Tender For Water Supply Scheme Of Residential Area Sector 11 Gida Gorakhpur - CONSTRUCTION OF TUBE WELLTransportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 2 Transportation of 400 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 3 Transportation of 2 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 4 Logging of Bore 5 Drilling of 600mm dia bore from G.L. to 100m BGL. 6 Drilling of 600mm dia bore from 100m BGL to 200m BGL. 7 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 100m BGL. 8 Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 200m BGL. 9 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 200mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,M.S. ring 12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 10 200mm dia MSERW 7.1mm thick plain /slotted pipe including M.S ring 12mmthick , 1 noM.S. bail plug ,center guide etc comp in all respect. 11 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 12 Development of tube well by 400 PSI air compressor 13 Development of tube well by 1 cusec O.P. Unit. 14 Chemical and bacteriological test. 15 PUMPING PLANT1100 LPM, 57m head 1450rpm, 25 H.P. submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) Switch gear with soft starter and cable 16 SITC of 150mm dia size main piping and valves with 36mtr column pipe, Automatic chlorination system (SCADA compatable), power wiring, earthing, painting, tool set, wiring of pump house, chain pulley block and gauges complete in all respect with all required material, T& P labour. 17 SITC of 40 KVA voltage stabilizer . 18 RISING MAINSupply of the following sizes of D.I. pipes Class K-7 conforming to latest I.S. 8329/2000 complete in all respect F.O.R. destination including all taxes and insurance.200 mm dia DI K-7Tube well -1 to OHTTube well -2 to OHTTube well -3 to OHTBye Pass arrangement 19 Supply of D.I. S/S or flanged Specials conforming to I.S. 8329/2000 Suitable for above C.I.S/S pipe F.O.R destination including all Taxes and insurance. Total Cost of item Nos-1 20 Supply of the following sizes of D.I. Double flanged sluice valves as per I.S. 780/1969 class-1 working pressure 10kg/Sqcm F.O.R Destination including all taxes and Insurance.200 dia dia 21 Excavation for pipe line trenches in ordinary soil,(lime, clay or sand including lift up to 1.5m and lead up To 50m and refilling, watering, ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.200mm dia H-7 22 Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe k-7 and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints.200 dia dia 200mm dia K-7 23 Carting of D/F Sluice valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete excluding values and specials required but including the testing etc. complete.200 mm dia 24 Supply of all materials, labour T&P etc. required and construct masonry type sluice valves chamber as per type design including supply and materials labour, T&P etc. complete. 25 Supply of all materials, labour, T & P etc. required and construct thrust blocks at the bends. 26 OVER HEAD TANKSupply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911 including submission of structural design and drawing prepared by authorized strucural engineer and approved by the department including 3m extra height1200 K.L. with 24 M staging 27 Testing of bearing capacity of soil from a reorganized Govt. Engineering College or as directed by department. 28 Extra Inlet for 2 no T W 29 Supply of 200mm dia PVC pipe as per latest/relevant I.S. specification including all taxes and insurance etc. F.O.R. destination for disposal of water from overflow and washout chamber to suitable points outsides the water works compound including excavation. 30 PUMP HOUSEExcavation in foundation in ordinary soil(loam, clayorsand) including lift up to 1.50 m & lead up to 50 m, refilling,wateringand rammingof excavated earth intothe trenches or spacebetweenthe buildingand sidesof foundation trenchesorinto the plinth and disposalofsurplus earth up to the distance of50from thecenterofthefoundation 31 Concretewith40mmgauge stone ballast, coarse sandand cementin proportionof(8:4:1)in foundations andfloorsincluding supplyofall materials, labour, T&P etc. required for proper completion of the work. 32 Ist.Classbrickworkin1:4 cement and Coarsesandin foundation and plinthincluding supplyofall material, labour T & P etc. required for proper completion of work. 33 20mm thick D.P.C.with cement and approved coarse sand 1:2 including 5% water proofingmaterial or in proportion asspecified by the manufactures includingsupply of all material, labour T&P etc. required for propercompletionof work. 34 Ist. Classbrickworkin1:4 cement and coarse sand in super structure including supply of all material, labourT&Petc.requiredforproper completion of work. 35 Brick work (1:4) 36 Supply ofM.S. angle iron chaukhats of 40 mmx 40 mm x 5 mm withM.S.sheet door shutter including simplemoulding straight workasinchaukhatsand also supplyofall material, labourT&P etc. required for proper completion of work. 37 Supply and fixingofholdfast ofdoorsand windows chaukhats already molded on chaukhatsinP.C.C. 1:2:4 etc. Required in all respect to complete the work. 38 R.C.C. workwith cement, coarse sand and20mm gaugeapproved stoneballastin proportionof 1:1.5:3in sun shed andlintel on doorsandwindows excluding supply of reinforcement and its bendingbut including itsfixing and binding the same with 0.50 mm thick binding wire and the cost of binding wire andincluding necessary centeringandshutteringsupplyofall material,labourT&Petc. 39 Supply and fixingofholdfast ofdoorsand windows chaukhats already molded on chaukhatsinP.C.C. 1:2:4 etc. Required in all respect to complete the work. 40 M. S. or iron work in plain work such as R.C.C. or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completionoftheworkincludingsupply of steel 41 Supply and fixing of door and window shutter 42 12 mm thick plaster with cement and coarse sand mortar I:4 over brick work minimumthicknessnottobe lessthan10 mm including supply of all material,labourT& P etc.requiredforpropercompletionof 43 Sameasitemno.13but in 1:4 cement sand mortar but over ceiling Plaster including supply of all material, labour T & P etc. required forproper completion of work. 44 Supply and fixing of 22 mm wide and 3mm thick glass stripsinpanels including supply of all material, labour T&P etc. requiredfor propercompletion of work. 45 25mm thick 1:2:4 plain cement concrete floor with cement coarse sand and 20mm gauge stone ballast laid in panels finished with3mm floating coat of neat cement or cement and marble dust in ratio 1:5 as specified and removingany overlapping or mortar at the joints of panels if any and giving them uniform finish including. 46 Painting or varnishingnew workor new wood work in small areas with one priming coat and two coat of approvedquality paint orvarnish including supply of all material, labour T&P etcrequired for proper completionof work. 47 Providing and applying white cement basedputtyof average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Painting / Finishing walls with Premium AcrylicSmoothexterior paintwith Silicone additives of required shade . New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). 49 SupplyandfixingofGirderof 250 mm x 125mmsizeoverthe pump houseincluding its painting with approvedquality paint and also onepriming coat. 50 Sandfillinginplinthinpump house andchlorinatingroom including supply of all material, labourT&Petc. required for propercompletionof work. 51 Supply & Fix 90 mm dia P.V.C. down pipescompletewithrose& bend and gratingswith M.S. clamps 25 X 3 mmfixed on walls & supply of 150 mm long, 6 mm dia nails complete. 52 Construction of R.C.C. 1:1.50:3 manhole cover 70x70 cm for opening in roof slab and fixing it at opening including supply of all material, labour T&P etc. complete. 53 Making opening in walls of size 60x30 cm supply and fixingofR.C.C.jalies andplasteringthe sameincluding supply ofall material, labour T&P etc. complete. 54 Supply and laying 40mm thick insulation layer of sand and clay over roof 55 Supply and fixing of oxidized ironfitting of approved make for doors and window 56 Site clearance and other unforeseenitems 57 BYE PASS CHAMBERExcavationinfoundationinordinarysoil(loam, clay or sand) including lift upto 1.50m and lead upto 50mandrefilling,watering,rammingof excavated earthintothespacebetwwenthe building and sides of foundation trenches or into the plinth and disposal of surplus earth upto the distance of 50m from the center of the foundationtrenches. 58 Ist.Classbrickworkin1:4cementand Coarse sand in foundation and plinth including supply of all material, labour T & P etc. required for proper completion of work. 59 Concrete with 40mm gauge Stone ballast, coarse sand and cement in proportion of8:4:1 in foundation andfloorsincludingsupplyofall materials,labour,T&Petc.requiredforproper completion of the work. 60 Supplycuttinganddressingwithsizeand fixingV- Notchofsize90x90cmintheby pass chamber including prepration of by passchamber asper directionof E/I including supply of all material, labour T & P etc. required for proper completion ofwork. 61 40 mm thick 1:2:4 plain cement concrete floor with cement,coarsesandand20mmgaugestone ballast, land in panels, finished with 3mm floating coat ofneatcement,includingsupplyofall materials, labourT&Petc.requiredforproper completion ofthe work. 62 12 mm thick plaster with cement and coarse sand mortor in 1:6 over brick work minimum thickness not to be less than 10mm including supplyof all materials, labour,T&Petc.requiredforproper completion of the work. 63 Supply & fixing 160mm dia 6kg/F PVC pipe 64 Supply of PVC special. LS10% OF Item nos- 63 65 Site Clearance and other unforeseen items 66 C/C Length Of P.H. - 23.44M. 67 supply and filling of earth in to plinth includingalllabour T&P & watering ramming dressing etc complete.HP 68 BOUNDARY WALLExcavationinfoundationin ordinarysoil(loam, clay or sand) including lift upto 1.50m and lead upto50mand refilling,watering,ramming of excavatedearthintothe spacebetwwenthe building and sides of foundation trenches or into the plinth and disposal of surplus earth upto the distance of 50m from the center of the foundationtrenches. 69 Concretewith40mmgauge stone ballast,coarse sandand cementin proportion in 8:4:1 in foundation includingsupplyofall material, labour T & P etc. required for proper completion of work. 70 R.C.C.workwith cement,coarse sand and20 mmgaugeapproved stone ballastinproportionof 1:1.5:3in columnexcluding supply of reinforcementand itsbending but includingits fixing and binding the same with 0.50 mm thick binding wireand the cost ofbinding wire and including necessary centering andshuttering supply of all material labour T&P etc. requiredfor proper completion of work. 71 Ist.Classbrickworkin 1:4 cementandcoarse sand mortarin foundation and plinthincluding supply of all material, labour T & P etc. requiredfor proper completion of work. 72 20mm thick D.P.C. with5% water proofing material including supplyofall material,labour T&P etc. required for proper completion of work. 73 Ist.Classbrickworkin1:6 cement and coarse sand in superstructurein onebrick thickwall including supply of allmaterial,labourT&P etc. requiredforproper completionof work. 74 R.C.C.workwith cement,coarse sand and20 mmgaugeapproved stone ballastinproportionof 1:1.5:3in columnexcluding supply of reinforcementand itsbending but includingits fixing and binding the same with 0.50 mm thick binding wireand the cost ofbinding wire and including necessary centering andshuttering supply of all material labour 75 M. S. or iron work in plain work such as R.C.C. or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completionof thework includingsupply of steel for column 12 mm dia 76 C.C.copingonboundrywall in1:2:4 cement, coarse sand and stone grit(10-12.5 mm) including supply of all material, costof centering,shuttering with extralabour,T&Petc. complete required for proper completion of work. 77 12 mm thick plaster1:4 cement and coarse sand in superstructureinone brick thickwall including supply of all material, labour T & P etc. required for proper completion of work. 78 Providing and applying white cement basedputtyof averagethickness1 mm, of approved brandand manufacturer, over the plastered wall surface to prepare the surface even 79 Painting / Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additivesofrequired shade . New work (Two or more coats applied@1.43ltr/10sqm overand includingpriming coatofexterior primer applied @ 2.20 kg/10 sqm). 80 Siteclearanceandother unforeseen items complete 81 I class brick work in1:6 cement and local sand mortar in foundation and plinth including supply of all materials labour, T& p etc. required for proper completion of the work 82 GATEExcavation in foundation in ordinary soil (loam, clay or sand) includinglift upto1.50 m&lead up to50m, refilling,watering and ramming of evcavated earth intothe trenchesor space betwwen the building and sides of foundation trenches or into the plinth and disposal ofsurplus earthup to the distance of 50 mfrom the center of the 83 Concretewith40mmgauge stone ballast,coarse sandandcementin proportionin 8:4:1in foundation including supply of all material, labour T & P etc.requiredforproper 84 Ist.Classbrickworkin 1:4 cementandcoarsesand mortarin foundation andplinthincluding supply of all material, labour T & P etc.requiredfor proper completion of work. 85 R.C.C.workwith cement,coarse sand and20 mmgaugeapproved stone ballastinproportionof 1:1.5:3in columnexcluding supply of reinforcementand itsbending but includingits fixing and binding thesamewith 0.50 mm thick binding wireand the cost of binding wire and including necessary centering and shutteringsupply of all material labour T&P etc. requiredfor propercompletion of work. 86 Supplyand fix M.S. Clamp of size 50x50x6 mm for gates including supply of allmaterial, labour T & P etc.required for proper completion of work. 87 M. S. or iron work in plain work such as R.C.C. or R.B. work (when not included in over all rates) brought to required shape as necessaryincluding bending for proper completionof the workincludingsupply of 88 SupplyandfixingofM.S. angle iron gateof40mm x40mmx3mm including simplemouldingstraightg work s and also supplyofall material, labour T&P etc. required for proper completion of work. 89 1.2 M Wicket Gate as per type Design. 90 Fixingof20mmdia conduit pipe includingcutting andspecials etc. for electricwiring including supply of all material, labourT&P etc.required forproper completion of work. 91 Painting or varnishing new workor newwoodworkin small areas with onepriming coatandtwocoatof approved quality paint or varnish including supply of all material, labour T & Petc. requiredforproper completionof work. 92 Finishing walls with water proof cementpaint of approved make andquality on newworkwith two coats togive aneven shade includingsupplyof allmaterial,labourT&Petc.requiredfor proper completion of work. 93 Supply and fix in position 4 mm thick glass ofsize30x20cm with suitable frame in light box in 94 Siteclearanceandother unforeseen items. 95 Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road in water works campous. 96 Provide all materials, labour T&P etc. required for proper completion of work including levelling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth. 97 Provision for arboriculture for development of water works compound. 98 Site clearance and other unforeseen works. 99 STAFF QUARTERExcavationinfoundationinordinarysoil(loan,clay,and /or sand) including lift up to 1.5mand leap up to 50ni refilling,watering,andrailJmingofexcavatedearth into thetrenchesorintothespacebetweenthebuilding and sidesoffoundationtrenches,orintotheplinth and disposalofsurplusearthuptoadistanceof50m fromthe center of the foundation trenches. 100 Concretewith40mmgaugebrickballast,localsandand cement in proportion of 1:6:12 in foundation including supply of all materials, labour, T&P etc required for proper completion of work. 101 First class brick work in 1:6 cement and local sandmortarinfoundationandplinthincludingsupplyofall materials,labourT&Petcrequiredforproper completion of work. 102 25mmthickdampproofcoarsewithcement,stonegrit12mmandapprovedcoarsesand1:1.5:3with and includingwater-proofingmaterialsasorderedby the Engineer-inchargeinthe proportionasspecifiedby the manufactures, also included bitume painting(85/50 or 85/25),supplyofallmaterials,labourT&Pand toolsand plantsetcrequiredforpropercompletionof theworkand including proper curing and shuttering as necessary. 103 Sandfillinginthefoundationincludingsupplyoflabourmaterial ,T&P etc . 104 IstClassbrickworkin1:4cementandlocalsand mortar insuperstructureincludingsupplyofallmaterial, labour, T&P etc required for proper completion of the work. (Thickness of wall to one brick thick). 105 12 mm thick plaster with cement and sand mortarinproportionof1:6overbrickwork,minimumthickness not be less than 10mm ,including supply of all materiaIs,labour ,T&P etc for proper completion of work. 106 20mmthickcementplaster,inDadoorskirtingwithcement and coarse sand mortar 1:2 laid in panels and finished with 3mmfloating coat of neat cement or 1:5 cementandmarbledust,includingsupplyofall materials,Iabour ,T&P etc for proper completion of work. 107 Sameasitemno14butinproportion1:4withcementand local sand mortar, over ceiling. 108 Struck pointing in ce vent mortar 1:2 with colouring material to match with the brickwork colour including supply of all materials ,labour, T&P etc required for proper completion of work. 109 R.C.C.workwithCementapprovedCoarsesandand20mm Gaugeapproved stoneballast in the proportion 1:1.5:3inlintelsofdoors,windows &sunshadeexcluding reinforcement anditsbendingbutincludingits fixingand bindingthesame24BWGwireinposition withsupply allmaterialslabourT&P etcrequired forproper completion of work. 110 MildsteelorironworkinplainworksuchasRCCorRBwork (when not included in overall rates )brought to requiredshapeasnecessary,including bendingand supply of steel and wastage for completion ofwork 111 SupplyandfixingofMSangleironchaukhatsof40x40x6mmsizeincludingsimoemouldingstraightwork asinchaukhatsandalsosupplyofallmaterials,labour, T&P etc required for proper completion of work. 112 Supplyandfixholdfastindoorsandwindowschaukhats25cnlx50mnlx6mm flat iron including their cutting,mouIding, welding to requirwed shape also including othermaterialssuchasnailsandscrews etcrequiredin all aspect to complete the work. 113 Mild steel grill in windows wrought to requiredform,incIuding supply of labour, steel ,T&P etc for proper completion of work. 114 25 mm thick (1:2:4) plain cement concrete floorwith cementcoursesandand20mmgaugestone ballast,laid in panels, finished with 3 mm floating coat of neat cementorcementandmarbledust in ratio1:5as specified,andremovingany overlapping ormortaratthe jointsofpanelsifanyand givingthemuniformfinish, includingsupplyofall materials,labour,T&Petc. requiredforproper completionofthework.including75 mmthickbase concreteconsistingofcement,localsand andfirstclass brickballast40mmgaugeinproportionof 1:4:8 including supply of all materials, labour T&P etc required for proper completion of work. 115 Sameasitemno16aboyebut40mmthickoverbaseconcrete consisting of cement, local sand and 40 mm gaugefirstclassbrickballastintheproportionof 1:4:8. For construction of apron 0.6 m wide. 116 First class brick a ork in ”1:4 cement and local sand mortarinsuperstructureincludingsupplyofall materials labour T&P etc required for proper completion ofapron 0.6 m wide work. 117 Supply of 40 mm thick sheesham wood door/window shutters with 9 mm thick Plywood or pressed Wood pannels and fixing Cleats, stops,hinges, locks, bolts, handlers,springandotherfittings. (Excludingsuplyof Fittings). 118 Supply and fixing of oxidized iron fittings ofapproved make for doors and windows. 119 PaintingorVarnishingnewironworkornewwoodwork in small/largeareas with onecoatprimingand two coat of approvedpaintorVarnishinclduingsupply ofall materials,labourT&Petc.completerequiredforproper completion of the work. 120 White washing in three coat including supply of all materials,labour,T&Petc.completerequiredforproper completion of the work 121 ProvidingplasterofPariswallputtyof2mmthicknessover plastered surface to prepare the surface even and smooth complete. 122 Finishingwallswithoilbaseddistemperpaintof approvedmakeandqualityoveroneprimingonnew work withtwocoatstogivenanevenshadeincluding supplyof allmaterials,labourT&Petcrequiredforproper completion of work. 123 Provideallmaterial,labour,T&Petc.andconstruct100mmdiasemicircularC.C.covereddraininclduing rendering the surface smooth with neat cement. 124 Supply of all materials, Iabour,T&P etc and constructinspection chamber as per type design and drwaing. 125 Supplying,carting,laying,jointing,fixingandtestingof(1/2 -1 inch) CPVC Screwed pipe with specials and fittingsinclduingcuttingholesinmasonryandmaking good the wall, fixing clamps wherever necessary etc. complete icluding cost of white lead, hemps, oil, etc. 126 Supply and Fixing ofwater taprequired for proper comletion of work 127 Supplyofallmaterial,labour,T&Petcfixingoffloatvalverequired for proper completion of the work. 128 Supplyandfixingof110mmdiaPVCpipefromUtraptoseptic tank including supply of all special materials required for proper completion of the work. 129 Provisionforinternalelectrification includingsupplyofall materials, labour, T&P etc. complete. 130 Supplyandfix110mmC I downPipewithrose heads,bends, gratingswithnecessaryMSclamps25mmx 3mm fixed with walls including supply of150mm long6mm dia nails including supply of all materials ,labour etc for proper completion of work. 131 20mmthickcementplaster,inDadoorskirtingwithcement and coarse sand mortar 1:2 laid in panels and finished with 3mmfloating coat of neat cement or 1:5 cementandmarbledust,includingsupplyofall materiaIs,Iabour ,T&P etc for proper completion of work. 132 Constructionofseptictankandsoakpitincludingsupply of materials labour etc complete.(Ready made) 133 Supplyandfix in position500litrecapacity PVC(Sintexor other approved make ) storage tank. 134 Supply and fix indian type latrine seat with U-Trapincludingsupplyofallmaterials,labour,T&Petc. required for proper completion of the work. 135 Provision for electrification outside of the quarter. 136 Site clearance and other unforeseen items. 137 GROUND WATER RECHARGEDRAIN OF 450 X 300 MMEartk work in Exacavation in foundation 138 Providingand layingofPCC witk 1:4:8 cement,sand and 40mm gauge brick ballast including supply of all materials, 139 Rcc 1:1.5:3cement and coarse sand mortarinfoundationand plintkincludingsupplyofall materials, labour T8Petc. Required 140 In walls 141 MS work inRCC work wrought to required size& shape icluding supply of steel and wastage etc proper competion of work.(1% of RCC) 142 Site clearance and otker unforseen 143 SETTLINGEarth work in excavationof earth and out at same for construction settling tank.Upto1.50 M depth. 144 1.50 M to 3.00 M depth 145 Plasterwork12mmthickin1:4 cementmortarwithcementandcoarsesand mortar. 146 MS work slab of settling tank. 147 R.C.C. work in 1:1.5:3 with cement coarse sandand20mmstoneballast complete work with supply of all materials placing of steel and concrete etc. all complete. 148 ConstructionoffabricatedMS Manhole coverHD20with angleiron andshutter withlockingarrangement andstrainerin wall for water storage. 149 Fixing of angle iron footrest in wall of settling tank with weeding mounding etc.all complete. 150 Site clearance and other unforeseen items. 151 RECHARGING WELLSupply of PVC pipe 6 Kg/Cm2 110mm OD with coupler. 152 Supply of bell mouth piece for top face of well with jali. 153 LabourCartingofPVCpipeof110mmdia6 Kg/Cm2from storetositeofworkwith loading, unlaoding etc. all complete. 154 Making 150mm dia nominal dia bore palm and pressure method complete work. 155 Lowring of 110mm dia PVC pipe in prepared bore. 156 Provision forslotted pipe for dischargeof water. 157 Fixing of bell mouth piece at top of 110mm dia pipe of boring. 158 Site clearance and other unforeseen items. 159 PHASE I.DISTRIBUTION NETWERKSupply of the following size and type of pipes with coupler and all jointing materials such as solvent cement rubber rings etc. including F.O.R. destination and all taxes, insurance and with loading unloading and stacking etc. completeD I Pipe K-7300 mm dia 160 250 mm dia 161 200 mm dia 162 H D P E Pipe PN-6160 mm dia 163 140 mm dia 164 110 mm dia 165 90mm dia 166 Supply of special for above pipes 167 Supply of special for above pipes 168 Excavation for pipe line work in ordinary soil (loam, clay or sand) for pipe line trenches including lift up to 1.50m and lead up to 50m and refilling, watering ramming of excavated earth in to trenches and disposal of surplus earth up to 50m from centre 169 Carting of the following sizespipes and special from department store to site of work. (within 8 km or within municipal limit) and lowering them in to trenches and laying true to alignment and gradient including testing of pipeline .D I Pipe K-7300 mm dia 170 250 mm dia 171 200 mm dia 172 H D P E Pipe PN-6160 mm dia 173 140 mm dia 174 110 mm dia 175 90mm dia 176 Supply of the following size of C.I.D./F sluice valves and scour values as per ISS class 1 working pressure 10kg/cm2 F.O.R. destination including all taxes and insurance.Sluice valves300 mm dia 177 250 mm dia 178 200 mm dia 179 150 mm dia 180 100 mm dia 181 80 mm dia 182 Supply of 20 mm screwed down type air valve with gun metal seat F.O.R. destination including all taxes and insurance.20 mm dia 183 supply of sluice valve type fire hydrant consisting of 80 mm dia sluice valve 80 mm dia tail pieces 80 mm dia duck foot bend and 63 mm dia standard making iron coupling with cap conforming to latest relevant I.S. specifications including all tax and insur 184 Carting of C.I.D./F sluice valves and scour valve of following sizes to the sites of works lowering them into already prepared trenches and fixing them into position including supply of jointing materials such as bolts, nuts, rubber, insertion, white lead etc complete.Sluice valves300 mm dia 185 250 mm dia 186 200 mm dia 187 150 mm dia 188 100 mm dia 189 80 mm dia 190 Carting from site store the 20mm dia screwed down air valves to the site of works loweringthem into already prepared trenches and fixing them in position including boring and threading the main etc complete and including the cost of bailing out of water. 191 Carting of 80 mm dia flanged fire hydrant to the site of work lowering them into already prepared trenches and fixing them in position including boring and threading the main etc complete including cost of bailing out of water supply of jointing materials 192 Provide all materials labour T&P etc. required and construction single tap pillar type stand post as per departmental type design. 193 Supply of all materials labour T&P etc required and construct following chamber as per departmental type design masonry type.Sluice value chamber (masonry type) 194 Sluice value chamber (surface box type) 195 Fire Hydrant (Chamber) 196 Air Value Chamber 197 Dismantlingof following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials up to a distance of 50m.Bituminous Road 198 Reinstatement of following type of surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials up to a distance of 50m.Bituminous Road 199 Provision for crossing of nalas , road, culvert and embankments(bundhs) etc. including shifting of telephone cables etc. along the alignement ofPipe line including supply of C.I.Tyton pipes and specials, and their laying and jointing testing etc. complete.Trenchless crossing 7.0 wide road 200 Making Commrcial Connection with 25mm (OD) MPDE pipe with (63mm to 160mm) distribution main. 201 POWER CONNECTION Power Connection from UPPCL for 25 KW load with 40 KVA transformer.