| 1 | Lifting of cover from manhole / Gully trap and taking out waste soil, sludge and other foreign materials from gully trap / manhole etc, volume not exc 1.5 cum each, removal of sludges in water sealed container to a distance not exc 50 m and washing manhole / gully trap with adequate quantity of water and refixing the cover in the same location complete all as specified and directed. |
| 2 | Cleaning by rodding/ bamboo split and taking out waste soil sludge and other foreign materials from sewage line any dia removed in sealed container (from WC to onward upto septic tank/soak well) and flushing with water etc complete all as specified and directed. |
| 3 | M&L for pumping out sludge water from manhole of any section for cleaning blocked sewage line, depth of manhole exc 1.20 mtr but not exc 1.80 mtr complete all as specified and directed. |
| 4 | Cleaning ofexisting open or covered drain of any section and depth by removing mud, sludge or foreign materials from existing storm water drain/covered drain, static tanks etc, flushing with adequate quantity of water and removing the sludge to a distance not exc 50 m complete all as specified and directed. |
| 5 | Cleaning of blocked WC by using vaccum pump including opening and refixing/CI cover to bend and branch pieces and finally cleaned with adequate quantity of water complete all as specified and directed. |
| 6 | Demolition and breaking up drain pipes of 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and taking out of trenches if required complete all as specified. |
| 7 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan areain hard / dense soil and getting out complete all as specified and directed. |
| 8 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. |
| 9 | Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. |
| 10 | Supply, laying and jointing 150 mm nominal bore dia DWC(HDPE double wall corrugated), socketed and sewage pipes having6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing matrials etc complete all as specified and directed. |
| 11 | Demolition reinforced cement concrete in slab, beams, staircase, landings, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 12 | S&F TMT bars 6 to 8 mm dia, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 13 | M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain facesand set in cement mortar 1:6 including necessary form, moulds, etc complete all as specified and directed . (Note : Reinforcement shall be measuredand paid separately) |
| 14 | Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as requiredcomplete all as specified and as directed. |
| 15 | Cleaning of CI/PVC SWR pipe of any dia by rodding or with bamboo split including removing and refixing inspection eye door cover in existing position etc complete all as specified and directed. |
| 16 | Dismantling of CI/PVC SWR pipes of 100 bore including fittings jointed in cement mortar from wall/floor/trenches etc and removal of unserviceable pipes complete all as specified and directed. |
| 17 | S&F 100 mm bore cast iron rain (Sand Cast) water pipes fixed to walls in any length with or without ears jointed with cement sand mortar 1:1 complete all as specified and directed. |
| 18 | S&Fcast iron bends of bore 100 mm dia with oval access door as in soil/waste pipe including taking down Old unserviceable one complete all as specified and directed.. |
| 19 | Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed |
| 20 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 21 | Fixing only 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.(Note: Pipe retrive from taking down of rain water pipe here-in-before shall be re-used.) |
| 22 | S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 23 | S & F in repair 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 24 | S & F in repair 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 25 | S & F in repair 110 mm bore, PVC (SWR) vent cowl of any radius complete all as specified and directed. |
| 26 | Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity not exc 250 Ltrs., and from mouths of circulating pipes, etc complete all as specified and directed. |
| 27 | Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 250 Ltrs but not exc 500 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed. |
| 28 | Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 500 Ltrs but not exc 1000 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed. |
| 29 | S & F250 litres capacityrotational moulded polyethylene water storage tanks, double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 30 | S & F500 litres capacityrotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 31 | S & F1000 litres capacityrotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 32 | S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 33 | S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 34 | S&F in repairs 15 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 35 | S&F in repairs gun-metal, globe or gate valves of 25mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 36 | S&F in repairs gun-metal, globe or gate valves of 20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 37 | S&F in repairs gun-metal, globe or gate valves of 15mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 38 | S&F in repairs sinks with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 39 | S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 40 | S&F in repair vitreous China wash hand basin, white,flat back, size 630 x 450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed. |
| 41 | S & F in repairs, vitreous China squatting pan, \"Orissa\"pattern, size 580 x 440 mm white with integral foot rest and \"P\" or \"S\" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed. |
| 42 | S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white,with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 43 | S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain andflushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 44 | S&F in repairs vitreous china urinals, half stall, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 45 | S&F in repair 15mm bore bib tapchorime platefancy type alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified and directed . |
| 46 | S&F in repair 15mm bore stop valves chorime plate alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for unioncomplete all as specified and directed . |
| 47 | S&F in repair, 15 mm dia of bore, fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 48 | S&F in repairs vitreous china urinal partition white of size 310x700 mm with slabs terminating about 40 cm above floor line complete all as specified and directed. |
| 49 | S&F in repairs 32 mm waste fittings, brass chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. . |
| 50 | S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. |
| 51 | S&F in repair, Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube & ABS wall hook including making connections & fixed in position complete in all respect as specified. |
| 52 | S&F in repair, 125 mm size, Brass chromium plated shower rose with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed. |
| 53 | S&F in repair, Sheet Glass Shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 54 | S&F in repair toilet paper holder with flat recessed type stainless steel. Complete all as specified & directed. |
| 55 | S&F in repair, 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers complete all as specified and directed. |
| 56 | S&F in repair 32 mm dia flexible PVC waste pipe for basin, sink & urinal etc complete all as specified and directed. |
| 57 | S&F in repairsgrating round 140 mm size of PTMT(Minimum weight 50gms) complete all as specified and directed. |
| 58 | S&F in repairs of 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 59 | Taking down steel tubing and connections incl cleaning for refixing or removal form site for 15mm bore pipe complete all as specified and directed. |
| 60 | Taking down steel tubing and connections incl cleaning for refixing or removal form site for 20mm bore pipe complete all as specified and directed. |
| 61 | S&F 15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. |
| 62 | S&F 20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. |
| 63 | Refixing15mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.(Note: Pipe retrive from taking down item shall be re-used.) |
| 64 | Refixing20mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed.(Note: Pipe retrive from taking down item shall be re-used.) |
| 65 | Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing), removal servicable tiles to store and rubbish off the premises complete all as specified and directed. |
| 66 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 67 | Material and labour forGlazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4complete all as specified and directed. |
| 68 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish off the premises complete all as specified and directed. |
| 69 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 70 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 71 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 72 | Demolition of cement concrete (un-reinforced) of any description in ground floors and paving\"s not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 73 | M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 74 | Claningof septic tank/soak pit 50 to100 users capacity and filter bed of any depth by removing of sludge, silt, sand or material of any description by dewatering of septic tanks and filter beds including blocking/diversion of inlet line by means of mechanical process for the period and removing the material obtained to outside MD land including cleaning of surface completely with water complete in foul position (Solid material will be measured and dewatering is included in rate) complete all as specified and directed. |
| 75 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed. |
| 76 | M&L for RCC 1:1.5:3 type A1 (Nominal mix) using 20mm graded stone aggregates as in walls, retaining walls, basementwalls, ballast walls and the like;any thickness; above top offootings; including attachedpilaster and buttresses complete all as specified and directed. |
| 77 | M&L forformwork to walls,retaining walls, abutments,parapets and staircase railingsand similar work includingattached pillasters, buttresses,etc.; vertical or to batter flat surface , rough finish complete all as specified and directed. |
| 78 | S&F TMT bars 10 mm dia and over, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 79 | S&F TMT bars 8mm dia and over upto and including 10mm dia as in stirrups, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 80 | M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 81 | M&L for providing precastcement concretelouvres and jallies, 35mm thick of type B0 1:2:4 (using 12.50 mm graded stone aggregate) (mea suredsolid), set in cement mortar 1:4 including all mouldingsbut excluding frame complete all as specified and directed. |
| 82 | Dismantling of fencing posts or struts (steel or R.C.C.) anysection, post embedded in Concrete, brick work,masonry, etc. including taking outembedded portion and making good disturbed ground complete all as specified and directed. |
| 83 | M & L for plain cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 84 | S&F mild steel posts and struts in fencingincluding cutting tops to shapeas directed, drilling holes,notching for wire, etc.; flat ironfillets (for securing wire meshetc.) including all necessarydrilling,boltingor riveting, etc., wind ties forroofincluding securing boltsand similar work conforming toFe-290 Gde E-165 complete all as specified and directed. |
| 85 | S&F mild steelround bars 10mmdia and over, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips conforming toFe-410-W (Gde.E-250)Part- I quality-A orFe 290 (Gde E-165) complete all as specified and directed. |
| 86 | S&F Mild steel screw bolts(machine made) withhexagonal or squareheads at one end andscrewed the other, orscrewed both ends, eachscrewed end to be fittedwith washers and onehexagonal or squarenut, diameter of neck 11 to 15 mm,exc 5cm and n.exc 10 cm long complete all as specified and directed. |
| 87 | Supply and fixing in repair chain link MS galvanisd fencing made of 3.2mm dia wire with and including PVC coating of 1.3mm thickness and mesh size 75mm x 75mm complete all as specified and directed. |
| 88 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and as directed. (Note: Each line wire to be measured.) |
| 89 | S&F mild steelFramed work such as grills,gratings, etc.. with ends of barsshouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors;ladders; framedbalusters; walkways; railings; framework ofwater tanksand similar workconforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 90 | S&F in repair Steel Concentrina coil of super profile of 600 mm dia stress in position hot dipped Galvanised steel wire coated with CLR ante corrosive paint making dimond shape with the help of dove tail clip (18 SWG) the coil fixed with razor wire at points were coil touch the bottom layer wire with help of hog rings(14 SWG) with and including all fittings like fastener, clips, luggs rings etc as approved by GE complete and all as specified and as directed . |
| 91 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern roof covering complete all as directed. |
| 92 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 93 | S&F Pre- painted galvalume aluminum zinc coating Gl based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall of mangalore pattern design, fixed with self tapping screws complete all as specified & directed. |
| 94 | S&F Pre- painted galvalume aluminum zinc coating Gl based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall of mangalore pattern design, fixed with self tapping screws complete all as specified & directed. |
| 95 | M&L for mild steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. |
| 96 | M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesFe410-W Gde- E- 250)quality-A complete all as speicfied and directed. |
| 97 | M & L for preparation newly plastered surfaces of wall (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) and applying two coas of cement base paint over a coat of alkali resistance primer complete all as specified and directed . |
| 98 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 99 | M&L for plain cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and as directed. |
| 100 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 101 | M&L for drilling holes ,dia and depth of hole shall exc. 25mm but n.exc. 40 mm tappered(with standard or gasthread) complete all as specified and directed. |
| 102 | Dismantling Structural steel work including doors, gates, grillsbut excluding framed truss etc complete all as directed. |
| 103 | M&L for Rolled sections as in Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. in cluding cleats, brackets, etc confirming toFe410-W Gde- E- 250)quality-A complete all as speicfied and directed. |
| 104 | Demolition of concrete of any description below or above groundand in any position not otherwise specifically provided including removing the debries to outside of MD land, where directed.for complete all as directed. |
| 105 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 106 | M&L chequered designed cement concrete tiles of size 300mm x 300 mm x 25mm thick, with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed. |
| 107 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 108 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 60 mm thick M-35 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |