|
| 1 | Material and labour for cleaning debried around of LT panel / feeder piller box. cleaning the internal and external surfaces bus bar, terminal blocks, insulations using dry cloath, vaccum cleaner and blower. Check the tightenes of all electricals cable terminals, bus bar connection and earth connection. Check the serviceability of control switches, indicators, seceloter switches, apply lubricents to hings, locks and moving parts. Check the panel enclosure and gasket are sealed properly and preparation of existing surface of feeder piller box and panel including scraping of old paint and apply two coats of synthetic paint with spray gun of approved shade to ensure a smooth and uniform finish complete all as specified and directed. Note: 1. An electrician is required for checking all the electrical items. |
| 2 | Material and labour for repair to ruted portion of any LT panel / feeder piller box by cutting necessery portion of MS sheet and providing MS Sheet of same thickness (2 / 3.15 mm) base channel, hinges , latches locking supports to doors and busbar support etc. the contractor will provide all safety equipements to the welder like helmet, gloves, fire resistent cloth and safty shoes complete all as specified and directed.Note: 1. Panel detach from all electicals connection.2. MS sheet, hings, latches, welding machine with welding rod and other items inclusive of quoted rate. |
| 3 | Supply and fix in repair of LED indicator in existing panel and taing down unservicable one complete all as specified and directed. |
| 4 | Supply and fix in repair of multi function meter (MFM) to fixed in existing panel and taking down unservicable one complete all as specified and directed. Make: L&T/Havells/Legrand |
| 5 | Supply and fix in repair digital Time switch two module operatedon 110-240Volts, AC,50 Hz, Din rail mounting single channel,including dismantling old one complete all as specified and directedMake: L&T/ Havells/ Legrand/ Indoasian. |
| 6 | Supply and fix in repair replacement power contactor 3 pole, 32 Amps capacity panel mounting with entry terminals,including dismantling old one complete all as specified and directed. Make: Havells/ L& T/ Legrand/ Indoasian |
| 7 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 400 / 320 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 8 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 200 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 9 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 10 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 100 / 63 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 11 | Supply and fixing of onload changeover in existing panel 4 poles, 415 Volts of capacity, rating 400 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 12 | Supply and fixing of onload changeover in existing panel 4 poles, 415 Volts of capacity, rating 250 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 13 | Supply and fixing of onload changeover in ss enclosure 4 poles, 415 Volts of capacity, rating 200 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 14 | Supply and fixing of onload changeover in ss enclosure 4 poles, 415 Volts of capacity, rating 100 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 15 | Supply and fixing of cable end termination heat shrinkable indoor / outdoor type of size 25 to 50 sqmm along with proper lugs complete all as specifie an directed. Note cable thimble are inclusive in quoted rate.Make: 3M / Denson / M- seal / Raychem |
| 16 | Supply and fixing of cable end termination heat shrinkable indoor / outdoor type of size 70 to 150 sqmm along with proper lugs complete all as specifie an directed.Note cable thimble are inclusive in quoted rate.Make: 3M / Denson / M- seal / Raychem |
| 17 | Supply and fixing of cable end termination heat shrinkable indoor / outdoor type of size 185 to 300 sqmm along with proper lugs complete all as specifie an directed.Note cable thimble are inclusive in quoted rate.Make: 3M / Denson / M- seal / Raychem |
| 18 | Supply and fixing of cable end termination heat shrinkable indoor / outdoor type of size 400 to 500 sqmm along with proper lugs complete all as specifie an directed.Note cable thimble are inclusive in quoted rate.Make: 3M / Denson / M- seal / Raychem |
| 19 | Material and labour for supply,install testing and commissioning of LT indoor panel cubicle type of minimum size 1400 mm (Height) x 2000 mm (Breath) x 800 mm (Depth) CPRI approved factory made with dual bus bar chamber consisting of 4 nos of bus bar of capacity 400 Amps and 400 Amps of aluminium bus bar 415 volts including digital multi function meter in input main and dual output digital multi function meter to main and DG out put bus bar chamber connected and Indicating lamps LED type ( R Y B) for input and output including wiring with suitable rated PVC insulated copper conductor wire and panel board shall be made out of 2.0 mm thick CRCA steel, framing with 50x50x6 mm thick MS angle iron and leg of size 400 mm long including locking arrangements detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables andseperate 04 nos terminal block with locking nut of suitable size fixed on a common rail for each MCCB output for cable connection including painting with two coats of super enamelled paint over a coat of metal primer all as specified and directed alongwith comprising of the following accessories :- NOTE: 1.Rate for connection to existing cable are inclusive. 2. PCC for foundation work will measured seperately.(a) MCCB 4 pole 400 Amps, 50 Hz of breaking capacity 36 KA -01 No (Main incomming and outgoing to 320 Amps MCCB and 250 Amps onload changeover)(a) MCCB 4 pole 320 Amps, 50 Hz of breaking capacity 36 KA -01 No (Main incomming from 400 Amps MCCB and main out going to busbar)(a) MCCB 4 pole 200 Amps, 50 Hz of breaking capacity 36 KA -01 No (as main out going to terminal block of size 95 - 240 sqmm with locing nut)(a) MCCB 4 pole 100 Amps, 50 Hz of breaking capacity 25 KA -01 No (as main out going to terminal block of size 35 - 95 sqmm with locing nut)(a) MCCB 4 pole 63 Amps, 50 Hz of breaking capacity 25 KA -01 No (as main out going to terminal block of size 35 - 95 sqmm with locing nut)(a) Onload changeover 250 Amps four pole - 01 No (Main incomming from 400 Amps MCCB, DG incomming and output to busbar)(b) MCCB 4 pole 100 Amps, 50 Hz of breaking capacity 25 KA -02 No (as DG out going to terminal block of size 35 - 95 sqmm with locing nut)(b) MCCB 4 pole 63 AMps,50Hz of breaking capacity 25 KA - 02 Nos(as DG out going to terminal block of size 35 - 95 sqmm with locing nut)(c) MCB SPN 32 AMps,50Hz- 02 Nos(as DG out going)(d) CT operated digital Multi function meter - 03 Nos (e) LED type Indicating lamp (set of 3 ) - 03 set(f) Necessary wiring including material, fixing and connection to existing load. |
| 20 | Material and labourfor PCC 1:4:8 type D2 40 mm graded aggregate for panel foundation etc complete all as specified and directed. |
| 21 | Material and labour forrendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as specifie an directed. |
| 22 | Material and labour for painting of wall of repaired / existing valve pits or in any description with two coats of Distempering walls with distemper dry, white or tinted after preparation of surafces of any description and all as specified and directed |
| 23 | Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 32x6 mmearth streep by means of brazing and earth strip protected by galvanised iron pipe 40 mm bore (Medium grade) for poles / lightening arrestors / GO Switch / transformer / panelincluding connecting to HToverhead linesallas directed including concrete pit in PCC (1:4:8) type CI, precast RCC cover slab of size 30 x 30 x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all as specified and directed.Note: All the excavated remaining area after puting charcol salt in layer filled with paddy soil (best qualit from outside as required) for better hydration and excavated gravelly soil to be removed. A display board of MS sheet thickness 3 mm of size 20 cm x 20 cm painted all through with red colour revited on 32X6 mm strip of length 0.5 mtr written in white colour 1.Type of earthing- Conventional GI Type, 2.Resistance value .............. ohm, 3. Date of test ................ and earthing strip are duly brazed and athe connection end fixed with rust free nut and bolt spring washer on both side all are inclusive in quoted rate |
| 24 | Supply and fix GI Strip 32 x 6 mm burried in an underground/ fixing along wall/ roof etc including with insulators, screw, saddle, for roof conductor /down conductor and connecting with test point properly on existing accn incl dismantlingand taking down unsv one complete all as specified and directed |