complete all as specified and directed. |
| 16 | S&F in repairs aluminium composite panels of accucell/ gurind/EPP 3 mm thick exterior grade PVDF with foil thick of 0.25mm & frame work made out from aluminium section of size 38x25mm supported on masonry wall/ceiling/RCC/MS framework with the help of MS bracket fixed with brick fastener /anchor fastener and groove filled with silicone weather proof sealant of DOW corning etc incl scaffolding at any height and fixing as in any position as per manufacturer instructions complete all as specified and directed. |
| 17 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 18 | Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 19 | Demolition of brickworkbuilt in cement morterincluding work all quoins, aches, pillars, etc complete all as specified and directed. |
| 20 | M&L for Brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in CM 1:4complete all as specified and directed. |
| 21 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 22 | M&L applying three coats of white wash after preparation of new plastered surfaces of walls, complete all as specified and directed. |
| 23 | Demolition of stone slabs & tiles of anythickness & in any position laid, bedded and pointed in any mortar otherwise specified complete all as specified and directed. |
| 24 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed. |
| 25 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and directed. |
| 26 | M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 27 | M&L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base complete all as specified and directed. |
| 28 | M&L forMachine pressed precast conrete interlocking paver block any shape and size with grey cement and pigment , glossy finish confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over sand cushion complete all as specified and directed.Note- Sand will be measured and paid separately. |
| 29 | M&L 25mm thick sand filling (sand cushioning) under path for laying interlocking pavers complete all as specified and directed. |
| 30 | M&L Granite 18 to 20 mm thick (black colour) work (table rubbed and polished) for wall lining(veenering to wall ) 12 mm thick in cement mortar (1:3 )and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 31 | M&L for glazed ceramic coloured tiles in vertical surface Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including backing coat of 10mm thick in CM (1:4) complete all as specified and as directed. |
| 32 | Demolition of RCC (reinforcement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams, staircases, landing,chajjas, parapet, lintel beam etc and similar suspended work complete all as specified and directed. |
| 33 | M&L for reinforced cement concrete nominal mix in type B-1 (1:2:4) (20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels and similar works complete all as specified and directed. |
| 34 | M&L for reinforced cement concrete nominal mix in type B-1 (1:2:4) (20 mm graded aggregate) Slabs supported on walls,columns,roofs, landings, balconies,canopies, deck slabs and in shelves and cover slab and the like complete all as specified and directed. |
| 35 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 36 | All as per item No 35 here in before but 6mm to 8mm dia complete all as specified and directed. |
| 37 | M&L for Formwork sides and soffits of beams, cantilevers, bressummers, lintels and similar works, fair finished of surfaces flat complete all as specified and directed. |
| 38 | M&L for Formwork to soffits of suspended slabs such as roof slabs, shelves etc fair finished of surfaces flat complete all as specified and directed. |
| 39 | M&L for Formwork to sides of pillars, posts, struts, piers, columns, fair finished of surfaces flat complete all as specified and directed. |
| 40 | Demolition Cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 41 | M&L 100 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, as in hardstanding, finished the surface even and smooth without using extra cement & including necessary form work, complete all as specified and directed. |
| 42 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A\" for thickness of concrete slab in 100mm complete all as specified and directed. |
| 43 | M&L for cement concrete type C2 1:3:6(20mm graded aggregate) as in coping , kneelers ,bed blocks and similar work complete all as specified and directed. |
| 44 | M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm and below stone aggregate ) in kerb stone factory made as approved by GE with plain fair faces including champhering, weathering etc complete with joint to match in CM 1:6 complete all as specified and directed. |
| 45 | M & L for concealed point wiring complete with PVC insulated /unsheathed strandedcopper conductor of wire 1.5 Sqmm , 1100volt grade FRLS , alongwith one single core ofsame size stranded copper as continuousearth wire to common earth dolly in andincluding PVC conduit pipe fitting medium grade suitable size fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall asrequired with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0mm thick laminated sheet where asrequired and accessories complete for the following :-(a) One light/fan point controlled by one on way switch complete all as specified and directed. |
| 46 | All as per item No 45 here in before but one socket outlet 05 Amps on the same board complete all as specified and directed. |
| 47 | All as per item No 45 here in before but one socket outlet 05 Amps on independent board complete all as specified and directed. |
| 48 | All as per item No 45 here in before but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket complete all as specified and directed. |
| 49 | S&FSwitch piano, single pole one way 5 Amps 240 volt capacity flush type complete all as specified and directed. |
| 50 | S&F 3 pin 5 Amps Socket outlet , flush type complete all as specified and directed. |
| 51 | S&F 5 pin, 5 Amps switch & socket combination flush type multipurpose3 pin, 5 Amp flush type universal complete all as specified and directed. |
| 52 | Supply and fix 3 pin 15 Amps switch socket combination, flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) complete all as specified and directed. |
| 53 | S&FSwitch piano, single pole one way 15 Amps 240 volt capacity flush type complete all as specified and directed. |
| 54 | S&F 6 pin 15 Amps Socket outlet, flush type complete all as specified and directed. |
| 55 | S& F ceiling rose with cover plate , 5 Amps surface type 240 volts bakelite three terminal complete all as specified and directed. |
| 56 | S&F 4 way sheet metal enclosures for flush/surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed. |
| 57 | S&F8 way sheet metal enclosures for flush/surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed. |
| 58 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB, DB complete with connection testing and commissioning.(a) SP 5 To 32 AMP complete all as specified and directed. |
| 59 | All as per item No 58 here in before but SPN 40 to 63 AMP complete all as specified and directed. |
| 60 | S & F of LED batten fitting alongwith removable LED Tube 20W, 230 Volt,wall /ceiling mounted ,LED battenfixed by means of bolts,ABS rotor suitable for single side connections. LED rod having glass material complete haivng lumen efficacy minimum 100 lm/w,CCT 6500 K, CRI>80 ,burning hour minimum 25000,PF - 0.9 powered by integral constant current driver suitable for 230 V AC with all accessories internallly prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 61 | Supply and fixing (BLDC) ceiling fans completeSupply and fixing ceiling fan completewith blades down rods ,with remote control unit with battery 02 Nos and accessories 230 Volt 1200 mm sweep min air delivery 240 cu m/min with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 62 | S & FLED post top(Smart G-3 type) with decorative circular design compiant to dark sky norms with polycarbonate opaldiffuser and IP 65/IK-10 protection installed withall fixing arrangement complete all as specified and directed. Make Philips BGP161 LED2300/WW PSU 220-240V 7043 or techno commercially equivalent as approved by GE. |
| 63 | Supply and fixing of 100 watt LED high highbay light fitting230 V, AC ,CCT 5700K with PDC hosing, integrated PC optics and 150 lm/watt efficency, 4 KV in built and 10 KV external surge protection with IP 66 ingress protection complete all as specified and directed. |
| 64 | Supply and fix Air circulator fans 230 volts single phase oscillating450 mm sweep almonaro industrial type suitable for wall mounting complete all as specified and as directed. |
| 65 | Supply and laying or fixing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (H/D) earthed cable aluminium conductor, 1100 volts grade with standed complete all as specified and directed for 10 sq. mm, 2 core nominal cross section in service connections complete all as specified and directed. |
| 66 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 67 | Supply and laying of DWC HDPE pipe of SN4 category conforming to IS 14930 part I and II including accessories like HDPE snap fit coupler with neaoprene \"O\" ring of 38 mm innner dia complete all as specified and directed. |
| 68 | M & L for boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as directed by Engineer-in- charge.Note:- Pipe for protection of cable shall be measured and paid separately. |
| 69 | S&FPVC wire 1.5 sqmm 3 Core PVC insulatedcable copper drawn through internally from looping box to street light fitting terminal incl all electrical connection complete all as specified and directed. |
| 70 | S&F looping box (enclosures) of size 300 x 250 x 150 mm made of PVC comprising of 02 Nosbus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6 Amp including MS bracket, nut an bolts complete all as specified and directed. |