}

Tender For Spl Repair To Bldg No 27 And 105 B Or Living Of 13 Garh Rif Under Ge (South) Meerut Cantt, meerut-Uttar Pradesh

Tender Notice

51443577
Corrigendum : Tender For Spl Repair To Bldg No 27 And 105 B Or Living Of 13 Garh Rif Under Ge (South) Meerut Cantt
Tender
Indian
Uttar Pradesh
Meerut
22-10-2025

Tender Details

Tender For Spl Repair To Bldg No 27 And 105 B Or Living Of 13 Garh Rif Under Ge (South) Meerut Cantt; 1 Demolition ofbrick work or stone/boulder masonary built in cement mortar incl all quoins arches pillars etc.all as specified & directed 2 M&L brick work with sub class B Bricks old Size straight or curved on plan exc 6 m mean radis built in CM 1:6 3 M&L brickwork with subclass `B bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 except bricks complete all as specified and directed. 4 Dismantling timber scantlings 40 sq. cm and over in section as in framed work, in any position as in roof truss and Purlins complete all as specified and directed by Engr-in-charge. 5 S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats et conforming to I. S 1161-1979 grade St.-240 6 Dismantling asbestos cement (corrugated or semi corrugated ) sheets in roof covering complete all as specified and directed. 7 Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed. 8 Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall,fixed with self tapping screws as specified and directed. 9 S&F mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to FE 410-0 of 310-0 complete all as Specified and Directed. 10 Dismantling ceiling board of insulation boards including aluminium snap grid etc any thickness complete all as specified and directed. 11 Material & labour for provision of Powder Coated GI frame work(snap grid) suitable for size as in false ceiling of size 600mmx600mm consisting of followings andall as directed:-i) sections incorporated in frame work shall conform to designation 63400 given in IS: 737-1986. ii) The snap grid shall consist of GI anodized main /cross tee of size 36.5mmx25mmx1.4mm thick and 25mm x 25m x1.4mm thick, respectively.iii) Snap grid frame shall be fixed to ceiling withsupporting hangers consisting of S & F 2mm dia mild steel GI wire.iv) The main and cross tees shall be jointed at junction/crossings with GI anodized angle bracket, of size 15mmx15mmx1.4mm thick, fixed with suitable mild steel, bolts, nuts and washers all as per manufacturer’s instructions.v) The snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium anodized angle of size 25mmx25mmx1.4 mm anodizedthick. vi) Size of the snap grid shall be 605mm x 605mm. vii) Minimum average thickness of anodizing shall be 15 micron. 12 S&F 4 mm thick Gypsum Board in ceilingsize 60cm x 60cm fixed to aluminium snap gird complete all as specified and directed as per manufcturers instructions. 13 Dismantling, floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed. 14 Demolition of stone Slab Laid Bedded and pointed in any Mortar and tiles of any Description or thickness in floor, Apron etc complete all as specified and directed. 15 M &L for Non Skid ceramic tiles7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, white tiles,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:6 complete all as specified and directed 16 M &L for Non Skid ceramic tiles7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, white tiles,on vertical surfaceetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 10mm thick screed bed in CM 1:4 complete all as specified and directed 17 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.50 Sqm each. 18 Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.50 Sqm & n exc 4 Sqn each. 19 Supply & fixing pressed steel frames for doors with one or more rebates including necessary fitting lugs, hinges, lock strike plates etc completed size of frame 125x60mm made out of 1.25mm MS sheets complete all as specified & directed. 20 S&F for factory made 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides,complete all as specified. 21 M&L gauged shutter shall be made out of box section with outer & locked Frame of size 60 x 35 mm ( Medium Grade). The frame for shutter shall be of pressed steel including Fixing of10mm Square bars ( 06 Nos in Horizontal Direction & 05 Nos in vertical Direction ) complete with fly proof wire mesh having 0.63mm nominal dia wire and 1.4mm average with aperture including two coats of synthetic enamel paint over a coat of red oxide Primer including fixing of 02 Nos of MS Tower Bolts 200 mm Long & 01 Nos of MS Sliding Door Bolt 200 mm long complete all specified and directed by Engr-in -charge. 22 S&F Aluminium, anodized barrel tower bolts of extruded section and fixed, 200 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified. 23 S&F aluminium anodized handle of size 150 mm, ISI marked, complete all as specified and directed. 24 S&F aluminium alloy, anodised, sliding door bolt 250mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed ISI marked complete all as specified and directed. 25 S & F Floor Door Stopper 150 mm overall length of cover plate of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. 26 S&F mild steel 150mm size helical door springincluding roller and roller plate fixed with screws to wooden chowkat or welded to steel frame, complete all specified and as directed. 27 S&F Steel windows box type using P section comprising double frame for gauge and glazed skelton shutter jointly with flat iron 40x3mm complete including hinges, handle, tower bolts, stops, lugs etc all as shown on drawing.Note (i) For the perpose of measurement & payment double shutter with frame shall be considered as one unit (ii) Unit rate quoted against this item shall also include the iron mongreries shown on drgs (iii) gaurd bars glazing & Wire mesh shall be measured and paid for separately complete all as specified and directed. 28 Supply & fix galvanized mild steel wire cloth with 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed. 29 S&F 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading )in square n.exc 0.5 Sqm in each panes complete all as specified and directed. 30 M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-290 Gde-165 complete all as specified. 31 Taking down of cementplaster of any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc. 32 M & L 10 mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces finished even and fair complete all as specified & directed. 33 M & L 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth with out usingextra cement complete all as specified & directed. 34 Materials & labour for prepration of newely plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. 35 Materials & labour for prepration of Old plastered surface and finishing the surfaces of wallwith wall putty and applyingtwo coat of Oil Bound distemper over one Coat of Cement Primer of, any colour, complete all as specified & directed. 36 M &L Preparation of new plastered surface of wall by applying 2mm thick wall care putty and making the surface smooth Finishing walls and applyingAcrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) using roller for painting complete all as specified & directed. 37 M& L Preparation of Complete removal of existing treatment by mechanical means plastered old surface of wall and applying 2mm thick wall care putty over one coat of primer and making the surface smooth and applying two coat of Acrylic smooth exterior paint of required shade ( two coat @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm) using roller for painting complete all as specified & directed. 38 M & L For preparation of New or Previously untreatedWooden Surfaces of any description, over 10cm in width or girth, not otherwise described with Pink primer and apllying two coats of synthetic enamel paint Complete all as specified and directed. 39 M&L preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel Paint over one coat of Red oxide primer complete all as specified & directed 40 M&L preparation old painted steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel Paint over one coat of Red oxide primer complete all as specified & directed 41 Demolition of cement concrete of ground floor n exc 15 cm in depthin any position nototherwise specifically provided for, complete all as specified and Directed 42 M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cementall as specified and directed. 43 M&L PCC 1:3:6 type C-0 (using 12.5 mm greded agg) for hold fast pressed steel frame etc complete all as specified and directed. 44 Material & labour for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. 45 M&L 60mm thick PCC tile (interlocking type) jointed filled with sand and campacted with mechanical plate vibrator Complete all as specifed and directed. 46 M&L Sand for cushioning, interlocking tiles joint to be filled with sand, including spreading and levelling in layers n exc 25 mm thick Complete all as specified and directed. 47 M/L 75 mm thick cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base Complete all as specified and directed. 48 S&F Pre-cast cement concrete block masonry 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, including exacavation for fixing and making good complete all as specifed and directed. 49 Taking down carefully any type of battens or conduit point wiringwith or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge. 50 Material & labour forpoint wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSPVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunk zinc coated pressed steel terminal boxes with 1.2 mm thick including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for Onelight point / bellpoint controlled by one, one way switch 05 / 06 Amps for Onelight point controlled by one, one way switch 05 / 06 Amps. 51 All as per item No 50 here-in-before but one fan point controlled by one, one way switch 05 / 06 Amps. 52 All as per item No 50 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. 53 All as per item No 50 here -in- before but for One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. 54 All as per item No 50 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board. 55 Supply and fixswitch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge 56 Supply and fix socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed by Engr-in-Charge . 57 Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified and directed. 58 Supply & fixing of socket outlet3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified and directed. 59 Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed. 60 Supply and fix LED lamp 9/10 watt complete all as specified and directed. 61 Supply and fix in repairLED Tube lightfitting 1x20 Watt , with opal diffuser, environmental friendly, energy efficient MS batten with retrofit T8 polycarbonate tube-01 No, complete with all accessories and fixing material all as specified. 62 Supply and fixing LED building security light fitting 1x35 Watt luminarieswith die cast aluminium housing comprising epoxy poweder coated enclosed with glass cover in frame with high power LED white lampof capacity 35 watt including brackets of 32 mm dia GI pipe medium grade upto 0.6mtr long bend to 120 deg shape including flat iron clamps- 02 Nos with suitable size ofnuts and bolts including grouted in wallcomplete all as specified and directed., 63 Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge. 64 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed. 65 Supply and fixing MCB, SP, AC, 240 volts C series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed. 66 Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity32 Amps to 40 Amps10kA and making connections complete all as specified & directed. 67 Taking down unsv cable ofany type/size and S&F (in repair) , laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed. 68 Supply / laying and fixing 40mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed. 69 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft/ loose soil and gating out in soft / loose soil complete all as specified and directed. 70 M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed by Engr-in-Charge. 71 Material and labour for contineous brick laying dry equal to width of flyash designation 75kg/cm2complete all as specified and directed by Engr-in-Charge. 72 Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft / loose soil complete all as specified and directed. 73 Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed. 74 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and also including taking down old fans if required.(old fan deposited to E/M yard only) 75 M&L for Ceiling fan hook made from steel structural, bracing support bend into shape for hanging of ceiling fan complete all as directed at site. 76 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection, with the inbuilt orfixing of 1 No MCCB 4 Pole100Amps 36 KA, 415 volts and 12 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. 77 Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + 1 single core cable of 6.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existingand taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x6.0 Sqmm wire and one 6.0 sqmm earth wire shall be measured as one length). 78 Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-10-2025 BOQ Amendment BOQ 22-10-2025

Key Value

Document Fees
INR 1000 /-
EMD
INR 143215.0 /-
Tender Value
INR 78.81 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail