| 1 | Part-A |
| 2 | SITC ofwall mounted cubical type Electrical panel board indoor type made of 2 mm thick CRCA sheet fully compartmentalized of size 400mm x 500mm duly dust & vermin proof powder coated & phosphatized with 7 tank process, complete with following switch gear mounted thereon, earthing strip of suitable size, connection, interconnection, sign writing with locking arrangement etc as required. (depth of 350mm)Incoming- a).125 A, 10kA, 4 Pole thermal magnetic release MCCB– 01 No. Busbar- a).200 A capacity, 4 strip aluminum bus bar– 01 setOutgoing- a).63 A, 10 KA, 2PoleMCB– 4 Nos. |
| 3 | Supplying and making end terminations with brass compression glands and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 4 | 2 X 25 sq. mm. (28mm) |
| 5 | 3 X35 sq. mm. (32mm) |
| 6 | Dismentalling ofthe following Electrical panel along with the removal of cables/wires/accessories etc. as required. i-Main Switch 3-ø, 63 A – 06 No.ii-Distribution board 6-Way- 06 No. |
| 7 | Buy back of the following panel along with the accessories A-Main Switch 3-ø, 63 A – 01 No.B-Distribution board 6-Way- 01 No. |
| 8 | Part-B |
| 9 | SITC of high efficiency100watt LED Flood light with pressure Die cast aluminium housing with lens and toughenedwith IP66protectionto operate on 140 - 270 volts AC having system lumens efficacy 100 Lumens/watt (minimum) in cool day Light (5700 to 6500K), Power Factor≥0.95, CRI≥70 and guarnteed life of50,000 burning hours with 2 year replacement warranty i/c dismantaling of old defective light fixtures etc complete as required. |
| 10 | Supply& Layingof1100 volts rated aluminium conductor steel wire / strip armored XLPEpower cable of following sizes as per IS-7098 part-Iwith ISI markedon wall surfaceincludingtesting at manufacturer site etc complete as required. |
| 11 | 2 Core 16 sq. mm. Armoured Aluminium cable. |
| 12 | SITC of 250 x 200 x 105 mm (inside) deep PVC pole boxes having locking arrangement in front, dust & virman proof i/c 2 nos. of aluminium busbar, 1 no. 16 AMPS. SP MCB, bakelite base plate, 2 Nos. 25 x 4mm MS clamps, nut bolts,complete in all respect etc. as required. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 14 | 8way Double Door |
| 15 | Supplying and fixing 5A to 32A rating, 24/415 V, 10kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 16 | Double Pole(32A) |
| 17 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | 63 Amps |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 20 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, singlecore cable in the existing surface/recessed steel/PVC conduit as require |
| 21 | 3 x 1.5 sq. mm |
| 22 | Supplying and making end terminations with brass compression glands and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 23 | 2 X 16 sq. mm. (22mm) |