| 1 | Supply & Errection of 11 mt. long steel tubular pole with G.I. Bottom designated 410 SP-55 with 1/6 over all length of pole grouted in cement concrete 1:3:6 including the plinthing of pole 30 cm. above the ground level including excavation back filling etc. Rates are including all materials, labour, T & P etc. required for proper completion of work as per direction of E/I. (PSR Rate) |
| 2 | Supply & Fixing of M.S. channel 2.24 mtr long (Top Channel) of size 100x50mm. with M.S. clamp 50x6 mm for DP as per direction of E/I. (PSR Rate) |
| 3 | Supply & Fixing of M.S. channel of 2.24 mtr long size 75x40mm. with M.S. Clamp (PSR Rate) |
| 4 | Supply & Erection of \"D\" clamps of 50mmx6mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respect including painting with aluminium paint. SI No-623/2018. |
| 5 | Supply and Fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. SI No-1109/2018. |
| 6 | S/F of 11 KV pin insulator with G.I. pin on S.T. pole or any where specified including bolts to fasten toe pole cap/cross arm as per direction of E/I (PSR Rate) |
| 7 | S/F disc insulator (70 KN) including gun fitting. (PSR Rate) |
| 8 | S/F of 11 KV TPMO set with required channel, handle switch and insulator etc. complete as per UPCCL norms.(PSR Rate) |
| 9 | S/F of 11 K.V.D.O. fuse set on pole complete as per UPCCL norms. (PSR Rate) |
| 10 | S/F of lighting arrestor for 11 KV complete with base shortd with G.I. strip of size 35x5 mm. complete in all espect as per direction of E/I. (PSR Rate) |
| 11 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I complete in all respects the armouning of the cable shall be property connected with the earth conductor by clamps etc. (S.I. No.501) (i) 240 sq. mm. 3.5 core |
| 12 | S/E of Plain/Pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape & making connection etc. complete in all respects as per direction of E/I. SI No-504(m) (i) 240 sq. mm. |
| 13 | S/F of HT/LT jumpering & connection of double pole & T/F as per direction of E/I. (PSR Rate) |
| 14 | S/Installation, Testing and commissioning of 11/0.433KV copper wound oil fild air cooled T/F with all accessories breather temperature meter etc, complete in all respect as per direction E/I & UPPCL approved. (4 star rating) 63 KVA (PSR Rate) |
| 15 | Supply & erection of stay set 3.5 mt. away from the pole complete with galvanised 19 mm.dia x 1.8o mt. long stay rod, 30h30cmax6.3mm. Anchor plate, thimble stay clamps, stay insulator, 19mm x600mm. Double screw tightner, 7/3,5 mm. G.I, stay wire etc. in 1:3:6 cement concrete complete in all respects. SI No-630/2018 |
| 16 | Painting of ST, pole with 2 coats of aluminium paint over red oxide primer complete in all respect. (S.l. No.634) (S.O.R.-2018) |
| 17 | Making suitable earth of ST. pole with 2.5 mt. long 20 mm. dia earth., rod, 4 S.W.G. G.I. wire including the cost of all material, labour, T&P etc. complete in all respect. (PSR Rate) |
| 18 | S/M of water level earthing of natural & body of T/F shall be done by B class GI pipe 40 mm dia 4 mm thick by boining up to water level 20M Deep & connectiong of M.S. flat 35x5MM etc. complete in all respects as per direction of E/I. (PSR Rate) |
| 19 | Supply and laying of 11 KV 120 sqmm 3 core stranded aluminium conductor XLPE (core liked polyethylene ) insulated PVT bedded Galvanised flat steel strip armoured cable confirming to I.S 7098 (part 11 lettust amendments ) 11 K.v gread at a depth of 900 mm bleo ground leble arounding of cable cable shall be propley caneted with earth conteter by clamb with out brik send cable paas throo cable. SI No-506(F) |
| 20 | Deduct when cable is passed through G.I./M.S. or hume Pipe in road crossing or along the wall. The cost of 100 mm Dia G.I. pipe, hume pipe is to be extra when & where required. SI No-507/2018 |
| 21 | S/F of HDPE (DWC) pipe 120/103.5 MM for road crossing Etc. depth of 750 mm below ground level for L.T cable and 900 mm below ground level for H.T cable carrier as per E/I. (make Dura-line or Reck) (PSR Rate) |