}

Tender For Provision Of Trg Shed And Pt Shed At Src Fatehgarh., fatehgarh-Uttar Pradesh

Tender Notice

51419583
Corrigendum : Tender For Provision Of Trg Shed And Pt Shed At Src Fatehgarh.
Tender
Indian
Uttar Pradesh
Fatehgarh
06-11-2025

Tender Details

Tender For Provision Of Trg Shed And Pt Shed At Src Fatehgarh.; 1 Design, fabrication and erecting, Pre-engineered building (PEB) structure for Provision ofTraining Shed of size 12 m x36m with minimum 3.6m clear height i.efrom top of FFL to bottom of truss etc and 0.45 mm base metal thickness, pre-painted camouflage pattern 0.5 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium Zinc alloy coated withpainted having tensile strength of 550 Mpa as in roofing fixed with self-tapping screws and supply & fix for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.60mm thick (AZ not less than 150) ofcolour as directed having tensile strength of 550Mpa as in ridge/vally gutter roof covering/cladding to wall, fixed with self tapping screw, (factory made valley gutter shape and size directed by Engineer-in-charge) include for the supply of bolts, gutter bolts, screws, washers, pipe nails, distance pieces, plugs, holder-bats (for pipes) and all jointing materials and also for all necessary cutting of gutters and pipes, drilling for bolts and jointing and fixing in position, down take pipe, downspout pipes and metal clamps,with brick work complete as shown on drawing, specificationand as per Tender documents all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified: -(i) Frame type Pre-Engineered Building (ii) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2.(iii) PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate incl form work upto plinth level.(iv) RCC work M-30 in footing with plinth beam as per approved design and as per IS:9103.(v) All necessary civil work for setting of the super structure layout, excavation, back filling, RCC foundation/ foundation work, Plinth beam, RCC four sitting platform in two sheds only and as shown on drg incl 16mm to 18mm thick pre-polished Udaipur green marble shall be provided on tread and riser over 20 mm thick screed bed in CM (1:3) incl bullnose finish.(vi) Kotastone flooring , Plinth protection incl saucer drain, brick step, Plaster, SS railing complete civil work as specified.Note : (i) Design parameters of PEB structure shall be as per PS clause No.24 to 30 ofTender.(ii) Following items mentioned under srl no 1.01 to1.08 here-in after shall also be included in lump sum rate quoted against Srl item No 1.00 of BOQ. 2 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 3 Purlins and side girt members are galvanized with zinc coating of Z 275 gm/sqm shall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 4 Permanently colour coated (camouflage patteren) high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 5 Kota stone flooring shall be 18 mm to 20 mm thick machine cut and and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm. Kota stone slab shall be laid over 20mm thick screed in CM (1:3) over 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shall achieve mirror finish surface. 6 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as inplinth protection including saucer drain as specified. 7 75 mm thick PCC 1:3:6 type C-1 as inplinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be providedand same shall be filled with bitumen mastic (1:3) 8 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 9 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 10 Site Clearance in soft/loose soil complete all as specified and directed. 11 Surface excavationaveraging 15 cm deep and getting outin Soft/loose Soil complete all as specified and directed. 12 M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in lean concrete etc complete all as specifiedand directed 13 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.etc complete all as specified and directed. 14 M & L PCC 1:2:4 type B-1 (using 20mm graded stone aggt) as in kerb stone/Coping etc complete all as specified and directed 15 Removing excavated material (soil) to a distance exceeding 50m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed . 16 S&F rolled sections as in framing for cladding, gazing, frame/chowkhat and the like fixed with angle cleats and connecting plates, etc, conforming to Fe 415-W (Gde-E-165) quality A complete all as specified and directed. 17 S&F Mild steel, plain, black sheet1.00mm thick in wall cladding, steel gates and similar work, cut to size, holes puched; including round headed screws, cloutnails or rivets and fixed to wood or steel flaming with plain 40mm lap joints with riveted or welded seams, including bending or turning up mitred angles, etc as required complete all as specified and directed. 18 Excavating in trenches not exc 1.5m wide and not exceeding 1.50 m in depth, for foundations, wells cesspit, manholes, drain, laying of pipes & cable etc and getting out in soft/loose complete all as specified and directed. 19 M & L PCC 1:3:6 Type C-2 (using 40 mm graded agg) as in surface channel and drain bad complete all as specified and directed. 20 Returning, filling in including spreading, leveving, watering and well ramming in layers n exc 25cm in soft/loose soil complete all as specified and directed. 21 Removing excavated material exc 250 m but not exc 500 m and depositing where directed complete all as specified and directed. 22 M & L precast reinforced cement concreteM-25 grade as in cover slabof thickness 130 mm including reinforement as per manufacture instruction completeall as specified and directed. 23 M & L precast reinforced cement concrete M-25 grade as in U shape drain ofsize 450mm width and av depth 600mm as per site conditionand wallthickness 80 mmincluding reinforement as per manufacture instructioncompleteall as specified and directed. 24 Cutting existing CI/GI pipe line 40 mm dia for insertion of tee of size 80 x 80 x 40 mm for branch connection including excavation and earth work complete all as specified and directed. 25 Cutting existing CI/GI pipe line 40 mm dia for insertion of tee of size 40 x 40 x 25 mm for branch connection including excavation and earth work complete all as specified and directed. 26 M&L for steel water tubing 40 mm bore with screwed & socket joints, medium grade, galvanized (includ- ing short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches complete as per IS-1239 part-II all as specified and directed. 27 M&L for steel water tubing 25 mm bore with screwed & socket joints, medium grade, galvanized (includ- ing short lengths) with and includ- ing all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches complete as per IS-1239 part-II all as specified and directed. 28 S&F gun metal gate glove or gate valves, with Iron wheel head, screwed both ends for iron pipe ISI marked of 25mm bore GI pipe complete all as specified and directed. 29 M&L for steel water tubing 40 mm bore with screwed & socket joints, light grade, galvanized (includ- ing short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid across road, in trenches or across PCC drain, along electric pole complete as per IS-1239 part-II all as specified and directed. 30 Supply & laying sand cushioning to under ground cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured and paid. 31 Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core including dismantaling complete all as specified and directed. 32 Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core complete all as specified and directed. 33 M&L for DK thermoplastic cable junction boxes IP-66 with matric knockoutsfor calbe entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/6 Sqmm 2 core and fixed to the PSC/Steel poles by means of suitable size of clamps withnut and bolts with suitable busbarincludingall accessories.complete all as specified and directed. 34 Supply and fixing LED street light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of40 mm dia GIlightgrade pipe, 1.20 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 1.5 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. 35 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e)Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 36 Supplying & Laying reinforced pre cast flat ISI marked concrete cable protection cover of class LV Type 1 of flat size 250 mm x 150mm x 40mm , factory made, ISI marked, embossed with LT ELECTRIC on the top surface complete all as specified and directed 37 Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level ) with top edge of the plate not less than 1.50m below normal ground level , connected to and including galvanized steel strip 25x4 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40 mm pipemedium grade for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed.NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be re-done at without any extra cost by contractor. 38 M&L for surface mounted point wiring completeforOne LED light/Building Security Light/Industrial Wall Mounting Fan/ controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm(nominal area) ISI marked, 1100 V grade multi-stranded copper conductor single core including ISI marked not less than 20 mm dia PVC rigid conduit medium grade fixed on surface/truss including pressed MS/GI sunken boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- Conduit shall be fixed on surface/ truss with necessary saddles where concelling of conduit is not fessible without any extra cost 39 Ditto all as item No.30 above but for 5 pin 6 Amp socket outlet on independent board complete 40 M&L for concealed/surface mounted point wiring completefor16 Amp Switch controlledwith PVC insulated and unsheathed FRLSH cable 2.5 Sqmm(nominal area) ISI marked, 1100 V grade multi-stranded copper conductor single core including ISI marked not less than 20 mm dia PVC rigid conduit medium grade fixed concealed in wall /truss/surface including pressed MS/GI sunken boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- Conduit shall be fixed on surface/ truss with necessary saddles where concelling of conduit is not fessible without any extra cost 41 Supply and fixing switch piano flush type single pole one way 6 Amp complete all as specified and directed. 42 Supply and fixing switch piano flush type single pole one way 16 Amp complete all as specified and directed. 43 Supply and fixing socket outlet 3 pin 6 Amppiano flush type complete all as specified and directed. 44 Supply and fixing socket outlet 3 pin 16 Amppiano flush type complete all as specified and directed. 45 S & F forCeiling rose PVC polycarbonate isolated body 62.5 X 25mm with three terminal as per relevant IS complete as specified and directed. 46 S&F 20W LED batten surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block & fixing arrangments for fixing the light fitting complete all as specified and directed. 47 S&F 35W LED building security lightfitting with Aliminium pressure die cast housing high purity PC fensel diffuser with silicon gasket for IP-66 protection, in built electronic driver duly wired upto terminal block & fixing arrangments for fixing the light fitting complete all as specified and directed. 48 S & F MCB DB vertical type 4-way VTPN sheet metal enclosure 415V with 200 Amp fully insulated starndard copper Busbar for each phase & sourrounded with neutral Bars & two common neutral bar, two earth bar incl cable ties for cable management suitable for housing MCCB/TPN 415 V as incommer IP-54 protection with metal doors all enclosed on strandard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate complete all as specified & directed. 49 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 12 - way ISI marked all as specified and directed . 50 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 08 - way ISI marked all as specified and directed . 51 S&F MCB SPN 32 Amps B series,10 KA 240 Volts ,AC ISI marked all as specified and directed . 52 S & F MCB SP 6 to 32 Amp rating 240V, 10 KA C curve & curent carrying capacity in the MCB DB complete with connection testing and commissioningcomplete all as specified & directed 53 S&F MCCB 415 Volts AC, with 63 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified & directed. 54 S & F BLDC type Air circulator wall mounting fan 750 mm Sweep, single phase 230V AC, 1440 RPM, air delivery CMM, power consumption 250 watt, with string, 3 speed choice colour mate, 5 star rating & ISI marked alongwith complete accessories and connecting up the fan to ceiling rose incl PVC insulated 3 core 23/0.0076 copper cable & suitable size of flexible cord with plug top from ceiling rose to w/m fan motor not less than 0.5 m long for connection complete all as specified. Note:- Necessary Fan mounting arragnement on pillar /wall is deemed to include quoted rate. 55 M&L for submain wiring with two single core 4 sqmm copper conductor FRLSH, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified.Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 56 M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. belowground level connecting to galvanised earth lead wire 4.0 mm diaas earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixingwith 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified complete all as directed. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed .

Key Value

Document Fees
INR 2000 /-
EMD
INR 294500.0 /-
Tender Value
INR 2.19 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail