Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-10-2025 |
| 2 | 17-10-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-10-2025 |
| Sl. No. | Item Description |
| 1 | Disconnectingelectric connection of Split/Window/cassette typeair conditioner ,watercooler/Deep freezer of any capacityfrom any height and taking down/ keep aside servicing the samecleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motoretc and necessary cutting, welding/soldering works with replacement of rusted bodywith new MS/GI Sheets of suitable size and making the appliencefullyfunctionaland re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: (i) .All the repairs shall be carried out at MES store yard including transportation of equipment shall be contractor\"s own arrangment.(ii) All newparts will be measured and paid as supply only under the respective item 2.00 to 5.00 listed herein below. |
| 2 | Supply only starting/running capacitor of 5 to 30 mfd capacity for compressor ofWindow/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 3 | Supply only starting/running capacitor of 30 to 80mfdcapacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 4 | Supply only starting/running capacitor upto 5mfd capacity for Fan motor ofWindow/Split Type Acs( 1.5 TR/2.0 TR) complete all as specified and directed. |
| 5 | Supply only remote hand set of window/split type air conditioner of capacity 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed. |
| 6 | Supply and fixing in repair temperature sensor for 1.5 TR / 2 TR window/split typeAC of any type complete all as specified and directed. |
| 7 | Supply and fixingin replacement Air Filtersuitable for Window/Split type Acs of1.5 TR/2.0 TR Capacitycomplete all as specified and directed. |
| 8 | Supply and fixing in repair brass suction/discharge valve of size 1/4 \",3/8\",1/2\", 5/8\"suitable for 1.5TR/2.0TRof split AC/window AC complete all as specified and directedd |
| 9 | Supply and fixing of drain pipe of3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed. |
| 10 | Supply and fixing in replacement compressor shut off valve of suitable size for window/split ACup to 2.00 TRcapacitycomplete all as specified and directed. |
| 11 | Supply and fixing of Swing motor suitable capacity for 1.5 TR / 2 TRwindow/split type ACs of any type/model complete all as specified and directed. |
| 12 | Supply and fixing in repairof copper tubing 1/4\", 1/2\",3/8\" diacomplete all as specified and directed. |
| 13 | M&L for detection and rectification of leakages in refrigerant line bynitrogen gas to find outleakage inwindow / split type AC(1.5/2.0TR),water cooler/Deep freezer/Refrigerator of any model/make and ensuring the complete systems leak proof flushing out nitrogen gas including charging/Topup of refrigerant gas R-134A / R 22/R-32 or any other refridgerant gas as requiredwith appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed. |
| 14 | S&F in repair ofPCB for indoor/Outdoor unit ofInverter Split ACs of any type of capacity 1.5/2.0 TR including removal of old PCB complete all as specified and directed. |
| 15 | S&F in repair ofPCB forwindow AC 1.5/2.0 TR Inveter ACs of any type and capacity including removal of old PCB complete all as specified and directed. |
| 16 | M&L for dismantling of defective PCB of window/Split AC of1.5/2.0 TR capacity of any make & type andrefixingafter repairing the PCB to ensure proper functioning of the AC complete all as specified and directed. |
| 17 | S&F in replacement Thermostat Switchas per exsisting size & model of Window/Split 1.5 TR/2.0 TR Capacityincluding taking out unserviceable Thermostat Switch from ACcomplete all as specified and as directed. |
| 18 | S&F in replacement of Thermostatsensor of AC (Window/Split Type) 1.5 /2.0 TRand removal ofunserviceable Thermostat sensor from AC complete all as specified and as directed. |
| 19 | M&L for removing burnt wiring kitof window /spilt type ACs, water cooler replace with best qualitynew wiring kit suitable type of PVC insulated copper conductor cable including thimbles sleeves of suitable size & shape complete all as specified and directed. |
| 20 | S&F in repairof PVC blower of SplitType AC 1.5/2.0 TR Capacity of approved Make and required Size to suit existing AC incuding removal of unserviceable blower complete all asspecified and as directed. |
| 21 | All as per item No 20.00 above but forwindow AC ( 1.5/2.0TR) |
| 22 | M&L for taking down of window/Split type AC of any capacity or model from any height/ any floor up to threestorey buildingand shifting to another locationin the sameor other building and refixing at New Location including testing of leakage and charging/top up of specified gasas per the make of the AC and make it fully functional again at new locationcomplete all as specified and directed. |
| 23 | S&F in repair of cooling coil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old cooling coil complete all as specified and directed. |
| 24 | All as per item No 23.00 above but forsplit AC ( 1.5/2.0TR) |
| 25 | M&L for dismantling of unserviceable/worn out reciprocating/hermetically sealed unit compressorfrom Deepfreezer/Refrigeratorand replacement with new one compressor, suitable for existing model/make including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134 A /R-32 or required type in appropriate qty after makingvaccum the complete systemand testingfor proper functioning complete all as specified and directed. |
| 26 | M&L in replacement of Strainer with Capillary tube/capillary tube of Window/ Split Type AC 1.5 /2.0TR Capacity including taking out unserviceableCapillary Tubefrom ACcomplete all as specified and as directed. |
| 27 | Supply and fixing ofPVC nylon imbraided pipe15 mm dia forcondensed waterdrain fitted on wallincluding all fittings complete all as specified and directed. |
| 28 | S&F in repair of foam insulation heavy duty for 1.5TR/2.0TR split ACs refrigerant line as per exsisting size complete all as specified and directed. |
| 29 | M&L for refrigerent gas charging (Top up)with required quantity of refrigerant R-22/R 32/R 407/R 410 or any other refrigerent as per the requirement in window & split ACs,water cooler,Deep freezer,Refrigerator of any capacity and make for its smooth functioning after carrying out vaccum and pressure test including necessary soldering/brazing to prevent leakage all as specified and directed. |
| 30 | Taking out defective condenser fan motor from window type AC of capacity 1.5/2.0 TRtransporting defective motor of any make &Type/ capacity from site at any height to contractor workshop dismantling the burnt winding & rewinding theblower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed. |
| 31 | All as per item No 30.00 above but for condenser fan motor of split AC (1.5/2.0TR) |
| 32 | All as per item No 30.00 above but for blower fan motor of split AC ( 1.5/2.0TR) |
| 33 | Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply & fixing new condensing unitcomplete with compressor,condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade complete all as specified and directed. |
| 34 | M&L in replacement of Starting Relay of AC(Window/Split Type) 1.0/1.5 TR/2.0TR Capacityincluding taking out unserviceable Relay from ACcomplete all as specified and as directed. |
| 35 | Taking down defectivecondenser fan motor of 1.5/2.0 TR Split AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all asspecified and as directed by Engineer-in-Charge. |
| 36 | Dismantling of defective indoor unit of 1.5 TR capacity split typeAC and supply & fixing new indoor unit of the same capacitywith blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required all as specified and directed. |
| 37 | S&F in repair of condensing coil complete with fins made of copper suitable for Windowtype AC (1.5/2.0 TR) as per existing model/size including removing of old condencing coilcomplete all as specified and directed. |
| 38 | All as per item No 37.00 above but forsplit AC ( 1.5/2.0TR) |
| 39 | S&F in repair of stand mounting bracket (heavy duty)for split AC (1.5/2.0TR) made of 2mm thick high steel power coating for rust prevention suitable for wall/floor mountedout door AC unit,including fixing with suitablefastenerson exsisting location/building (upto three storey) complete allas specified and as directed. |
| 40 | Taking down defectivecondenser fan motorof 1.5/2.0 TR window AC andS&F new condenser fan motor as per exsisting make/model with copper winding complete all asspecified and as directed by Engineer-in-Charge. |
| 41 | Taking down defectivecondenser fanblade of 1.5/2.0 TR window/split AC andS&F new condenser fanblade as per exsisting make/model with copper winding complete all asspecified and as directed. |
| 42 | S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB of\"C\" series of capacity 20 Ampincluding taking out the old one complete all as specified and directed. |
| 43 | M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Voltsincluding taking down old one complete all as specified and directed. |
| 44 | Supply and fixingin repair MCB SP 16-32Amps rating of \"C\" seriesto be housed in industrial socket complete all as specified and directed. |
| 45 | S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with 2 x single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4 Sqmmas current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one complete all as specified and directed.Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit. |
| 46 | M&L Metal clad Industrial socketISI mark with earth 250 Voltsincluding taking down old one complete all as specified and directed. |
| 47 | M&L for dismantling of unserviceable/worn out hermetically sealed unit compressorfrom windowACand replacement with new one compressor, suitable for existing model/make of capacity 1.5/2 TRwindow type AC including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134 A /R 22 /R-32 in appropriate qty after makingvaccum the complete systemand testing the AC for proper functioning complete all as specified and directed. |
| 48 | All as per item No 47.00 above but forsplit AC ( 1.5/2.0TR) |
| 49 | S & Fofplywood 12 mm thick prelaminated,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished fixing in small pieces around window AC to make air tighton wall/window including necessary carpenter work complete all as specified and directed. |
| 50 | S&F of reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed. |
| 51 | S&F of 05 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% completeand taking out old unserviceable stabilizer complete all as specified and directed. |
| 52 | S&F in repair of PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed. |
| 53 | S&F in repair of power transfromers suitable for voltage stablizers of capacity 4/5 KVAcomplete all as specified and directed |
| 54 | M&L for removing the desert cooler from its existing position at any height from stand or pillar, removing the side panels, taking out unsv wood wool pads or loose pads including supporting jali(HDPE plastic /steel wire mesh)and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in positionincluding oiling and greasing of fan kit, water pump motor, refixing wood wool pad secured with new HDPE soft mesh complete all as specified and directed. |
| 55 | Taking down of unserviceabledetachable type perforated side panel from exsisting desert coller S&F new perforated side panel made out 22 gauge PGI sheetsuitable for desert cooler over all size of 0.750x0.750x0.910 mtrcomplete all as specified and directed. |
| 56 | S&F in replacement of unserviceable wood wool pads with supreme quality white wood wool (set of three) in repair includingPVCpipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of desert coolers of complete all as specified and directed. |
| 57 | Supply and fixing in replacement of supreme quality white wood woolin loose suitable for industrial desert coolercomplete all as specified and directed. |
| 58 | S&F in replacement of unserviceable honeycomb wooden wool pads with supreme quality honeycomb pad (set of three) in repair includingPVCpipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of existing coolers(Plastic body)complete all as specified and directed. |
| 59 | Taking out defectiveexhaust fan of 16\"/18\"of any make from desert/industrial coolerand transporting it tocontactor\"s workshop, opening of fan motor , taking out rotor, cutting out the burnt winding ,cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed. |
| 60 | Taking out defective desert cooler fan ofcapacity upto 300watt, 1500rpm capacity from desert coolerrewinding of the same with the existing size of super enameled copper winding including varnishing, greasing, painting reassembling testing and fixing in positioncomplete all as specified and directed. |
| 61 | S&F in repair of switch piano flush button single pole one way 15 Amp, 240 Volts in desert cooler conforming to IS 3854 ISI marked. |
| 62 | Taking downunserviceableexhaust fan (heavy duty) of 16\"/18\"sweep size,2800 rpm from desert cooler, supply and fixing newexhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. |
| 63 | Taking downunserviceableexhaust fan of Plastic desert coooler of existing type(Symphony silenzo 120i model), supply and fixing newexhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, side arms and rubber pads etc including testing complete all as specified and directed. |
| 64 | Supply and laying orfixing or passingtwo core 4 sqmm stranded conductor throughpipe, 1100voltsgrade heavydutycablewith PVCinsulated aluminiumconductor served with aninner sheathing of PVC tapearmouredwith galvanisedsteel wire or tapeandoverallPVC sheathed and taking out old unseriviceable wire complete all as specified and directed. |
| 65 | S&F in repair of Polycarbonate Plug top 3 pin 6 Ampcomplete all as specified and directed. |
| 66 | S&F in repair of Polycarbonate Plug top 3 pin 16 Ampcomplete all as specified and directed. |
| 67 | Supply and fixing in renewal of desert cooler submersible pump having power of 18/20W,and out put 1200 Ltr/hr single phase 230 Volt AC, (ISI marked) suitable for evaporating type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed |
| 68 | Supply and fixing in renewal of desert coolersubmersible pumphaving power of 40W &3500 Ltr/Hr output, single phase 230 Volt AC, (ISI marked)suitable for Industrial type cooler including fixing clamp inside the Industrial type cooler complete all as specified and directed |
| 69 | Taking down unserviceable exhaust fan frame S&F and fan frame and supporting Leg for exhaust fan including nut, bolts, washer Rubber, clamp etc complete Set complete all as specified and directed. |
| 70 | S&F in repairof capacitor upto 4.5 Mfd for desert cooler fancomplete all as specified and directed. |
| 71 | S&F of plywood 6mm thick, cut to shape as required on site fixing aroundwall/ window/ cooler opening with and including necessary nuts & bolts/ screws complete all as specified and directed. |
| 72 | Supply and fixing in repair ofsteel multi wing exhaust fan blade set of best quality as per existing type and size of16\"/18\" sweep heavy duty for desert cooler complete all as specified and directed. |
| 73 | Taking down unserviceable fresh air fan motor (Fan kit) from desert cooler and supply and fixing new fresh air fan kit of copper winding (150-300Watt),1500 RPM,230 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed. |
| 74 | Supply and fixing in replacementof evaporator coil ISI marked suitable for water cooler of any make/type/ capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F in repairof starting/running capacitor upto 30Mfd for blower motor of water coolerhaving capacityof 40/80 & 60/120 ltrcomplete all as specified and directed. |
| 76 | S&F in repair of starting/ over load Relay for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable relay complete all as specified and directed. |
| 77 | M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site andreplace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximately0.750x0.750x0.230 mtr and front grillmade out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction,03 Nos perforated sheet side panels size Approximate 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed. |
| 78 | Taking out the unserviceable sealed compressor unit from water cooler andS&F New Sealed compressor unit of existing sample, suitablefor 40/80 Ltr &60/120 Ltr capacity of water cooler replace with newcompressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 ain appropriate quantity and testing for smooth functioning complete all as specified and directed. |
| 79 | Taking out defectivewater cooler blower motor any make/size fromcooler upto 60/120 ltr capacity , cutting out the burnt winding cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire includinggreasing, reassemblingcomplete all as specified and directed. |
| 80 | S&F in replacement of steel body desert cooler fan regulator of existing type and size including removing old regulatorcomplete all as specified and directed. |
| 81 | S&F in repair of thermostat switch /relay suitalbe for water cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable onecomplete all as specified and directed. |
| 82 | S&F in repair of condenser coil(copper tubing) for Water Cooler having capacity 40/80 and 60/120 Litres ofany make including removing unserviceable condenser coil complete all as specified and directed. |
| 83 | Taking out the burnout blower motor from water cooler andS&F New single phaseblower motor (copper winding) of existing sample/size suitablefor 40/80 Ltr & 60/120 Ltr capacity of water cooler complete all as specified |
| 84 | S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. |
| 85 | S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 86 | Material and labour for disconnecting electric connection, taking down/ keep aside the outdoor unit of VRF type AC having power supply upto 10 KW including stabilizer of any make and capacity,servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gaskit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and directed. |
| 87 | Taking down ceilling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding,servicing, painting of fans and refixing the same position or complete all as specified anddirected. |
| 88 | Cleaning, washing, greasing, oiling and varnishing of ceiling fan/exhaust fan/air circulator fan of any size and make complete all as specified and directed. |
| 89 | M&L for opening and rewinding with super enamelled copper winding wire of existing size of ceiling fan 1200/1400 mm sweep complete all asspecified and directed. Note : Cost of transportaion from site to workshop in deemed to be includedin quoted rates. |
| 90 | All as per ser item No 89.00 here-in-before but for exhaust fans/wall mounted fan of any size (200mm/250mm/450 mm) sweep. |
| 91 | M&L for replacement of defective ball bearing for ceilling fan of 1200/1400 mm sweep size (Bearing make/size SKF-6201/6202/ or equivalent) complete all as specified and directed. |
| 92 | M&L for replacement of defective capacitor of size 2.5/3.5 mfd for any type of fans suitable for 250 V including making connection complete all as specified and directed. |
| 93 | M&L for replacement of flexible copper conductor cable 3 core PVC insulated & PVC sheathed 1100 Volts grade size of cable 23/0.0076 complete all as specified and directed. |
| 94 | M&L for painting of ceilling fans any make of size upto 1400 mm at site with one coat of superior quality synthetic enamelled spray paint of approved make by spraying, filling cavities with filler after preparation of surface and wirting letter as per existing such as (MES AC12345) with black systhetic enameled paint 1\" high on both sides of fans all as specified and directed. |
| 95 | S&Fin repair of Metal ExhaustfanAC single phase 230 voltof size 380 mm sweep,with minimum 1300 RPMwith louvers and shutter connecting up including provision of cable from ceiling rose complete all as specified and directed. |
| 96 | S&Fin repair of Metal Exhaust fan AC single phase 230 voltof size 450 mm sweepwith minimum 2400 RPM heavy dutywith louvers and shutter connecting up including provision of cable from ceiling rose etc complete all as specified and directed. |
| 97 | S&Fin repair of wall mountedfans 230 volts with minimum 1300 RPMsingle phase oscillating 250 mm sweep suitable for wall mounting complete all as specified and directed. |
| 98 | S&Fin repair of PVC ventilation fan, working on single phase, 230 Volts, 50 Hz of sweep 200 mm with louverswith minimum 1300 RPM complete including fixing arrangement, grouting of Bolts in wall etc all as specified and directed.Note :- For the item 97.00 to 98.00 : Old unservicealbe fans shall be deposited in MES store yard. |
| 99 | Takingdownexisting unserviceable/old point wiring concealed/surfaceincludingfitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches butexcluding PVC conduit etc complete all as specified and directed |
| 100 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of suitable thickness including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 101 | One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch. |
| 102 | One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. |
| 103 | One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. |
| 104 | One light point controlled by two 2-way switches |
| 105 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed .NOTE: PVC conduit, Pressed steel Sunk box and phenolic laminated sheet if required ,measured and paid seperatly. |
| 106 | One light/fan/exhaust fan/call bell point controlled by 1 No,one way 5/6 Amp switch. |
| 107 | One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. |
| 108 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 109 | Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . |
| 110 | S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked . |
| 111 | S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked. |
| 112 | S&Ffor socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked including. |
| 113 | S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one. |
| 114 | S & Fceiling rose, surface Bakelite,isolated bodythree terminals including taking down old one. complete all asdirected. |
| 115 | S&F Electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetincluding taking down old one and connecting complete all as specified and directed. |
| 116 | S& F forcast iron /pressed steel terminalrectangular box 60mm deep of following size for mounting switches,sockets ,regulator etc. with 3mm thick plastic laminated sheet cover of size rectangular complete including taking down old one. |
| 117 | All as per item No. 112.00 here in before but for size 150x75mm |
| 118 | All as per item No. 112.00 here in before but for size 150x150mm |
| 119 | All as per item No. 112.00 here in before but for size 200x150mm |
| 120 | All as per item No. 112.00 here in before but for size 200x250mm |
| 121 | S&F rigid medium PVC conduit of 25 mm dia exclusive of boxes out inclusive of all tees, bends, elbows, reducers, bell mouth tubes and fixing accessories such as coulers locknuts, saddles, pipe hooks of size including cutting of shape and flushed in wall where requiired and repairs. |
| 122 | S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old oneNote: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit. |
| 123 | Supply & fix ventilation fan, working on single phase, 230 Volts, 50 Hz of sweep 200 mm with louverswith minimum 1300 RPM complete including fixing arrangement including grouting of Bolts in wall etc all as specified and as directed.Note:- Unserviceable fan deposited in MES store. |
| 124 | S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directedincluding taking down old one. |
| 125 | S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of \"\"B\"\" series with required wiring connections and lugs etcincluding taking down old one complete all as directed. |
| 126 | S&F MCB’s single pole and neutal,32 Amp to 40 Amp 240 Volts,and of \"\"B\"\" series with required wiring connections and lugs etcincluding taking down old one complete all as directed. |
| 127 | S & F Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient,18 watt,50 Hz including taking down the old fitting |
| 128 | S & F bulkhead light 10 watt suitable for outdoor application including taking down the old fitting. |
| 129 | M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directedNote - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items. |
| 130 | S & F decorative, wall mounting, champagne gold finish fixture with plastic body suitable and including9 W LED lamp B22 base complete including taking down the old holder complete all as directed by engg in charge. |
| 131 | S & F in repair LED bulb 9 W complete all as directed. |
| 132 | S & F Decorative ultra slim round profile 2 feet LED lighting fixture ,10 W ,with extruded polycarbonate, environmental friendly, energy efficient including taking down the old fitting |
| 133 | S & F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten complete all as directed. |
| 134 | S&F in repair modular switch single pole one module 6 Amp |
| 135 | S&F in repair modular socket single pole two module 6 Amp |
| 136 | S&F in repair modular switch single pole one module 15/16 Amp |
| 137 | S&F in repair modular socket single pole two module 15/16 Amp |
| 138 | S & F in repair modular white cover plate with frame 4 module complete all as directed by engg in charge. |
| 139 | S & F in repair modular white cover plate with frame 6 module complete all as directed by engg in charge. |
| 140 | S & F in repair modular white cover plate with frame 8 module complete all as directed by engg in charge. |
| 141 | S & F in repair switch socket combination 2 in 1 , 5 & 15 amps complete all as specified and directed all as directed by engg in charge. |
| 142 | S & F TPN DBs DPX3 MCCB DBs suitable for DPX3 MCCB 160 Amps as incomer and 24 Nos MCB SP as outgoing 415 Vol,50Hz 8 way including taking down the old one complete all as specified and directed. |
| 143 | S & F MCCB TPN 160 Amp 415 V ,25 KA ,thermal magnetic type ,suitable for ICU between 80%-100%. Including connectionwith copper lugs including taking down old one complete all as directed. |
| 144 | Supply and fix in repair of 1.5 Sq mm FR LSH PVC insulatedSingle core multi strand copper wire complete all as specified and directed. |
| 145 | Supply and fix in repair of 2.5 Sq mm FRLS PVC insulatedSingle core multi strand copper wire complete all as specified and directed. |
| 146 | Supply and fix in repair of 4.0 Sq mm FRLS PVC insulatedSingle core multi strand copper wire complete all as specified and directed. |
| 147 | Supply and fix in repair of 6.0 Sq mm FRLS PVC insulatedSingle core multi strand copper wire complete all as specified and directed. |
| 148 | Supply and fixnylone sleeve, SIZE 50MM complete all as specified and directed. |
| 149 | Supply and fixnylone sleeve, SIZE 38MM complete all as specified and directed. |
| 150 | Supply and fixgypsum screw, size 50mm complete all as specified and directed. |
| 151 | Supply and fix gypsum screw, size 38mm complete all as specified and directed. |
| 152 | Supply and fix5 -in-1, 6 Amp,240V,SS Combined unit with box (surface type) with two fixing holes incl fixing rawal plug & screws complete all as specified and directed. |
| 153 | Supply and fix5 -in-1, 6/16 Amp,240V,SS Combined unit with box (surface type) with four fixing holes incl fixing rawal plug & screws complete all as specified and directed. |
| 154 | S&F in replacement of PVC connection pipe, 600 mm long with brass Nutwith rubber washer suitable for hot/cold water complete all as specified and directed. |
| 155 | S&F in replacement of Plug Top 15 Ampscomplete all as specified and as directed. |
| 156 | Supply and fix in repair heating element 1500 watts capacity in round/ triangularshape bottom(Cup shape ) with rubber gasket and fixing to existing geyser complete all as specified and directed. |
| 157 | Supply and fix in repairbrass geyser inlet/outlet assembly suitable for 25 Ltr capacity gyser including nuts, washers, check nuts and all connected items, complete all as specified and directed. |
| 158 | Supply and fix in replacementthermostat suitable for adjusting the temperature from 0 degree centigrade to 80 degree centigrade for 25/50 Ltr geyser including LED indicator lampcomplete |
| 159 | Supply and fix in repair copper innertank suitable for geyser ofcapacity 25 ltrwith 6/9 numbers of holes all as specified and directed. |
| 160 | Syupply and fix in repaircover outer complete including top and bottom suitable for 25 Ltr capacity gyser of any make, shape and size as per existing but gauge of sheet not less than 22 SWG all as specified and directed. |
| 161 | S & F heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer 02 Nos on each endsfor Hot waterincluding taking out the old one complete all as specified and directed. |
| 162 | S & F heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer completefor Cold water completeincluding taking out the old one all as specified and directed. |
| 163 | M&L painting of complete outer body of storage type geyser of capacity 25 to 50 litreswith two coat of synthetic enameled paint including preparing surfaceand including writing of MES No with black paint complete all as specified. |
| 164 | M&L GI tubing 15 mm dia medium gradeISI Marked, laid in trench/floor or fixed on wall with all fixingaccessories etc all as required and directed. |
| 165 | Supply and replacement of Rubber Gasket flange as per site requirement for 25/50 ltr geyserincluding taking out the old one |
| 166 | S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of 15 mm dia including taking out old UNSV all as specified and as directed. |