| 1 | Chirakkadavu GP Project No:- S0230/26-MAINTENANCE OF 15 WARD DRINKING WATER PROJECT (List of materials used for the work approved by the DLTCE under LSGD Kottayam is attached as separate document) |
| 2 | OD256174/2025-2026:Supply and providing L&T make upto 10 HP MUG STARTER 20 SMART CONTROLLER (CS91531CSDO) with complete operation (Remote ON/OFF, parameter setting, monitoring and troubleshooting through SMS or SMART COMM App or IVRS)with digital control panel and protection against overload, auto on or auto off timer, dry run, high and low voltage, single phasing, unbalance. |
| 3 | OD253901/2025-2026:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection. |
| 4 | 90.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm |
| 5 | OD253892/2025-2026:Supply and fitting KARTAR NRV CI HEAVY ISI 65MM[21/2" using required bolt and nut and flange etc |
| 6 | OD253903/2025-2026:Supply and fitting 65 mm KARTAR Sluice valve on existing GI pipe with flanges etc |
| 7 | OD253891/2025-2026:Supply and provide clamp set for pump set |
| 8 | OD253906/2025-2026:Supply and fitting 63 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main. |
| 9 | OD253900/2025-2026:Supply and Providing 63 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc |
| 10 | OD253897/2025-2026:S&I of Pressure meter with acessories and stopper valve, ball valve etc on delivery side of 63 mm GI pipe line as required |
| 11 | OD253902/2025-2026:Supply and fitting 60 mm flange with bolt and nut duly welded |
| 12 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 13 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm |
| 14 | 90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run |
| 15 | 90.11.1.14:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 16 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 17 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 18 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 19 | OD256168/2025-2026:Supply and Installation of Thermo Circuit Breaker Box Glass Door Enclosure 8 way IP65 HENSEL makefor surge protection device |
| 20 | OD256169/2025-2026:Supply and installation of Type 1+2,Surge Protection Device having Configuration 3P+N,4module,Maximum Discharge Current-Imax upto 100KA,,in the existing enclosure and giving connections as required (L&T Make AUSP123PN100 or equivalent) |
| 21 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 22 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 24 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 25 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 26 | OD253898/2025-2026:Supply and providingof 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required |
| 27 | OD253905/2025-2026:Supply and Installation of dust and vermin proof,wall mounting,Sintex meter box of size 650*350*210mm suitable for fixing KSEB meter,fuse units,neutral link etc. (GSMB6535) |
| 28 | OD253908/2025-2026:Supply and providingL&T make HRC fuse base with 63A Fuse Link to the Meter Boxas required and giving connection . |
| 29 | OD253893/2025-2026:S&F 32 A Two way N/L mounted on DMC/ SMC baseconnection etc |
| 30 | OD253904/2025-2026:Supply and providing anchor bolt hook type on wall/parapet for binding KSEB Service connection capable as required |
| 31 | OD253899/2025-2026:Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB |
| 32 | OD256276/2025-2026:Supply and Installation of 25x3 cu. strip Earth bench used for connecting copper conductor |