Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #51443737

Tender For Provision Of Civil And Electrical Works Including Geyser Installation Chemical Earthing Air Circulators Sign Board Road Furniture Sunshades Interlocking Tiles Water Tanks Rcc Benches Building Alteration Atration And Associated Infrastructu

Issued by Statutory Bodies & Commissions/Committees · gwalior, Madhya Pradesh
Tender Value
24.93 Lakhs
Estimated cost
Bid Submission
28 Oct 2025
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Provision Of Civil And Electrical Works Including Geyser Installation Chemical Earthing Air Circulators Sign Board Road Furniture Sunshades Interlocking Tiles Water Tanks Rcc Benches Building Alteration Atration And Associated Infrastructure At Adrde

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Oct-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-Oct-2025
2 23-Oct-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-Oct-2025

BOQ

NAME OF WORK :PROVISION OF CIVIL AND ELECTRICAL WORKS INCLUDING GEYSER INSTALLATION, CHEMICAL EARTHING, AIR CIRCULATORS, SIGN BOARD, ROAD FURNITURE, SUNSHADES, INTERLOCKING TILES, WATER TANKS, RCC BENCHES, BUILDING ALTERATION/ATRATION AND ASSOCIATED INFRASTRUCTURE AT ADRDE AGRA AND DRDE GWALIOR UNDER GE(I) R&D DELHIAtration
Sl. No. Item Description
1M&L for hard core of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a ture surface complete all as specified and directed.
2Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
3S&F Glow sign board of size4.50 M X 0.75 M X0.20M with acrylic sheet 4 mm thick, on front, LHS & RHS andaluminium composite panel board on rear side ,with letters \" Raksha Vihar Residential complex , Ministry of Defence , Govt of India \" (English and Hindi words) along with DRDE embellam including LED back lights ,fixed on existing MS posts. complete all as specified and directed.
4Dismantling mild steel and structural work including grills, guard bars, doors and gates etc complete all as specified and directed.
5Dismantling plain or corrugated steel sheeting (any gauge, thickness) in roof coverings complete all as specified and directed.
6Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, framed and hung as gates, including pintle hinges, stops hand made sliding bolts etc., ladders framed balusters walk ways railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
7Preparing new steel or iron surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
8M&L for Fibre glass reinforced translucent corrugated sheeting with fixed with L-type or J-type or cranked hook bolts in lieu of screwtwo corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
9Sign boards including warning, prohibitory, mandatory and Informative road signs of requisite size made with 2mm thick aluminium composite panel comprising high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends, borders, letters/numerals etc) as directed with high intensity prismatic grade retro reflective sheeting complete including fixing over stainless steel frame work (Measured gross out of which the shape is cut) complete all as specified and directed.
10Providing stainless steel section including fabrication, weldingas per requirment ofSS-304 grade for frame work of sign boards etc of size and shape as directed including excavation post holes n.exc 0.50cum and embedded of pole in PCC 1:2:4 complete.
11Surface Excavation n.exc 30 cm deep and avg 15 cm deep and getting out in any type of soil complete all as specified and directed.
12Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
13Providing precast Plain cement concrete Type B1 1:2:4(using 20mm aggregate)in Kerb stone ,window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings.kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in Cement mortar 1:4complete with joints to match complete all as specified and directed.
14S & F of 2000 litresRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old tank all as specified and directed
15S&F20mm Globe valve (PPR Ball Valve) with iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
16S&F 20mm bore galvanised steel water tubing medium grade with all fittings complete fixed to wall and ceiling or laid in floors complete all as specified and directed.
17S&F Ball valvesof diameter 20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
18M & L for Cement concret of type B1, 1:2:4 of (20 mm aggregate) in platform for watertank , lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
19S & F of Precast RCC bencheswith Back rest and without arms of overall size 1.5m x 0.6m x 1.0 m height & specifications are as follows :-(a) SEATS : (i) 02 in no Planks of Size 1.50m in length, 100mm in Width and 50mm thick. (ii) 01 in no Planks of Size 1.50m in length, 210mm in Width and 50mm thick(b) BACK REST : (i) 03 in no Planks of Size 1.50m in length, 100mm in Width and 50mm thick. (c) LEGS : (i) 02 in no Planks of Size 0.6m in width, 1.0m in height and 100mm thick, Including two coats of plastic emulsion over a coat of primer complete all as specified and as directed by Engineer In Charge
20Taking down Aluminium chowkats or framesexc 1.5 sqm but n. exc 4 Sqm each with shutter(without taking off shutter from the frame) complete all as specified and directed.
21S&F Framelesstoughened glass doorwith sliding shutters(02 Nos)shutter 12MM thick ,factory toughened plain sheet glass , not exc 2.00SQM,using thestainless steel fittings of polished chrome finish ,in each shutter (satin stainless steel finish for handles) including cutting necessary holes and cutouts complete all as specified and as directed by Engr-in-charge. (a) corner lock patches with EPC nad strike plateXL-C-4011A:01 No(for openable shutter) (b)Floor spring 90o open(EN4)01 No(for openable shutter) (c ) Top patches XL-C 4012: 01 No (for openable shutter)(d) Bottom patches XL-C 4013: 01 No (for openable shutter)(e) Top pivots XL-C 4014: 01 No (for openable shutter) (f)450mm long H -Type handles 25mm dia of grade SS-304,XL-C-3003A: 01 No (01 Set for openable shutter)
22S & F in repairs of Mortice lock vertical type size 100mmof Brass 4 lever complete all as specified and directed.
23Eacavating in trenches n exc 1.5m in wdith & n exc 1.5m in depth for foundation manholes, cenpits, pier holes etc. and getting out in soft/loose soil complete all as specified and directed.
24Eacavating in trenches n exc 1.5m in wdithexc 1.5m but not exc 3m in depth for foundation manholes, cenpits, pier holes etc and getting out in soft/loose soil
25Returning, filling including spreading, levelling, watering and well ramming in layers n exc 25cm in soil.
26Providing cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate bed to drain pipe 150mm dia including packing under and hunching against the pipe after they are laid complete all as specified and directed.
27M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 using old size bricks complete all as specified and directed.
28M&L for 150mm bore salt glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed.
29Providing cement concrete type D2 1:4:8 (40mm graded aggregates) as in foundation filling and mass concrete complete all as specified and directed.
30M&L for rendering 15mm thick on brick or concrete surfaces in CM 1:4 finishing even and fair without using extra cement complete all as specified and directed.
31Providing reinforced cement concrete 1:2:4, type B1, using 20mm graded stone aggregated in cover slab for manholes, septic tanks, drains etc complete all as specified and directed.
32Providing 6 to 8 mm dia TMT reinforcement bars Gd.I, IS- 432 (Part I), cut to length, bent to shape required, cranking and binding with mild steel (annealed) wire not less than 0. 9mm dia complete all as specified and directed.
33Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
34Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, hard/dense soil
35Providing cement concrete type C21:3:6 (40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
36M&L broken stone or bouldershardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
37Providing 75mm thick cement concrete type 1:4:8, D-2 (40mm graded aggregate) in sub base of floor complete all as specified and directed.
38S&F Rolled mild steel sections (Fe-290 Gde E-165) as in main and cross beams, hip and jack rafters; columns, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
39S & F plain or chequered plates (Fe-290 Gde E-165) square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
40S&F Steel work in square or rectangular tubular purlinscomplete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed.
41S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
42Preparing new steel or iron surfaces over 10 cm in width or girth and two coats of black bitumenous paint over a coat of red oxide primer.
43Providing and laying factory made M-25 grade cement concrete kerb stone fixed in position to the required line, level and curvature including necessary earthwork, jointed with cement mortar 1:3, making joints with or without grooves, thickness of joints not more than 5 mm (except at sharp curves).
44Rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick walls, finished even and smooth without using extra cement including taking down of cement plaster on brick or stone walls, etc. including raking out joints, hacking for key,crubbing down with water, etc.
45Supply and Fixing Water heater storage type, electric, capacity 25 litres. BEE 5 star rated including two Nos Hot and cold water connection pipe complete all as specified and directed
46Matenal & labour for point wiring complete with FRLS, PVC insulated unsheathed cable, 1100 volts grade confirming to IS-694, ISI marked, 2.5 Sq mm (nominal area) single core with copper conductor, multistranded drawn through and including non metalic rigid PVC conduit of 25 mm dia and conduit accessones concealed in walls, floors, roofs etc, complete including moduler terminal box flush in wall with moduler cover plate of required module for mounting switches, socket, fan regulator etc including provisioning of FRLS, PVC insulated un-sheathed 1100 volts grade, ISI Marked, 2.5 sq mm solid/multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
47S&F Swich modular type single pole one module, 16 Amps complete all as specified and directed.
48S&F Socket outlet modular type, multipurpose, 2/3 pin single pole two module, 6/16 Amps complete all as specified and directed.
49Supplying and laying of CPVC pipes of dia 16 mm SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
50M & L for chemical earthingcomplete withcopper earth plate electrode90cm x 60cm x 5mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of Bentonite powder and common saltupto 1.5 meter depth all around the earth plate and connected to earth lead of copper strip 32x 6 mmby means ofbolts, nuts, check nuts and washers of copper and thimbles and other end of the earth lead connected to Plant/equipment and protected by galvanized iron or steel pipe light grade and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronze size 75x75x25 mm complete . Note : (i) On testing after completion of earthing if desired earth resistance below 5 ohms is not achieved, the earthing will be redone at no extra cost. (ii) 7.50 mtr length of copper strip shall be deemed to be included in the quoted rate.
51Supply and laying 32mm x 6mm copper strip at 0.5 mtr below ground as strip earth electrode including connections/terminating with nut, bolt, spring, washer etc as required (joiting shall be done by overlapping and with 2 sets of brass nut bolt and spring, washer spaced at 50mm)all as specified and as directed by Engineer-in-Charge.
52Supply & fix Air Circulator fans 230 volts single phase oscillating, Almonard Mark-II Wall Fan, 18 Inch (450mm), Aluminium Die-Cast blade, 3-speed control, powerful airflow, adjustable tilt 1400 RPMhigh speed suitable for wall mounting complete all as specified and directed.
53M&L for Point Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable concealed in surface / recessed with medium classPVC conduit 20mm dia, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required complete all as specified and directed.
54S&F Modular socket 6 Amp , 2 ModuleAC 230 volt of Anchor penta modular complete all as specified and as directed.
55S&F repairs PVC enclosure 3 module .suitable for 6A modular switch socket comb complete all as specified and as directed.

AI Tender Summary

OUR REF NO 51443737
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.93 Lakhs
LAST DATE 28-10-2025
Authority
Authority Name Military Engineer Services
Work Description Provision Of Civil And Electrical Works Including Geyser Installation Chemical Earthing Air Circulators Sign Board Road Furniture Sunshades Interlocking Tiles Water Tanks Rcc Benches Building Alteration Atration And Associated Infrastructure At Adrde
Basic Detail
Tender No GE/RND/T-02/GWL/2025-2026
Bidding Type Tender
Location
City gwalior
State Madhya Pradesh
Key Dates
Publish Date 23 Oct 2025
Submission Date 28 Oct 2025
Open Date 30 Oct 2025
Finance
Tender Value 24.93 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
Tendernotice_1.pdf
BOQ_820306.xls
b02050e4-fff0-4b30-ab33-d483df80cd6e.html
TDR.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 28, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 28, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 30, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_820306.xls

html

b02050e4-fff0-4b30-ab33-d483df80cd6e.html

pdf

TDR.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders