| 1 | Repair & maintenance of geyser of 25/50 Ltrs capacity existing make, carefully by disconnecting electric & water connection, dismantling and inspecting all the parts, for its serviceability, cleaning of serviceable parts i.e. heating element, base assy, connecting lead, thermostat, electrical contact, electrical wiring, indicators, safety valves, vacum control/pressure reducing valve, PVC connection, inner tank, outer tank, glass wool insulation etc and refixing the same after replacement of unserviceable parts matching with existingmake and sizes as mentioned above, re-assembling, reconnecting, refixing with electrical & water connections and testing complete all as specified and directed. Note : (i) The defective parts to be replaced shall be measured and paid separately under relevant item ofBOQ. (ii)Cost of minor items i.e. screws, nut & bolts, all T&P etc. shall be deemed to be included in quoted rates. |
| 2 | S&F in repairs Geyser Stainless steel connection pipe 15 mm borewith nuts, rubber washers etc complete of length450 mm long matching with existing complete all as specified and directed. |
| 3 | S&F in repairs geyser element 2.0 KW of exisitng make of geyser with gasket, nuts, bolts suitable for the existingtriangular/round shapes complete all as specified and directed. |
| 4 | S&F in repairs geyser element 1.5 KW of exisitng make of geyser with gasket, nuts, bolts suitable for the existingtriangular/round shapes complete all as specified and directed. |
| 5 | S&F in reapirsthermostat of exisitng make suitable for existinggeyser capacity of50/25 Ltrs complete all as specified and directed. |
| 6 | S&F in repair geyser safety multifunction valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified and directed. |
| 7 | M&L for painting of geysers of any cap 25/50 Ltr with 2 coats of synthetic enamelled paint after scraping the existing old painted surface complete all as specified and directed. |
| 8 | S&F in repair geyser anchor fastener bolts of min length 100mm, dia 10mm for geysers for thecapacity of geyser complete all as specified and directed. |
| 9 | Supply, installation, testing & commissioning of heater water storage type electric geyser 25 litre capacity with BEE 5 star rating (minimum) and ABS body, porcelain enamel glass lined inner tank including fixing arrangement with providing including suitable capacity flexible cable 3 core with 3-pin plug of 16 amp capacity maximum 2 mtr length, SS connection pipe of size 15 mm dia and 450mm length for Hot & Cold water, including chromium plated brass nuts and fixing on walls with and including all necessary fitting material i.e. Mild steel Bolts (Bolts to be grouted), CP brass nuts, Washers, etc complete all as specified and directed. |
| 10 | Supply, installation, testing & commissioning of heater water storage type electric geyser50 litre capacity with BEE 5 star rating (minimum) and ABS body, porcelain enamel glass lined inner tank including fixing arrangement with providing including suitable capacity flexible cable 3 core with 3-pin plug of 16 amp capacity maximum 2 mtr length, SS connection pipe of size 15 mm dia and 450mm length for Hot & Cold water, including chromium plated brass nuts and fixing on walls with and including all necessary fitting material i.e. Mild steel Bolts (Bolts to be grouted), CP brass nuts, Washers, etc complete all as specified and directed. |
| 11 | Supply, installation, testing & commissioning of heater water storage type electric geyser(vertical type)50 litre capacity with BEE 5 star rating (minimum) and ABS body, porcelain enamel glass lined inner tank including fixing arrangement with providing including suitable capacity flexible cable 3 core with 3-pin plug of 16 amp capacity maximum 2 mtr length, SS connection pipe of size 15 mm dia and 450mm length for Hot & Cold water, including chromium plated brass nuts and fixing on walls with and including all necessary fitting material i.e. Mild steel Bolts (Bolts to be grouted), CP brass nuts, Washers, etc complete all as specified and directed. |
| 12 | Repair and servicing ofSolar water heaters of capacities 100 LPD to 300LPD of any make, carrying out the inspection of the all units of solar water heaters thouroghly, trace out the faults, and the repair the same at location or at the work shop etc. by disconnecting and dismantling the defective units, cleaning of all glass, checking solar insolation, direction of rays, cleaning the makeup water tank inlet and outlet connections, membrane etc. replacement of new spare parts, old serviceable parts etc. as required at site and reconnecting, reassembling the same after repair including testing complete all as specified and directed.Note : (i) The Spares parts and jointing material, PCC work etc. required for the repair after opening the solar water heaters shalll be carried out in the presence of JE/Engr-in-charge and the same will measured and paid separately as supply only under relevent items of BOQ. (ii)The fixing of existing serviceable parts shall be included in quoted rates without claiming any extra cost to department. (iii) All the T&P items, transportation shall be arranged by the contractor without claiming any extra cost to department.(iv) The cost of all new fittings PPR/GI Flange Nipple, dead Flange, EPDM Rubber flange gasket, flexiable hose pipe, collector nut bolt required clamp/Washer shall be arrange by the contractor be included in quoted rates without any claiming any extra charges. |
| 13 | Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) based on indirect transfer of heat of capacity 300 LPD with electrical heating back up complete all as specified and directed. |
| 14 | Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD with electrical heating back up complete all as specified and directed. |
| 15 | Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD with electrical heating back up complete all as specified and directed. |
| 16 | S&F in repair 3-layer PPR Polyproplene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings or in floors etc.outer diameter ofpipe 25mm complete all as specified and directed. |
| 17 | S&F in repair PPR Gate valves (brass insert) as per requirement of the site of size 25 mm bore complete all as specified and directed. |
| 18 | S&F in repair Galvanised Ironpipe of dia 32 mm medium grade ,and fixed complete to walls and ceilings or laid in floors, with all fittings such as tees, bend, elbows, sockets reducer, nipples and union complete all as specified and directed. |
| 19 | S&F in repair Gun-metal, globe or gate valves of size 25mm bore, with iron wheel head, screwed both ends for iron pipe and fixed ISI markes complete all as specified and directed. |
| 20 | S&F in repair Gun-metal, globe or gate valves of size 40mm bore, with iron wheel head, screwed both ends for iron pipe and fixed ISI markes complete all as specified and directed. |
| 21 | S&F in repair/replacement existing sub main wiringwith three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area6.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size with proper colour coding and making electric connections, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed. Note:- (i) The quoted rate shall deemed to be inclusive for cutting chases and making good the existingsurfaces for complete concealed wiring. (ii)Three run of6.00 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC conduit of suitable size will be measured as one run. |
| 22 | Welding in repairs exceeding 2.5cm and not exceeding 5 cm in length and thickness of metal to be welded n exc. 6mm thick complete all as specified and directed. Note : (i) All T&P and welding machines,jointing materials shall be included in quoted rates. (ii) The necessary electricity shall be paid bythe contractor on reading of energy meter and tapping shall be provided from main LT panel only and the cable shall be arrange by contractor without claiming any extra charge. |
| 23 | Supply & fix in repair heating element 3.0 KW matching with existing ISI marked complete all as specified and directed. |
| 24 | Supply & fix in repair thermostat for heating element of capacity3.0 KW matching with existing ISI marked complete all as specified and directed. |
| 25 | Supply and fix Solar water heater evacuated tube of size 58 mmx 1800 mm complete all as specified and directed. |
| 26 | Supply and fix Solar water heater Evacuated tube of size 58mmx 2100mmcomplete all as specified and directed. |
| 27 | Supply and fix hose pipe for hot/cold water for Solar system ofsuitable length as existing size with 02 Nos of clamp complete all as specified and as directed. |
| 28 | Cleaning of PVC water tanks of capacity 500 litre including chemical treatment with anti-bacterial agent consisting of following process: -Dewatering the tank withpump, de-silting and removing of left over dirty water up to 10 to 15 mm in the bottom of the tank, cleaning of walls and ceiling with special mechanized high pressure machines which dislodges the layer of dirt, algae, fungus stuck on its surface, usage of scrubbing machines for old stains and cleaning with chemicalswith refixing the cover after cleaning complete all as specified and directed. |
| 29 | All as per Sr. Item No. 28 here in before butPVC water tanks of capacity 1000 litre. |
| 30 | S&F in repair of rotational moulded, multilayer HDPE water storage tank of 500 litres capacity( tripple layer wall construction , Cylindrical vertical with closed top)ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms including refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed |
| 31 | S&F in repair of rotational moulded, multilayer HDPE water storage tank of 1000 litres capacity( tripple layer wall construction , Cylindrical vertical with closed top)ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms including refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed |
| 32 | S&F in repair flat plate collector suitable for solar water heaters of capacity 200/100 LPD matching with existing plate along with connected accessories like MS dead flange,rubber gasket etc complete all as specified and directed. |
| 33 | S&F SS 304 puf insulated solar water storage tank with heat Exchanger of capacity400 LPD with complete fittings all as specified and directed by Engr-in-charge |
| 34 | S&F SS 304 puf insulated solar water storage tank with heat Exchanger of capacity300 LPD with complete fittings all as specified and directed by Engr-in-charge |
| 35 | S&F SS 304 puf insulated solar water storage tank with heat Exchanger of capacity200 LPD with complete fittings all as specified and directed by Engr-in-charge |
| 36 | S&F SS 304 puf insulated solar water storage tank with heat Exchanger of capacity100 LPD with complete fittings all as specified and directed by Engr-in-charge |
| 37 | S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 38 | S&F isulation material of hot water pipewith rockwool and covering the aluminium sheet clading 25 guage for 20mm/25 mm bore GI/PPRsuitable clamps and screw for GI/PPR pipe lines of Solar water heating system complete all as specified and directed. by Engr in Charge. |
| 39 | M&L for cement concrete 1:3:6 Type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-charge. |
| 40 | M&L for point wiring for one 3 pin socket outlet 15 amps on independent board using approved colour coding as per IS (Red, Black and Green for single phase circuits), withmulti-stranded copper FRLSHconductor4 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathedcable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC casing caping, MS sunken box,hylem sheet and accessories on wall/roof/floor etc,ISI marked with valid CML No.(IS-9537-1983 for casing caping and IS:3419:1976 for accessories),including PVC insulated multi-strandard copper conductor 4 Sqmm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following all as specified & directed by Engr-in-Charge. |