| 1 | Sch \"A\" |
| 2 | M&L for opening electric geyser of capacity 25/35 litre, taking out the inner tank, glass wool, geyser assembly, heating element and thermostat etc., cleaning, paintingthe complete geyser using iron brush/ iron rod and taking out the dirt & other deposits, re-assembling the geyser after replacing the defective parts and refilling the glass wool etc including taking down existing geyser after disconnecting water supply and electric connection and re-connecting the same after repairs complete all as specified & directed .Note :- Replacement of geyser parts and connected items as required shall be measured and paid for separately under appropriate item of this Schedule. |
| 3 | Supply and replacement of heating element single phase 230 volts with rubber gasket; push type round/triangular shape of capacity 2 KW complete all as specified & directed |
| 4 | Supply and replacement of thermostat single phase 230 volts with setting range 0° C to 85°C complete all as specified & directed. |
| 5 | Supply and replacement of geyser assembly having copper base and piping with 9/8/6 holes complete all as specified & directed. |
| 6 | Supply and replacement of worn out/ leaking inner steel body water tank for 25 litre capacity geyser complete all as specified & directed. |
| 7 | Supply and replacement of base platewith indicator lamp (Red and green) in two parts of size complete all as specified & directed. |
| 8 | Supply and replacement of air/pressure release valve complete all as specified & directed. |
| 9 | Supply and filling in glass wool 50 mm thickfor packing between inner & outer geyser assembly complete all as specified & directed. |
| 10 | Supply and replacement of old/ rusted and worn out geyser outer cover for 25 litre capacity geyser complete all as specified & directed. |
| 11 | S&F in replacement ofwired PVC connection pipe heavy quality , ISI markedfor geyser size of 15 mm bore with brass nuts and washer,length of 600 mm complete all as specified & directed. |
| 12 | Supply & fixing in replacement stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for unions suitable for size 15mm bore complete all as specified & directed. |
| 13 | Supply & fixing for steel water tubes of size 15mm bore (medium grade) galvanvised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls including taking out existing GI tubing bore with all fittingscomplete all as specified & directed. |
| 14 | Supply & fixing for steel water tubes of size 20mm bore (medium grade) galvanvised with all fittings and fixed complete to walls and ceiling or laid in floors/ concealed in walls including taking out existing GI tubing bore with all fittingscomplete all as specified & directed. |
| 15 | Supply and fix for non return valve(NRV)GM alloy screwedof size 15 mm bore complete all as specified & directed. |
| 16 | S&Ffor\" L\"hook fastener size 10 mm dia and 10 cm long with connected washers fixing on wall for hanging of geysercomplete all as specified & directed. |
| 17 | Taking down geyser from the existing position and refixing thereafter alongwith necessary plumbing and electricfitting with fixture complete all as specified & directed.Note:- Rates of spare shall be included in quoted rates |
| 18 | Taking down Solar water heater of capacity 100 ltrs/200 ltrs/500 ltrsand repair /maint of unserviceable items and re-fixed in original position (Spare\"s shall be measured and paid separately under respective item of schedule) complete all as specified & directed.Note :- Servicing/Cleaning of steel tank of solar water heater shall be included in quoted rates. |
| 19 | Supply and fixing in replacement of solar evacuated tube of solar water heatersuitable for 100/200/300/ 500 LPDcomplete with washer etc complete all as specified & directed. |
| 20 | Supply and fixingin replacement of heating element INCOLOY type upto 5 KWfor solar water heater as per sample ISI Marked with rubber gasket of suitable Size complete all as specified & directed. |
| 21 | Supply and fixingin replacement of thermostate ISI marked suitable for solar heater complete all as specified & directed. |
| 22 | Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 300 ltrs pre insulated hot water storage tank with stand (inner tankSS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank ; complete all as specified & directed. |
| 23 | M&L for taking down andreplacement ofgun metal globe valve 15 mm bore complete all as specified & directed. |
| 24 | M&L for taking down andreplacement gun metal globe valve size 20 mm bore all as specifed and as directed |
| 25 | M&L in replacementfor galvanised steel tubing 15mm bore medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling/roof etc complete all as specified and directed . |
| 26 | M&L in replacementfor galvanised steel tubing 20 mm bore medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling/roof etc complete all as specified and directed . |
| 27 | Supply & fixing in replacement bib tap cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule15mm bore complete all as specified & directed. |
| 28 | Supply & fixing in replacement stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for unions suitable for size 15mm bore complete all as specified & directed. |
| 29 | S&F for switch pianotype (PT), 15 Amps, 240 Volt AC single pole, one way complete all as specified & directed. |
| 30 | M&L for Socket outlet multi purpose 2 in 1, 6 pin, 5 & 15 Amps, flush type complete all as specified & directed. |
| 31 | S&F forPVC insulatedFRLS multistranded copper wire suitable for1100 volts grade of size 1.5sqmm, 3 core complete all as specified & directed. |
| 32 | S& F forPVC insulated & unsheathed multistranded copper conductor cable suitable for1100 volts grade of size 2.5 sqmm, 3 core in 20 mm boreflexible PVC conduitwith holding clip complete all as specified & directed. |
| 33 | S & F forPVC insulated & unsheathed stranded copper conductor cable 1100 volts grade of size 4.0 sqmm, 3 core in 25 mm boreflexible/rigid pvc conduitcomplete all as specified & directed. |
| 34 | S& F foraluminum lugfor cable termination6 sq mm to 35 sqmm complete all as specified & directed. |
| 35 | Taking down Exhaust fan 250- 380 mm sweep of any make/ model and repairing by removing burnt / heatedwinding from stater and rewinding the stater coils with super enamelled copper wire of suitable size including providing insulation material, varnishing, painting and provision of cotton tape, re-assembling and testing including replacement of spring washer and two core flexible wire of size 1.5 sq mm with copper conductor of suitable length from fan terminal to ceiling rose and refixing insame orother position as directed after painting of the body of exhaust fan complete all as specified and directed. |
| 36 | All as per item No. 26here-in-before but exhaust fan of sweep 450mm complete all as specified and directed. |
| 37 | Supply and replacementof unserviceable ball bearings of exhaust fan 250 -450 mm sweep complete all as specified and directed.. |
| 38 | Supply and replacement of gun metal bush for exhaust fan 250 -450 mm sweepincluding lath work etc complete all as specified and directed. |
| 39 | Supply and replacement of capacitor3.15 mfd complete all as specified & directed. |
| 40 | Supply and replacement of Capacitor 4.0 mfd complete all as specified & directed. |
| 41 | Supply and replacement of rubber reel set with nuts, bolt and washer etc. complete all as specified and directed. |
| 42 | Supply and fixing in replacement oflight grade down rod for ceiling fan size 600 mm long with connectedhook, nut bolt washer complete all as specified & directed. |
| 43 | Supply and fixing in replacement with new louvershutterfor exhaust fan as per existing size or type complete all as specified and directed. |
| 44 | Supply and fixingin replacement of metal fan blade forExhaust Fan sweep size 250-450 mm duly screwed with spring washers of make as per existing, complete all as specified and directed. |
| 45 | S&F in replacement of Exhaust fan (sweep size 250-450 mm) mountinglegs with ring of any size &type with connected nut, bolts, washers, including grouting work & match the distrubed surface with exsiting, complete all as specified and directed. |
| 46 | S& F in repalcement of two way DB box with single pole MCB 6 to 32 amp rating for solar water heater fixing in wall as match the distrubed surface with existing complete all as specified & directed. |
| 47 | Supply andfix in replacement ofplug top 15 amps three pin complete all as specified & directed. |
| 48 | Supply andfix in replacement of of plug top 5 amps three pin complete all as specified and directed . |
| 49 | M&L for Taking down ceiling fan for repair of any make/ modelof sweep 1200/1400 mm by removing burnt / heated winding from stator and rewinding the stator coils with super enamelled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer, bearing, bush, capacitor of 3.15 mfd and two core flexiblewire of size 1.5 sq mm with copper conductor of suitableupto 1.50 m length from fan terminal to ceiling rose & refiixing the same after repair complete all as specified & directed. |
| 50 | Supplying and replacementof unserviceable ball bearings of ceiling fan any sweep complete all as specified and directed. |
| 51 | Supply and replacement of condenser 2.5/3.15 mfd oil filled type complete all as specified & directed. |
| 52 | S&Fin replacementof electronic fan regulator 230 volts suitable for ceiling fan of size 1200mm/1400mmsweep complete all as specified and directed. |
| 53 | Supply and fixing in replacement of High Air Delivery 490 CMH, Speed:-1350 RPMPVC Exhaust Fan Motor 35 watt , 220 Volt single phase sweep size200 mm complete all as specified & directed. |
| 54 | Material and Labour for painting the outer surface of geysers of 25/35/50 itrs as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty writing \" MES GE Ludhiana\" etc and refixing the geyser in position including water/electric connection and testing complete all as specified & directed. |
| 55 | Material and Labour for Brazing / welding of innertank at leaking spots up to five leakage of geyser of capacity 25/35/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified & directed. |
| 56 | Supply and fixingin replacement of brass chromium plated angle valve, fancy typeof size 15mm dia screwed down for high pressure, ; Complete all as specified and directed. |
| 57 | Supplyand fixing of solar flat platecollector type with heat exchanger of500 ltrs per day capacity and size of collector 2112 X1035 X 101mm including necessary fittings complete all as specified & directed. |
| 58 | M& L for Taking down wall mounted fan for repair of any make/ modelof sweep upto 450 mm by removing burnt / heated winding and rewinding with super enamelled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer, bearing, bush, and two core flexiblewire of size 1.5 sq mm with copper conductor of suitableupto 1.50 m length& refiixing the same after repair complete all as specified. |
| 59 | Supply onlySocket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified & directed. |
| 60 | Supply and fix in replacement of switch 15 Amps flush type complete all as specified & directed. |
| 61 | M & L in replacement sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 1.5 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed Note : 2 runs of 1.5 sqmm, 1 run of 1.5 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length ccomplete all as specified & directed. |
| 62 | Supplying and fixing 1100 volts grade PVC heavy duty cable 6 sqmm suspension wire (stranded conductor) PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart ,one twin core cable flat or circular complete all as specified & directed. |
| 63 | Supplying and fixing 1100 volts grade PVC heavy duty cable 10 sqmm suspension wire (stranded conductor) PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart, one twin core cable flat or circular complete all as specified & directed. |
| 64 | M&L for sheet metal DB for MCBs, SPN, 4 ways, double door,singal phase, IP-43 company painted with 200 Amps rated bus bar, neutral bar/ connectors, each bar/ connectors, prewired complete with suitable copper conductor wire, PVC insulated, FRLS type with suitable copper thimbles, lugs etc complete all as specified & directed. |
| 65 | All as per srl item No. 26 here-in-before but of size 8 ways complete all as specified & directed.Note forsrl item 52 & 53 :- MCB,sSPN & SPshall be measured and paid for separately. |
| 66 | Supply and fixing in replacement MCB SP 06 to 32Amp 240 V, 10 KA, \"C\" Series complete all as specified & directed. |
| 67 | Supply and fixing in replacement MCB SPN 32 Amp 240 V, 10 KA, \"C\" Series complete all as specified & directed. |
| 68 | Supply and replacement of Plug type bib taps,cast iron, screwed for iron pipe and fixed 15mm dia complete all as specified & directed. |
| 69 | Supply and fixing in replacement of PVC flexible copper cable 1.5 sqmm 3 core complete all as specified & directed. |
| 70 | S&F FRLS PVC insulated & unsheathed stranded copper conductor single core cable 1100 volts grade of size 2.5 sqmm conforming to IS 694 complete all specified and directed. |
| 71 | M&L in replacement sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4.0 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc including taking down all as specified and as directed Note : 2 runs of 4 sqmm, 1 run of 4.0 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length complete all specified and directed. |
| 72 | M&L in replacement sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc including taking down all as specified and as directed Note : 2 runs of 6 sqmm, 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length complete all specified and directed. |
| 73 | S&Ffor metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Ampsincluding removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed. |
| 74 | M& L for earthing complete with & including galvanized MS earth plate of size600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level,with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanizediron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 4 mm diaduly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provnof the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate andGI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation& earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6type C-1 as inearth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mmcomplete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department. |