| 1 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed. |
| 3 | Excavation in trenches exc 1.5m wide and n.exc 3 m depth for foundation etc and getting out in soft/ loose soil complete all as specified and directed. |
| 4 | Excavation in trenches exc 3.0m wide and n.exc 3 m depth for foundation etc and getting out in soft/ loose soil complete all as specified and directed. |
| 5 | Removing excavated material exc 50m but n.exc 250m complete all as specified and directed. |
| 6 | Returning filing in soil including spreading, levelling, watering and well rumming in layers n.exc 25cm thick complete all as specified and directed. |
| 7 | M&L for PCC 1:4:8 type D2 (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 8 | M&L for RCC M-25 Design mix (20mm graded stone aggregate) for Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for RCCM-25 Design mix (20mm graded stone aggregate) for column piller, pier postcoping complete all as specified and directed. |
| 10 | M&L for RCCM-25 Design mix (20mm graded stone aggregate) forBeams, cantilevers, bressummers, lintels over 1.5m span, RCC coping complete all as specified and directed. |
| 11 | Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any)of foundation and plinth beams and similar vertical or to a batter flat rough finished surface complete all as specified and directed. |
| 12 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions suare and rectanguar complete all as specified and directed. |
| 13 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs etc also splays between floors and beams etc for fair finished flat surfaces complete all as specified and directed. |
| 14 | M&L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 15 | M&L for hard core of of broken stone or boulders of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 16 | M&L for PCC 1:3:6 type B2 (Using 40mm graded stone aggregate) 100mm thick for sub base with out using exatra cement complete all as specified and directed. |
| 17 | M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) 50 mm thick as in flooring complete all as specified and directed. |
| 18 | M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) 25mm thick as in flooring and finishing the surface even and smooth with using extra cement complete all as specified and directed. |
| 19 | M&L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection fisished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for brick work in cement mortar 1:6 straight on curved on plan exc 6m mean radius using sub class \"B\" brick complete all as specified and directed. |
| 21 | M&L for rendering in cement mortar 1:4 on fair faces of brick concrete surfaces 15mm thick and finished even and smooth complete all as specified and directed. |
| 22 | M&L for rendering in cement mortar 1:6 on fair faces of brick concrete surfaces 10mm thick and finished even and fair complete all as specified and directed. |
| 23 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint (Camouflage pattern) having VOC less than 50gm/Litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43/10 Sqm complete all as specified and directed. |
| 24 | M&L for preparation of newly plastered surfaces of walls and applying Three coats of White wash complete all as specified and directed. |
| 25 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Roof/ valley gutter/ cladding to wall, fixed with self tapping screws as specified all joints to be sealed by silicone sealant complete all as specified and directed. |
| 26 | S&F for Plain, black, mild steel sheeting in ridges 0.63mm, hips valley gutters, drip and straight flashing (length and girth as fixed) complete all as specified and directed. |
| 27 | M&L for Banks, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges, largehasps and staples, chains, hand made sliding bolts, clamps, hold fasts, will ties; hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and directed. |
| 28 | S&F for structural steel work Fe-410-W(Gde-E-250) quality-B as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 29 | S&F for tubular trusses including special shaped washer etc complete using ERW or including butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified.Steel work in tubular trusses complete all as specified and directed. |
| 30 | S&F for Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square n.exc 30cm long complete all as specified and directed. |
| 31 | S&F for MS TMT steel bars 10mm dia and over cut to length bent to shape reqd incluing cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | S&F for MSTMTsteel bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length bent to shape required incluing cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | S&F for half round PVC rain water gutter of dia 250mm with brackets and necessary connections complete all as specified and directed. |
| 34 | S&F for PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 35 | S&F for 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 36 | M&L for forming 12mm thick expension joints, 100 mm thick concrete slab, filled with pre-formed bituminous filler and top 30 mm primer and sealed with sealing compound grade \"A\" complete all as specified and directed. |
| 37 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed. |
| 38 | S&F for Mild steel rag or lewis bolts 12mm dia, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n.exc 15cm long complete all as specified and directed. |
| 39 | M&L for Providing precast cement concrete 1:2:4 12.5mm graded stone aggregate (type B-0) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (pre cast frame shall be measured separately and paid for under item 04032) complete all as specified and directed. |
| 40 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm complete all as specified and directed. |
| 41 | M&L for provision of PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 42 | M&L for PCC 1:4:8 type D2 75mm thick (using 40mm graded stone aggregate) as in sub base in flooring work complete all as specified and directed. |
| 43 | M&L for PCC 1:2:4 type B-1, 50mm thick (using 20mm graded stone aggregate) as in flooring work complete all as specified and directed. |
| 44 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 10 cm long dia bolt 16 to 20mm complete all as specified and directed. |
| 45 | M&L for point wiring with 1.5 Sqmm cable PVC unsheathed and insulated copper multistranded conductor(FRLS) 1100 Volts grade cable (red colour cable to be used for Phase connection and black colour cable to be used for neutral connection)including PVCconduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated (green colour) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.2 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and directed. |
| 46 | Light/Fan/Exhaust fan |
| 47 | 5 Amp switch socket on Independent Board. |
| 48 | All as per item No 45 here in before but 4.0Sqmm PVC insulated un sheathed cable with stranded copper conductor for 5 pin 6/16 Amp switch socket combination on independent board complete all as specified and directed. |
| 49 | S&F for switch socket combination 2 in 1, 5/6 Amps flush type230/240 V complete all as specified and directed. |
| 50 | S&F for switch socket combination 3 pin, 15/16 Amps flush type 230/240 V complete all as specified and directed. |
| 51 | S&F for ceiling rose 3 phase/ PVC/ polycarbonate,isolated body,surface type with ISI marked complete all as specified and directed. |
| 52 | S&F for switch piano flush type 5/6 amps, 240 volt single pole one way complete all as specified and directed. |
| 53 | S&F for wall decorative ultra slim LED 20 Watt, 230 volts, 50 Hz, 4 feet, lighting fixture with extruded polycarbonate lighting fixture, environmental friendly, energy efficient ready to use pack including lamp complete all as specified and directed.Make : Crompton Cat Part No TCS-109-20-65-SL-DP-NWH. |
| 54 | S&F for building security light LED type of minimum 3500 Lumens (35watts) pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and directed.ake : Crompton Cat Part No TRP-400-35-57-SL-LM-NSR. |
| 55 | S&F for factory made sheet metal enclosure for DBs double door, SPN, 240 volt,4 Way, IP-42 protection with bus bar, neutral link, earth link complete all as specified and directed. |
| 56 | S&F for 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SP 10 to 32 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 57 | S&F for 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SPN 32-40 Amp current carrying capacity complete with connection testing complete all as specified and directed. |
| 58 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed. |
| 59 | S&F for GI Pipe of 25 mm dia light grade for cable protection pipe complete all as specified and directed. |
| 60 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 61 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured & paid. |
| 62 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick including taking out old complete all as specified and directed. |
| 63 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6.3mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion complete all as specified and directed. |
| 64 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |