| 1 | Taking down carefully aluminium/ copper wiring / power point wiring (light, fan, call bell socket or power circuits) completeand making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiringincl GI/ MS brandedsunken boxes suitable for normal/modular concealedon walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular/normal typeswitches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch |
| 3 | All as per item No. 2 above but forOne fan point controlled by one switch / regulator |
| 4 | All as per item No. 2 above but forOne light point controlled by 2 way switch |
| 5 | All as per item No. 2 above but forOne 3 pin socket out let 5 Amps on independent board |
| 6 | All as per item No. 2 above but forOne bell / buzzer point controlled by bell push |
| 7 | All as per item No. 2 above but forOne 3 pin socket out let 5 A on same board |
| 8 | All as per item No 2 but concealed wiring drawn through existing PVC conduit.One light point controlled by one switch |
| 9 | All as per item No. 8 above but forOne fan / Exhaust point controlled by one switch / regulator |
| 10 | All as per item No. 8 above but forOne light point controlled by 2 way switch |
| 11 | All as per item No. 8 above but forOne 3 pin socket out let 5 Amps on independent board |
| 12 | All as per item No. 8 above but forOne bell / buzzer point controlled by bell push |
| 13 | All as per item No. 8 above but forOne 3 pin socket out let 5 A on same board |
| 14 | M&L point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI markedincl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 15 | M&L point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & CapingISI marked incl accessories surface type wiringincl 1.6 mm thick GI/MS sunken boxes concealedon walls includinglaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 16 | All as per item No. 15 above but forOne fan point controlled by one switch / regulator |
| 17 | All as per item No. 15 above but forOne light point controlled by 2 way switch |
| 18 | All as per item No. 15 above but forOne 3 pin socket out let 5 Amps on independent board |
| 19 | All as per item No. 15 above but forOne bell / buzzer point controlled by bell push |
| 20 | All as per item No. 15 above but forOne 3 pin socket out let 5 A on same board |
| 21 | M&L point wiringcomplete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI markedincl accessories concealedtype run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 22 | M&L point wiring completewith 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing capingISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 22 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in unit rate quated . |
| 23 | M&L for groove cutting in wall/floor and making good of distrubed wall/floor, painting of existing colour all as specified and directed by Engineer -in-Charge. |
| 24 | S&F LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminiumhousing & integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No. BCLAB20 W LED P or equivalent Makes & model of CA |
| 25 | S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic covercomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10W WH or equivalent Makes &model of CA |
| 26 | S&F 2\" x 2\" RecessmountedLED Luminaire36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L LED WH GX MT or equivalent Makes & model of CA |
| 27 | S&F 2, x 2, Surface mountedLED Luminaire36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L LED GX CW or equivalent Makes & model of CA |
| 28 | Supply and fix Slim surface mounted round LED down lighterof 12wattaluminium die cast body with premium diffuser to ensure glare free & even distribution of light including taking down old unsv fitting.Make & Model No: BGSLO SLEEK SURFACE 12 W WH RD LED of BAJAJor equivalent make and model of CA. |
| 29 | Supply and Fix in repair Modular switch 1 way 6A,1 module |
| 30 | Supply and fix in repair Modular switch 1 way 16A, 1 module |
| 31 | Supply and fix in repair Modular switch 2 way 6A,1 module |
| 32 | Supply and Fix in repair Modular Bell push 6A 1 module |
| 33 | Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module |
| 34 | Supply and fix in repair modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 35 | Supply and fix in repair modular type Fan step regulator, 120W - 2 module |
| 36 | S&Fin repair of of Switch piano flush button single pole two way 5 Amps all as specified and as directed. |
| 37 | S&F in repair of Angle holder PVC/polycarbonate type all as specified and as directed |
| 38 | S&Fin repair of switch piano flush type single pole one way 5 Amps |
| 39 | S&Fin repair of switch socket combination5 pin2 in 1, 5 A Flush typeall as specified and asdirected |
| 40 | S&F in repair of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected |
| 41 | S&F in repair of bell push flush type 5A all as specified and as directed . |
| 42 | S&Fin repair ofMCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 43 | S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 44 | S&F in repair ofMCB TPN 415 volts, 10KA \"C\" curve 63 Amps complete all as specified and as directed |
| 45 | S&F in repair ofMCB TPN 415 volts, 10KA \"C\" curve100 Amps complete all as specified and as directed |
| 46 | S&Fin repair of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 47 | S&F in repair of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbaras specified and as directed. |
| 48 | S&Fin repair ofMCB DB TPN 4 way with double door type415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 49 | S&F in repair ofceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 50 | S&Fin repair of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 51 | S&Fin repair ofDing Dong bellAC 230 volts single pole. |
| 52 | Removing of old existing unsv submain wiring and provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 53 | Removing of oldexisting unsv submain wiring and provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 54 | Removing of oldexisting unsv submain wiring and provision of new sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed.Note for item Nos: 52 ot 543 runs of cable and one run of PVC conduit will be measured as unit lengfth for payment. |
| 55 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing complete. |
| 56 | Supply and fixing 30 WLED bldg securitylight fittingwith pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH PO PC SD or equivalent Makes & model of CA. |
| 57 | S&Fin repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paintover a coat of red oxide primer including removing the old existing GIbracket from bldg complete all as specified and directed. |
| 58 | S&Fin repair Bulk Head Fittingsuitable for indoor application of 10 watt,including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. Make & Model No: Bajaj Cat part No: BIBWP 10W LED |
| 59 | S&Fin repair Decorative wall lightfixture made up of polycabonate suitable for indoor application of 9 watt LED lamp B22 base,including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. |
| 60 | S&Fin repair LED Bulbsuitable for indoor application of 9 watt,to fit in Angle Holder or Decorative wall light fixture all as directed. Make & Model No: Havells Cat part No: ADORE LED PLUS 9 W or its equivalent make of CA. |
| 61 | S&F Storage type water heater 25 Ltrs BEE 5 star ratedcomplete incl steel wired pipe for hot/cold water connection for inlet and out let wateretc completeall as specified and directed at site. Make Bajaj. Model No CALENTA 150801 or equivalent make of Venus / Havells) |
| 62 | S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directedMake Bajaj, SABSE TEZZ EE 03. Model No 251120 and equivalent on Havells/CG/ USHA. |
| 63 | S&F Exhaust fansAC single phase 230/ 240 V of size 250/280/300 mm sweep with louvers fixed outside withall accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all as directed. Make :Bajaj cat No : 70002/3, FRESHEE 225/300 mm METALLIC GREY EXHAUST FA or equivalent in Make Havells/CGs/ Orient |
| 64 | S&F in repairPVC Fresh air fan MAXIMA DXI G02 IVORY DOM EX FAN of 150mm sweep 1200/1400 RPM with louver. Make Bajaj 70506- CG or equivalent make ofUsha / Orient / Phillips / Bajaj.IVORY DOM EX FAN |
| 65 | S&F in repairPVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 200/225mm sweep 1200/1400 RPM with louver. Make: Bajaj.70079 or equivalent make of CG / Usha / Orient / Phillips |
| 66 | S&Fin repairPVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 250/300mm sweep 1200/1400 RPM with louver. Make-Bajaj.70049 or equivalent make of CG / Usha / Orient / Phillips |
| 67 | S&F in repair replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps |
| 68 | Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 69 | Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed. |
| 70 | Supply onlyinternal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed. |
| 71 | Supply only heating element of 2 KW rating triangular/round typeas per existing size and type including rubber washers all as specified & as directed. |
| 72 | Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed. |
| 73 | Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size. |
| 74 | Supply only Indicator lamp red and green type square/round. |
| 75 | Supply only Safety valve/high pressure valve / NRV of exisitng type ISI marked. |
| 76 | Supply only PVC insulated Copper cable flexible 3 coreof size 40/0.0076ISI marked. |
| 77 | Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed. |
| 78 | S&F in repairof exhaust fansouterframe for holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or equivalent. |
| 79 | S&F in repairof exhaust fansouterframe for holding exhaust fan motor upto 300/230 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or equivalent. |
| 80 | M&L in repair louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed |
| 81 | M&L in repairlouver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed |
| 82 | M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No incluingtaking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge. |
| 83 | Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 84 | Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 85 | Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan includinggreasing complete all as specified and as directed. |
| 86 | Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed. |
| 87 | Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 88 | Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed. |
| 89 | Supply only PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed. |
| 90 | Supply only Rubber bush with MS bolts, nuts & washers with \"U\" clamps for ceiling fans complete all as specified and as directed. |
| 91 | Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling / re-fixing in its p complete all as specified and as directed. |
| 92 | Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 93 | Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 94 | Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines,preparing the surfaces,filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 95 | Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 96 | Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 97 | M&L extension of down rod for ceiling fanupto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed. |
| 98 | S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |