| 1 | Supply, fixing, installation, commissioning and testing of three star rated inverter type hi wall mounted split AC unit of rated capacity 1.5 TR invertor based hot and coldtype indoor and out door unit completeset with having both cooling and heating function and digital inverter type complete with cordless remote control and full filling of initial refrigerant gas along with having in built heating and cooling arrangement and invertor rotary comprwssore unitand suitable for operation for 230 Volt 50Hz single phase electric supply including providing of MS stand & bracket for fixing of outdoor unit and indoor unit system and also providing of both type/size of suction and discharge copper refrigerant piping attachment system and duly fixed both piping connected for outdoor unit to indoor unit system along with duly over lapped it by nitrile insulation, with insulation taping work and also providing of suitable size of drain pipe line system up to ground level for dropping out the condensing water outside area from evaporator unit attachement system and making electric connection with 3 core copper cable of suitable size and including making of hole on existing typewall/roof/ceiling etc and after making good to all disturbed surface match to existing wall, complete all as specified and directed. |
| 2 | Supply, fixing,installation,commissioning and testing of wall mounting hanging based automatic operation based digital type voltage stabilizer unit of rated capacity 5 KVA complete and suitable using for single phase naturally air cooled indoor type with having digital display and suitable for operation on single phase AC supply and with having designed voltage for input & output voltage up to 130 Volt to 230 Volt with accuracy + 2.5% and having low and high voltage cut low voltage cut off130 (-) 5 volts high voltage cut off 230 V (+ 5) Volts along with start time delay system with time delay adjustable upto 30 second to 1.5 minutes system unit, complete all as specified and directed. |
| 3 | Supply and fixing of sheet metal enclosure duly powder coated with single pole and neutral enclosure with having a two pin and earth plug & top and mounting channel alongwith one 01 MCB SP 20/32 Amp and dully fixed surface on wall or concealed in wall and making all necessary electrical connection complete all as specified and directed. |
| 4 | Supply and fixing of sub main wiring system with PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size single core 2 run of 4 Sqmm and 1 run of 4 Sqmm FRLS wire (Nominal area) and drawn through in heavy duty PVC casing capping/ PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed in wall or surface on wall all as per decision and direction by EIC including and making electrical connection of complete system all as specified and directed.Note:- 3 runs of 4 sqmm wire and one run of PVC caseing/ capping/ conduit shall be measured as 1.00 running meter . |
| 5 | Supply and fixing of distribution board boxdouble door based type of rating SPN 4/6 way type 220 volt AC supply system and made out of sheet metal enclosure with duly powder coated & framing work with locking system and having double door type arrangement system and with having neutral and earth link bus bar and mounting base channel suitable for holding MCBs incomer and outgoing system complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical complete all as specified and directed. |
| 6 | S&F MCB SPN63 Amps, 230 Volts, 50 Hz AC supply suitable for \"C\" series, 10 KA breaking capacity, complete all as specified and directed. |
| 7 | S&F MCB SP 20 to 32 Amps, 240 Volts, 50 Hz AC supply suitable for \"C\" series, 10 KA breaking capacity, complete all as specified and directed. |
| 8 | Supply, fixing & jointing of AC copper tubing/piping line and suitable using it for both refrigerant gas line attachment for suction/discharge piping system complete along with providing of insulating material over the both refrigerant gas pipe line attachment system and including fixing supports/ saddles etc as required at site, complete all as specified and directed. |
| 9 | Supply and fixing of sub main wiring system with PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size single core 2 run of 16 Sqmm and 1 run of 16 Sqmm FRLS wire (Nominal area) and drawn through in heavy duty PVC casing capping/ PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed in wall or surface on wall all as per decision and direction by EIC including and making electrical connection of complete system, complete all as specified and directed.Note:- 3 runs of 16 sqmm wire and one run of PVC caseing/ capping/ conduit shall be measured as 1.00 running meter . |
| 10 | Supply, fixing, installation, commissioning and testing Mortuary cabinet chember ISI mark of capacity for 04 body based storage type with having maximam length of inside space upto 7.5 feet long system unit complete. Mortuary cabinet chember complete body made out of stainless steel framing based type and suitable for single phase, 230 V, 50 Hz, with 0.55 mm thick exterior & interior finish pre painted GI sheet, 0.5 mm thick front finish in stainless, including vapour proof incandescent lamp, electric temperature indicator cum controller, 3 phase carriage assembly, one piece stainless steel tray, inbuilt power panel etc. suitable for unitary type refrigeration system and temperature range of 4-6ºC complete all as per decision and direction by EIC and includingmaking electrical connection of complete system, complete all as specified and directed.Note:-(a) If any miscellenous ,minor specification of items and other quantity of minor items which are/is not mentioned / covered under this item/schedule but required for the Mortuary cabinet chember machine for installation / testing commissioning purposed it shall be provided by the contractor as per OEM specificatios/ recommendations and the cost of the same shall be deemed to include in the quoted rates.(b)Before installation of above equipment/plants machine unit , the contractor to be produce the OEM manufacture test certificate and purchase voucher and to be submit to GE / Engineer In Charge for their further direction and necessary action.(c) The rate quoted by the contractor ontender for the work deemed to included the if required for necessity like PCC/RCC/MS base frame foundation work for installation ofMortuary cabinet chember etc and other equipments as per specified by OEM. |