| Sl. No. | Item Description |
| 1 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | M&L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished fair and even. complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished fair and evenusing water proofing compound @3% by weight of50 kg cement as per manufacturer instructions. complete all as specified and directed. |
| 4 | M&L for rendering 10 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even. complete all as specified and directed. |
| 5 | M & L for applying three coats of white wash on ceiling incl preparation of new plastered surfaces. complete all as specified and directed. |
| 6 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over 1 mm thick wall care putty. complete all as specified and directed. |
| 7 | M&L for preparation of new surfaces of wall any type applying two coat of exterior emulsion paint over 1 mm thick wall care putty.complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, applying two coats of distemper, oil emulsion white or tinted over and including 1 mm thick wall care putty. complete all as specified and directed. |
| 9 | M&L for preparation of old surfaces of ceiling and applying two coats of whitewash on ceiling surfaces. complete all as specified and directed. |
| 10 | M&L for preparation of old treated wooden surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed. |
| 11 | All as per item No 10 above but on steel surface. complete all as specified and directed. |
| 12 | M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and applying two coat of exterior emulsion paint over 1 mm thick putty wall care. complete all as specified and directed. |
| 13 | Dismantling brick/ concret tiles any size etc incl existing roof treatment of any thickness. complete all as specified and directed. |
| 14 | Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof). complete all as specified and directed. |
| 15 | Removing building materials etc. to a distance of 1000 m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination. complete all as specified and directed. |
| 16 | M&L for complete removal of existing roof treatment (tar felt of any thickness) at any height of the building and cleaning the roof thoroughly with wire brushes and brooms to remove all loose particles and re removing the debris out side MoD land. complete all as specified and directed. |
| 17 | M&L for 25 mm thick avg PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as directed including finished surface even and fair. complete all as specified and directed. |
| 18 | M&L forPCC 1:2:4 type B0 (using 12.5 mm grd stone agg) as in coping, coving and levelling as required finishing the surface fair & even. complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with @ 200mlliquid water proofing compound by 50Kg weight of cement (1 bag) as per manufacturerrs instruction inclduing finishing surfaces even and fair. complete all as specified and directed. (WPC shall be measured and paid separately).(Note: WPC will be measured and paid separately). |
| 20 | Cleaning the roof surfcae from dust /dirt and any other foreign materials and applying a coat of bituminius primer @ 0.40 liters per square meter uniformity after the surfaces fully dried. complete all as specified and directed. |
| 21 | M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm. complete all as specified and directed. |
| 22 | M & L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer. complete all as specified and directed. |
| 23 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and loped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 oarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, ncludingrubbing and polishing of the surface upto 3 cuts complete, including providing skirting in the same manner. complete all as specified and directed. |
| 24 | Supply only Integral waterproofing compound. complete all as specified and directed. |
| 25 | Supply only liquid water proofing compound. complete all as specified and directed. |
| 26 | M&L for cutting out cracks to V section in existing roofsor terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight).complete all as specified and directed. |
| 27 | Demolition to reinforced cement concrete of roofs, floors (other than ground floors )beams staircases,landing,chajjas, tank and similar suspended work.complete all as specified and directed. |
| 28 | S&F in Rotational moulded polythenewater storage tanks tripple layer hoisted and fixed in position 1000ltrs capacity includin GI union, checked nut and 20 mm PTMT float Valve, complete all as specified and directed. |
| 29 | S&F in Rotational moulded polythenewater storage tanks tripple layer hoisted and fixed in position 500ltrs capacity includingGI union, checked nut and 20 mm PTMT float Valve,complete all as specified and directed including Dismantling of old PVC tank and removing to store. |
| 30 | S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed. complete all as specified and directed. |
| 31 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames). complete all as specified and directed. |
| 32 | Taking down chowkats with shutters exceeding 1.5 Sqm but n exc 4.00 Sqm each (without taking off shutters from the frames). complete all as specified and directed. |
| 33 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 34 | S&F in Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm sizecomprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately. |
| 35 | S&F for 150mm SS handles, cast type, complete all as specified and directed. |
| 36 | S&F for 200mm SS barrel tower bolts of extruded section and fixed. complete all as specified and directed. |
| 37 | S&F for 100 mm long SS butt hinges, medium weight, complete all as specified and directed. |
| 38 | S&F for Aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) frame forwindows, csw, ventilatorwith one or more rebates joining cleat for fixing etc complete all as specified including concealed type lock for all three shutters, all as specified and directed. |
| 39 | M&L for Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings for each leaf such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete as per requirement and direction by Engr-in-charge complete all as specified and directed. |
| 40 | S&F forStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesetc. complete all as specified and directed. |
| 41 | S & Ffor 5.5 mm Sheet glass, ordinary qualityin square notexc 0.5 sq.m in each pane. complete all as specified and directed. |
| 42 | S & F for 5.5 mm thick Frosted glass ordinary quality typein squares in n exc 0.5 sq.m in each pane. complete all as specified and directed. |
| 43 | M&L for repair to chajja upto height of bldg 9.00 mtr, area not exc 1.00 Sqm with 15mm thick in cement mortar 1:4 on faces concrete surfaces, finished fair and even incl benching with PCC 1:2:4 using 12.5 mm aggregate using water proofing compound @ 3% by weight of50 kg cement as per manufacturer instructions. complete all as specified and directed. (Note: water proofing compound shall be measured and paid seperately under respective item). |
| 44 | Demolition of brickwork built in cement or cement lime mortar. complete all as specified and directed. |
| 45 | M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6. complete all as specified and directed. |
| 46 | M&L for brick work with sub class B brick straight or curved on plan exc 6 m mean radius built in CM 1: 6, complete all as specified and directed. (Except brick) |
| 47 | M&L for brick work with sub class \"B\"bricks straight or curved on plan to any radius half brick thick wall built in CM (1: 4). complete all as specified and directed. |
| 48 | Dismantling of floor, hearth or wall tilingincluding cement mortar bedding (but not backing).complete all as specified and directed. |
| 49 | M&L forNon Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6). complete all as specified and directed. |
| 50 | M&L for Glazed ceramic coloured tiles in vertical surface 450x 300x7 mmthick tiles set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. (1st quality/Premium Quality). complete all as specified and directed. |
| 51 | M&L forNon Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6). complete all as specified and directed. |
| 52 | M&L forNon Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm ,in skirting dado set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 10 mm thick rendering in CM (1:4). complete all as specified and directed. |
| 53 | Demolition of PCC in ground floor n.exc15cm thickness below or above ground level.complete all as specified and directed. |
| 54 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor finishes etc. complete all as specified and directed. |
| 55 | M&L for sunken portion incl demolition of existing PCC,WC,P/S Trap and removing the material out side MD land.& (a)preparation of RCC surface of sunken slab (floor) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned. |
| 56 | M&L for taking down cement plaster incl tile etc and removing the material out side MD land.&(a)preparation of RCC surface of sunken slab (side) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned |
| 57 | M& L for cement concrete type E2 1:5:10 (40mm graded stone aggregate) as lean concrete in filling / Mass concrete. complete all as specified and directed. |
| 58 | S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap and its fixing set. complete all as specified and directed. |
| 59 | Supply and fixing (in Repair) vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe)and P or S trap including connection to drain (or outgoing pipe) and to flushing pipe anti-syphonage pipe etc complete all as specified and directed. including plastic water closet seat closed pattern with flat bottom and cover and mild steel chromiunm plated or aluminum hinging device. |
| 60 | S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set. complete all as specified and directed. |
| 61 | S & F in repair Vitreous China bowl urinal flat back type size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete incl providing and fixing plugs,bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and incl 60 mm long brass screws,pointing around urinalback in cement, fixing flush pipe. complete all as specified and directed. |
| 62 | Form work (rough finished flat ) to soffits of suspended slab such as roof slabetc not exceeding 200 mm thick. complete all asspecified and as directed. |
| 63 | M & L for RCC 1:2:4 type B1,using 20 mm graded stone aggregate a in slab supported on walls, beams, columns and inany thickness as in shelves and like. complete all as specified and directed. |
| 64 | M&L for steel reinforcement of TMT bars 10 mm dia and over cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips. complete all as specified and directed. |
| 65 | M&L for Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like over 20 mm thick cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed. |
| 66 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc. complete all as specified and directed. |
| 67 | S&F in repair Wash hand basin under counter with fixing accessaries set size 480x370x200 mm shape rectangular Cat No : CNS-WHT-701 of Jaquar or equivalent as approved by Engr-in-charge. |
| 68 | S&F in repair 32 mm dia CP Coupling, complete all as specified and directed. |
| 69 | S&F in repair 15 mm bore central hole basin mixer with 450mm braided connection pipe (without popup). complete all as specified and directed. |
| 70 | S&F in repairs PVC waste pipe of 32 mm dia sutable for WHB & urinal etc complte, all as specified and directed,Make :Prayag or equvalent as per list of makes. |
| 71 | S&Fin repair 18 mm thick celuka ply of single side prelam/Rigidlam colour fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides, top and bottom and shelves inside the cabinets. complete all as specified and directed.(Density - 575 to 600 Kg/CBM)(Make Rajshri plastiwood or equivalent in make as specified in PS) |
| 72 | S&F in repair 30 mm width continous (piano) Hinges mild steel bright finish of electrogalvanised. complete all as specified and directed. |
| 73 | S&F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. |
| 74 | S&F in repairPVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed. |
| 75 | S&F in 600 mmx450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buildg board or commercial plywood and fixed to wooden plugs with CPbrass screws and cup washers. complete all as specified and directed. |
| 76 | S & F in repair Soap dish, stainless steel, standard size Soap dish, any type, fixed to plugs with chromium plated brass screws. complete all as specified and directed. |
| 77 | S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed. |
| 78 | S&F in repair brass chromium plated 2 way bib cock with wall flange 15 mm dia including fixing to pipe. complete all as specified and directed.Make Cat No Cera F-2002163 or equivalent in make as per list of makes. |
| 79 | S&F in repair Health faucet CP brass body with 8 mm dia 1.00 m long flexible tube and wall hook including fixing. complete all as specified and directed. |
| 80 | S&F in repair 15 mm bore Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed. complete all as specified and directed. |
| 81 | S & F in repair Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends for iron pipe or for unions 15 mm bore. complete all as specified and directed. |
| 82 | S&F in repair brass chromium plated shower roses with swivel joints, 125 mm sizein square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed. |
| 83 | S&F in repairBrass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed. |
| 84 | Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store. complete all as specified and directed. |
| 85 | Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store. complete all as specified and directed. |
| 86 | M&L for Cutting chases pinning in , making good to facing where reqd. and pointing in CM 1:3 to ends or edges of landing , steps, cills, sunshades,selfs lintels etc. and cutting chases for conceled for water tubing or conceled condute wiring etc and making good, cutting n.exc 10cm girth.complete all as specified & as directed. |
| 87 | Supply and fixing 15 mm bore galvanised steel water tubing \"medium grade\" with all fittings and fixed to walls, ceiling or laid in floors etc. complete all as specified and directed. |
| 88 | Supply and fixing 20 mm bore galvanised steel water tubing \"medium grade\" with all fittings and fixed to walls, ceiling or laid in floors etc. complete all as specified and directed. |
| 89 | M&L PVC(SWR) floor trap 75 mm bore plain with grating including jointing with solvent cement. complete all as specified directed. |
| 90 | Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories). |
| 91 | S&F in 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. complete all as specified and directed. |
| 92 | S & F in 75 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls.complete all as specified and directed. |
| 93 | S&F in 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including demolition of PCC if needed for removal of pipe. complete all as specified and as directed. |
| 94 | S&F in 110 mm PVC (SWR) bends any radius. complete all as specified and directed. |
| 95 | S&F in 75 mm PVC (SWR) bends any radius. complete all as specified and directed. |
| 96 | S&F in 75 mm PVC (SWR) junction single, (single T )(equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle oval access doorsbranches. complete all as specified and directed. |
| 97 | S&F in 110 mm PVC (SWR) junction single, (single T )(equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle oval access doorsbranches.complete all as specified and directed. |
| 98 | S&F in 75 mm bore PVC (SWR) branch piece, single (single Y), equal or unequal with access door. complete all as specified and directed. |
| 99 | S&F in 75 mm bore PVC (SWR) branch piece, Double (Double Y), equal or unequal with access door. complete all as specified and directed. |
| 100 | S&F in 110 mm bore PVC (SWR) branch piece, Double (Double Y), equal or unequal with access door. complete all as specified and directed. |
| 101 | S& F in110 mm PVC (SWR)vent cowl. complete all as specified and directed. |
| 102 | S&F in Stack clamps out of 50mm by 5mm flat iron for fixing of 75 mm pipe to wall including all fixing arrangement. complete all as specified and directed. |
| 103 | S&F in stack clamps out of 50mm by 5 mm flat iron for fixing of 100 mm pipe to wall including all fixing arrangement. complete all as specified and directed. |
| 104 | Excavating in trenches soft/loose soil n.exc 1.5M wide and n.exc 1.5M in depth, for foundation etc or shafts, wells cesspits, manholes, pier holes etc getting out etc, complete all as specified and directed. |
| 105 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 106 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed 200mm bore of pipe including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 107 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed 300mm bore of pipe including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 108 | M&L for 200mm bore (internal dia of pipe) reinforced concrete pipes, Class NP3 laid in trenches and jointed with CM (1:1), complete all as specified and directed. |
| 109 | M&L for 300mm bore (internal dia of pipe) reinforced concrete pipes, Class NP3 laid in trenches and jointed with CM (1:1), complete all as specified and directed. |
| 110 | M&L for PCC 1:3:6 type C2, (using 40mm graded aggregate) as in concrete bed to 200mm bore drain pipe including packing under and completely surrounding pipes with concrete after pipe laid and tested, complete all as specified and directed. |
| 111 | M&L for PCC 1:3:6 type C2, (using 40mm graded aggregate) as in concrete bed to 300mm bore drain pipe including packing under and completely surrounding pipes with concrete after pipe laid and tested, complete all as specified and directed. |
| 112 | Returning, filling in & including spreading, levelling& well ramming in layers not exceeding 25 cm thick as in soft/loose soil, complete all as specified and directed. |
| 113 | Removing excavated material of soils n exc. 50m and depositing where directed at a level n exc. 1.5 m. all as specified and directed. |
| 114 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in surface channel drains, complete all as specified and directed. |
| 115 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds ect., complete all as specified and directed. |
| 116 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping including weathening slightly rounded or chmfered angles and throating as directed and including necessary form work required, complete all as specified and directed. |
| 117 | Rending 10mm thick in CM 1:4 on concrete surfaces and finished even and smooth using extra cement complete with WPC (WPC measured and paid spperately), complete all as specified and directed. |
| 118 | S&F in rolled mild steel angle iron fram work such as in manhole cover etc with ends of bar solded and revited etc in all respect, complete all as specified and directed. |
| 119 | M&L for Preparation of new untreated steel surfaces of any description exc 10cm grith or width, and applying two coats of synthetic enamel paint over one coat of red oxide/primer etc. complete all as specified and directed. |
| 120 | S & F in layer 200mm dia (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls.complete all as specified and directed. |
| 121 | S & F in PVC SWR 200 bends any radius.complete all as specified and directed. |
| 122 | M & L for precast RCC 1:2:4 type B1,using 20 mm graded stone aggregate in cover slabs incuding necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately). complete all as specified and directed. |
| 123 | Cutting into existing manholes for connecting new drains of 200 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching. complete all as specified and directed. |
| 124 | Taking down carefully aluminium battenpoint, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i)Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii)Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii)Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. |
| 125 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI markedand including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:- Note : The cost of modular type box and modular accessories like inner/outer cover plates etc will be included in quoted rates. |
| 126 | (a)One light/fan/bellpoint controlled by one switch single pole one way. complete all as specified and directed. |
| 127 | (b) All as per item No 125.01here-in-before butone3 pin 6 amp switch socket out let independent. complete all as specified and directed. |
| 128 | (c) All as per item No125.01 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch, complete all as specified and directed. |
| 129 | All as per item No 125.02 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4.0 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board. complete all as specified and directed. |
| 130 | Supply and fixing switch modular flush 6A single pole one way ISI marked. complete all as specified and directed. |
| 131 | Supply and fixing modular sockets 6 Amp 2 in 1 2/3 pin combined. complete all as specified and directed. |
| 132 | Supply and fixing switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked. complete all as specified and directed. |
| 133 | Supply and fixing modular sockets 16Amp 2 in 1 3/5pin combined. complete all as specified and directed. |
| 134 | Supply and fixingceiling rose surface bakelite 60x25mm three terminal. complete all as specified and directed. |
| 135 | Supply and fixing electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type. complete all as specified and directed. |
| 136 | Supply and fixing MCB DB SPN 12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting. completeall as specified and directed. |
| 137 | Supply and fixing MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, \"C\" series fixed in DBs catered here-in-before.complete all as specified and directed. |
| 138 | Supply and fixing MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve. complete all as specified and directed by Engineer in charge. |
| 139 | M&L for taking down carefully existing ceiling fan/exhaust fan from site before B/R repair work, keeping in safe custody in store forgreasing / oiling of ball bearings / bushes and making it for smooth and noise free operation and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities\" and re-fixing after providing new fan clamp, nuts/bolts, washers, down rod as required and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface all as specified and directed. |
| 140 | M&L for taking down carefully existing geyser of any type and cap from site before B/R repair work, keeping in safe custody in store for servicing and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities, writing of MES No. and re-fixing with new hot and cold water connection as required incl provision of 3 core copper flexible cable of size 4 Sqmm complete with 15 Amps 3-pin plug top. complete all as specified and directed. |
| 141 | Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No. all as specified and as directed. |
| 142 | Supply & Fixing water heater storage vertical type, puff insulation type of 25 ltrs capacity and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement andincluding writing MES No. complete all as specified and directed. |
| 143 | Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLSH, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code . complete all as specified and directed. Note:- (a) Two runs of6 sqmm cable and one run of 6 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. |
| 144 | Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLSH, 1100 Volts gradecable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code. complete all as specified and directed. Note:- (a) Two runs of4 sqmm cable and one run of 4 Sqmm cable as earth leadwith conduit shall be measured as one unit length for payment.(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. |
| 145 | S & F for sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp. complete all as specified and directed. |
| 146 | Supply and fixing in repair Ventilating Fan250mm sweep,non metallic resin body,single phase 240 volts AC 50 Hz including louvers,and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge. Note : Old material deposited to MES store Yard. |
| 147 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep heavy duty 1400 RPM with, blades, and frame and louvers complete with all accessories for hang and connecting with 3 run of 1.5 sqm, multicore, PVC insulated copper cable from ceiling rose. complete all as specified and directed. |
| 148 | Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface. complete all as directed by Engr-in charge. |
| 149 | Supply and fixingLED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose. complete all as specified and directed. |
| 150 | Supply and fixing LED Light fitting mirror type with high out put diffuser 2 feet ,10watt ,220 v AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size. complete all as specified and directed. |
| 151 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |