Tender For Construction Of Toilet At Kuchipatti Pups In Krishnarayapuram Town Panchayat, Karur District.; 1 Earth Work Excavation for foundation in all types of soils and sub soils to full depth (such as Soils in Rock / Silt / Light Black Cotton Soil / Ordinary Soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the Departmental Officers with initial lead of 10 m and initial lift of 2 m. Complete as per TNSS23 & 24, V, VI (S2), VII, 9,10 2 Plain Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. 3 Supplying andErrectingsteel centering including necessary supportsfor plain surfaces for Reinforced Cement Concrete works such as Coloumn footing,Coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorsComplying with standard Specification without Strutting. ( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII 4 Below Ground Level 5 Ground Floor 6 Column 7 Supplying andFabricatingandplacinginpositionmildsteelofribbedforsteelbarsforallR.C.C.worksincludingbending,cranking bindingetc.,includingcostofbindingwireM.S.chairslapstofixthereinforcementinallpositionalllasourandmaterialsetc.CompletecomplyingwithstandardSpecification. 8 R.C.C.1 : 11/2 : 3 (One Cement One and Half Sand Three Aggregates) using 20mm gauge hard Granite broken stone jellyincluding cost curing, etc., complete as per standard specification and as directed by Engineer incharge. 9 Below Ground Level 10 Ground Floor 11 Supplying and FillingofU/S Gravelfromapprovedquarry in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of material to site and all labour charges and all other incidential charges etc., complete as per Standard Specification. 12 Brickwork in Cement Mortor 1:5 (One Cement and five Sand)usingbest quality of Flyash Bricksof size 83/4x41/4x21/4 includingall costof materialsand Labour Charges including Curing charges etc., Complete as per standard specification. 13 Below Ground Level 14 Ground Floor 15 Special CeilingPlasteringinC.M. 1 : 3 (One Cement, Three Sand) to10 mmthickincludingallcostandconveyance ofallmaterialstositeincludingcostofcementwhichwillbepurcharedlocallybythe contractor andconveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 16 PlasteringinC.M. 1 : 5to (One Cement, Five Sand) 12 mmthickincludingallcostandconveyanceofallmaterials tositeincludingcostofcementwhichwillbepurcharedlocallybythecontractor and conveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 17 PlasteringinC.M. 1 : 5to (One Cement, Five Sand) 20 mmthickincludingallcostandconveyanceofallmaterials tositeincludingcostofcementwhichwillbepurcharedlocallybythecontractor and conveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 18 Supply and Fixing in Position of Terracotta Jally including errecting centeringfor Sides and Soffitsandconveyance of all material to site and all other labour charges for fixing etc., Complete. 19 Finishing the Floor with Ceramic Tiles of size 305 x 305 x 6 mm of approved quality as Instructed by the Engineer incharge and set in Cement mortor 1:3 (1 of cement 3 of sand) 20mm thick using river sand including all cost of labour and all costofmaterialsetcCompletecomplyingwith standardSpecifications. 20 Dadooing Walls with Following Best Approved Quality, White / Colour Glazed Tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 21 SupplyandFixingof Bison panel Door 16mm thick including allLabourCharges for wroughtandPut upinpositionandalsofixinghold fastsinframesandmasonryetc., Complete Complying with StandardSpecifications. 22 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting etc., 23 Supply and Fixing of 25mm thick Precast Slab including cost and conveyance of all materials and all labour charges etc, 24 Wiringwith2 x 1.5 Sq.mm (22/0.3)PVCinsulatedSC Unsheathed Cu. Conductor of 1100V grade in cuitable PVC rigidpipe concealed in wall and CeilingwithPVCaccessoires in flushwith wall with 3mm thick Hylum Sheet cover with TW Switch box and 5A F.T. Switch and making good of the Concealed portion with suitable colour for PVC CONCEALED LIGHTPOINT/FAN POINT (for Electronics Regulator) (SD NO: 25) 25 TowardsCostandSupplyofLED LightFittingsincludingallcostand conveyancetositeetccomplete. 26 Supply and Fixing ofFollowingPVC and GI Pipes and Specials of good quality includingcost of materials and labour with cost for coveyence to site etcCompletecomplyingwith standardSpecifications. etc., 27 110mm PVC Pipe 28 110mm PVC Elbow 29 110mm PVC Tee 30 32mm PVC Pipe 31 32mm PVC Coupling 32 32mm PVC Elbow 33 32mm PVC Bend 34 32mm PVC Tee 35 32mm GM Gate Value 36 20mm GI Pipe B Class 37 HDPE Tank 1000 Ltr ISI/ISO 38 32mm PVC Nipple 150mm 39 32mm x 15mm PVC Reducer 40 15mm GI Tap 41 40mm PVC Pipe 42 Supplying and Painting thewalls with TwoCoatsColour Cement Paint over one coat of cement primer as instructed by the departmrntal officers includingPreparation of surface curing, etc complete in all floorscomplying with standard specification. ( The Colour and shade of the paint shall be got approved by the departmental officers.) 43 Painting New Iron Works such as Steel Doors, Windows, Ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)